Search NASA⌕ Search

SEARCH · Search NASA

Results for “communication system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Determining and Unlocking Untapped Demand-Side Management Potential in South Africa: Demand Response at the Grid Edge

The National Renewable Energy Laboratory (NREL), funded through the Climate Technology and Change Network (CTCN), has provided technical assistance to key energy sector entities in South Africa to examine untapped demand-side management potential. NREL partnered with the Council for Scientific and Industrial Research (CSIR) and included key South Africa stakeholders: Eskom, the South African National Energy Development Institute (SANEDI), and the Department of Mineral and Resources and Energy (DMRE), including the CTCN National Designated Entity (NDE), the Department of Science and Innovation (DSI). South Africa is currently experiencing an energy crisis with extensive load shedding. While the load shedding crisis in South Africa is a supply side problem, demand-side management provides opportunities to achieve energy efficiency and to reduce peak demand. DSM also has huge potential to help alleviate load shedding, which is a last resort form of DSM.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Active High Assurance Authentication Protocol (AHAAP)

The AHAAP Maturation Project involves maturation and evaluation of a patented zero-trust tamper-resistant high-assurance session-less dynamic and active device authentication protocol that simultaneously authenticates identity and provides integrity verification in a single step, substantially reducing the risk of cyberattack, and eliminating the need for costly and complex conventional communication security systems requirements (i.e., cryptography, Public Key Infrastructure (PKI), and key management). These cybersecurity attributes of the technology must be preserved when applying the technology to different cybersecurity solutions, including Command & Control (C&C), Over-the-Air (OTA) update, Common Access Card (CAC), and distributed energy resource (DER) implementations, among others. The technology research objective is to test and verify that the cybersecurity attributes of the technology are not degraded in different cybersecurity applications. The primary technology development objective is to build minimum viable products to demonstrate the technology addresses today’s cybersecurity threats so that prospective investors, strategic partners, regulatory agencies, and commercial customers can interact with and assess the protection assured by the technology. The AHAAP Maturation Project goal is to develop, test, and validate one or more AHAAP implementations. The AHAAP Maturation Project tasks are: (i) engineer AHAAP implementation software, (ii) build a functional prototype that implements the AHAAP software for demonstration, testing, analysis, and evaluation purposes, and (iii) generate a report detailing the results of the AHAAP C&C software and hardware implementation. The final project deliverables are: (i) AHAAP software implementation and prototype, (ii) a report from Sandia National Laboratories detailing the results of the AHAAP implementations.

97 MATHEMATICS AND COMPUTING↗

EVSE Characterization: V2G EVSE Comparison

As part of the U.S. Department of Energy EVs@Scale consortium Next-Generation Profiles project, results and analysis from the characterization of high-power conductive and wireless charging infrastructure are presented. This characterization is conducted over a wide range of direct current (DC) current and DC voltage operation for nominal test conditions and off-nominal test conditions. Test plans and procedures were developed to define the test configurations and requirements, measurement parameters, and test procedures used throughout testing. Results from a 2024 study conducted on electric vehicle supply equipment (EVSE) characterization by the Idaho National Laboratory (INL) include two bi-directional vehicle-to-grid (V2G) capable EVSEs. These EVSE are referred to as V2G-EVSE9 and V2G-EVSE10. Laboratory testing is conducted at nominal test conditions to characterize the power transfer capabilities, efficiency, power factor, and other power quality metrics of the two DC EVSEs capable of V2G bi-directional power transfer. Results from testing show the performance is consistent for V2G-EVSE9 and V2G-EVSE10 when comparing charging to discharging performance, except for V2G-EVSE10 for power transfer when operating above 70% of the rated DC current. V2G-EVSE10 efficiency is >98% while charging and <91% while discharging at the same operating conditions, near maximum-rated current, at 300VDC. In contrast, V2G-EVSE9 results are consistent for charging and discharging. This EVSE is nearly 96% efficient while charging or discharging when operating over 50% of rated AC power. V2G EVSE performance is also characterized during off-nominal AC grid conditions involving AC voltage deviation (426 VAC to 518 VAC), AC frequency deviation of +2% (58.8 Hz to 61.2 Hz), and AC voltage harmonics injection. Many test conditions have little-to-no impact on performance characteristics of the two EVSEs; however, there are a few notable findings with significant power transfer capability impacts. AC voltage harmonics injection resulted in negative impacts on power quality attributes for both EVSEs, but with no impact on power transfer capability. Off-nominal AC voltage and frequency conditions resulted in unstable or lack of power transfer capability for both EVSEs. V2G-EVSE9 is unable to transfer power when AC voltage is >300V L-N. V2G-EVSE10 is unable to transfer power when AC frequency deviation exceeds +0.8%. V2G energy management system transient response and latency are quantified during laboratory testing. V2G-EVSE9 and V2G-EVSE10 utilize cloud-based V2G energy management systems that command the power transfer level between the EVSE and EV. The latency and response characteristics of the entire systems (web-based user interface, V2G energy management system, cellular communications, and EVSE response) are quantified through laboratory testing for V2G-EVSE9 and V2G-EVSE10. V2G-EVSE9 latency ranges from 0.8 to 1.8 seconds, whereas V2G-EVSE10 latency ranges from 3.4 to 8.8 seconds. The ramp rate to a change in power transfer request also differs between the two EVSEs. V2G-EVSE10 ramp rate ranges from 50% to -250% of rated AC power per second, whereas V2G-EVSE9 rate ranges from 95% to -95% of rated AC power per second. At the highest rate of change in power transfer, V2G-EVSE10 can change from full charge power to full discharge power in less than one second. The V2G EVSE characterization presented in this report provides valuable insights and results for use by numerous entities. This includes modeling and simulation organizations, decision makers, fleet planning, industry stakeholders, and many others involved with the development and deployment of electrified transportation technologies. Additional high-power DC chargers, bidirectional chargers, and inductive power transfer EVSE characterization results are anticipated from additional EVSE brands and models, which will be detailed in future publications in support of the U.S. Department of Energy EVs@Scale consortium Next-Gen Profiles project.

