Search NASA⌕ Search

SEARCH · Search NASA

Results for “conditionally specified models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Virtual Design Studio (VDS) - Development of an Integrated Computer Simulation Environment for Performance Based Design of Very-Low Energy and High IEQ Buildings

Executive Summary The objective of this study was to develop a “Virtual Design Studio (VDS)”: a software platform for integrated, coordinated and optimized design of green building systems with low energy consumption, high indoor environmental quality (IEQ), and high level of sustainability. This VDS is intended to assist collaborating architects, engineers and project management team members throughout from the early phases to the detailed building design stages. It can be used to plan design tasks and workflow, and evaluate the potential impacts of various green building strategies on the building performance by using the state of the art simulation tools as well as industrial/professional standards and guidelines for green building system design. Engaged in the development of VDS was a multi-disciplinary research team that included architects, engineers, and software developers. Based on the review and analysis of how existing professional practices in building systems design operate, particularly those used in the U.S., Germany and UK, a generic process for performance-based building design, construction and operation was proposed. It distinguishes the whole process into five distinct stages: Assess, Define, Design, Apply, and Monitoring (ADDAM). The current VDS is focused on the first three stages. The VDS considers building design as a multi-dimensional process, involving multiple design teams, design factors, and design stages. The intersection among these three dimensions defines a specific design task in terms of “who”, “what” and “when”. It also considers building design as a multi-objective process that aims to enhance the five aspects of performance for green building systems: site sustainability, materials and resource efficiency, water utilization efficiency, energy efficiency and impacts to the atmospheric environment, and IEQ. The current VDS development has been limited to energy efficiency and IEQ performance, with particular focus on evaluating thermal performance, air quality and lighting environmental quality because of their strong interaction with the energy performance of buildings. The VDS software framework contains four major functions: 1) Design coordination: It enables users to define tasks using the Input-Process-Output flow approach, which specifies the anticipated activities (i.e., the process), required input and output information, and anticipated interactions with other tasks. It also allows task scheduling to define the work flow, and sharing of the design data and information via the internet. 2) Modeling and simulation: It enables users to perform building simulations to predict the energy consumption and IEQ conditions at any of the design stages by using EnergyPlus and a combined heat, air, moisture and pollutant simulation (CHAMPS) model. A method for co-simulation was developed to allow the use of both models at the same time step for the combined energy and indoor air quality analysis. 3) Results visualization: It enables users to display a 3-D geometric design of the building by reading BIM (building information model) file generated by design software such as SketchUp, and the predicted results of heat, air, moisture, pollutant and light distributions in the building. 4) Performance evaluation: It enables the users to compare the performance of a proposed building design against a reference building that is defined for the same type of buildings under the same climate condition, and predicts the percent of improvements over the minimum requirements specified in ASHRAE Standard 55-2010, 62.1-2010 and 90.1-2010. An approach was developed to estimate the potential impact of a design factor on the whole building performance, and hence can assist the user to identify areas that have most pay back for investment. The VDS software was developed by using C++ with the conventional Model, View and Control (MVC) software architecture. The software has been verified by using a simple 3-zone case building. The application of the VDS concepts and framework for building design and performance analysis has been illustrated by using a medium-sized, five story office building that received LEED Platinum Certification from USGBC.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy balance in the solar transition region. I - Hydrostatic thermal models with ambipolar diffusion

The energy balance in the lower transition region is analyzed by constructing theoretical models which satisfy the energy balance constraint. The energy balance is achieved by balancing the radiative losses and the energy flowing downward from the corona. This energy flow is mainly in two forms: conductive heat flow and hydrogen ionization energy flow due to ambipolar diffusion. Hydrostatic equilibrium is assumed, and, in a first calculation, local mechanical heating and Joule heating are ignored. In a second model, some mechanical heating compatible with chromospheric energy-balance calculations is introduced. The models are computed for a partial non-LTE approach in which radiation departs strongly from LTE but particles depart from Maxwellian distributions only to first order. The results, which apply to cases where the magnetic field is either absent, or uniform and vertical, are compared with the observed Lyman lines and continuum from the average quiet sun. The approximate agreement suggests that this type of model can roughly explain the observed intensities in a physically meaningful way, assuming only a few free parameters specified as chromospheric boundary conditions.

