Nonlinear co-existence of beta-induced Alfvén eigenmodes and beta-induced Alfvén-acoustic eigenmodes

The nonlinear co-existence of β–induced Alfvén eigenmode (BAE) and β–induced Alfvén-acoustic eigenmode (BAAE) is found in simulations using the gyrokinetic toroidal code, which provides a new mechanism responsible for BAAE excitation in tokamaks. In this work, the normalized pressure β is the ratio between plasma thermal pressure and magnetic pressure. The nonlinear simulation findings show that the BAAE branch emerges after the BAE branch is saturated. The mode structure's evolution shows that existence of BAAE will change the original BAE mode structure. The perturbed distribution functions in the velocity phase space show that a new resonance region manifesting the wave-particle resonance in the BAAE branch appears during the nonlinear co-existence stage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gamma and Beta Absorbed Dose Conversion Coefficients in the Range from 10 keV to 10 MeV for Accidental Exposures From Point Sources Placed in Clothing in Proximity to the Body [Gamma and Beta Absorbed Dose Conversion Coefficients in the Range from 10 keV to 10 MeV for Accidental Exposures From Point Sources Placed in Clothing in Close Vicinity to the Body]

Here, retrospective dose assessment following acute radiation exposures during radiological incidents can be difficult and inaccurate due to the large uncertainties associated with dose estimation. However, rapid and accurate dose assessment is critical following an incident, such that appropriate treatment can be provided to the patient as early as possible. Incident Dose assessment relies heavily on biological dosimetry with corresponding large uncertainties for inhomogeneous exposures, resulting from the estimates of whole-body doses, while the assessment of absorbed doses to individual tissues might actually be more appropriate for acute radiation exposures.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mechanical Design Analysis of MQXFB, the 7.2-m-Long Low- $\beta$ Quadrupole for the High-Luminosity LHC Upgrade

As part of the High-Luminosity Large Hadron Collider (LHC) Project, a set of Nb 3 Sn quadrupoles are being developed, aiming to enhance the performance of the inner triplets. The new magnets, identified as MQXFA and MQXFB, will share the same cross section with two different lengths, 4.2 and 7.2 m, respectively. During the magnet development, three short models were tested, along with a number of mechanical models, demonstrating the capability of the magnet cross section to achieve the specified performances. The same performances are now required for the full-length magnets. To ensure this, the authors studied the impact of the magnet length on the capability of the structure to provide an adequate support to the coils. Finite element and simplified analytical models were used to evaluate the impact of the magnet length on the stresses in the magnet ends and coil elongation during powering. Lastly, the models were calibrated using the results from the short model tests, and used to provide an indication on the required prestress and its foreseen impact on the magnet performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mechanical Analysis of the Short Model Magnets for the Nb $_{3}$Sn Low-$\beta$ Quadrupole MQXF

During the development of MQXF, the new Nb 3 Sn quadrupole to be used in the large hadron collider (LHC) inner triplets for the High Luminosity upgrade, three short models were tested: MQXFS1, MQXFS3, and MQXFS5. These models differ in the use of thin or thick laminations for the iron components, in the coil design, and in the superconductive strands, rod restack process (RRP) or powder in tube (PIT). In the MQXF design, the azimuthal prestress is provided at room temperature by means of the bladder-key technology, and it is further increased during the cooldown by the differential thermal contraction of the various components. Four aluminum rods provide the longitudinal prestress. Both systems allow for a flexible control of the amount of prestress applied. As a consequence, it was possible to test the models exploring different azimuthal and longitudinal prestress conditions, in an attempt to understand their impact on the magnet performances. Here, this paper studies the mechanical behavior of these short models, also providing the strain and stresses measured by means of strain gauges installed on the aluminum shell, on the winding poles and on the rods. Finally, the paper compares the measures with the results from finite element (FE) models.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Test Results of the CERN HL-LHC low- Quadrupole Short Models MQXFS3c and MQXFS4

For the High Luminosity Upgrade of the CERN Large Hadron Collider, lower * quadrupole magnets based on advanced Nb3Sn conductors will be installed on each side of the ATLAS and CMS experiment insertion zones. As part of the technological developments needed to achieve the required field gradient of 132.6 T/m within a 150-mm aperture, short length model magnets, named MQXFS, are tested both at the CERN SM18 and FERMI Lab test facilities. The model magnets rely on two types of Nb3Sn conductors (RRP and PIT) and on an innovative bladders and keys design to provide mechanical support against the Lorentz forces. In 2016 and 2017, the powering tests of the first two models MQXFS3 (RRP) and MQXFS5 (PIT) proved that nominal performance (16.5 kA) could be reached with excellent memory of the quench current after thermal cycle. However both magnets showed a slow training behavior with clear observations of voltage disturbances before the quench. Besides MQXFS5 only could reach ultimate current (17.9 kA) whereas erratic behavior was observed on MQXFS3 due to conductor local degradation at the head of one of the coil. In 2018, this limiting coil was changed and the applied azimuthal pre-stress increased. If ultimate current could then be reached, no stable current could be maintained due to identified defect on the outer layer of the new coil. Finally the outcome of the test of the new model MQXFS4, featuring the final RRP conductors that will be used for the series production and variation on the inner layer quench heater designs are here reported in details.