Search NASA⌕ Search

SEARCH · Search NASA

Results for “building load flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Methods for Computing Physically Realistic Estimates of Electric Water Heater Demand Response Resource Suitable for Bulk Power System Planning Models

Demand response is commonly called on to reduce load during system peak times or to respond to contingency events. In future power systems with higher shares of wind and solar generation (which we describe together as variable generation [VG]), demand response could have more opportunities to provide energy shifting or operating reserve services. This report evaluates the ability of residential electric water heaters, both electric resistance water heaters (ERWHs) and heat pump water heaters (HPWHs), to provide such services starting from detailed whole-building energy models that realistically represent New England single family home stock. We use a parsimonious surrogate model to represent operational flexibility in a form suitable for linear and mixed integer programming. This enables relatively fast determination of aggregate contingency reserve resource, price-taking energy shifting outcomes, and in some cases the determination of aggregate models at the megawatt (MW) scale that can be directly included in large-scale grid models. After selecting modeling methods and parameters through various computational experiments, we find interquartile ranges of contingency reserve resource in ISO-NE for about 603,400 ERWHs of 45 MW - 69 MW for Claim10 (50 minute responses provided with 10 minutes of advanced notification) and 65 MW - 102 MW for Claim30 (30 minute responses provided with 30 minutes of advanced notification), and for about 619,000 HPWHs of 48 MW - 88 MW for Claim10 and 52 MW - 90 MW for Claim30. The overall reserve resource is up to 32% of total load for ERWHs providing Claim10 service, 47% for ERWHs providing Claim30 service, 93% for HPWHs providing Claim10 service, and 97% for HPWHs providing Claim30 service. More work is required to determine if HPWHs are inherently more suitable than ERWHs for providing contingency reserve or if these results reflect idiosyncrasies of the single family home stock model used in this study. The value of this contingency resource in a Near-term VG model of ISO-NE is $\$ 0.40$ to $\$1.20$ per water heater-year, and significantly larger, $\$ 3.80$ to $\$ 5.30$ per water heater-year in a Mid-term VG model of ISONE. Aggregating surrogate models to the MW-scale for energy shifting service is more challenging than for contingency service and we only present such results for ERWHs, because we were unable to determine satisfactory ways to deal with HPWHs' time-varying and path dependent operational characteristics. Individual surrogate models suitable for evaluating the energy shifting resource from both ERWHs and HPWHs are created, however, and dispatched against day-ahead prices from the Near-Term VG and Mid-Term VG models of ISO-NE. The individual surrogate models are able to access and potentially shift all 640 GWh of HPWH load and 1,547 GWh of ERWH load we modeled in two different single family home stock models. In contrast, the most effective model of aggregate ERWH shifting resource we created only captured 34.7% of the total ERWH load. Energy shifting affected by price-taking dispatch against modeled day-ahead energy prices produces per water heater year profits of $\$19.44$ - $\$22.93$ for individual HPWHs, $\$39.11$ - $\$40.54$ for individual ERWHs, and up to $\$4.00$ - $\$4.24$ for aggregated ERWHs, with the variations mainly due to grid conditions (more or less VG). When the supply-side response to these changes is accounted for, the per water heater year production cost savings for ISO-NE are $\$7.50$ to $\$17.70$ for the most effective set of endogenously dispatched aggregate ERWHs, $\$15.60$ to $\$15.70$ for individual ERWHs dispatched against the DA prices, and $\$10.70$ to $\$11.20$ for individual HPWHs dispatched against DA prices. Those ranges primarily represent the difference between Near-Term VG and Mid-Term VG grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance evaluation of a dynamic wall integrated with active insulation and thermal energy storage systems