Fontenla, J. M.↗

The history of re-connection and the concept of the solar wind plasma with relatively small electrical conductivity

Petschek's 're-connection' model, aspiring to be universal, treated as a boundary problem meets unresolvable difficulties connected with impossibility to specify correctly boundary and initial conditions. This problem was incorrectly formulated. Hence, ineradicable logarithmic singularities occurred on the boundary surfaces. Attempts to eliminate them by incorporating the finite electrical conductivity are incorrect. This should lead to the change in the equation type, boundary condition type and in consequence to the change in solutions. Besides, the slow mode shocks cannot be driven by small internal source. As an alternative a new plasma concept is suggested. The state of fully ionized plasma in space depends completely on the entropy of the plasma heating source and on the process in which plasma is involved. The presumptive source of the solar wind creation - the induction electric field of the solar origin - has very low entropy. The state of plasma should be very far from the thermodynamic equilibrium. Debye's screening is not complete. The excitation of the powerful resonant self-consistent electric fields in plasma provides low electric conductivity. The MHD problems should be treated in frameworks of dissipative theories.

Chertkov, A. D.↗

Parametric analyses of single-zone thorium-fueled molten salt reactor fuel cycle options

Analyses of fuel cycle options based on thorium-fueled Molten Salt Reactors (MSRs) have been performed in support of fuel cycle screening and evaluation activities for the United States Department of Energy. The MSR options considered are based on thermal spectrum MSRs with 3 different separations levels: full recycling, limited recycling, and 'once-through' operation without active separations. A single-fluid, single-zone 2250 MWth (1000 MWe) MSR concept consisting of a fuel-bearing molten salt with graphite moderator and reflectors was used as the basis for this study. Radiation transport and isotopic depletion calculations were performed using SCALE 6.1 with ENDF/B-VII nuclear data. New methodology developed at Oak Ridge National Laboratory (ORNL) enables MSR analysis using SCALE, modeling material feed and removal by taking user-specified parameters and performing multiple SCALE/TRITON simulations to determine the resulting equilibrium operating conditions. Parametric analyses examined the sensitivity of the performance of a thorium MSR to variations in the separations efficiency for protactinium and fission products. Results indicate that self-sustained operation is possible with full or limited recycling but once-through operation would require an external neutron source. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Global land model development: time to shift from a plant functional type to a plant functional trait approach (Final Report)

This project advanced global land models by shifting from the current plant functional type approach to one that better utilizes what is known about the importance and variability of plant traits, within a framework of simultaneously improving fundamental physiological relations that are at the core of model carbon cycling algorithms. A primary goal for Earth system modeling is to make accurate predictions of the future trajectory of the climate system, based on a mechanistic understanding of processes regulating fluxes of mass and energy among system components. Land plays an important role in modifying the Earth’s mass and energy balance, as a critical link in the global cycling of carbon, among others. Land surface models have developed to include mechanistic representations of vegetation physiology, carbon and nutrient dynamics in plants and soils, how they might respond to changing climate and chemistry, and how those changes might feedback to influence changes in atmospheric greenhouse gases themselves. Existing models represent the global distribution of vegetation types using the Plant Functional Type concept. Plant Functional Types are classes of plant species with similar evolutionary and life history with presumably similar responses to environmental conditions like CO 2 , water and nutrient availability. Fixed properties for each Plant Functional Type are specified through a collection of physiological parameters, or traits. These traits, mostly physiological in nature (e.g., leaf nitrogen and longevity) are used in model algorithms to estimate ecosystem properties and/or drive calculated process rates. In most models, 5 to 15 functional types represent terrestrial vegetation; in essence, they assume there are a total of only 5 to 15 different kinds of plants on the entire globe. This assumption of constant plant traits captured within the functional type concept has serious limitations, as a single set of traits does not reflect trait variation observed within and between species and communities. While this simplification was necessary decades past, substantial improvement is now possible. Rather than assigning a small number of constant parameter values to all grid cells in a model, we developed procedures that predict a frequency distribution of values for any given grid cell. Thus, by incorporating the mean and variance model fidelity has been improved. The trait-based approach has improved land modeling by (1) incorporating patterns and heterogeneity of traits into model parameterization, thus evolving away from a framework that considers large areas of vegetation to have near identical trait values and (2) allowing for improved treatment of physiological responses to environmental drivers.

