Search NASA⌕ Search

SEARCH · Search NASA

Results for “compressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Equipment List Comparing Balance of Plant Containing a Heat Pump against a Reference Electricity Generating Plant

Approximately two-thirds of U.S. energy consumption in the industrial and transportation sectors relies on fossil fuels. These sectors require high-quality heat, i.e., thermal energy at very high temperatures, for molecular transformation processes. The Integrated Energy Systems (IES) program aims to assess the economic potential of utilizing nuclear-grade heat from Advanced Reactors (ARs) to meet the high-quality heat demands. By having industrial processes (IPs) supplied with nuclear-generated heat, manufacturers could benefit from more stable and potentially lower energy costs, reducing reliance on volatile fossil fuel markets. The main outcome of the FY24 research was the thermodynamic assessment and gap analysis of steam generation for IP applications. The study completed in June 2024 demonstrated that the required steam temperatures could be achieved by integrating a heat pump into an AR power plant. After identifying the thermal demands of target IPs, multiple balance of plant configurations for the Xe-100 reactor by X-energy, incorporating a heat pump, were analyzed. Their technical feasibilities were assessed, including the design of suitable axial compressors for these applications. Comparative performance analysis showed that thermal efficiency alone is insufficient to evaluate system suitability. To address this, a new indicator (heat factor) was introduced in the report released in September 2024 to quantify the low-quality thermal power needed to produce one unit of high-quality heat for the IP. Results showed that integrating heat pumps into Rankine cycles enables higher steam temperatures, though at the expense of increased thermal energy input. This report builds upon and completes the foundational work previously undertaken. It focuses on the design of two Balance of Plant (BOP) configurations, both based on Rankine energy conversion cycles: “Case 1”, which involves electricity generation only, and “Case 2”, which combines electricity and high-temperature heat generation for industrial use. For each configuration, a comprehensive equipment list was developed, detailing all major components such as turbines, compressors, heat exchangers, pumps, and control systems. These lists will serve as the basis for future comparative cost analyses, with the goal of assessing the number and type of components required to integrate a heat pump into the Rankine cycle and to establish a heat transport system capable of delivering thermal energy from the nuclear plant to an industrial facility. Using the constitutive equations presented in the June 2024 milestone, the operating conditions of all BOP components for both “Case 1” and “Case 2” were evaluated. These parameters—such as temperature, pressure, mass flow rate, and steam quality—served as the basis for calculating the associated thermal and mechanical power flows. The net power required from the heat pump to raise the steam temperature to the target level was also determined. The thermodynamic performance of the configuration was then assessed using the heat factor metric. The key outcome of this analysis is a comparative table that presents the equipment that was used in the “Case 1” and “Case 2” configurations. This study offers a preliminary comparison of the two designs, providing insight into the impact of integrating a heat pump in terms of component requirements and thermal efficiency. This equipment list, together with the evaluated operating conditions, also serves as a foundation for the economic analyses scheduled for the current fiscal year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Automatic Generation of Algorithms for High-Speed Reliable Lossy Data Compression (Final Report)

Fast reliable data compression is urgently needed for many leading-edge scientific instruments and for exascale high-performance computing applications because they produce vast amounts of data at extremely high rates. The goal of this project has been to develop a framework named LC that is able to automatically generate high-speed lossless and reliable lossy compression and decompression algorithms that can be customized for different kinds of data. The resulting LC framework is freely available on GitHub. To achieve high-speed operation, LC outputs optimized and parallelized CPU and GPU implementations of the generated algorithms. To ensure the quality of lossily compressed data, LC guarantees the user-provided error bound. To be able to customize the compression algorithm to various use cases, LC can synthesize millions of different algorithms and automatically search for the one that works best for the given data. We have already employed LC to create state-of-the-art lossless and lossy compressors for scientific data as well as leading lossless compressors for images. We hope that LC and the customized, fast, reliable, and CPU/GPU-compatible compression algorithms that it can generate will greatly benefit the many scientific applications that need not only high trustworthiness but also high performance.