Thermal energy storage systems in buildings can store cooling/heating energy during non-peak load hours or when renewable energy sources are available for later use when demanded. Using the building envelope as a thermal battery can help to shave the peak load, reduce the burden in electric grids, and enhance the occupant's thermal comfort. Sensible energy storage on wall systems such as thermally activated building systems can provide an active thermal storage strategy. However, most of the stored energy is used through passive means directed by the thermal lag, which can impede the on-demand release of the stored energy. Integrating active insulation systems with building thermal storage systems can increase the flexibility of charging and discharging time and duration. In this study, a wall system equipped with an active insulation system and thermally activated storage system was designed, and its performance on active cooling energy contribution was studied. The performances of energy storage (charging), release (discharging) of the thermal energy storage energy, and the active insulation system were studied separately and together as an integrated system. Results showed that the thermal properties of the thermal energy storage core material and the pipe spacing of both embedded pipes in the thermal energy storage and hydronic pipes used in the active insulation system affected the wall performance the most out of all the tested wall system parameters. During discharging, the heat flux into the wall was as high as 81.92 W/m 2 . This active insulation system's dynamic R-value varied between less than 1ft 2 •°F•h/BTU (0.18 m 2 •K/W) to 98% of the equally thick foam insulation's R-value.

25 ENERGY STORAGE↗

Evaluation of smart charging for electric vehicle-to-building integration: A case study

Higher electric vehicle (EV) adoption will stress the importance of demand flexibility to achieve more economic, efficient, and reliable grid operation. Charging technologies will be paramount in shifting temporally to better fit the variable generation of wind and solar. As such, analysis is warranted on the benefits of EV charge scheduling with respect to installation cost, operation cost, difficulty of implementation, and grid flexibility. We tackle this by analyzing the cost savings of implementing an EV charge scheduling infrastructure to reduce demand charges and installation costs. In this paper, we analyze a case study for operation of 16 level 2 chargers and 1 fast charger for two different building types. We then evaluate various test phases for controlling building and charging loads using an adaptive charging network (ACN) algorithm to characterize the ACN’s potential to reduce overall project cost.

30 DIRECT ENERGY CONVERSION↗

Model-Free Building Temperature Control and Power Allocation Under Measurement Time Delays

Taking a step towards a greener planet has created an increased need for a higher integration of renewable energy resources into the electric grid. Nonetheless, the intermittency and uncertainty associated with renewable generation have slowed down this integration. Demand response (DR) has been recently adopted to address this challenge by utilizing demand side flexibility and enabling the participation of many grid-interactive efficient buildings (GEBs). However, existing DR methods require significant modeling and/or training efforts and are computationally expensive. To address the aforementioned issues, we propose a model-free control (MFC)-based strategy that is robust to the time delays in the temperature measurements of the thermostatically controlled loads (TCLs). It assigns to each GEB a local controller to maintain the TCLs’ temperatures within desired comfort levels, while the load aggregator (LA) allocates the assigned reference power provided by the distribution system operator (DSO) to support a specific grid service, such as demand peak reduction, load shifting, balancing supply and demand, and consuming the solar photovoltaic power locally. We investigate the effects of such loss of information on the local control action as well as on meeting the power allocation constraint. We conclude that, for an appropriate choice of design parameters, the proposed MFC controller is satisfactorily robust to measurement time delays.

Telsang, Bhagyashri↗

Making Grid-interactive Efficient Buildings a “Win” for Both Customers and Utilities

Buildings account for more than 70% of U.S. electricity use and at least one-third of U.S. economy-wide CO2 emissions. Changing the timing and overall amount of electricity consumption in buildings would significantly reduce energy costs to consumers and facilitate the transition to a decarbonized economy. Grid-interactive efficient buildings (GEBs) incorporate energy efficiency, smart technologies, and active use of distributed energy resources (DERs) to provide these benefits. As the link between the customer and the power system, utilities are central to widespread deployment of GEBs. Yet, despite the significant cost savings and operational benefits of GEBs for utilities, deployment has remained limited. This paper explores emerging models for enabling utilities to facilitate GEB adoption. Building off foundational research conducted to develop the U.S. DOE’s A National Roadmap for Grid-Interactive Efficient Buildings, we describe the most novel recent examples of ways in which utilities and regulators have made demand-side innovation a win for both the customer and the utility. Emerging concepts include: (1) performance incentive mechanisms to align GEB deployment with utility financial motivations, (2) the use of subscription pricing (i.e., fixed monthly bills) to promote load flexibility and energy efficiency, (3) rate-basing utility-controlled behind-the-meter assets, and (4) coupling energy efficiency and load flexibility with electrification proposals to ensure that customer benefits are maximized. The paper concludes with a discussion about prospects for widespread GEB deployment and utilization by utilities, and how to scale efforts.