54 ENVIRONMENTAL SCIENCES↗

Global aspects of the motion of the heliospheric termination shock: A gasdynamic model

The heliospheric termination shock is expected to move in response to variation in upstream solar wind conditions. Using numerical techniques, we extend an earlier strictly one-dimensional analytic gas dynamic model of shock motion to two dimensions, to investigate the qualitative features of global behavior of shock motion, and the consequences of latitudinal variation in dynamic pressure. The boundary conditions of the calculation are given by the solar wind parameters as a function of latitude and time on an inner spherical boundary, and a constant pressure (roughly simulating the effect of the local interstellar medium) on an outer boundary. Density variations, specified at the inner boundary as a function of time, are convected into the termination shock. Immediately after the interaction, the shock moves with speeds given by the earlier analytic model. However, as the termination shock propagates outward (or inward), it begins to slow down. After about 2 to 10 years, depending on details of boundary conditions, the signal from the shock interaction has reached the outer boundary and propagates inward to the position of the termination shock, strongly affecting the behavior of the shock. Assuming no further disturbances in the solar wind, the termination shock will reach its new equilibrium after some tens of years. In reality, large-scale variations in solar wind dynamic pressure occur on time scales short in comparison with the eleven year solar cycle, so that one expects that the termination shock is never in an equilibrium position, but rather oscillates inward and outward; this oscillation will vary with heliographic latitude. The effects of a variety of types of solar wind disturbances are investigated and summarized.

Ratkiewicz, R.↗

Sensitivities of Modeled Tropical Cyclones to Surface Friction and the Coriolis Parameter

In this investigation the sensitivities of a 2-D tropical cyclone (TC) model to surface frictional coefficient and the Coriolis parameter are studied and their implication is discussed. The model used is an axisymmetric version of the latest version of the Goddard cloud ensemble model. The model has stretched vertical grids with 33 levels varying from 30 m near the bottom to 1140 m near the top. The vertical domain is about 21 km. The horizontal domain covers a radius of 962 km (770 grids) with a grid size of 1.25 km. The time step is 10 seconds. An open lateral boundary condition is used. The sea surface temperature is specified at 29C. Unless specified otherwise, the Coriolis parameter is set at its value at 15 deg N. The Newtonian cooling is used with a time scale of 12 hours. The reference vertical temperature profile used in the Newtonian cooling is that of Jordan. The Newtonian cooling models not only the effect of radiative processes but also the effect of processes with scale larger than that of TC. Our experiments showed that if the Newtonian cooling is replaced by a radiation package, the simulated TC is much weaker. The initial condition has a temperature uniform in the radial direction and its vertical profile is that of Jordan. The initial winds are a weak Rankin vortex in the tangential winds superimposed on a resting atmosphere. The initial sea level pressure is set at 1015 hPa everywhere. Since there is no surface pressure perturbation, the initial condition is not in gradient balance. This initial condition is enough to lead to cyclogenesis, but the initial stage (say, the first 24 hrs) is not considered to resemble anything observed. The control experiment reaches quasi-equilibration after about 10 days with an eye wall extending from 15 to 25 km radius, reasonable comparing with the observations. The maximum surface wind of more than 70 m/s is located at about 18 km radius. The minimum sea level pressure on day 10 is about 886 hPa. Thus the overall simulation is considered successful and the model is considered adequate for our investigation.

