Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Biologically Effective Dose (BED) Correlation With Biochemical Control After Low-Dose Rate Prostate Brachytherapy for Clinically Low-Risk Prostate Cancer

Purpose: To assess the correlation of postimplant dosimetric quantifiers with biochemical control of prostate cancer after low-dose rate brachytherapy. Methods and Materials: The biologically effective dose (BED), dose in Gray (Gy) to 90% of prostate (D{sub 90}), and percent volume of the prostate receiving 100% of the prescription dose (V{sub 100}) were calculated from the postimplant dose-volume histogram for 140 patients undergoing low-dose rate prostate brachytherapy from 1997 to 2003 at Durham Regional Hospital and the Durham VA Medical Center (Durham, NC). Results: The median follow-up was 50 months. There was a 7% biochemical failure rate (10 of 140), and 91% of patients (127 of 140) were alive at last clinical follow-up. The median BED was 148 Gy (range, 46-218 Gy). The median D{sub 90} was 139 Gy (range, 45-203 Gy). The median V{sub 100} was 85% (range, 44-100%). The overall 5-year biochemical relapse-free survival (bRFS) rate was 90.1%. On univariate Cox proportional hazards modeling, no pretreatment characteristic (Gleason score sum, age, baseline prostate-specific antigen, or clinical stage) was predictive of bRFS. The BED, D{sub 90}, and V{sub 100} were all highly correlated (Pearson coefficients >92%), and all were strongly correlated with bRFS. Using the Youden method, we identified the following cut points for predicting freedom from biochemical failure: D{sub 90} >= 110 Gy, V{sub 100} >= 74%, and BED >= 115 Gy. None of the covariates significantly predicted overall survival. Conclusions: We observed significant correlation between BED, D{sub 90}, and V{sub 100} with bRFS. The BED is at least as predictive of bRFS as D{sub 90} or V{sub 100}. Dosimetric quantifiers that account for heterogeneity in tumor location and dose distribution, tumor repopulation, and survival probability of tumor clonogens should be investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-213-02: Characterizing 3D Printing in the Fabrication of Variable Density Phantoms

Purpose: In this work, we present characterization, process flow, quality control and application of 3D fabricated low density phantoms for radiotherapy quality assurance. Methods: A Rostock delta 3D printer using polystyrene filament of diameter 1.75 mm was used to print geometric volumes of 2×2×1 cm{sup 3} of varying densities. The variable densities of 0.1 to 0.75 g/cm {sup 3} were created by modulating the infill. A computed tomography (CT) scan was performed to establish an infill-density calibration curve as well as characterize the quality of the print such as uniformity and the infill pattern. The time required to print these volumes was also recorded. Using the calibration, two low density cones (0.19, 0.52 g/cm{sup 3}) were printed and benchmarked against commercially available phantoms. The dosimetric validation of the low density scaling of Anisotropic Analytical Algorithm (AAA) was performed by using a 0.5 g/cm{sup 3} slab of 10×10×2.4 cm{sup 3} with EBT3 GafChromic film. The gamma analysis at 3%/3mm criteria were compared for the measured and computed dose planes. Results: Analysis of the volume of air pockets in the infill resulted in a reasonable uniformity for densities 0.4 to 0.75 g/cm{sup 3}. Printed phantoms with densities below 0.4 g/cm{sup 3} exhibited a higher ratio of air to polystyrene resulting in large non-uniformity. Compared to the commercial inserts, good agreement was observed only for the printed 0.52 g/cm{sup 3} cone. Dosimetric comparison for a printed low density volume placed in-between layers of solid water resulted in >95% gamma agreement between AAA calculated dose planes and measured EBT3 films for a 6MV 5×5 cm{sup 2} clinical beam. The comparison showed disagreement in the penumbra region. Conclusion: In conclusion, 3D printing technology opens the door to desktop fabrication of variable density phantoms at economical prices in an efficient manner for the quality assurance needs of a small clinic.

