Search NASA⌕ Search

SEARCH · Search NASA

Results for “capillary flows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Gas-flow restrictor

Gas flow restrictor is described, consisting of predetermined length and size of capillary tubing to control flow rate of carrier gas into gas chromatograph of flow rate of sample gas into mass spectrometer inlet system. Length and inner diameter of capillary tubing was estimated with mathematical expressions for viscous flow.

Bastien, G. J.↗

Scaling the impacts of pore-scale characteristics on unstable supercritical CO 2 -water drainage using a complete capillary number

Geological carbon storage in deep aquifers involves displacement of resident brine by supercritical CO 2 (scCO 2 ), which is an unstable drainage process caused by the invasion of less viscous scCO 2 . The unstable drainage is greatly complicated by aquifer heterogeneity and anisotropy and regarded as one of the key factors accounting for the uncertainty in storage capacity estimates. The impacts of pore-scale characteristics on the unstable drainage remain poorly understood. In this study, scCO 2 drainage experiments were conducted at 40 °C and 9 MPa using a homogeneous elliptical micromodel with low or high anisotropy, a homogeneous/isotropic hexagonal micromodel, and a heterogeneous sandstone-analog micromodel. Each initially water-saturated micromodel was invaded by scCO 2 at different rates with logC a (the capillary number) ranging from -7.6 to -4.4, and scCO 2 /water images were obtained. The measured CO 2 saturations in these centimeter-scale micromodels vary considerably from 0.08 to 0.93 depending on the pore-scale characteristics and capillary number. It was also observed that scCO 2 drainage follows the classic flow-regime transition from capillary fingering through crossover to viscous fingering for either of the low-anisotropy elliptical and heterogeneous micromodels, but with disparate crossover zones. The crossover zones of scCO 2 saturation were then unified with the minimum scCO 2 saturation occurring at logC$_a^*$ = -4.0 using the complete capillary number (C$_a^*$)that considers pore characteristics. For the hexagonal and the high-anisotropy elliptical micromodels, a monotonic increase in scCO 2 saturation with increasing C$_a^*$ (without crossover) was observed. It appears that the complete capillary number is more appropriate than the classic capillary number when characterizing flow regimes and CO 2 saturation in different pore networks.

58 GEOSCIENCES↗

Preliminary investigation of elongational flow of dilute polymer solutions

A tubeless siphon apparatus has been set up to measure extensional flow. In this apparatus, the liquid is continuously drawn into a capillary and, after steady flow has been established, the tube is raised above the liquid surface. With viscoelastic liquids, the flow continues and a column can be lifted from the reservoir. At the capillary entrance, an oscillating bead of excess liquid collects which interferes with both the flow and the measurements. This can be minimized by careful control of the liquid-column height. For homogeneous solutions, the column is symmetrical and tapers steadily from the liquid surface to the capillary entrance, with no bulging. Preliminary results show tensile viscosities 1000 times that of the Trouton coefficient and having a very strong dependence on deformation rate. A concentration-stretch rate-reduced variable scheme is proposed.

Peng, S. T. J.↗

Dynamics of Liquids in Edges and Corners (DYLCO): IML-2 Experiment for the BDPU

Knowledge of the behavior of fluids possessing free surfaces is important to many fluid systems, particularly in space, where the normally subtle effects of surface wettability play a more dramatic and often surprising role. DYLCO for the IML-2 mission was proposed as a simple experiment to probe the particular behavior of capillary surfaces in containers of irregular cross section. Temperature control was utilized to vary the fluid-solid contact angle, a questionable thermodynamic parameter of the system, small changes in which can dramatically influence the configuration, stability, and flow of a capillary surface. Container shapes, test fluid, and temperature ranges were selected for observing both local changes in interface curvature as well as a global change in fluid orientation due to a critical wetting phenomenon. The experiment hardware performed beyond what was expected and fluid interfaces could be readily digitized post flight to show the dependence of the interface curvature on temperature. For each of the containers tested surfaces were observed which did not satisfy the classic equations for the prediction of interface shape with constant contact angle boundary condition. This is explained by the presence of contact angle hysteresis arising from expansion and contraction of the liquid during the heating and cooling steps of the test procedure. More importantly, surfaces exceeding the critical surface curvature required for critical wetting were measured, yet no wetting was observed. These findings are indeed curious and pose key questions concerning the role of hysteresis for this critical wetting phenomena. The stability of such surfaces was determined numerically and it is shown that stability is enhance (reduced) when a surface is in its 'advancing' ('receding') state, The analysis shows complete instability as the critical wetting condition is reached. The case of ideal dynamic wetting is addressed analytically in detail with results of significant flow characteristics presented in closed form. The solutions indicate a square root of T dependence of the capillary 'rise' rate which is corroborated by drop tower tests. The analysis clearly shows that infinite time is necessary for surfaces to reorient at the critical wetting transition.