97 MATHEMATICS AND COMPUTING↗

Charge Reduction and Performance Analysis of a Heat Pump Water Heater Using R290 as a Refrigerant—A Field Study

Heat pump water heaters (HPWHs) are a proven technology for water heating that has been commercialized. The adoption of HPWHs for domestic and commercial water heating is growing rapidly because of their superior performance compared with alternative water heating methods. Whereas most existing systems use R-134a as a working refrigerant, R290 has gained major attention owing to its superior thermodynamic properties. The goal of the current study is to assess the performance of residential HPWH with R290 as a direct refrigerant replacement for R134a. Two units of a 50 gal HPWH were used in this experimental study. A baseline unit contained R134a refrigerant, and a prototype unit contained R290 refrigerant. The prototype unit was developed through the modification of a commercially available HPWH unit to achieve a low charge of R290 refrigerant. Another major modification was the replacement of the baseline compressor with a compressor designed for R290. Tests were conducted in a field environment (a research and demonstration house) using programmed drawn profiles daily. The prototype that reduced the charge by 43–47% provided displayed performance comparable to the baseline unit regarding first-hour rating (FHR) and the uniform energy factor (UEF).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Calculating Methane Emissions from Offshore Facilities Using Bottom-Up Methods

With changing demands in regulation, understanding methane emissions from offshore oil and gas production infrastructure has become increasingly important. Reported emissions from facilities in the Gulf of Mexico range from zero to thousands of tons of methane per hour, but these is currently no clear understanding of how this range compares to expected emissions from normally operating facilities. To generate realistic emission estimates, we create two bottom-up models that simulate emissions from facilities operating in the Gulf of Mexico. We estimate type 1 prototypical facilities (typically unmanned, older, lower-producing platforms in shallow water with little processing equipment, compressors, or storage tanks) to emit an average of 13 kg CH 4 h −1 , which corresponds to a loss of 2.7% of the average facility production. Type 2 prototypical facilities (continuously manned, higher production and operate in deeper water with processing equipment, oil storage tanks, compressors and power generation) emit an average of 88 kg CH 4 h −1 , which corresponds to a loss of 2.5% of production. The average measured emission from type 1 facilities was 18 kg CH 4 h −1 with a median production loss estimated at 8%. The average measured emission from type 2 facilities was 36 kg CH 4 h −1 with a median production loss estimated at 2.4%. Using emission factors that consider the long-tail emission distribution partly reconciles the difference between modelled and measured emission estimates, but we suggest the current the fugitive emission estimate may be an underestimate and more data on the number and size of fugitive emissions could explain differences between the modelled and measured emission estimate. We suggest the bottom-up approach described here that uses production data coupled with facility equipment could be used to identify facilities that have abnormally large measured emissions, caused by methodological failure or larger than expected fugitive emissions, which should be targeted for further evaluation resulting in remeasurement or identification of source type so that a more accurate estimates can be made on the absolute emission.

bottom-up↗

Operational Experience of the NML Cryogenic Plant at the FAST Test Facility

The NML cryogenic plant cools two individually cryostated superconducting radio frequency (SRF) capture cavities and one prototype ILC cryomodule with eight SRF cavities. This complex accelerates electrons at 150 MeV for the Integrable Optics Test Accelerator (IOTA) ring, located at the Fermilab Accelerator Science and Technology (FAST) facility. The cryogenic plant is composed of two nitrogen precooled Tevatron satellite refrigerators, two Mycom 2016C compressors, a cryogenic distribution system, a Frick purifier compressor, two charcoal bed adsorber purifiers, and a liquid ring vacuum pump with a roots booster. The SRF cavities are immersed in a 2.0 K liquid helium bath, shielded with a 5 K gaseous helium shield and a liquid nitrogen cooled thermal shield. Since 2019, this R&D accelerator complex has gone through four science runs with an average duration of 12 months. Operational experience for each run, availability metrics, performance data and common outages are presented in this paper.