60 APPLIED LIFE SCIENCES↗

Adaptive Radiotherapy for Locally Advanced Non-Small-Cell Lung Cancer Does Not Underdose the Microscopic Disease and has the Potential to Increase Tumor Control

Purpose: To evaluate doses to the microscopic disease (MD) in adaptive radiotherapy (ART) for locally advanced non-small-cell lung cancer (NSCLC) and to model tumor control probability (TCP). Methods and Materials: In a retrospective planning study, three-dimensional conformal treatment plans for 13 patients with locally advanced NSCLC were adapted to shape and volume changes of the gross tumor volume (GTV) once or twice during conventionally fractionated radiotherapy with total doses of 66 Gy; doses in the ART plans were escalated using an iso-mean lung dose (MLD) approach compared to non-adapted treatment. Dose distributions to the volumes of suspect MD were simulated for a scenario with synchronous shrinkage of the MD and GTV and for a scenario of a stationary MD despite GTV shrinkage; simulations were performed using deformable image registration. TCP calculations considering doses to the GTV and MD were performed using three different models. Results: Coverage of the MD at 50 Gy was not compromised by ART. Coverage at 60 Gy in the scenario of a stationary MD was significantly reduced from 92% {+-} 10% to 73% {+-} 19% using ART; however, the coverage was restored by iso-MLD dose escalation. Dose distributions in the MD were sufficient to achieve a TCP >80% on average in all simulation experiments, with the clonogenic cell density the major factor influencing TCP. The combined TCP for the GTV and MD was 19.9% averaged over all patients and TCP models in non-adaptive treatment with 66 Gy. Iso-MLD dose escalation achieved by ART increased the overall TCP by absolute 6% (adapting plan once) and by 8.7% (adapting plan twice) on average. Absolute TCP values were significantly different between the TCP models; however, all TCP models suggested very similar TCP increase by using ART. Conclusions: Adaptation of radiotherapy to the shrinking GTV did not compromise dose coverage of volumes of suspect microscopic disease and has the potential to increase TCP by >40% compared with radiotherapy planning without ART.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A sharp immersed method for 2D flow-body interactions using the vorticity-velocity Navier-Stokes equations

Immersed methods discretize boundary conditions for complex geometries on background Cartesian grids. Here, this makes such methods especially suitable for two-way coupled flow-body problems, where the body mechanics are partially driven by hydrodynamic forces. However, for the vorticity-velocity form of the Navier-Stokes equations, existing immersed geometry discretizations for two-way coupled problems only achieve first order spatial accuracy near solid boundaries. Here we introduce a sharp-interface approach based on the immersed interface method to handle the one- and two-way coupling between an incompressible flow and one or more rigid bodies using the 2D vorticity-velocity Navier-Stokes equations. Our main contributions are three-fold. First, we develop and analyze a moving boundary treatment for sharp immersed methods that can be applied to PDEs with implicitly defined boundary conditions, such as those commonly imposed on the vorticity field. Second, we develop a two-way coupling methodology for the vorticity-velocity Navier-Stokes equations based on control-volume momentum balance that does not require the pressure field. Third, we show through extensive testing and validation that our resulting flow-body solver reaches second-order accuracy for most practical scenarios, and provides significant efficiency benefits compared to a representative first-order approach.

42 ENGINEERING↗

Single Crystal Growth of Relaxor Ferroelectric Ba 2 PrFeNb 4 O 15 by the Optical Floating Zone Method

Uniaxial tungsten bronzes have received increasing interest because of their potential application as lead-free ferroelectrics as well as their flexibility-via chemical substitution. Here we demonstrate growth of single crystals of one such material, Ba 2 PrFeNb 4 O 15 , which possesses the tetragonal tungsten bronze structure, by the optical floating zone method. The challenge of this growth is to control the stability of the molten zone which allows the growth to persist for a long enough time to achieve large volume single crystals. Our work reveals that the use of a slight overpressure of air allows the molten zone to be maintained up to 7 h at a traveling speed of 4 mm/h. The obtained crystals were studied using high-resolution single crystal scattering, powder X-ray diffraction, and dielectric measurements. We find that Ba 2 PrFeNb 4 O 15 possesses a rather complex average structure with a monoclinic symmetry in a P 112/ m space group and unit cell parameters of a = 12.49188(8) Å, b = 12.49232(8) Å, c = 3.92863(1) Å, and γ = 90.056 °, with an additional incommensurate superstructural modulation superimposed. The temperature dependence of dielectric properties has been investigated by comparing as-grown, O 2 -annealed, and Ar-annealed samples. A broad relaxation dielectric peak is observed around 150 K for the O 2 -annealed sample, indicating a typical relaxor behavior below 150 K. A larger dielectric permittivity (ε' ≈ 1300) than those of corresponding ceramics (up to ε' ≈ 200) is found in the oxygen annealed crystals. In conclusion, we suggest that as-grown single crystals are oxygen deficient and that the oxygen vacancies can be eliminated by an oxygen annealing treatment.