25 ENERGY STORAGE↗

Cooperative Systems in Presence of Cyber-Attacks: A Unified Framework for Resilient Control and Attack Identification

Here, this paper considers a cooperative control problem in presence of unknown attacks. The attacker aims at destabilizing the consensus dynamics by intercepting the system’s communication network and corrupting its local state feedback. We first revisit the virtual network based resilient control proposed in our previous work and provide a new interpretation and insights into its implementation. Based on these insights, a novel distributed algorithm is presented to detect and identify the compromised communication links. It is shown that it is not possible for the adversary to launch a harmful and stealthy attack by only manipulating the physical states being exchanged via the network. In addition, a new virtual network is proposed which makes it more difficult for the adversary to launch a stealthy attack even though it is also able to manipulate information being exchanged via the virtual network. A numerical example demonstrates that the proposed control framework achieves simultaneously resilient operation and real-time attack identification.

97 MATHEMATICS AND COMPUTING↗

Systems, devices and methods for communicating data with unmanned aerial vehicles using underlay broadcast channel

An unmanned aerial vehicle (UAV) and base station are disclosed that communicate within a first cell via schedule requests to set up transmission of up-link data. The UAV additionally communicates up-link data via a grant-free underlay broadcast channel to one or more neighboring base stations of the terrestrial cellular network. Transmitters, receivers, related methods are also disclosed for modulation and demodulation of the transmission packets.

Moradi, Hussein↗

Arrangements for communicating data in a computing system using multiple processors

Systems and methods for reducing data movement in a computer system. The systems and methods use information or knowledge about the structure of an algorithm, operations to be executed at a receiving processing unit, variables or subsets or groups of variables in a distributed algorithm, or other forms of contextual information, for reducing the number of bits transmitted from at least one transmitting processing unit to at least one receiving processing unit or storage device.

Gonzalez, Juan Guillermo↗

Assessing Solar Cybersecurity: Questions for States to Ask Electric Utilities

To help State Energy Officials and Public Utility Commissions engaging investor-and consumer-owned utilities and the solar industry in topical discussions about their cybersecurity practices and priorities in general, and for interconnected solar systems, specifically, this report outlines discussions prompts for these discussions. By using the questions in this tool states can explore aspects of utilities’ cybersecurity risk management programs that target solar devices, systems, and communication pathways. Such discussions help states identify cybersecurity gaps and assist in emergency response planning, as well as general risk awareness.

14 SOLAR ENERGY↗

Vector send operation for message-based communication

Methods and systems for conducting vector send operations are provided. The processor of a sender node receives a request to perform a collective send operation (e.g., MPI_Broadcast) from a user application, requesting a copy of data in one or more send buffers by sent to each of a plurality of destinations in a destination vector. The processor invokes a vector send operation from a software communications library, placing a remote enqueue atomic send command for each destination node of the destination vector in an entry of a transmit data mover (XDM) command queue in a single call. The processor executes all of the commands in the XDM command queue and writes the data in the one or more send buffers into each receive queue of each destination identified in the destination vector.

Byrne, John L.↗

System and method for characterization of air leakage in building using data from communicating thermostats and/or interval meters

Systems and methods for characterization of retrofit opportunities are described. Some embodiments are directed to methods for determining the air leakage rate of a building, and accordingly, for determining suitability of sealing of air leaks to improve the energy efficiency of a building. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter. To isolate the impact of air leakage, subsets of the HVAC runtime data at time intervals selected to have substantially the same conditions, but different wind speeds, may be computed.