Satchwell, Andrew↗

Description of FY25 Theory and Simulation Performance Target: Development of an integrated modeling framework for fusion reactor design and assessment

The urgency to deliver fusion power is growing now more than ever, with increasing pressure for both public programs and private companies to meet milestones timelines and overcome significant remaining technical challenges to ensure growth of a nascent fusion industry in time to meet rapidly growing clean energy demands. With incredible advancements in computation and years of investment in fusion model development and validation, integrated modeling is poised to fill a key role in accelerating the timeline to a fusion pilot plant (FPP). Future fusion pilot plants will operate in regimes far beyond current experience, and device design will rely on physics-based prediction and extrapolation. Many concepts will also rely on simulation to assess safety (shielding, tritium management, materials activation and lifetimes), economics and scalability before the decision to build. Importantly, integrated simulation can be used to reveal and solve the complexities of system integration that may otherwise not be apparent in physical components or models developed in isolation. New experimental test facilities that produce relevant conditions to validate and resolve key technical challenges for various subsystems (materials, blankets, fuel cycle, etc.) have been repeatedly called for by the fusion community but are not yet realized. Integrated modeling has an important role in identifying realistic load conditions (thermal, electromagnetic, plasma, neutron and photon loads, etc.) and defining the components and experiments for these test facilities in order to ensure meaningful validation that sufficiently reduces modeling uncertainties and technical risk for the full integrated reactor. The Fusion REactor Design and Assessment (FREDA) SciDAC project is building a component-based integrated modeling framework & data structure to enable self-consistent, multi-fidelity, iterative optimization workflows for the fusion reactor design process. FREDA aims to shorten the time to viable designs by providing a set of flexible workflows to support the various stages of the design process using an integrated model hierarchy, ranging from the simple analytic descriptions to the highest fidelity, theory-based plasma and engineering modeling developed by the fusion and fission communities. These tools are expected to be needed for timely support of FPP design in the milestone program and in the FIRE collaboratives. The plasma simulation backbone of FREDA is IPS-FASTRAN with newly developed coupled Core-Edge Pedestal-SOL (CESOL) workflows, which is being extended to the far-SOL region up to the plasma facing components. FREDA incorporates the FERMI engineering modeling suite and will enable self-consistent evaluation of the thermal shields, limiters, blanket, magnets, and other surrounding structures with predictions of temperatures, erosion, dpa, activation, tritium generation and transport, creep, corrosion, material degradation, etc. Parametric generation of 3D CAD enables rapid iteration of component geometry in response to plasma and loading specifications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabrication of hybrid tin oxide‐cellulose nanocomposite as the flexible and thin supercapacitor

Abstract Microfibrillated cellulose (MFC) with reinforcing effects is a useful building block in the fabrication of flexible and thin supercapacitors. Herein, a hybrid tin oxide‐cellulose nanocomposite was hydrothermally produced and coated on MFC thin films to form a supercapacitor. The hybrid tin oxide‐cellulose thin films were structurally analyzed using scanning electrode microscopy, Fourier transform infrared spectroscopy and x‐ray diffraction. The cellulose thin film with the highest loading of hybrid tin oxide‐cellulose nanocomposite exhibited a specific capacitance of 225.88 F g −1 at 100 mV s −1 and 486.38 F g −1 at 20 mV s −1 in the three‐electrode electrochemical system. In addition, it revealed good cyclic stability up to 40 cycles run continuously with 95% cyclic retention. The high specific capacitance and superior cyclic stability could be related to the enhanced charge mobility and ion diffusion between the solid and electrolyte interface. The cellulose thin film coated with flower‐like hybrid nanocomposite showed great potential in energy storage.