36 MATERIALS SCIENCE↗

Reversible, Tunable, Electric-Field Driven Assembly of Silver Nanocrystal Superlattices

Nanocrystal superlattices are typically fabricated by either solvent evaporation or destabilization methods that require long time periods to generate highly ordered structures. In this paper, we report for the first time the use of electric fields to reversibly drive nanocrystal assembly into superlattices without changing solvent volume or composition, and show that this method only takes 20 min to produce polyhedral colloidal crystals, which would otherwise need days or weeks. This method offers a way to control the lattice constants and degree of preferential orientation for superlattices and can suppress the uniaxial superlattice contraction associated with solvent evaporation. As a result, in situ small-angle X-ray scattering experiments indicated that nanocrystal superlattices were formed while solvated, not during drying.

36 MATERIALS SCIENCE↗

Numerical investigations on hot-zone modified DS furnace for mc-Si growth process

A transient global numerical model has been carried out to simulate the multi-crystalline silicon growth process by the directional solidification method using CGSim 15.1. A two dimensional axisymmetric model was used. The conductive, convective, and radiative heat transfer problems were coupled with our model and these problems were solved iteratively using the finite volume method. In the present work we have modified the heater element to produce a high quality ingot from multi-crystalline silicon. The change has been made to control the temperature distribution. By controlling the temperature distribution, we can also control the melt crystal interface of the ingot. The shape of the melt-crystal interface of the ingot, the temperature distribution in the crucible and the heat flux from the melt as well as from the crystal have been studied. Finally, the simulation results show that the modification in the heater element keeps the melt-crystal interface as planar in the DS system, also it gives better results than conventional system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimizing principal component models for representing interfraction variation in lung cancer radiotherapy

Purpose: To optimize modeling of interfractional anatomical variation during active breath-hold radiotherapy in lung cancer using principal component analysis (PCA). Methods: In 12 patients analyzed, weekly CT sessions consisting of three repeat intrafraction scans were acquired with active breathing control at the end of normal inspiration. The gross tumor volume (GTV) and lungs were delineated and reviewed on the first week image by physicians and propagated to all other images using deformable image registration. PCA was used to model the target and lung variability during treatment. Four PCA models were generated for each specific patient: (1) Individual models for the GTV and each lung from one image per week (week to week, W2W); (2) a W2W composite model of all structures; (3) individual models using all images (weekly plus repeat intrafraction images, allscans); and (4) composite model with all images. Models were reconstructed retrospectively (using all available images acquired) and prospectively (using only data acquired up to a time point during treatment). Dominant modes representing at least 95% of the total variability were used to reconstruct the observed anatomy. Residual reconstruction error between the model-reconstructed and observed anatomy was calculated to compare the accuracy of the models. Results: An average of 3.4 and 4.9 modes was required for the allscans models, for the GTV and composite models, respectively. The W2W model required one less mode in 40% of the patients. For the retrospective composite W2W model, the average reconstruction error was 0.7{+-}0.2 mm, which increased to 1.1{+-}0.5 mm when the allscans model was used. Individual and composite models did not have significantly different errors (p=0.15, paired t-test). The average reconstruction error for the prospective models of the GTV stabilized after four measurements at 1.2{+-}0.5 mm and for the composite model after five measurements at 0.8{+-}0.4 mm. Conclusions: Retrospective PCA models were capable of reconstructing original GTV and lung shapes and positions within several millimeters with three to four dominant modes, on average. Prospective models achieved similar accuracy after four to five measurements.