Wallace, Timothy [Fermilab] (ORCID:000900051589302↗

Scroll-type machine

A scroll-type displacement machine, e.g. scroll compressor, has fixed and orbiting scrolls and an Oldham ring to prevent relative rotation between scrolls. A drive module positioned between the orbiting scroll and drive shaft incorporates an eccentric drive system and first and second counterweights for dynamic balancing. The motor, motor bearings, and motor shaft (i.e., drive shaft) are packaged as a separate, modular unit (e.g. “off-the-shelf” motor) that attaches to the compressor frame. The machine is configured as a high-side machine with a low-pressure port at a radial outer portion of the fixed scroll and a high-pressure port or discharge port located in the floor of the orbiting scroll at its axis, with high pressure flow passing over and around the eccentric drive bearing and drive mechanism. The Oldham ring is distributed on a lateral or radial plane of the scroll pair with a portion surrounding a portion of the fixed scroll and another portion surrounding a portion of the orbiting scroll. The ring may be formed as four arcuate members arranged on two levels, to occupy otherwise unused space in the scroll-type machine.

42 ENGINEERING↗

Residential Split Heat Pump Using Low GWP Refrigerants

Conventional refrigerants, e.g. R-410A have high global warming potentials (GWP) > 1800. They are being phased out to protect the environment. The candidates to replace R-410A include R-32, R-452B, R-454B and R-466A for heat pump applications. These candidates are intended for drop-in replacement, i.e. having minimum modifications on existing systems. The paper investigates the low GWP refrigerants drop-in application via system simulations using a well-regarded, hardware-based heat pump model. A baseline heat pump having all fin-and-tube heat exchangers and a two-speed compressor was used. Cross-comparisons were made under rated conditions of ambient temperatures, compressor speeds, indoor air flow rates, respectively for cooling and heating operations. The seasonal performance indices, i.e. SEER and HSPF are presented.

Shen, Bo↗

Closed cycle heat engine

Heat engines employing fluid bearing assemblies hermetically sealed with a closed flowpath for a working fluid are generally disclosed. For example, the heat engine includes a rotating drivetrain and a fluid bearing assembly. The rotating drivetrain includes a compressor section, an expander section, and a heat exchanger. The compressor section and expander section together define at least in part a closed flowpath for the flow of a working fluid. The heat exchanger is thermally coupled to the closed flowpath for adding heat to the working fluid. The fluid bearing assembly is configured to utilize the working fluid to support the rotating drivetrain. Further, the fluid bearing assembly is hermetically sealed with the closed flowpath.

Ertas, Bugra Han↗

Cooling systems having an integrated ionic liquid salt dehumidification system

A cooling systems utilizes an organic ionic salt composition for dehumidification of an airflow. The organic ionic salt composition absorbs moisture from an inlet airflow to produce an outlet airflow with a reduce moisture from that of the inlet airflow. The organic ionic salt composition may be regenerated, wherein the absorbed moisture is expelled by heating with a heating device. The heating device may be an electrochemical heating device, such as a fuel cell, an electrochemical metal hydride heating device, an electrochemical heat pump or compressor, or a condenser of a refrigerant cycle, which may utilize an electrochemical pump or compressor. The efficiency of the cooling system may be increased by utilization of the waste heat the cooling system. The organic ionic salt composition may circulate back and forth or in a loop between a conditioner, where it absorbs moisture, to a regenerator, where moisture is desorbed by heating.

Bahar, Bamdad↗

High Efficiency Heat Pumps Can Pave the Path for Building Decarbonization in Cold Climates: Preprint

Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.

cold climate heat pump↗

An Update on the Status of a Reduced Flow Test of a 10MW 700°C sCO2 Integrally Geared Compander