Letchumanan, Iswary↗

Thermodynamic Consistent Neural Networks for Learning Material Interfacial Mechanics

For multilayer materials in thin substrate systems, interfacial failure is one of the most challenges. The traction-separation relations (TSR) quantitatively describe the mechanical behavior of a material interface undergoing openings, which is critical to understand and predict interfacial failures under complex loadings. However, existing theoretical models have limitations on enough complexity and flexibility to well learn the real-world TSR from experimental observations. A neural network can fit well along with the loading paths but often fails to obey the laws of physics, due to a lack of experimental data and understanding of the hidden physical mechanism. In this paper, we propose a thermodynamic consistent neural network (TCNN) approach to build a data-driven model of the TSR with sparse experimental data. The TCNN leverages recent advances in physics-informed neural networks (PINN) that encode prior physical information into the loss function and efficiently train the neural networks using automatic differentiation. We investigate three thermodynamic consistent principles, i.e., positive energy dissipation, steepest energy dissipation gradient, and energy conservative loading path. All of them are mathematically formulated and embedded into a neural network model with a novel defined loss function. A real-world experiment demonstrates the superior performance of TCNN, and we find that TCNN provides an accurate prediction of the whole TSR surface and significantly reduces the violated prediction against the laws of physics.

Zhang, Jiaxin↗

CityLearn v2: energy-flexible, resilient, occupant-centric, and carbon-aware management of grid-interactive communities

As more distributed energy resources become part of the demand-side infrastructure, quantifying their energy flexibility on a community scale is crucial. CityLearn v1 provided an environment for benchmarking control algorithms. However, there is no standardized environment utilizing realistic building-stock datasets for distributed energy resource control benchmarking without co-simulation or third-party frameworks. CityLearn v2 extends CityLearn v1 by providing a stand-alone simulation environment that leverages the End-Use Load Profiles for the U.S. Building Stock dataset to create grid-interactive communities for resilient, multi-agent, and objective control of distributed energy resources with dynamic occupant feedback. While the v1 environment used pre-simulated building thermal loads, the v2 environment uses data-driven thermal dynamics and eliminates the need for co-simulation with building energy performance software. This work details the v2 environment and provides application examples that use reinforcement learning control to manage battery energy storage system, vehicle-to-grid control, and thermal comfort during heat pump power modulation.

Nweye, Kingsley↗

The Technical and Economic Potential of the H2@Scale Hydrogen Concept within the United States

The U.S. energy system is evolving as society and technologies change. Renewable electricity generation - especially from wind and solar - is growing rapidly, and alternative energy sources are being developed and implemented across the residential, commercial, transportation, and industrial sectors to take advantage of their cost, security, and health benefits. Systemic changes present numerous challenges to grid resiliency and energy affordability, creating a need for synergistic solutions that satisfy multiple applications while yielding system-wide cost and emissions benefits. One such solution is an integrated hydrogen energy system. This is the focus of H2@Scale - a U.S. Department of Energy (DOE) initiative led by the Office of Energy Efficiency and Renewable Energy’s Hydrogen and Fuel Technologies Office. H2@Scale brings together stakeholders to advance affordable hydrogen production, transport, storage, and utilization in multiple energy sectors. The H2@Scale concept involves hydrogen as an energy intermediate. Hydrogen can be produced from various conventional and renewable energy sources including as a responsive load on the electric grid. Hydrogen has many current applications and many more potential applications, such as energy for transportation - used directly in fuel cell electric vehicles (FCEVs), as a feedstock for synthetic fuels, and to upgrade oil and biomass - feedstock for industry (e.g., for ammonia production, metals refining, and other end uses), heat for industry and buildings, and electricity storage. Owing to its flexibility and fungibility, a hydrogen intermediate could link energy sources that have surplus availability to markets that require energy or chemical feedstocks, benefiting both. This document builds upon a growing body of analyses of hydrogen as an energy intermediate by reporting the results from our initial analysis of the potential impacts of the H2@Scale vision by the mid-21 st century for the 48 contiguous U.S. states. Previous estimates have been based on expert elicitation and focused on hydrogen demands. We build upon them, first, by estimating hydrogen’s serviceable consumption potential for possible hydrogen applications and the technical potential for producing hydrogen from various resources. We define the serviceable consumption potential as the quantity of hydrogen that would be consumed to serve the portion of the market that could be captured without considering economics (i.e., if the price of hydrogen were $0/kg over an extended period); thus, it can be considered an upper bound for the size of the market. We define the technical potential as the resource potential constrained by real-world geography and system performance, but not by economics. We then compare the cumulative serviceable consumption potential with the technical potential of a number of possible sources. Second, we estimate economic potential: the quantity of hydrogen at an equilibrium price at which suppliers are willing to sell and consumers are willing to buy the same quantity of hydrogen. We believe this method provides a deeper understanding than was available in the previous analyses. We develop economic potentials for multiple scenarios across various market and technology-advancement assumptions.