60 APPLIED LIFE SCIENCES↗

Multiscale Patterning from Competing Interactions and Length Scales

We live in an era of complexity marked by impressive new tools powering the scientific method to accelerate discovery, prediction, and control of increasingly complex systems. In common with many disciplines and societal challenges and opportunities, materials and condensed matter sciences are beneficiaries. The volume and fidelity of experimental, computational, and visualization data available, and tools to rapidly interpret them, are remarkable. Conceptual frameworks, including multiscale, multiphysics modeling of this complexity, are fueled by the data and, in turn, guide directions for future experimental and computational strategies. In this spirit, we discuss the importance of competing interactions, length scales, and constraints as pervasive sources of spatio-temporal complexity. We use representative examples drawn from materials and condensed matter, including the important role of elasticity in some technologically important quantum materials.

36 MATERIALS SCIENCE↗

Volume Changes After Stereotactic LINAC Radiotherapy in Vestibular Schwannoma: Control Rate and Growth Patterns

Purpose: The purpose of this study was to evaluate the control rate of vestibular schwannomas (VS) after treatment with linear accelerator (LINAC)-based stereotactic radiosurgery (SRS) or radiotherapy (SRT) by using a validated volumetric measuring tool. Volume-based studies on prognosis after LINAC-based SRS or SRT for VS are reported scarcely. In addition, growth patterns and risk factors predicting treatment failure were analyzed. Materials and Methods: Retrospectively, 37 VS patients treated with LINAC based SRS or SRT were analyzed. Baseline and follow-up magnetic resonance imaging scans were analyzed with volume measurements on contrast enhanced T1-weighted magnetic resonance imaging. Absence of intervention after radiotherapy was defined as 'no additional intervention group, ' absence of radiological growth was defined as 'radiological control group. ' Significant growth was defined as a volume change of 19.7% or more, as calculated in a previous study. Results: The cumulative 4-year probability of no additional intervention was 96.4% {+-} 0.03; the 4-year radiological control probability was 85.4% {+-} 0.1). The median follow-up was 40 months. Overall, shrinkage was seen in 65%, stable VS in 22%, and growth in 13%. In 54% of all patients, transient swelling was observed. No prognostic factors were found regarding VS growth. Previous treatment and SRS were associated with transient swelling significantly. Conclusions: Good control rates are reported for LINAC based SRS or SRT in VS, in which the lower rate of radiological growth control is attributed to the use of the more sensitive volume measurements. Transient swelling after radiosurgery is a common phenomenon and should not be mistaken for treatment failure. Previous treatment and SRS were significantly associated with transient swelling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