Chao, Winston C.↗

Density and pressure variability in the mesosphere and thermosphere

In an effort to isolate the essential physics of the mesosphere and the thermosphere, a steady one-dimensional density and pressure model has been developed in support of related NASA activities, i.e., projects such as the AOTV and the Space Station. The model incorporates a zeroth order basic state including both the three-dimensional wind field and its associated shear structure, etc. A first order wave field is also incorporated in period bands ranging from about one second to one day. Both basic state and perturbation quantities satsify the combined constraints of mass, linear momentum and energy conservation on the midlatitude beta plane. A numerical (iterative) technique is used to solve for the vertical wind which is coupled to the density and pressure fields. The temperature structure from 1 to 1000 km and the lower boundary conditions are specified using the U.S. Standard Atmosphere 1976. Vertical winds are initialized at the top of the Planetary Boundary Layer using Ekman pumping values over flat terrain. The model also allows for the generation of waves during the geostrophic adjustment process and incorporates wave nonlinearity effects.

Davis, T. M.↗

Code Benchmark of the HTTF Pressurized Conduction Cooldown Test Using SAM

The High Temperature Test Facility (HTTF) at Oregon State University is an integral system test facility to simulate postulated reactor transients of prismatic high-temperature gas-cooled reactors(HTGRs). A series of test campaigns was launched, providing abundant test data that could be used to benchmark reactor system analysis codes like the System Analysis Module (SAM). In this study, a SAM model of the facility is developed based on the two-dimensional (2D) ring model approach. All components including the ceramic matrix, graphite heaters, helium coolant channels, core barrel, upcomer, pressure vessel, and reactor cavity cooling system are modeled as concentric cylindrical rings. The model is used to simulate one of the benchmark problems-Pressurized Conduction Cooldown (PCC)-within the scope of the Organisation for Economic Co-operation and Development Nuclear Energy Agency International HTTF Benchmark. The simulations consist of two parts. In the first part, operating and boundary conditions as well as thermophysical properties of materials are specified for the benchmark problem. In this work, results from the first part will be used in code-to-code comparison. In the second part, the SAM model is used to simulate Test PG-27, which is the first PCC test carried out in the HTTF, with only two of the ten heater banks activated. The results in the second part are used for code-to-data comparison. Because the helium coolant flow rate is not measured in this facility, it is estimated using the input power and inlet/outlet coolant temperatures. Additionally, radial heat flow in the ceramic blocks is complicated by hundreds of cylindrical coolant channels and heater rods embedded in them. As such, it is necessary to deduce an effective thermal conductivity for the ceramic to analyze the core thermal behavior. SAM predictions of the helium coolant and ceramic temperatures are compared with test data measured in three equivalent sectors. Overall, the SAM results agree reasonably well with test data within the variation of data among the three sectors, which demonstrates SAM's capability in capturing transient effects in HTGR using the simplified 2D ring model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CFD studies on burner secondary airflow

In many fossil power plants operating today, there is insufficient means to assure the proper balancing of the secondary airflows between the individual burners of wall-fired units. This mismatch leads to decreased boiler efficiency and increased emissions. In this study, a computational fluid dynamics (CFD) modeling of a fossil power plant wind box was performed. The model solved the three-dimensional Reynolds averaged Navier-Stokes equations with the k-epsilon turbulence model. The CFD results were validated by the experimental data taken from a 1/8th scale model of a wall-fired fossil unit. Simulations under various mass flow rates specified at inlet, various baffle positions and two opening conditions of the burners were obtained to identify the optimum design in terms of the equalization of the secondary airflow through the burners. This study demonstrated that the combination of experimental and CFD approach can be an effective tool in the research of burner secondary airflow balancing.

