Search NASA⌕ Search

SEARCH · Search NASA

Results for “capacity building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Energy and AI: Evaluating Future Grid and Water Stress Due to Data Centers

Projections of the need for new data centers to support Artificial Intelligence (AI) are large but highly uncertain. Recent projections indicate up to a 15% annual growth rate in data center electricity demand within the next 5-10 years. Given that most electric utilities are required to have a reserve margin of roughly the same magnitude as the projected growth in demand, these new data center loads could soon threaten resource adequacy and reliability unless data centers build their own generation, interruptible loads are negotiated, commensurate new capacity and/or transmission is built, or some combination of these options. Similarly, depending on the cooling technology and geographic location of new data centers, they could threaten water adequacy in water scarce regions. This presentation highlights the grid and water implications of new data centers to support AI.

Mongird, Kendall (ORCID:0000000328077088)↗

Assessing Impacts on Pressure Stabilization and Leasing Acreage for CO 2 Storage Utilizing Oil Migration Concepts

Favorable geological storage for CO 2 has long been pictured as large anticlines with thick sandstones, similar to oil reservoirs in the petroleum system. Unlike oil, however, stored CO 2 does not need to be recoverable, which raises the possibility of using dissolution and residual trapping to augment the capacity of buoyant traps and tap more of the bulk rock volume. The work presented builds on that idea, asking the following question: If we inject CO 2 down to a syncline – analogous to the carrier bed in the petroleum system – how would this injection mechanism impact storage capacity and plume shape, migration, and stabilization? To address this question, we built a reservoir model, based on seismic interpretation of Middle Miocene strata, offshore Galveston, Texas. 3-D seismic and well logs were used to characterize key intervals. Reservoirs chosen for modeling are progradational-aggradational sands with mud intercalation. They have a higher degree of heterogeneity than the more conventional reservoirs commonly targeted for CO 2 storage. Modeling investigated how far the CO 2 plume would migrate under two scenarios: (1) injecting CO 2 at the base of the salt withdrawal basin (syncline scenario) and (2) injecting CO 2 at the base of the structural closure, similar to a common injection well location for EOR purposes (base scenario). For each scenario, we separately simulated injection of 30 MT of CO 2 and 60 MT of CO 2 continuously for 30 years and observe the plume and pressure evolution for 100 years after the injection stops. The simulation shows that injecting the CO 2 into a syncline limits the vertical migration of CO 2 , thus making synclinal injection more secure. In the syncline scenario, the geological layer around the injection point is more heterogeneous than the layer in the base scenario; thus, the CO 2 tends to migrate laterally. Additionally, in the syncline scenario, the plume does not even reach the upper part of the anticline, allowing us to safely store an additional amount of CO 2 into the reservoir. Furthermore, the simulation also shows that in the syncline scenario, the times needed for the reservoir to reach its stabilized pressure after the end of injections are faster. To summarize, CO 2 injection at the base of a syncline could provide additional storage, increase the safety of the project from the limited vertical plume migration, and expedite plume stabilization, which could result in the decrease of monitoring frequency as the project runs, thus lowering the operating cost of the project in the long run.

58 GEOSCIENCES↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

Oversizing and Part-Load Problems

Oversizing, the common engineering practice of specifying devices with capacity exceeding the actual load requirement, is a widespread practice across virtually all building technologies end-use categories, including HVAC, electrical systems, lighting, appliances, and plug loads. This practice, driven by factors like design uncertainty, institutional pressures, and risk aversion, results in wasted capital investment, control difficulties, and excessive energy consumption due to inefficient part-load operation. Part-load operation, where devices run below maximum capacity, is the dominant operating mode in most energy systems and presents a complex design challenge. Solutions to match output to load fall into three broad categories: constraining the output, adjusting the device’s internal behavior, and linking output to energy storage or other waste-heat reuse applications. The energy implications of part-load are critical, as efficiency often drops sharply as load decreases across a wide diversity of devices. To quantify the extent of this problem, we derive a dimensionless Part-Load Metric (PLM) based on device efficiency and its frequency distribution of operating hours at various output levels. The PLM quantifies the deviation of a device's actual efficiency from its maximum design efficiency. This metric also serves as a measure of "capital inefficiency," enabling engineers to compare the impact of different part-load solutions and providing a unified framework for evaluating performance across various devices and systems.