IDAES-PSE 2.0 Release

The Institute for the Design of Advanced Energy Systems (IDAES) Integrated Platform is a versatile computational environment offering extensive process systems engineering (PSE) capabilities for optimizing the design and operation of complex, interacting technologies and systems. IDAES enables users to efficiently search vast, complex design spaces to discover the lowest cost, most environmentally sustainable solutions while supporting the full process modeling lifecycle, from conceptual design to dynamic optimization and control. The extensible, open platform empowers users to create models of novel processes and rapidly develop custom analyses, workflows, and end-user applications. IDAES-PSE 2.0.0 Release Highlights Removal of deprecated features from IDAES v1 Update to Pyomo v6.5 – this required a number of updates to support the new NL solver writer and to address some changes in Pyomo Creation of new testing suite for backward compatibility, model robustness and verification More general implementation of the Helmholtz EoS. This brings some new features like standard property diagrams, choice of mass or mole basis, and new state variable options Standardizing names in Heat Exchanger models (breaking change from v2.0.0a2): Control Volumes named hot_side and cold_side Ports names hot_side_inlet, hot_side_outlet, cold_side_inlet and cold_side_outlet Config Blocks names hot_side_config and cold_side_config Config arguments for user provided names for each side: hot_side_name and cold_side_name. Updating Keras surrogate tool to use v1.1 of OMLT New prototype API for model initialization (idaes.core.initialization) The new API uses "Model Initializer" objects instead of class methods, allowing for the definition of multiple initialization routines for a single model A number of common, model agnostic initialization routines have also been defined, including initialization from data, block-decomposition and a general hierarchical approach equivalent to the existing method for common unit models New metadata for thermophysical properties – valid_range This can be used to record the range of values over which a property value can be trusted, such as the range of experimental data used to regress parameters A number of new utility functions have been added to check for properties with values outside the valid range and to set bounds based on this metadata Updated construction of balance expressions in Control Volumes to remove unneeded terms In the past, unneeded terms were added as a constant 0 term, however they will now be dropped entirely from the expression This was necessary due to more strict unit checking in the new Pyomo solver writer which no longer ignores 0 terms Updates to metadata for thermophysical properties to better define known properties and units of measurement This results in more strict enforcement of standard naming for thermophysical and reaction properties Users can still define custom properties, but these must be done explicitly using the define_custom_properties() method instead of being implicitly created by add_property() Updated convergence tester utility tool to support definition of benchmark files (JSON format) and comparison of performance to benchmarks Set default iteration limit for IPOPT in IDAES config to 200 iterations Update scaling of example models to work with new Pyomo NL solver writer Improve testing of extensions and examples infrastructure to avoid need for downloading files Updated distillation column to centralize common functionality and remove a number of Pyomo warnings

IDAES↗

Gamma Knife Treatment of Growing Vestibular Schwannoma in Norway: A Prospective Study

Purpose: Gamma Knife radiosurgery (GKRS) has been increasingly used in the treatment of vestibular schwannoma (VS). Very few studies relate tumor control and post-treatment growth rates to pretreatment growth rates. Methods and Materials: We prospectively included 45 consecutive VS patients who were initially treated conservatively and then received GKRS between 2000 and 2007 because of demonstrated tumor growth. Pretreatment and post-treatment tumor volumes were estimated. Patients underwent audiograms, reported their symptoms, and responded to the Short Form General Health Survey (SF-36) questionnaire on each visit. Results: Volume doubling times before and after treatment were 1.36 years (95% confidence intervals, 1.14-1.68) and -13.1 years (95% confidence intervals, -111.0 to -6.94), respectively. Tumor control, defined as a post-GKRS growth rate {<=}0, was achieved in 71.1% of patients, with highest odds for tumor control among older patients and those with larger tumors. The 5-year retreatment-free survival rate was 93.9% (95% confidence intervals, 76.5-98.5). None of the clinical endpoints investigated showed statistically significant changes after GKRS, but improvement was seen in a few SF-36 parameters. Conclusions: GKRS alters the natural course of the tumor by reducing growth. Mathematic models yield poorer tumor control rates than those found by clinical assessment. Symptoms were unaffected by treatment, but quality of life was improved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric and Radiobiological Consequences of Computed Tomography–Guided Adaptive Strategies for Intensity Modulated Radiation Therapy of the Prostate

Purpose: To examine a range of scenarios for image-guided adaptive radiation therapy of prostate cancer, including different schedules for megavoltage CT imaging, patient repositioning, and dose replanning. Methods and Materials: We simulated multifraction dose distributions with deformable registration using 35 sets of megavoltage CT scans of 13 patients. We computed cumulative dose–volume histograms, from which tumor control probabilities and normal tissue complication probabilities (NTCPs) for rectum were calculated. Five-field intensity modulated radiation therapy (IMRT) with 18-MV x-rays was planned to achieve an isocentric dose of 76 Gy to the clinical target volume (CTV). The differences between D{sub 95}, tumor control probability, V{sub 70Gy}, and NTCP for rectum, for accumulated versus planned dose distributions, were compared for different target volume sizes, margins, and adaptive strategies. Results: The CTV D{sub 95} for IMRT treatment plans, averaged over 13 patients, was 75.2 Gy. Using the largest CTV margins (10/7 mm), the D{sub 95} values accumulated over 35 fractions were within 2% of the planned value, regardless of the adaptive strategy used. For tighter margins (5 mm), the average D{sub 95} values dropped to approximately 73.0 Gy even with frequent repositioning, and daily replanning was necessary to correct this deficit. When personalized margins were applied to an adaptive CTV derived from the first 6 treatment fractions using the STAPLE (Simultaneous Truth and Performance Level Estimation) algorithm, target coverage could be maintained using a single replan 1 week into therapy. For all approaches, normal tissue parameters (rectum V{sub 70Gy} and NTCP) remained within acceptable limits. Conclusions: The frequency of adaptive interventions depends on the size of the CTV combined with target margins used during IMRT optimization. The application of adaptive target margins (<5 mm) to an adaptive CTV determined 1 week into therapy minimizes the need for subsequent dose replanning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiobiological Determination of Dose Escalation and Normal Tissue Toxicity in Definitive Chemoradiation Therapy for Esophageal Cancer

