Search NASA⌕ Search

SEARCH · Search NASA

Results for “controller area network”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Structural Analysis and Electrochemical Properties of Bimetallic Palladium-Platinum Aerogels Prepared by a Two-Step Gelation Process

Multimetallic aerogels have emerged as promising unsupported and high-surface-area metal materials for different applications in heterogeneous catalysis and electrochemistry, which are fabricated using a gelation process characterized by the controlled aggregation of metallic nanoparticles to form a macroscopic network structure in aqueous solution. However, the achievement of the structural homogeneity of the multimetallic aerogels in terms of the diameter of the nanochains and the chemical composition at the nano- and the macro-scale is still a great challenge. In this paper, we investigated two Pd-Pt aerogels prepared by the two-step gelation method. The structural homogeneity and chemical distribution of both metals inside the aerogels were analyzed by using high-resolution (scanning) transmission microscopy, energy-dispersive X-ray spectroscopy, extended X-ray absorption fine structure spectroscopy and cyclic voltammetry. The Pd-Pt aerogels show the presence of Pd/Pt-rich domains inside the long-range framework. It is evident that the initial monometallic features dominate over alloying during the gelation process. Although the same synthetic approach for Pd-Pt aerogels with different atomic ratios was used, we observed that the sizes of these monometallic domains varied strongly between the Pd-rich and Pt-rich aerogels. The presence of such metal clusters influenced the electrochemical robustness of the Pd-Pt aerogels dramatically. Further, electrochemical durability investigations revealed that the aerogels with a high content of Pd are less stable because of the gradual dissolution of the less noble metal particularly inside the Pd-rich domains. A chemical and structural homogeneity might improve the lifetime of the Pd-Pt aerogels under electrochemical conditions. In this work, we provide a better understanding of the structure and chemical distribution of the bimetallic aerogel framework prepared by the two-step gelation process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Envisioning the Future Renewable and Resilient Energy Grids—A Power Grid Revolution Enabled by Renewables, Energy Storage, and Energy Electronics

Today’s power grids are facing tremendous challenges because of the ever-increasing power demand, system complexity, infrastructure cost, knowledge base, and policy and regulatory issues to achieve supply–demand power balance and resiliency with respect to more frequent extreme weather events and cyberattacks. It is particularly challenging when the transition toward 100% intermittent renewable energy sources is considered. Many countries are calling for building up more transmission and distribution lines to increase power delivery capacities. This article is an attempt to answer two urgent questions: Is more transmission and distribution infrastructure really needed to meet the increasing power demand? What kind of future grid infrastructure should we envision and build? This article attempts to answer these questions and proposes the concept of community-centric asynchronous renewable and resilient energy grids. By clearly differentiating the concepts of grid resilience and reliability, the importance of building resilient power electronics’ devices and robust system-level control algorithms to achieve 100% renewable energy integrated resilient grids is presented. To identify the shortcomings and propose advancements, power electronics’ technologies are categorized using the proposed concepts of natural source frequencies (NSf), energy storage, direct energy conversion/control and fault protection (DeCaFp), and high-efficiency energy consumption and buffering (heECaB) technology. The ability of networked microgrids to greatly reduce power outages and power system restoration time is demonstrated by leveraging robust decentralized and centralized control algorithms, identified through a comprehensive literature review. Future research areas are proposed to further enhance grid stability, controllability, cybersecurity, and protection against faults in the presence of 100% renewable sources by leveraging the advanced capabilities of NSf, DeCaFp, and heECaB devices and system-level control algorithms.