Langbein, D.↗

Flow in a differentially rotated cylindrical drop at low Reynolds number

A liquid drop held captive between parallel disks that are differentially rotated is a model for the swirling flows induced by crystal rotation in the floating-zone process for growing semiconductor materials. An asymptotic analysis for a cylindrical drop is presented that elucidates the structure of the axisymmetric cellular motions caused by disk rotation at low Reynolds number. Variations of meniscus shape induced by these flows are described in the limit of small capillary number. Most cellular flow fields break the bifurcation point that corresponds to the Plateau-Rayleigh limit for the length of a static drop into two disjoint shape families and lower the maximum stable drop length. This effect is studied by a singular bifurcation analysis.

Harriott, G. M.↗

Pore-scale study of capillary trapping mechanism during CO2 injection in geological formations

Geological sequestration of CO{sub 2} gas emerged as a promising solution for reducing amount of green house gases in atmosphere. A number of continuum scale models are available to describe the transport phenomena of CO{sub 2} sequestration. These models rely heavily on a phenomenological description of subsurface transport phenomena and the predictions can be highly uncertain. Pore-scale models provide a better understanding of fluid displacement processes, nonetheless such models are rare. In this work we use a Smoothed Particle Hydrodynamics (SPH) model to study pore-scale displacement and capillary trapping mechanisms of super-critical CO{sub 2} in the subsurface. Simulations are carried out to investigate the effects of gravitational, viscous, and capillary forces in terms of Gravity, Capillary, and Bond numbers. Contrary to the other published continuum scale investigations, we found that not only Gravity number but also Capillary number plays an important role on the fate of injected CO{sub 2}. For large Gravity numbers (on the order of 10), most of the injected CO{sub 2} reaches the cap-rock due to gravity segregation. A significant portion of CO{sub 2} gets trapped by capillary forces when Gravity number is small (on the order of 0.1). When Gravity number is moderately high (on the order of 1), trapping patterns are heavily dependent on Capillary number. If Capillary number is very small (less than 0.001), then capillary forces dominate the buoyancy forces and a significant fraction of injected CO{sub 2} is trapped by the capillary forces. Conversely, if Capillary number is high (higher than 0.001), capillary trapping is relatively small since buoyancy dominates the capillary forces. In addition, our simulations reveal different types of capillary trapping and flow displacement mechanisms during and after injection. In gravity dominated cases leave behind was the widespread trapping mechanism. Division was the primary trapping mechanism in viscous dominated cases. In capillary dominated cases, snap-off of the CO{sub 2} plume is the most commonly observed displacement mechanism. Large CO{sub 2} blobs are created due to coalescence mechanism.

54 ENVIRONMENTAL SCIENCES↗

On the use of Darcy's law and invasion-percolation approaches for modeling large-scale geologic carbon sequestration

Most large-scale flow and transport simulations for geologic carbon sequestration (GCS) applications are carried out using simulators that solve flow equations arising from Darcy's law. Recently, the computational advantages of invasion-percolation (IP) modeling approaches have been presented. We show that both the Darcy's-law- and the gravity-capillary balance solved by IP approaches can be derived from the same multiphase continuum momentum equation. More specifically, Darcy's law arises from assuming creeping flow with no viscous momentum transfer to stationary solid grains, while it is assumed in the IP approach that gravity and capillarity are the dominant driving forces in a quasi-static two-phase (or more) system. There is a long history of use of Darcy's law for large-scale GCS simulation. However, simulations based on Darcy's law commonly include significant numerical dispersion as users employ large grid blocks to keep run times practical. In contrast, the computational simplicity of IP approaches allows large-scale models to honor fine-scale hydrostratigraphic details of the storage formation which makes these IP models suitable for analyzing the impact of small-scale heterogeneities on flow. However, the lack of time-dependence in the IP models is a significant disadvantage, while the ability of Darcy's law to simulate a range of flows from single-phase- and pressure-gradient-driven flows to buoyant multiphase gravity-capillary flow is a significant advantage. We believe on balance that Darcy's law simulations should be the preferred approach to large-scale GCS simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Capillary-Pumped Passive Reactor Concept for Space Nuclear Power

To develop the passively-cooled space reactor concept using the capillary-induced lithium flow, since molten lithium possesses a very favorable surface tension characteristic. In space where the gravitational field is minimal, the gravity-assisted natural convection cooling is not effective nor an option for reactor heat removal, the capillary induced cooling becomes an attractive means of providing reactor cooling.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Measurements of capillary system degradation