Purpose: This study investigated the trade-off in tumor coverage and organ-at-risk sparing when applying dose escalation for concurrent chemoradiation therapy (CRT) of mid-esophageal cancer, using radiobiological modeling to estimate local control and normal tissue toxicity. Methods and Materials: Twenty-one patients with mid-esophageal cancer were selected from the SCOPE1 database (International Standard Randomised Controlled Trials number 47718479), with a mean planning target volume (PTV) of 327 cm{sup 3}. A boost volume, PTV2 (GTV + 0.5 cm margin), was created. Radiobiological modeling of tumor control probability (TCP) estimated the dose required for a clinically significant (+20%) increase in local control as 62.5 Gy/25 fractions. A RapidArc (RA) plan with a simultaneously integrated boost (SIB) to PTV2 (RA{sub 62.5}) was compared to a standard dose plan of 50 Gy/25 fractions (RA{sub 50}). Dose-volume metrics and estimates of normal tissue complication probability (NTCP) for heart and lungs were compared. Results: Clinically acceptable dose escalation was feasible for 16 of 21 patients, with significant gains (>18%) in tumor control from 38.2% (RA{sub 50}) to 56.3% (RA{sub 62.5}), and only a small increase in predicted toxicity: median heart NTCP 4.4% (RA{sub 50}) versus 5.6% (RA{sub 62.5}) P<.001 and median lung NTCP 6.5% (RA{sub 50}) versus 7.5% (RA{sub 62.5}) P<.001. Conclusions: Dose escalation to the GTV to improve local control is possible when overlap between PTV and organ-at-risk (<8% heart volume and <2.5% lung volume overlap for this study) generates only negligible increase in lung or heart toxicity. These predictions from radiobiological modeling should be tested in future clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of High-Risk Computed Tomography Features for Detection of Local Recurrence After Stereotactic Body Radiation Therapy for Early-Stage Non-Small Cell Lung Cancer

Purpose: Fibrotic changes after stereotactic body radiation therapy (SBRT) for stage I non-small cell lung cancer (NSCLC) are difficult to distinguish from local recurrences (LR), hampering proper patient selection for salvage therapy. This study validates previously reported high-risk computed tomography (CT) features (HRFs) for detection of LR in an independent patient cohort. Methods and Materials: From a multicenter database, 13 patients with biopsy-proven LR were matched 1:2 to 26 non-LR control patients based on dose, planning target volume (PTV), follow-up time, and lung lobe. Tested HRFs were enlarging opacity, sequential enlarging opacity, enlarging opacity after 12 months, bulging margin, linear margin disappearance, loss of air bronchogram, and craniocaudal growth. Additionally, 2 new features were analyzed: the occurrence of new unilateral pleural effusion, and growth based on relative volume, assessed by manual delineation. Results: All HRFs were significantly associated with LR except for loss of air bronchogram. The best performing HRFs were bulging margin, linear margin disappearance, and craniocaudal growth. Receiver operating characteristic analysis of the number of HRFs to detect LR had an area under the curve (AUC) of 0.97 (95% confidence interval [CI] 0.9-1.0), which was identical to the performance described in the original report. The best compromise (closest to 100% sensitivity and specificity) was found at ≥4 HRFs, with a sensitivity of 92% and a specificity of 85%. A model consisting of only 2 HRFs, bulging margin and craniocaudal growth, resulted in a sensitivity of 85% and a specificity of 100%, with an AUC of 0.96 (95% CI 0.9-1.0) (HRFs ≥2). Pleural effusion and relative growth did not significantly improve the model. Conclusion: We successfully validated CT-based HRFs for detection of LR after SBRT for early-stage NSCLC. As an alternative to number of HRFs, we propose a simplified model with the combination of the 2 best HRFs: bulging margin and craniocaudal growth, although validation is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced joining strength in additive-manufactured polylactic-acid structures fused by embedded heated metallic meshes