14 SOLAR ENERGY↗

Review of the impacts of leaking CO 2 gas and brine on groundwater quality

This review paper provides a synthetic view of the existing knowledge and summarizes data and findings of the recent literature on the subject of the potential leaking of CO2 from the deep subsurface storage reservoirs and the effects on aquifer quality. New ideas and concepts are developed and insights are also provided. The objectives of this paper are to: 1) present and discuss potential risks for groundwater degradation due to CO2 gas and brine exposure; 2) identify the set of geochemical data required to assess and predict aquifer responses to CO2 and brine leakage. Specifically, this paper will discuss the following issues: 1) Aquifer responses (such as changes in aqueous phase/groundwater chemical composition; changes in solid phase chemistry and mineralogy; changes in the extent and rate of reactions and processes and possible establishment of a new network of reactions and processes affecting or controlling overall mobility of major, minor, and trace elements; development of conceptual and reduced order models (ROMs) to describe and predict aquifer responses); 2) The degree of impact such as significant or insignificant changes in pH and major, minor, and trace element release that depend on the following controlling variables; the effect of leaking plume characteristics (gas composition, pure CO2 and/or CO2 -CH4 -H2S mixtures and brine concentration and composition (trace metals); aquifer properties [such as initial aqueous phase conditions and mineralogy: minerals controlling sediments’ response (e.g., calcite, Si bearing minerals, etc.)]; overview of relevant hydrogeological and geochemical processes related to the impact of CO2 gas and brine on groundwater quality; the fate of the elements released from sediments or transported with brine (such as precipitation/incorporation into minerals (calcite and other minerals), adsorption, electron transfer reactions, the role of natural attenuation; whether or not the release of metals following exposure to CO2 harmful (risk assessment).

Qafoku, Nikolla P.↗

WAMS-Based HVDC Damping Control for Cyber Attack Defense

Owing to the fast and large power regulating the capacity of the HVDC system, the wide-area measurement system (WAMS) based high voltage direct current (HVDC) system has been regarded as a prospective solution to deal with the low-frequency oscillation issue. However, due to the vulnerability of the WAMS communication, WAMS based HVDC system control can be a prime target of malicious penetrations that could lead to disastrous events. To remediate this adverse effect, an improved WAMS based HVDC damping control framework is proposed in this paper. First, a lightweight network named Attack Shuffle convolutional neural Networks (ASNet) is proposed to learn the characteristics of cyber attacks. Then, a model-free-based cyber attack defense framework is introduced to quickly identify the attack types based on the continuous wavelet transform and ASNet. Additionally, an improved control framework of the WAMS and HVDC-based wide-area power oscillation damping control (WH-PODC) is developed to provide different response control for mitigation of the impact of cyber attacks. Finally, the performance of the proposed WH-PODC control framework is evaluated with real PMU data in multiple scenarios in RTDS, where the results indicate that the response intensity can be kept under multiple types of cyber attacks while providing similar effectiveness in oscillation suppression to conventional controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of the Pacific DC Intertie Wide Area Damping Controller

This study describes the design and implementation of a proof-of-concept Pacific DC Intertie (PDCI) wide area damping controller and includes system test results on the North American Western Interconnection (WI). To damp inter-area oscillations, the controller modulates the power transfer of the PDCI, a ±500 kV DCtransmission line in the WI. The control system utilizes real-time phasor measurement unit feedback to construct a commanded power signal which is added to the scheduled power flow for the PDCI. After years of design, simulations, and development, this controller has been implemented in hardware and successfully tested in both open and closed-loop operation. The most important design specifications were safe, reliable performance, no degradation of any system modes in any circumstances, and improve damping to the controllable modes in the WI. The main finding is that the controller adds significant damping to the modes of the WI and does not adversely affect the system response in any of the test cases. The primary contribution of this paper, to the state of the art research, is the design methods and test results of the first North American real-time control system that uses wide area PMU feedback.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Renewable Resource Integration Project - Scoping Study of Strategic Transmission, Operations, and Reliability Issues