Meier, Alan↗

Stabilizing the Deep Sodiation Process in Layered Sodium Manganese Cathodes by Anchoring Boron Ions

Advanced high-energy-density sodium-ion batteries (SIBs) are inseparable from cathode materials with high specific capacities. Layered manganese-rich oxides (Na x MnO 2 , 0.6 ≤ x ≤1) are promising cathode materials owing to their ease of intercalation and extraction of a considerable amount of sodium ions. However, lattice interactions, especially electrostatic repulsive forces and anisotropic stresses, are usually caused by deep desodiatin/sodiation process, resulting in intragranular cracks and capacity degradation in SIBs. Here, boron ions are introduced into the layered structure to build up B-O-Mn bonds. Further, the regulated electronic structure in Na 0.637 B 0.038 MnO 2 (B-NMO) materials inhibits the deformation of MnO 6 octahedra, which finally achieves a gentle structural transition during the deep sodiation process. B-NMO electrode exhibits a high capacity (141 mAh g –1 ) at 1 C with a capacity retention of 81% after 100 cycles. Therefore, anchoring boron to manganese-rich materials inhibits the detrimental structural evolution of deep sodiation and can be used to obtain excellent cathode materials for SIBs.

25 ENERGY STORAGE↗

CRADA Number NFE-21-08879 with Hempitecture Inc. (CRADA Final Report)

Participant is a company that was founded on the idea that sustainable materials can help build a better world. These materials can build a better world by preserving our health, saving energy, and storing carbon dioxide. Participant is at a critical juncture where it has significant sales and manufacturing capabilities that can bring innovative, low-carbon, hemp-based building products to market at scale in the United States, but the company has lacked the time and resources to conduct new product development and testing. At Innovation Crossroads, Participant plans to prototype, test, and develop its product roadmap while obtaining necessary performance and impact measurements of its hemp building products for commercialization. Coming into Innovation Crossroads, only one of Participant’s products has commercial sales, HempWool®. Investments are currently being made to add manufacturing capacity in the United States and to provide Participant with the capability to expand its product line throughout the building envelope.

36 MATERIALS SCIENCE↗

A Priority-Based Control Strategy and Performance Bound for Aggregated HVAC-Based Load Shaping

Air conditioning systems have been recognized as a potential, cost-effective resource for shaping electrical load in a power system. This work presents a new priority-based control strategy that explicitly addresses three requirements for using a collection of air conditioning units in this capacity. These are 1) tracking a regulation signal, 2) maintaining the building temperature near its set point, and 3) satisfying a cycling constraint of the air conditioners. After introducing the control strategy, we derive a bound for the regulation signal within which tracking is guaranteed while also satisfying the temperature requirement. These results are illustrated with simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parametric and Nonparametric Models of U.S. Cost Overruns for Nuclear Power Plants

This study presents new data-driven models to estimate the effect of capacity on the percentage of cost overruns in the United States for nuclear power plant construction projects before and after the Three Mile Island accident. Parametric and nonparametric models have been developed that describe the significant shifts in nuclear energy costs during the dynamic environment. Employing a contemporary descriptive methodology and a quantitative analysis, we furnish a comprehensive overview of the alterations in cost overrun distribution and show the changes observed in other pivotal metrics alongside cost overruns. Our emphasis lies in documenting the fluctuations in cost overruns alongside nuclear reactor capacity levels and the increase of the overnight capital costs to build nuclear reactors. Our results show that increasing the size of nuclear reactors is not a factor statistically significant to decrease the percentage of cost overruns, and the probit model results provide evidence that an increase in size increases the probability of having cost overruns larger than 100% (double the estimated cost). We also compare our findings to two other regions: Asia and Europe.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of Space-Conditioning Loads in Commercial Buildings