Additively manufactured thermoplastic polymers, such as polylactic acid (PLA), hold significant promise for sustainable engineering structures, including wind turbine blades. Upscaling these structures beyond the limitations of 3D printer build volumes is a challenge; fusion joining presents a potential solution. This paper introduces a displacement-controlled resistance welding process for PLA, as an alternative to the typical force-controlled methods. Here, we investigated the bonding quality of resistance-welded and adhesive-bonded PLA beams through three-point bending and measured the surface deformations using digital image correlation. Different metal meshes (30%/0.11 mm Ni—Cu, 34%/0.07 mm Ni—Cu, and 36%/0.25 mm Co—Ni) served as heating elements. The process parameters were varied for the 34%/0.07 mm Ni—Cu mesh to identify an optimum set of parameters. Results showed that this optimized displacement-controlled welding achieved 94% of the original strength of monolithic samples. This indicates that the new welding process not only ensures high-quality bonding and fine surface finishing but also promotes sustainability, recyclability, and economic efficiency in various polymer and composite structural applications.

Additive manufacturing↗

A kernel machine method for detecting higher order interactions in multimodal datasets: Application to schizophrenia

Technological advances are enabling us to collect multimodal datasets at an increasing depth and resolution while with decreasing labors. Understanding complex interactions among multimodal datasets, however, is challenging. Here in this study, we tested the interaction effect of multimodal datasets using a novel method called the kernel machine for detecting higher order interactions among biologically relevant multimodal data. Using a semiparametric method on a reproducing kernel Hilbert space, we formulated the proposed method as a standard mixed-effects linear model and derived a score-based variance component statistic to test higher order interactions between multimodal datasets. The method was evaluated using extensive numerical simulation and real data from the Mind Clinical Imaging Consortium with both schizophrenia patients and healthy controls. Our method identified 13-triplets that included 6 gene-derived SNPs, 10 ROIs, and 6 gene-specific DNA methylations that are correlated with the changes in hippocampal volume, suggesting that these triplets may be important for explaining schizophrenia-related neurodegeneration. The performance of the proposed method is compared with the following methods: test based on only first and first few principal components followed by multiple regression, and full principal component analysis regression, and the sequence kernel association test. With strong evidence (p-value ≤0.000001), the triplet (MAGI2, CRBLCrus1.L, FBXO28) is a significant biomarker for schizophrenia patients. This novel method can be applicable to the study of other disease processes, where multimodal data analysis is a common task.

59 BASIC BIOLOGICAL SCIENCES↗

Dual-wavelength generation of picosecond pulses with 9.8 GHz repetition rate in Nd : YAG waveguide laser with graphene

We report a new solid-state waveguide laser generating picosecond pulses with a GHz repetition rate, based on the use of graphene as a saturable absorber. Lasing at the main transverse mode is provided by the geometry of a cylindrical waveguide formed in the active crystal volume by the method of direct writing with a femtosecond laser beam. Fine tuning of the intracavity interferometer formed between the active medium and output mirror makes it possible to control the spectral-temporal parameters of output radiation and to smoothly tune the repetition rate of pulses having a duration of less than 20 ps. In particular, the possibility of dual-wavelength generation in the regime of continuous passive mode locking using a single saturable absorber based on graphene is demonstrated. By amplifying laser output radiation in the ytterbium fibre amplifier, an average output power of 530 mW is obtained. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