California is on a path to increase utilization of renewable resources. California will need to integrate approximately 30,000 megawatts (MW) of new renewable generation in the next 20 years. Renewable resources are typically located in remote locations, not near the load centers. Nearly two/thirds or 20,000 MW of new renewable resources needed are likely to be delivered to Los Angeles Basin transmission gateways. Integration of renewable resources requires interconnection to the power grid, expansion of the transmission system capability between the backbone power grid and transmission gateways, and increase in delivery capacity from transmission gateways to the local load centers. To scope the transmission, operations, and reliability issues for renewables integration, this research focused on the Los Angeles Basin Area transmission gateways where most of new renewables are likely. Necessary actions for successful renewables integration include: (1) Expand Los Angeles Basin Area transmission gateway and nomogram limits by 10,000 to 20,000 MW; (2) Upgrade local transmission network for deliverability to load centers; (3) Secure additional storage, demand management, automatic load control, dynamic pricing, and other resources that meet regulation and ramping needed in real time operations; (4) Enhance local voltage support; and (5) Expand deliverability from Los Angeles to San Diego and Northern California.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Closure Report Central Nevada Test Area Subsurface Corrective Action Unit 443 January 2016

The U.S. Department of Energy (DOE) Office of Legacy Management (LM) prepared this Closure Report for the subsurface Corrective Action Unit (CAU) 443 at the Central Nevada Test Area (CNTA), Nevada, Site. CNTA was the site of a 0.2- to 1-megaton underground nuclear test in 1968. Responsibility for the site’s environmental restoration was transferred from the DOE, National Nuclear Security Administration, Nevada Field Office to LM on October 1, 2006. The environmental restoration process and corrective action strategy for CAU 443 are conducted in accordance with the Federal Facility Agreement and Consent Order (FFACO 1996, as amended 2011) and all applicable Nevada Division of Environmental Protection (NDEP) policies and regulations. This Closure Report provides justification for closure of CAU 443 and provides a summary of completed closure activities; describes the selected corrective action alternative; provides an implementation plan for long-term monitoring with well network maintenance and approaches/policies for institutional controls (ICs); and presents the contaminant, compliance, and use-restriction boundaries for the site.

54 ENVIRONMENTAL SCIENCES↗

Trans-oceanic Remote Power Hardware-in-the-Loop: Multi-site Hardware, Integrated Controller, and Electric Network Co-simulation

Electric system operators are increasingly concerned with the potential system-wide impacts of the large-scale integration of distributed energy resources (DERs) including voltage control, protection coordination, and equipment wear. This prompts a need for new simulation techniques that can simultaneously capture all the components of these large integrated smart grid systems. This paper describes a novel platform that combines three emerging research areas: power systems co-simulation, power hardware in the loop (PHIL) simulation, and lab-lab links. The platform is distributed, real-time capable, allows for easy internet-based connection from geographically-dispersed participants, and is software platform agnostic. We demonstrate its utility by studying real-time PHIL co-simulation of coordinated solar PV firming control of two inverters connected in multiple electric distribution network models, prototypical of U.S. and Australian systems. Here, the novel trans-pacific closed-loop system simulation was conducted in real-time using a power network simulator and physical PV/battery inverter at power at the National Renewable Energy Laboratory in Golden, CO, USA and a physical PV inverter at power at the Commonwealth Scientific and Industrial Research Organisation's Energy Centre in Newcastle, NSW, Australia. This capability enables smart grid researchers throughout the world to leverage their unique simulation capabilities for multi-site collaborations that can effectively simulate and validate emerging smart grid technology solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On Concavity and Utilization Analytics of Wide-Area Network Transport Protocols

Wide-area data transfers in high-performance computing infrastructures and big data applications are increasingly carried over dynamically provisioned dedicated network connections, which provide high capacities with no competing traffic. Throughput of TCP and UDT over wide-area connections depends, often in a complex non-linear way, on the congestion control mechanism, buffer sizes, and the number of parallel streams. In addition, our extensive TCP and UDT throughput measurements and time traces over a suite of physical and emulated 10 Gbps connections with 0-366 ms round-trip times (RTTs) show significant statistical and temporal variations. Consequently, parameter selection and optimization for transport methods require data analytics to complement analytical throughput models. We present analytics based on the concavity-convexity of throughput profiles which provide insights into peak throughput and superior/inferior trend compared to linear interpolations based on RTT. In particular, we propose the utilization-concavity coefficient, a scalar metric that incorporates both utilization and concavity profile to characterize the overall performance of a transport protocol. These measurements-based anaytics enable us to select a transport protocol and its parameters for a given host and connection configuration to achieve high throughput with statistical guarantees.