. In order to maintain viability as a future power-generating technology, concentrating solar power (CSP) must reduce its levelized cost of electricity (LCOE). One component of solving this problem is reducing the cost of the power block while simultaneously increasing the efficiency of the thermodynamic cycle. One disruptive technology that has the promise to accomplish this is supercritical CO2 based power cycles. These cycles are conceptually similar to steam cycles; however, they have substantially smaller turbomachinery at equivalent power while also delivering more efficiency at turbine inlet temperatures of 500-700 degrees Celsius. This paper will summarize the current status of a US Department of Energy project to develop machinery to support a 10 MW sCO2 power cycle. The team of Southwest Research Institute® (SwRI®) and Hanwha Power Systems America, proposed to develop an integrally-geared (IG) compressor-expander (compander) for use in a nominal 10 MW-scale concentrated solar power (CSP) supercritical carbon dioxide (sCO2) plant application. This integrally-geared compander (IGC) comprises multiple pinion shafts interconnected on a single bull gear to create a compact package, and utilizes a low-cost, low-speed driver. In addition, the integrally geared architecture allows each pinion to operate at different rotational speeds to optimize performance and easily allow for inter-stage cooling and turbine re-heat to further enhance both stage and cycle efficiency. The close integration of all turbomachinery elements into a single integrally-geared (IG) machine creates a design that lends itself to power block modularization, which makes it suitable for waste heat recovery, fossil fuel power plants, and especially CSP applications. As part of the commercialization of this technology, it is necessary to reduce risk by validation testing of key components. In the current work, the focus is developing a test loop to enable safe testing of the main compressor stage across a wide range of operating conditions, and to validate the mechanical integrity of the turbine at full pressure, temperature, and speed. Developing a test loop for sCO2 requires balancing a number of design alternatives that impact cost, lead time, safety, and performance. The current work discusses the design process for the reduced flow test loop for the compander, and supporting documentation supporting the viability of the test loop

wilkes, jason↗

Development and Test Progress Towards a Supercritical Carbon Dioxide-Based Gas Turbine Waste Heat Recovery System

Supercritical carbon dioxide systems are the focus of significant recent research efforts and promise compact, high-efficiency architecture for gas turbine waste heat recovery for pipeline gas turbines. The waste heat recovery system improves operating efficiency by converting waste heat to additional electric power, which increases overall system efficiency by 35% at the design point, and also significantly improves part-load performance. This paper describes the system design and component selection for a 5.7 MWe waste heat recovery system based on an integrally-geared compressor-expander architecture, including the thermodynamic cycle development, system architecture and component trade studies, and final selection. Validation test results for critical first-of-a-kind compressor and turbine component technologies are also presented, demonstrating full-pressure performance and progress towards commercialization.

wilkes, Jason↗

Exploration of Heat-Driven Ejector High-Temperature Heat Pumps

Heat-driven ejector heat pumps use a supersonic ejector as a thermo-compressor to replace the mechanical compressor. Supersonic ejectors have many advantages in high-temperature heat pump (HTHP) applications, including high operating temperature tolerance, no need for lubrication, low maintenance, and low cost. The coefficient of performance of ejector HTHPs could be improved by selecting binary fluids with unique thermodynamic properties. Although supersonic ejectors have been widely used in refrigeration systems, their application in spaces and water heating is limited. This study explores the theoretical potential of ejector HTHPs with a sink temperature of 100°C–130°C and a lift temperature of 10°C–30°C. Ejector HTHPs were evaluated with single-fluid ejectors (SFEs) and binary-fluid ejectors (BFEs). A comprehensive, geometry-free theoretical model of BFEs was developed to predict the theoretical maximum entrainment ratios. HFE7500 and R718 (water) were selected as working fluids for SFEs and BFEs. SFEs operating with R718 provided a higher coefficient of performance of ejector HTHPs than SFEs operating with HFE7500 and BFEs. This study preliminarily demonstrates the technical potential of ejector HTHP applications in recovering moderate-temperature heat sources