Space conditioning end-uses, which include heating, cooling, and ventilation, represent a significant fraction of commercial building energy use, with a wide variety of heating and cooling technology options available in the market. In the interest of improving the overall efficiency of heating, ventilation and air-conditioning (HVAC) technologies, governments, utilities and private sector entities have implemented a variety of market transformation policies that aim to influence consumer purchase decisions. To evaluate the costs and benefits of such programs, analysts typically postulate a hypothetical default equipment choice, and compare it to one that provides comparable service with lower energy and/or power use. The corresponding reduced operating cost provides a benefit that offsets the potential higher cost of improved efficiency. Typically, life-cycle cost or cash-flow analyses are used to quantify the net economic benefit. These analyses require the capability to assess how a given equipment design would perform across a broad range of characteristics, both of the building and of the local weather. While these assessments can be performed using customized building simulations, it is generally not practical to develop and validate detailed building simulation code to cover all the potential variations of equipment design and installation. An alternative, and somewhat simpler, approach is to solely use detailed building simulations to generate time series of heating and cooling loads in commercial buildings. These loads can then be used as input to more detailed, stand-alone engineering models that simulate HVAC system performance under different equipment designs. This approach was used to evaluate a range of high-efficiency commercial packaged air conditioner design options for the Department of Energy’s Appliance and Equipment Standards Program (DOE-EERE 2015). While there may be some loss of precision relative to full simulation, the accuracy of this approach is sufficient for practical applications of cost-benefit analysis. This report describes the development of a database of commercial building heating and cooling loads, generated using the EnergyPlus software package, a whole building energy use model supported by the Department of Energy (DOE-EERE 2020a). EnergyPlus takes as input a set of configuration files that describe the building itself (size, zoning, envelope characteristics, etc.) and the various systems within it (HVAC, lighting, water heating, etc.). This analysis uses a publicly available collection of commercial reference buildings (CRB), comprised of sixteen building types and three vintages (DOE-EERE 2020b; Deru et al 2011). Each building is simulated in eighteen different locations, covering a wide range of climatic conditions. The prototype building description files assign the type of HVAC equipment used, and capacities across climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Women as a force multiplier for bringing nuclear forensic capabilities to the international stage

In 2009, the U.S. Department of Energy / National Nuclear Security Administration’s (DOE/NNSA) Defense Nuclear Nonproliferation (DNN) Program initiated a new nuclear forensics outreach effort under its Confidence Building Measures Program. Little did they know that the timing could not have been better. This article focuses on the early years (2009-2015) of the NNSA’s international nuclear forensics outreach, specifically the efforts and experiences of the women who helped establish this program, building it from a fledgling bilateral effort into an enduring technical capacity provider engaging with dozens of countries and multilateral organizations. At the onset of the program, nuclear forensics was an emerging priority within the U.S. Government and receiving increased focus from international organizations through high-level diplomatic efforts such as the Nuclear Security Summit and Global Initiative to Combat Nuclear Terrorism. Additionally, working-level initiatives were gaining traction through the International Atomic Energy Agency and the Nuclear Forensics International Technical Working Group. Over the next six years, a small team comprised of a uniquely large number of women NNSA federal, contract, and national laboratory staff served as key leaders engaging with the international community to strengthen global technical nuclear forensics capacity and best practices. The program continues today under the Nuclear Smuggling Detection and Deterrence Program as Investigation Support. The experiences shared here detail a unique time period when the new technical discipline of nuclear forensics was beginning to mature and gain international traction. The authors have made every effort to remember history correctly and be as inclusive as possible. A wealth of training, guidance, and exercises documentation was developed in the 2009-2015 timeframe, much of which still serves as the foundation for today’s even more extensive program and community of dedicated technical and diplomatic practitioners.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Building Demand Flexibility: Grid Service Value of Future Market Entrants

The building sector is an important source of demand-side flexibility that is crucial for renewable energy integration in the future power systems. The grid service value of building flexibility, especially that which provides load shifting, has not been analyzed for the United States. We use a technology-agnostic approach based on detailed grid expansion and production cost modeling results to evaluate the capacity, energy, and ancillary service values of a marginal kilowatt-hour (kWh) of daily, shiftable building flexibility as a presumed market entrant in the 2030 U.S. power systems. We find the monthly mean of building flexibility has a range of 0-38 cents/kWh-day, depending on the original usage hour, month, region, building flexibility parameters, and grid scenario. The daily value consists of the highest-value hour each day across all the scenarios has a range of 0-620 cents/kWh-day. The results are provided in an open database for users to obtain the values of specific technologies based on what services can be provided, when, and in what quantities.