Zeifman, Michael↗

Peer-to-peer communication control for resilient operations of networked cyberphysical systems

This report includes two main accomplishments of the peer-to-peer communication control for resilient operation of networked microgrids project in FY24, which include a scheme for cyberattack-aware coordination of networked microgrids for supporting voltages of bulk power systems and a scheme for price signal-based operations of EV-rich networked microgrids with mixed ownership. First, the cyberattack-aware scheme enables networked microgrids to distributedly determine the amount of reactive power injection to support the voltage of bulk power system (BPS) in a fair manner. In this scheme, a risk-informed algorithm is presented to generate the peer-to- peer (P2P) communication graph with minimal risk of attack on communication links. To deal with cyberattacks on MG controllers, the resilient consensus algorithm (CA) is utilized for MG controllers to robustly estimate the total reactive power headroom, from which the MGs can accurately provide the needed amount of reactive power injection for supporting the voltage of BPS. The CA implementation and performance within the P2P communication framework are demonstrated on the IEEE 39-bus system with 6 microgrids contained in the distribution feeder under different cyberattack scenarios. Second, the price-based scheme enables the usage of the real-time price signal for the operations of electric vehicle (EV)-rich networked-microgrids with mixed ownership, in which not all the microgrids can communicate with the distribution system operator (DSO). In this scheme, a max consensus is introduced to enable the real-time price signal to be propagated from the DSO to all the microgrids, from which each microgrid controller will manage the DERs to balance the load demand and the power injection from the EV charging stations within its microgrid. Numerical results over one day with 288 slots of 5-minute intervals on the modified 123-node test feeder including 3 microgrids with high penetration of EV are presented to evaluate how the price signal affects the operations of networked microgrids under different charging strategies of the EV charging stations. The result indicates that our proposed EVCS (dis)charging strategy, which leverages the flexibility of EVs to support the grid through discharging during peak demand, proves to be a cost-effective solution that reduces operational costs while improving the social welfare of EV charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed fiber-optic sensor network for sensing the corrosion onset and quantification

Materials, methods of making, and methods of sensing liquid droplets with high spatial resolution as a signature of the on-set of corrosion using a hierarchical sensor network A hierarchical sensor network for sensing liquid droplets with high spatial resolution as a signature of the on-set of corrosion, including an interrogation system; and an intermediate sensor array layer in communication with the interrogation system. The network includes an interrogation system and an intermediate sensor array layer in communication with the interrogation system.

Ohodnicki, Paul R.↗

Scaled-up Neuromorphic Array Communications Controller (SNACC) for Large-scale Neural Networks

Neuromorphic computing is one promising post-Moore’s law era technology, which takes inspiration from biological brains to perform computing tasks. The human brain contains billions of neurons with trillions of synapses and as neuromorphic hardware systems scale to larger and larger sizes, the communication system used to transfer information between neuromorphic elements and traditional computers must scale to keep up. In prior work, we describe the use of a separate neuromorphic array communications controller to support low-latency, high-throughput communication between our neuromorphic systems and a traditional computer. In this work, the neuromorphic array communications controller is used to support the scaling of a neuromorphic development system which uses multiple neuromorphic processors arranged in a two-dimensional array. The neuromorphic array communications controller, along with scalable local connections, is used to create a scalable neuromorphic platform to enable the development and testing of large neuromorphic network arrays.

Young, Aaron↗

Peer-to-peer Communication Control Architecture for Engaging Ubiquitous DERs to Support Distribution System Resiliency

In this project, we developed a leader-follower consensus (LFC) control architecture to coordinate between GFM and GFL inverters with the former being leaders and the latter being followers. The objective is to simultaneously achieve a fast frequency and voltage regulation along with accurate real power and var sharing among all inverters under various disturbances. The distinction of our work is that we consider both GFM and GFL inveters for frequency and voltage regulations. In addition, rather than a standard consensus algorithm, our work utilized a leader-follower consensus algorithm which exploits the physical characteristics of GFM-GFL inverters: (i) the GFM inverters directly control frequency and voltage, and hence, serve as leaders, (ii) the GFL inverters measure frequency/voltage to modulate their outputs, and hence, they should serve as followers. The effectiveness of the proposed LFC coordination was tested on a networked microgrid test system under different disturbances and communication degradation events. We demonstrated that the proposed fully coordinated control is robust to disturbances, while outperforming uncoordinated and GFM-only coordinated approaches. Overall, this work emphasized the necessity and benefits of the GFMGFL coordination in the secondary control of microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Influence of Communication on the Complexity of Connected Lighting Systems

Experience in the Next Generation Lighting Systems (NGLS) ”Living Lab” at the Parsons School of Design, has clearly shown the impacts of communication on the configuration complexity of the connected lighting systems installed there. Since 2017, NGLS has invited manufacturers to submit connected lighting systems for assessment against a set of specifications. To date, 14 systems of wirelessly connected LED luminaires and controls have been installed in classrooms with existing lighting. In nine of the rooms, new LED linear pendants or recessed troffers replaced existing luminaires; in the other rooms, LED “kits” were retrofitted into the existing troffers. Eleven of the installations featured sensors integrated in the luminaires or retrofit kits; the others used ceiling mounted sensors. All systems provided wall control devices for manual operation. For half of the installations, the complete systems were furnished by single companies; for the other half, luminaires and controls were furnished by separate companies. A total of 18 different companies provided products, with four of these located outside the United States including, Korea, Poland, Germany, and the Netherlands. In addition, two different electrical contractors in New York City provided multiple installation teams totaling 10 individuals, none of whom were familiar with any of the systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

900-MHz LTE network↗