The effects of vibration, flow transients, and warm gas pressurization on capillary acquisition system performance were evaluated. The degradation observed under wide band random and high frequency sinusoidal vibration was of a substantially different nature from that obtained under low frequency sinusoidal vibration. With the former, ingestion of small gas bubbles into the liquid region was correlated by a hydrostatic model, while the capillary stability was destroyed and liquid was lost from the liquid region with the latter. No degradation was observed as a result of flow transients in a flight-type multichannel screen device, but it was observed in a transparent laboratory device. Liquid hydrogen outflow tests were conducted with a multilayer dual-screen-liner system with both helium and hydrogen pressurant gases. The tendency towards dryout of the device with hydrogen pressurant was found to increase with increasing pressurant temperature and length of prepressurization period. Dryout did not occur with helium pressurant.

Warren, R. P.↗

Revisiting Maxwell’s accommodation coefficient: A study of nitrogen flow in a silica microtube across all flow regimes

Gas flows have been studied quantitatively for more than a hundred years and have relevance in modern fields such as the control of gas inputs to processes, the measurement of leak rates and the separation of gaseous species. Cha and McCoy have derived a convenient formula for the flow of an ideal gas applicable across a wide range of Knudsen numbers (Kn) that approaches the Navier–Stokes equations at small Kn and the Smoluchowski extension of the Knudsen flow equation at large Kn. Smoluchowski’s result relies on the Maxwell definition of the tangential momentum accommodation coefficient α, recently challenged by Arya et al. We measure the flow rate of nitrogen gas in a smooth walled silica tube across a wide range of Knudsen numbers from 0.0048 to 12.4583. We find that the nitrogen flow obeys the Cha and McCoy equation with a large value of α, unlike carbon nanotubes which show flows consistent with a small value of α. Silica capillaries are therefore not atomically smooth. The flow at small Kn has α=0.91 and at large Kn has α close to one, consistent with the redefinition of accommodation coefficient by Arya et al., which also resolves a problem in the literature where there are many observations of α of less than one at small Kn and many equal to one at large Kn. Silica capillaries are an excellent choice for an accurate flow control system. - Highlights: • First experimental study on flow rate across all flow regimes in a well-defined microtube. • Extend Cha and McCoy theory for molecular flow regime. • Demonstrate the Maxwell accommodation coefficient is different in the slip and molecular flow regimes.

42 ENGINEERING↗

Polyimide processing additives

A method has been found for enhancing the melt flow of thermoplastic polyimides during processing. A high molecular weight 422 copoly(amic acid) or copolyimide was fused with approximately 0.05 to 5 pct by weight of a low molecular weight amic acid or imide additive, and this melt was studied by capillary rheometry. Excellent flow and improved composite properties on graphite resulted from the addition of a PMDA-aniline additive to LARC-TPI. Solution viscosity studies imply that amic acid additives temporarily lower molecular weight and, hence, enlarge the processing window. Thus, compositions containing the additive have a lower melt viscosity for a longer time than those unmodified.

Pratt, J. R.↗

Transmission in situ and operando high temperature X-ray powder diffraction in variable gaseous environments

In this paper, we describe a device for time-resolved synchrotron-based in situ and operando X-ray powder diffraction measurements at elevated temperatures under controllable gaseous environments. The respective gaseous sample environment is realized via a gas-tight capillary-in-capillary design, where the gas flow is achieved through an open-end 0.5 mm capillary located inside a 0.7 mm capillary filled with a sample powder. Thermal mass flow controllers provide appropriate gas flows and computer-controlled on-the-fly gas mixing capabilities. The capillary system is centered inside an infrared heated, proportional integral differential-controlled capillary furnace allowing access to temperatures up to 1000 °C.

36 MATERIALS SCIENCE↗

Centrifugal‐driven, reduced‐dimension, planar chromatography

Abstract A fundamental problem with efficiency in capillary action driven planar chromatography results from diminishing flow rates as development proceeds, giving rise to molecular diffusion related band dispersion for most sample types. Overpressure and electrokinetic means to speed flow have been used successfully in TLC. We explore the use of centrifugal force (CF) to drive flow for reduced‐dimension planar platforms (ultra‐TLC, low micrometer features, and nano‐TLC, nanoscale features). The silicon wafer platforms have two forms of continuous 2D arrays created by either photolithography or metal dewetting followed by deep reactive ion etching and coated with porous SiO 2 . The flow pattern is unusual with co‐planar flows above and within the arrays. The effects of parameters such as spin rate, solvent type, and surface character on flow rates is established and can be substantially greater than capillary action flow. Using fluorescent dyes, we investigate retardation factors and chromatographic plate height; the latter falls in the low to sub‐micrometer range. To the best of our knowledge, we demonstrate the first analytical separations performed in pillar arrays using CF to augment solvent flow.