08 HYDROGEN↗

Field Study of Grid-connected Heat Pump Water Heaters in the Southeast U.S.: The Next Right Thing

The integration of grid-connected functionality and advanced control algorithms into heat pump water heaters (HPWH) offers the capability to shift load with minimal customer impact. This capability provides a flexible grid resource to utilities, while the increased energy efficiency of HPWHs offers customers a lower electric bill. The combined utility/customer value from grid-connected HPWHs is compelling in the Southeast U.S. where residential electric water heating is prevalent and utility load management is common. This paper presents the results of a HPWH load shifting study conducted in Central Florida using the CTA-2045 standard. Building upon previous research in the Pacific Northwest, this study consisted of approximately 45 occupied homes equipped with HPWHs undergoing load shifting strategies weekly for over a year. Curtailment durations ranged from three to five hours in the morning, and four to five hours in the evening to coincide with high-value periods for utility coincident load for system-wide electric demand reductions. During the morning and afternoon, a one- or two-hour load-up event preceded curtailment. Baseline data were collected across varied Florida weather in which no load shifting events were implemented. Results from traditional load shifting strategies were analyzed across seasons and used to devise unique load shifting approaches to increase renewable energy use during periods of high solar energy generation. Regional impacts are forecasted for large-scale implementation of strategies. Lessons learned and recommendations are also provided for how utilities, manufacturers, and regional planners can maximize load shifting benefits from grid-connected HPWHs.

Heat pump water heaters, residential building, loa↗

A Probabilistic Approach to Load Modeling for Central HVAC Systems in Large Commercial Buildings for Retrofit Decisions Under Uncertainty

Retrofitting central HVAC systems in large commercial buildings with advanced technologies like heat recovery chillers (HRCs) offers a significant opportunity to enhance energy efficiency. However, analyzing these retrofits is challenging with traditional whole-building simulation tools, which require intensive calibration and struggle to model innovative system configurations and controls. To overcome these limitations, this study proposes a load profilebased retrofit analysis framework that provides better decisions under uncertainty. The main focus of this paper is the development of a probabilistic load profile model that can be used in the framework by using exploratory data analysis (EDA) of measured building data to properly quantify its inherent variability. A non-parametric Gaussian Process (GP) model was employed to capture the time- and weather-dependent characteristics of the heating load while explicitly modeling its uncertainty. The model's effectiveness is demonstrated through strong predictive performance on unseen data and physically interpretable insights into load behavior. This data-driven, probabilistic load profile serves as a robust and flexible input for subsequent system simulations, enabling a more confident and statistically sound analysis of retrofit potential.

Ham, S W↗

Nodal capacity expansion planning with flexible large-scale load siting

We propose explicitly incorporating large-scale load siting into a stochastic nodal power system capacity expansion planning model that concurrently co-optimizes generation, transmission, and storage expansion. The potential operational flexibility of some of these large loads is also taken into account by considering them as consisting of a set of tranches with different reliability requirements, which are modeled as a constraint on expected served energy across operational scenarios. We implement our model as a two-stage stochastic mixed-integer optimization problem with cross-scenario expectation constraints. To overcome the challenge of scalability, we build upon existing work to implement this model on a high performance computing platform and exploit scenario parallelization using an augmented Progressive Hedging Algorithm. The algorithm is implemented using the bounding features of mpisppy, which have shown to provide satisfactory provable optimality gaps despite the absence of theoretical guarantees of convergence. We test our approach and assess the value of this proactive planning framework on total system cost and reliability metrics using realistic testcases geographically assigned to San Diego and South Carolina, with datacenter and direct air capture facilities as large loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sustainable Energy Solutions for Thermal Load in Buildings—Role of Heat Pumps, Solar Thermal, and Hydrogen-Based Cogeneration Systems