Rao, Nageswara↗

Evaluation Report on "The Department's Unclassified Cyber Security Program"

Industry experts report that security challenges and threats are continually evolving as malicious activity has become more web-based and attackers are able to rapidly adapt their attack methods. In addition, the number of data breaches continues to rise. In an effort to mitigate and address threats and protect valuable information, the Department of Energy anticipated spending about $275 million in Fiscal Year (FY) 2009 to implement cyber security measures necessary to protect its information technology resources. These systems and data are designed to support the Department's mission and business lines of energy security, nuclear security, scientific discovery and innovation, and environmental responsibility. The Federal Information Security Management Act of 2002 (FISMA) provides direction to agencies on the management and oversight of information security risks, including design and implementation of controls to protect Federal information and systems. As required by FISMA, the Office of Inspector General conducts an annual independent evaluation to determine whether the Department's unclassified cyber security program adequately protects its information systems and data. This memorandum and the attached report present the results of our evaluation for FY 2009. The Department continued to make incremental improvements in its unclassified cyber security program. Our evaluation disclosed that most sites had taken action to address weaknesses previously identified in our FY 2008 evaluation report. They improved certification and accreditation of systems; strengthened configuration management of networks and systems; performed independent assessments; and, developed and/or refined certain policies and procedures. In addition, the Department instituted a centralized incident response organization designed to eliminate duplicative efforts throughout the Department. As we have noted in previous reports, the Department continued to maintain strong network perimeter defenses against malicious intruders and other externals threats. These are positive accomplishments. However, in our judgment, additional action is required to further enhance the Department's unclassified cyber security program and help reduce risks to its systems and data. For example, our current review identified opportunities for improvements in areas such as security planning and testing, systems inventory, access controls, and configuration management. In particular, we issued a number of findings at sites managed by the National Nuclear Security Administration (NNSA). We also identified weaknesses across various Department program elements. Issues that warrant further attention include: (1) Weaknesses such as outdated security plans and not completing annual security control self-assessments were identified at several sites; (2) The Department had not yet resolved systems inventory issues and had yet to deploy a complex-wide automated asset management tool to help track information technology resources and identify interfaces between systems or networks; (3) Although certain improvements had been made to enhance access controls, we noted deficiencies such as a lack of periodic account reviews and inadequate password management at a number of sites; and (4) Previously identified weaknesses in configuration management had been corrected, however, we found problems related to weak administrator account settings and failure to install software patches, as well as incomplete implementation of the Federal Desktop Core Configuration. These internal control weaknesses existed, at least in part, because certain cyber security roles and responsibilities were not clearly delineated. Program officials also had not effectively performed monitoring and review activities essential for evaluating the adequacy of cyber security performance. In some cases, officials had not ensured that weaknesses discovered during audits and other evaluations were recorded and tracked to resolution in the organizations' Plans of Action and Milestones. Our testing disclosed that about 39 percent of existing corrective action milestones had missed estimated remediation dates, with many exceeding planned completion dates by at least one year. As a consequence, the risk of compromise to the Department's information and systems remained higher than necessary. To assist the continuing efforts to improve, we made several recommendations designed to help the Department's managers to strengthen the unclassified cyber security program and, thereby, protect its computer resources from unauthorized modification, loss, or disclosure of information. Due to security considerations, information on specific vulnerabilities and locations has been omitted from this report. Management officials at the sites evaluated were provided with detailed information regarding identified vulnerabilities, and, in many instances, initiated corrective actions.