Strickhouser, Rachel B.↗

Capillary and acceleration wave breakup of liquid jets in axial-flow airstreams

Empirical correlations of reciprocal mean drop diameter with airstream momentum were derived from capillary and acceleration wave breakup of liquid jets atomized by cross stream injection into axial flow airstreams. A scanning radiometer was used to obtain data over an airstream momentum range of 3.7 to 25.7 g/sq cm sec. Transition from capillary to acceleration wave breakup was obtained at a critical Weber-Reynolds number of 1,000,000.

Ingebo, R. D.↗

Quantification of ionic transport within thermally-activated batteries using electron probe micro-analysis

The transient transport of electrolytes in thermally-activated batteries is studied in this paper using electron probe micro-analysis (EPMA), demonstrating the robust capability of EPMA as a useful tool for studying and quantifying mass transport within porous materials, particularly in difficult environments where classical flow measurements are challenging. By tracking the mobility of bromine and potassium ions from the electrolyte stored within the separator into the lithium silicon anode and iron disulfide cathode, we are able to quantify the transport mechanisms and physical properties of the electrodes including permeability and tortuosity. Due to the micron to submicron scale porous structure of the initially dry anode, a fast capillary pressure driven flow is observed into the anode from which we are able to set a lower bound on the permeability of 10 -1 mDarcy. The transport into the cathode is diffusion-limited because the cathode originally contained some electrolyte before activation. Finally, using a transient one-dimensional diffusion model, we estimate the tortuosity of the cathode electrode to be 2.8 ± 0.8.

25 ENERGY STORAGE↗

Correlation of macro and micro cardiovascular function during weightlessness and simulated weightlessness

The investigation of cardiovascular function necessarily involves a consideration of the exchange of substances at the capillary. If cardiovascular function is compromised or in any way altered during exposure to zero gravity in space, then it stands to reason that microvascular function is also modified. We have shown that an increase in cardiac output similar to that reported during simulated weightlessness is associated with a doubling of the number of post-capillary venules and a reduction in the number of arterioles by 35%. If the weightlessness of space travel produces similar changes in cardiopulmonary volume and cardiac output, a reasonable expectation is that astronauts will undergo venous neovascularization. We have developed an animal model in which to correlate microvascular and systemic cardiovascular function. The microcirculatory preparation consists of a lightweight, thermo-neutral chamber implanted around intact skeletal muscle on the back of a rat. Using this technique, the performed microvasculature of the cutaneous maximus muscle may be observed in the conscious, unanesthetized animal. Microcirculatory variables which may be obtained include venular and arteriolar numbers, lengths and diameters, single vessel flow velocities, vasomotion, capillary hematocrit anastomoses and orders of branching. Systemic hemodynamic monitoring of cardiac output by electromagnetic flowmetry, and arterial and venous pressures allows correlation of macro- and microcirculatory changes at the same time, in the same animal. Observed and calculated hemodynamic variables also include pulse pressure, heart rate, stroke volume, total peripheral resistance, aortic compliance, minute work, peak aortic flow velocity and systolic time interval. In this manner, an integrated assessment of total cardiovascular function may be obtained in the same animal without the complicating influence of anesthetics.

NASA Discipline Number 00-00↗

Predictive models for moving contact line flows

Modeling flows with moving contact lines poses the formidable challenge that the usual assumptions of Newtonian fluid and no-slip condition give rise to a well-known singularity. This singularity prevents one from satisfying the contact angle condition to compute the shape of the fluid-fluid interface, a crucial calculation without which design parameters such as the pressure drop needed to move an immiscible 2-fluid system through a solid matrix cannot be evaluated. Some progress has been made for low Capillary number spreading flows. Combining experimental measurements of fluid-fluid interfaces very near the moving contact line with an analytical expression for the interface shape, we can determine a parameter that forms a boundary condition for the macroscopic interface shape when Ca much les than l. This parameter, which plays the role of an "apparent" or macroscopic dynamic contact angle, is shown by the theory to depend on the system geometry through the macroscopic length scale. This theoretically established dependence on geometry allows this parameter to be "transferable" from the geometry of the measurement to any other geometry involving the same material system. Unfortunately this prediction of the theory cannot be tested on Earth.

Rame, Enrique↗