30 DIRECT ENERGY CONVERSION↗

Modeling occupancy-driven building loads for large and diversified building stocks through the use of parametric schedules

Building energy modeling provides a fundamental tool to assess the potential for energy efficiency to contribute to reducing world energy consumption and global emissions. Occupancy-related operations are a key source of uncertainty for building energy analysis, particularly for aggregated building stocks. At a district or city level, it is critical to estimate aggregated power load profiles for sizing power grid infrastructure, power plant capacity allocation, and energy efficiency measures. The stochastic nature of behavior-related operations complicates the creation of models that accurately capture building load profiles for entire building stocks. This research introduces a new methodology called parametric schedules to model occupancy-driven schedules for large and diverse building stocks. In contrast to computationally expensive methodologies proposed in the literature, our work does not use a recursive time-consuming step. Occupancy is estimated by the extrapolation of operation times directly from metered electric consumption data; occupancy-related schedules are stochastically assigned to each building model, guaranteeing diversity of operation times in the stock. Our procedure has been tested on a large, diversified data-set of 25,000 commercial buildings in Los Angeles, California. It proved to be able to adequately represent the stochastic schedules diversity of the stock and to refine the stock calibration process by 1%. This innovative approach represents a useful asset for utility companies, grid operators, urban planners, and balancing authorities, seeking to improve building stock modeling and better estimate the impact of energy conservation measures. – This work is part of a larger stock modeling tool called ComStock, which is under development by NREL.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stable salt hydrate-based thermal energy storage materials

Heating and cooling systems in building infrastructure utilize conventional materials that account for a considerable amount of energy usage and waste. Phase change material (PCM) is considered a promising candidate for thermal energy storage that can improve energy efficiency in building systems. In this work, a novel salt hydrate-based PCM composite with high energy storage capacity, relatively higher thermal conductivity, and excellent thermal cycling stability was designed and developed. The thermal cycling stability of the PCM composite was enhanced by using dextran sulfate sodium (DSS) salt as a polyelectrolyte additive, which significantly reduced the phase segregation of salt hydrate. The energy storage capacity and the thermal conductivity of the composite were enhanced by the addition of various graphitic materials along with Borax nucleator. A significant increase in thermal cycling stability was observed for the DSS-modified composite, with over 100 thermal cycles without degradation. The final PCM composite exhibited as much as 290% increase in energy storage capacity relative to the pure salt hydrate, and approximately 20% increase in thermal conductivity. In addition, the PCM composite developed can be produced at larger scale, and can potentially change the future of heating/cooling system in building infrastructure.

42 ENGINEERING↗

Parametric and sensitivity analysis of a PCM-integrated wall for optimal thermal load modulation in lightweight buildings

Load modulation in buildings is becoming increasingly important due to growing disparity in energy demand during peak and off-peak hours. Integrating phase change material (PCM) in building envelopes and using a controlled precooling strategy can provide substantial thermal load modulation; however, it may greatly increase the total energy use. Previous studies have employed PCM in building envelopes primarily for energy savings and, to some extent, peak load shedding and shifting. However, the load modulation capacity of a PCM-integrated envelope has not been well explored in the literature. In this study, we perform an extensive parametric and sensitivity analysis on PCM-integrated lightweight building walls and examine the combinatory effects of various PCM parameters on thermal load modulation and wall-related heat gains in buildings. Using numerical simulations, we investigate eight PCM parameters: PCM location in the wall, transition temperature, thickness, latent heat, transition range, density, specific heat, and thermal conductivity. Here, we evaluate their impact and relative importance to achieve maximum load modulation in buildings without compromising occupants’ thermal comfort or total energy use. The results show that the optimized PCM proposed in this study can completely invert the transient heat gain profile of the wall, providing up to 70% reduction of wall-related heat gain during peak hours without a major increase in the cumulative heat gain.

42 ENGINEERING↗

Impacts of common faults on an air conditioner with a microtube condenser and analysis of fault characteristic features

Split system air conditioners are widely used to cool residential buildings, because of their low cost and simplicity. However, their efficiency is impacted by installation faults, which include: improper refrigerant charge (undercharge or overcharge), improper evaporator airflow, liquid line restrictions (LL), and the presence of non-condensable gas (NC) in the refrigerant. No known previously published research has studied the effect of these four faults on a system equipped with a microtube condenser, which has smaller tube size than a traditional condenser and therefore holds less refrigerant charge, but has a different configuration than a microchannel. Furthermore, very few have studied the impacts of LL and NC. Herein this paper describes laboratory fault tests of a microtube-equipped system, compares the fault impacts with those of a traditional system, and considers the characteristic fault features. The tested system uses R-410A refrigerant and has a scroll compressor, a fixed orifice expansion device, and two fin-tube heat exchangers. The tests were carried out under steady operation with a range of fault intensities and operating conditions. The microtube system’s performance degradation from faults is similar to systems with traditional heat exchangers, despite the reduced capacity to hold refrigerant charge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phase change material-to-refrigerant heat exchangers: Experimental validation and uneven melting analysis