20 FOSSIL-FUELED POWER PLANTS↗

Spherical and sessile droplet dynamics by fluctuating hydrodynamics

We simulate the mesoscopic dynamics of droplets formed by phase-separated fluids at nanometer scales where thermal fluctuations are significant. Both spherical droplets fully immersed in a second fluid and sessile droplets which are also in contact with a solid surface are studied. Our model combines a Cahn–Hilliard formulation with incompressible fluctuating hydrodynamics; for sessile droplets, the fluid–solid contact angle is specified as a boundary condition. Deterministic simulations with an applied body force are used to measure the droplets' mobility from which a diffusion coefficient is obtained using the Einstein relation. Stochastic simulations are independently used to obtain a diffusion coefficient from a linear fit of the variance of a droplet's position with time. In some scenarios, these two measurements give the same value but not in the case of a spherical droplet initialized near a slip wall or in the case of sessile droplets with large contact angles (≥90°) on both slip and no-slip surfaces.

Bell, John B↗

Is the acceleration of anomalous cosmic rays affected by the geometry of the termination shock?

Historically, anomalous cosmic rays (ACRs) were thought to be accelerated at the solar-wind termination shock (TS) by the diffusive shock acceleration process. When Voyager 1 crossed the TS in 2004, the measured ACR spectra did not match the theoretical prediction of a continuous power law, and the source of the high-energy ACRs was not observed. When the Voyager 2 crossed the TS in 2007, it produced similar results. Several possible explanations have since appeared in the literature, but we follow the suggestion that ACRs are still accelerated at the shock, only away from the Voyager crossing points. To investigate this hypothesis closer, we study ACR acceleration using a three-dimensional, non-spherical model of the heliosphere that is axisymmetric with respect to the interstellar flow direction. We then compare the results with those obtained for a spherical TS. A semi-analytic model of the plasma and magnetic field backgrounds is developed to permit an investigation over a wide range of parameters under controlled conditions. The model is applied to helium ACRs, whose phase-space trajectories are stochastically integrated backward in time until a pre-specified, low-energy boundary, taken to be 0.5 MeV n{sup –1} (the so-called injection energy), is reached. Our results show that ACR acceleration is quite efficient on the heliotail-facing part of the TS. For small values of the perpendicular diffusion coefficient, our model yields a positive intensity gradient between the TS and about midway through the heliosheath, in agreement with the Voyager observations.

79 ASTRONOMY AND ASTROPHYSICS↗

The influence of the equatorial QBO on sudden stratospheric warmings

A global primitive-equation model of the stratosphere and mesosphere is integrated for specified planetary-wave forcing at the 100-mb level with mean zonal flow conditions corresponding to the westerly and easterly phases of the equatorial QBO, respectively. The responses in the two QBO phases were compared for integrations with wavenumber-1 forcing-amplitude maxima at 100 mb and 60 deg N varying from 100 to 400 m. The phase of the QBO had little effect on the results in the weak-wave (100-m) cases, which did not produce warmings, and strong-wave (400-m) cases, which produced major sudden warmings.

Holton, James R.↗

Supersonic solutions of the solar-wind equations

We re-examine the inviscid solar-wind equations with heat conduction from below, and establish a fundamentally new approach for finding stellar solutions. Although the problem is fourth order, only two independent integration constants can be assigned, since two boundary conditions that are required to specify well-behaved supersonic solutions determine the values of the other two constants. The solar-wind-model of Noble and Scarf are essentially accurate for practical purposes, but in a fundamental sense they are not self-consistent. At the supersonic level, the ratio of thermal energy to gravitational potential, (kTr/GMm)(sub s), must lie in a narrow range, between 0.4375 and about 0.40, to permit well-behaved solutions for ionized hydrogen. For a supersonic solution this ratio uniquely determines the constants A and epsilon, which in turn govern not only the escape flux and the energy flux per particle but also T'(lambda approaches 0), the temperature gradient at infinity. It is very difficult to find solutions by trial and error, without employing T'(0) as a guide to the iteration of A and epsilon, because not only must (kTr/GMm)(sub s) be chosen within the acceptable range but then either A or epsilon must be guessed with phenomenal accuracy. Otherwise the numerical integration of temperature and expansion velocity do not yield acceptable values at infinity.