99 GENERAL AND MISCELLANEOUS↗

Industrial IoT cross-layer forensic investigation

Cross-layer forensic investigation is addressed for Industrial Internet of Things (IIoT) device attacks in Critical Infrastructure (CI) applications. The operational motivation for cross-layer investigation is provided by the desire to directly correlate bit-level network anomaly detection with physical layer (PHY) device connectivity and/or status (normal, defective, attacked, etc.) at the time of attack. The technical motivation for developing cross-layer techniques is motivated by (a) having considerable capability in place for Higher-Layer Digital Forensic Information exploitation—real-time network cyberattack and postattack analysis, (b) having considerably less capability in place for Lowest-Layer PHY Forensic Information exploitation—the PHY domain remains largely under exploited, and (c) considering cyber-physical integration as a means to jointly exploit higher-layer digital and lowest-layer PHY forensic information to maximize investigative benefit in IIoT cyber forensics. A delineation of higher-layer digital and lowest-layer PHY elements is provided for the standard network Open Systems Interconnection model and the specific Perdue Enterprise Reference Architecture commonly used in IIoT Industrial Control System/Supervisory Control and Data Acquisition applications. Finally, a forensics work summary is provided for each delineated area based on selected representative publications and provides the basis for presenting the envisioned cross-layer forensic investigation.

97 MATHEMATICS AND COMPUTING↗

Influences of urea–glycerol mixtures as mixed mesopore-controlling agents on tailoring physicochemical properties and photocatalytic H{sub 2} production activity of sol–gel-derived mesoporous-assembled TiO{sub 2} nanocrystals

Graphical abstract: Display Omitted Highlights: ► Mesoporous-assembled TiO{sub 2} nanocrystals were synthesized by modified sol–gel process. ► Urea–glycerol mixtures were applied as mixed mesopore-controlling agents. ► Urea and glycerol contents affected physicochemical properties of synthesized TiO{sub 2}. ► Photocatalytic H{sub 2} production activity also depended on urea and glycerol contents. ► 75 mol% urea and 25 mol% glycerol yielded the most photocatalytically active TiO{sub 2}. -- Abstract: In this work, the mesoporous-assembled TiO{sub 2} nanocrystal photocatalysts were successfully synthesized by a sol–gel process with the aid of urea–glycerol mixtures used as mixed mesopore-controlling agents. The photocatalytic activity of the synthesized mesoporous-assembled TiO{sub 2} nanocrystal photocatalysts was investigated for hydrogen production from the water splitting reaction using methanol as a hole scavenger under UV light irradiation. The synthesized TiO{sub 2} nanocrystal photocatalysts were systematically characterized by TG–DTA, N{sub 2} adsorption–desorption, SEM, high resolution TEM, and XRD analyses. The characterization results showed that the well-controlled contents of urea and glycerol in a urea–glycerol mixture at 75 mol% urea and 25 mol% glycerol resulted in not only the most highly porous network (i.e. the highest specific surface area and total pore volume, and the smallest mean mesopore diameter), but also the smallest crystallite size of the synthesized TiO{sub 2} nanocrystal photocatalyst. The photocatalytic reaction results, hence, revealed a much superior photocatalytic hydrogen production activity of the mesoporous-assembled TiO{sub 2} nanocrystal synthesized with 75 mol% urea and 25 mol% glycerol to the other synthesized TiO{sub 2} nanocrystals, also being much higher than those of the commercially available P-25 TiO{sub 2} and ST-01 TiO{sub 2} powders.

36 MATERIALS SCIENCE↗

Nanoengineering Porous Silica for Thermal Management

Thermal insulation of solid materials originates from the nanoscale porous architectures to regulate thermal management in energy-critical applications from energy-efficient buildings to heat-sensitive energy devices. Here, we show nanoengineering of porous silica materials to control the architecture transition from mesoporous to nanocage networks. A low thermal conductivity of such a porous silica network is achieved at 0.018 W/(m K) while exhibiting a porosity of 92.05%, specific surface area of 504 m 2 /g, and pore volume of 2.37 cm 3 /g after ambient pressure drying. Meanwhile, the crosslinking of the porous silica and ceramic fiber frameworks show a tensile Young’s modulus of 2.8 MPa while maintaining high thermal insulation, which provides an effective thermal runway mitigation strategy for rechargeable lithium-ion batteries. Furthermore, the nanoengineering strategy reported here would shed light on achieving superthermal insulation of nanostructures for energy-critical applications.