Economic and population growth is leading to increased energy demand across all sectors—buildings, transportation, and industry. Adoption of new energy consumers such as electric vehicles could further increase this growth. Sensible utilization of clean renewable energy resources is necessary to sustain this growth. Thermal needs in a building pose a significant challenge to the energy infrastructure. Potential technological solutions to address growing energy demand while simultaneously lowering the carbon footprint and enhancing the grid flexibility are presented in this study. Performance assessment of heat pumps, solar thermal collectors, nonfossil fuel-based cogeneration systems, and their hybrid configurations is reported in this study. The impact of design configuration, coefficient of performance (COP), electric grid’s primary energy efficiency on the key attributes of total carbon footprint, life cycle costs, operational energy savings, and site-specific primary energy efficiency are analyzed and discussed in detail. In conclusion, heat pumps and hydrogen-fueled solid oxide fuel cells (SOFCs) are highly effective building energy resources compared to traditional approaches; however, the carbon intensity of electrical energy and hydrogen production are keys to the overall environmental benefit.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

Wire arc additive manufactured A36 steel performance for marine renewable energy systems

Additive manufacturing has established itself to be advantageous beyond small-scale prototyping, now supporting full-scale production of components for a variety of applications. Despite its integration across industries, marine renewable energy technology is one largely untapped application with potential to bolster clean energy production on the global scale. Wave energy converters (WEC) are one specific facet within this realm that could benefit from AM. As such, wire arc additive manufacturing (WAAM) has been identified as a practical method to produce larger scale marine energy components by leveraging cost-effective and readily available A36 steel feedstock material. The flexibility associated with WAAM can benefit production of WEC by producing more complex structural geometries that are challenging to produce traditionally. Additionally, for large components where fine details are less critical, the high deposition rate of WAAM in comparison to traditional wrought techniques could reduce build times by an order of magnitude. In this context of building and supporting WEC, which experience harsh marine environments, an understanding of performance under large loads and corrosive environments must be understood. Hence, WAAM and wrought A36 steel tensile samples were manufactured, and mechanical properties compared under both dry and corroded conditions. Here, the unique microstructure created via the WAAM process was found to directly correlate to the increased ultimate tensile and yield strength compared to the wrought condition. Static corrosion testing in a simulated saltwater environment in parallel with electrochemical testing highlighted an outperformance of corroded WAAM A36 steel than wrought, despite having a slighter higher corrosion rate. Ultimately, this study shows how marine energy systems may benefit from additive manufacturing components and provides a foundation for future applications of WAAM A36 steel.

36 MATERIALS SCIENCE↗

Defining and applying an electricity demand flexibility benchmarking metrics framework for grid-interactive efficient commercial buildings

Building demand flexibility (DF) research has recently gained attention. To unlock building DF as a predictable grid resource, we must establish a quantitative understanding of the resource size, performance variability, and predictability based on large empirical datasets. Researchers have proposed various sets of theoretical metrics to measure this performance. Some metrics have been applied to simulation results, but most fall short of exploring the complexities in real building applications. There are practical metrics used in individual demand response field studies but they alone cannot fulfil the job of DF benchmarking across a diverse group of buildings. The electrical grid's geographically diverse and changing nature presents challenges to comparing building DF performance measured under different conditions (i.e., benchmarking DF). To address this challenge, a novel DF benchmarking framework focused on load shedding and shifting is presented; the foundation is a set of simple, proven single-event metrics with attributes describing event conditions. These enable benchmarking and visualization in different dimensions for identifying trends that represent how these attributes influence DF. To test its feasibility and scalability, the DF framework was applied to two case studies of 11 office buildings and 121 big-box retail buildings with demand response participation data. Furthermore, these examples provided a pathway for using both building level benchmarking and aggregation to extract insights into building DF about magnitude, consistency, and influential factors. Potential applications of the framework and real-world values have been identified for grid and building stakeholders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Future Industrial Demand: Large, Elastic, and Concentrated [Guest Editorial]

Here, the future industrial demand on the grid is expected to be large, price sensitive, and concentrated. Grid industrial demand increasingly encompasses a new customer type defined as a large flexible load (LFL). This LFL type defines customers with consumption that responds quickly to price or other incentives without interrupting their core business process, such cryptocurrency mining. This customer type can often ramp up and down quickly, which across an entire industry can mean gigawatts of power within a few minutes. In addition to these price-sensitive loads, significant growth is also anticipated in sectors like manufacturing, data centers, and electrification of transportation and buildings.

Mukherjee, Srijib [Oak Ridge National Laboratory (↗