Thermal energy storage (TES) using phase change materials (PCMs) enables load shifting and reduces mismatches between the building's thermal demand and the heat pump (HP) system's thermal capacity. While most TES studies have focused on single-phase heat transfer fluids, PCM-to-refrigerant heat exchangers (PRHX), in which the refrigerant undergoes liquid-vapor phase change, remain largely underexplored. Here, to address this gap, this study systematically investigates a shell-and-tube PRHX operating as the condenser in an HP through experiments and simulations. A two-dimensional enthalpy-based finite-volume PRHX model was developed and validated against experimental data, including refrigerant and PCM temperature profiles, PRHX capacity, and system-level performance. Results show three characteristic stages: Stage I, the condenser temperature rapidly increases with PCM in the solid state absorbing sensible heat; Stage II, stable operation during PCM phase change; and Stage III, performance decline once part of the PCM becomes fully melted. Heat transfer analysis revealed that uneven PCM melting along the condenser length was driven primarily by variations in the refrigerant-side heat transfer coefficient, rather than local approach temperature differences. Further study demonstrated that minimizing refrigerant outlet subcooling led to more uniform PCM melting and extended Stages I and II by up to 89%. This paper provides a validated PRHX model, clarifies the mechanisms of uneven PCM melting, and highlights subcooling control as an effective strategy to improve TES performance in HP systems without requiring secondary loops.

Graphite matrix↗

Polyurethanes Based on Unmodified and Refined Technical Lignins: Correlation between Molecular Structure and Material Properties

The structural complexity and robust intermolecular interactions have challenged the incorporation of technical lignin into value-added polymeric materials for decades. To study the correlation between lignin molecular structure and material properties of lignin-based polyurethanes, we applied co-solvent enhanced lignocellulosic fractionation pretreatment followed by sequential precipitation to produce three distinct lignin preparations with narrowly distributed (molecular weight dispersity <2) and comparatively low molecular weight (<1500 g/mol) from poplar biomass. Structural characterization indicated that these lignin preparations differed in average molecular chain length and stiffness as well as hydroxyl group distribution. Secondary hydroxyl group providers such as aliphatic diols and polyethers were incorporated as building blocks into the lignin-based polyurethanes to provide additional hydrogen capacity to improve the dispersion of lignin in the polyurethane network. The selected aliphatic diols and polyethers interacted with lignin molecules at different levels of strength depending on their molecular structure, and their impacts were ultimately reflected in the mechanical and thermal properties of the resulting lignin-based polyurethanes. The copolymerization of technical lignin with tailored structure and secondary hydroxyl providers could provide new strategies in formulating lignin-based/containing polyurethanes for various functional applications.

36 MATERIALS SCIENCE↗

Lone-Electron-Pair Micelles Strengthen Bond Anharmonicity in MnPb16Sb14S38 Complex Sulfosalt Leading to Ultra-Low Thermal Conductivity

Designing crystalline solids in which intrinsic extremely low lattice thermal conductivity mainly arises from its unique bonding nature rather than structure complexity and/or atomic disorder could promote thermal energy manipulation and utilization for applications ranging from thermoelectric energy conversion to thermal barrier coatings. Here, we report an extremely low lattice thermal conductivity of ~0.34 W m-1 K-1 at 300 K in the new complex sulfosalt MnPb16Sb14S38. We attribute the ultra-low lattice thermal conductivity to a synergistic combination of scattering mechanisms involving (1) strong bond anharmonicity in various structural building units, owing to the presence of stereoactive lone-electron-pair (LEP) micelles, and (2) phonon scattering at the interfaces between building units of increasing size and complexity. Remarkably, low-temperature heat capacity measurement revealed a Cp value of 0.206 J g-1 K-1 at T > 300 K, which is 22% lower than the Dulong-Petit value (0.274 J g-1 K-1). Further analysis of the Cp data and sound velocity (ν = 1834 m/s) measurement yielded Debye temperature values of 161 K and 187 K, respectively. Here, the resulting Grüneisen parameter, γ = 1.65, further supports strong bond anharmonicity as the dominant mechanism responsible for the observed extremely low lattice thermal conductivity.

36 MATERIALS SCIENCE↗