Chamberlain, Joseph W.↗

Hypersonic Flows About a 25 degree Sharp Cone

This paper presents the results of a numerical study that examines the surface heating discrepancies observed between computed and measured values along a sharp cone. With Mach numbers of an order of 10 and the freestream length Reynolds number of an order of 10 000, the present computations have been made with the direct simulation Monte Carlo (DSMC) method by using the G2 code of Bird. The flow conditions are those specified for two experiments conducted in the Veridian 48-inch Hypersonic Shock Tunnel. Axisymmetric simulations are made since the test model was assumed to be at zero incidence. Details of the current calculations are presented, along with comparisons between the experimental data, for surface heating and pressure distributions. Results of the comparisons show major differences in measured and calculated results for heating distributions, with differences in excess of 25 percent for the two cases examined.

Moss, James N.↗

Radioisotope Stirling Engine Powered Airship for Low Altitude Operation on Venus

The feasibility of a Stirling engine powered airship for the near surface exploration of Venus was evaluated. The heat source for the Stirling engine was limited to 10 general purpose heat source (GPHS) blocks. The baseline airship utilized hydrogen as the lifting gas and the electronics and payload were enclosed in a cooled insulated pressure vessel to maintain the internal temperature at 320 K and 1 Bar pressure. The propulsion system consisted of an electric motor driving a propeller. An analysis was set up to size the airship that could operate near the Venus surface based on the available thermal power. The atmospheric conditions on Venus were modeled and used in the analysis. The analysis was an iterative process between sizing the airship to carry a specified payload and the power required to operate the electronics, payload and cooling system as well as provide power to the propulsion system to overcome the drag on the airship. A baseline configuration was determined that could meet the power requirements and operate near the Venus surface. From this baseline design additional trades were made to see how other factors affected the design such as the internal temperature of the payload chamber and the flight altitude. In addition other lifting methods were evaluated such as an evacuated chamber, heated atmospheric gas and augmented heated lifting gas. However none of these methods proved viable.

Colozza, Anthony J.↗

Radioisotope Stirling Engine Powered Airship for Atmospheric and Surface Exploration of Titan

The feasibility of an advanced Stirling radioisotope generator (ASRG) powered airship for the near surface exploration of Titan was evaluated. The analysis did not consider the complete mission only the operation of the airship within the atmosphere of Titan. The baseline airship utilized two ASRG systems with a total of four general-purpose heat source (GPHS) blocks. Hydrogen gas was used to provide lift. The ASRG systems, airship electronics and controls and the science payload were contained in a payload enclosure. This enclosure was separated into two sections, one for the ASRG systems and the other for the electronics and payload. Each section operated at atmospheric pressure but at different temperatures. The propulsion system consisted of an electric motor driving a propeller. An analysis was set up to size the airship that could operate near the surface of Titan based on the available power from the ASRGs. The atmospheric conditions on Titan were modeled and used in the analysis. The analysis was an iterative process between sizing the airship to carry a specified payload and the power required to operate the electronics, payload and cooling system as well as provide power to the propulsion system to overcome the drag on the airship. A baseline configuration was determined that could meet the power requirements and operate near the Titan surface. From this baseline design additional trades were made to see how other factors affected the design such as the flight altitude and payload mass and volume.

Titan↗

ComStock Measure Documentation: Ideal Thermal Air Loads

This study provides hypothetical thermal heating and cooling loads for ComStock models representing the U.S. commercial building stock. This measure scenario removes all HVAC models from the baseline ComStock building model and instead uses "ideal air" to meet loads. "Ideal air" can be thought of as an HVAC unit that mixes air at the zone exhaust condition with the specified amount of outdoor air, and then adds or removes heat and moisture at 100% efficiency to produce a supply air stream at the specified conditions. The resulting ideal thermal loads are represented under the "district" fuel type for both heating and cooling and can be found in both annual and timeseries results in the ComStock public dataset. This measure scenario does not represent any real technology or improvement, but rather, serves as a resource for thermal heating and cooling loads for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