Wang, Pengtao↗

A Propane Hydronic Heat Pump with Energy Storage

Propane is an environment-friendly refrigerant, having a 20-year GWP (global warming potential) of 0.072 and a 100-year GWP of 0.02, as compared to R-410A having a GWP > 2000. It has superior thermodynamic cycle performance and heat transfer characteristics. However, propane is classified as a A3 refrigerant, which is highly flammable, and not allowed to be used indoor if the system charge is higher than 150 grams. It is a challenge to use propane in residential applications requiring a rated capacity larger than 10 k Watts. A hydronic heat pump, i.e., containing propane in an outdoor unit and distributing the cooling and heating capacity through a hydronic coil to the indoor space addresses the flammability issue, while maintaining a high efficiency. We developed a hydronic heat pump with propane, it uses a two-stage compressor, a brazed plate indoor heat exchanger, and a microchannel outdoor heat exchanger. It achieves a rated cooling capacity larger than 10 k Watts, and a cooling SEER (cooling seasonal energy efficiency rating) > 16.0 (cooling seasonal COP > 4.7) and a heating HSPF (heating seasonal performance factor) > 9.5 (heating seasonal COP > 2.78), while requiring a system charge < 1200 grams. Additionally, the hydronic heat pump was evaluated in a laboratory water heating loop to heat a 50-gallon water tank in a full condensing mode. Experiments of heating the tank water from 58F(14.4°C) to 150F(65.6°C) were conducted under ambient temperatures from 17F(-8.3°C) to 75F(23.9°C), at the compressor high and low stages.

Shen, Bo↗

Basement rock hybrid drilling

A system for monitoring and controlling downhole pressure of a well borehole relative to a lithostatic pressure of rock surrounding the borehole is provided. The system can include a millimeter wave drilling apparatus including a gyrotron configured to inject millimeter wave radiation energy into a borehole of a well via a waveguide configured for insertion into the borehole. The borehole can be formed via the millimeter wave drilling apparatus and having a downhole pressure monitored at a bottom of the well. The system can also include a compressor fluidically coupled to the borehole and configured to control the downhole pressure via a gas supplied into and/or received from the borehole. The compressor can be configured to control the downhole pressure relative to a lithostatic pressure determined for rock surrounding the well at the bottom of the well.

Araque, Carlos↗

Cooling systems having an integrated ionic liquid salt dehumidification system

A cooling system utilizes an organic ionic salt composition for dehumidification of an airflow. The organic ionic salt composition absorbs moisture from an inlet airflow to produce an outlet airflow with a reduce moisture from that of the inlet airflow. The organic ionic salt composition may be regenerated, wherein the absorbed moisture is expelled by heating with a heating device. The heating device may be an electrochemical heating device, such as a fuel cell, an electrochemical metal hydride heating device, an electrochemical heat pump or compressor, or a condenser of a refrigerant cycle, which may utilize an electrochemical pump or compressor. The efficiency of the cooling system may be increased by utilization of the waste heat the cooling system. The organic ionic salt composition may circulate back and forth or in a loop between a conditioner, where it absorbs moisture, to a regenerator, where moisture is desorbed by heating.

Bahar, Bamdad↗

System and operation for thermochemical renewable energy storage

Systems and methods for energy storage and energy recovery are provided. An electrical-to-electrical energy storage system includes a thermochemical energy storage device, a blower, a compressor, a turbine, and an electrical generator. The TCES device includes a vessel, a porous bed, and a heater. The porous bed is disposed within an interior volume of the vessel. The porous bed comprises a reactive material. The reactive material is configured to release oxygen upon being heated to a reduction temperature, and generate heat when exposed to oxygen. The heater is in thermal contact with the reactive material. The blower is configured to remove oxygen from the interior volume. The compressor is configured to flow oxygen into the interior volume. The turbine is configured to receive a heated, oxygen-depleted gas from the interior volume. The generator is configured to be powered by the turbine to generate electricity.

Klausner, James F.↗

Efficient turbine engine using integrated ammonia fuel processing

A gas turbine engine includes a core engine that includes a core flow path where air is compressed in a compressor section, communicated to a combustor section, mixed with an ammonia based fuel and ignited to generate a high energy combusted gas flow that is expanded through a turbine section. The turbine section is mechanically coupled to drive the compressor section. An ammonia flow path communicates an ammonia flow to the combustor section. A cracking device is disposed in the ammonia flow path. The cracking device is configured to decompose the ammonia flow into a fuel flow containing hydrogen (H2). At least one heat exchanger is upstream of the cracking device that provides thermal communication between the ammonia flow and a working fluid flow such that the ammonia fluid flow accepts thermal energy from the working fluid flow.

Smith, Lance L.↗