36 MATERIALS SCIENCE↗

Surpassing the Organic Cathode Performance for Lithium-Ion Batteries with Robust Fluorinated Covalent Quinazoline Networks

Organic electrode materials have promising application prospects in energy storage, but issues including rapid capacity fading and poor power capacity restrict their practical applications. In this study, nanoporous fluorinated covalent quinazoline networks (F-CQNs) were constructed by condensation of fluorinated aromatic aminonitrile precursors via an ionothermal pathway. Precise control of the reaction parameters afforded F-CQN-1-600 material featuring high surface area, permanent porosity, high nitrogen content (23.49 wt %), extended π-conjugated architecture, layered structure, and bipolar combination of benzene and tricycloquinazoline. Synergy among these unique properties leads to a good performance as a cathode source for lithium-ion batteries (LIBs) in terms of high capacity (250 mA h g –1 at 0.1 A g –1 ), high rate capability (105 mA h g –1 at 5.0 A g –1 ), and impressive cycling stability (95.8% retention rate after 2000 cycles at 2.0 A g –1 together with a high Coulombic efficiency of 99.95%), surpassing most of the previous organic cathode counterparts.

25 ENERGY STORAGE↗

System and method for identifying, reporting, and evaluating presence of substance

A system and method for identifying, reporting, and evaluating a presence of a solid, liquid, gas, or other substance of interest, particularly a dangerous, hazardous, or otherwise threatening chemical, biological, or radioactive substance. The system comprises one or more substantially automated, location self-aware remote sensing units; a control unit; and one or more data processing and storage servers. Data is collected by the remote sensing units and transmitted to the control unit; the control unit generates and uploads a report incorporating the data to the servers; and thereafter the report is available for review by a hierarchy of responsive and evaluative authorities via a wide area network. The evaluative authorities include a group of relevant experts who may be widely or even globally distributed.

47 OTHER INSTRUMENTATION↗

Multi-resonant switched capacitor power converter architecture

A switched-capacitor (SC) network in an SC converter is controlled to operate at varying resonant modes to achieve high conversion ratio efficiency, at a low circuit component count. These power converters are suited to numerous application areas including improving energy efficiency of data centers. A family of resonant switched capacitor (SC) converters with multiple operating phases are presented “Multi-Resonant SC Converters”. Described in detail are an 8-to-1 Multi-Resonant-Doubler (MRD) converter and a 6-to-1 Cascaded Series-Parallel (CaSP). The topology of these converters make them amenable to combining like units in parallel toward reaching higher power levels.

Ye, Zichao↗

Human Supervision of Autonomous Vehicle Fleet Operations and Associated Passenger Communications: Preprint

Advances in automated vehicle (AV) technology and expanded operations are rapidly emerging with Automated Mobility District (AMD) deployments in global cities. NLR's AMD research addresses critical elements of human supervision of AV fleet operations and associated passenger communications for vehicles in which no driver or safety attendant is present. Although sufficiently advanced AVs no longer have direct oversight by a driver, fleet management remains staffed with operations personnel at the operations command and control (OCC) facility. This paper examines the functionality of the OCC, drawing comparisons of how automated train control and automated people mover OCCs operate. Within an AMD, the OCC manages various vehicle types, sizes, and operational modes, including on-demand and fixed route service, to facilitate a 'network of networks' for transport within a metropolitan area. The OCC serves as oversight for multiple AV fleets assisting AVs via remote operation of vehicles, communication, and dispatching personnel to resolve problems. The OCC also coordinates system operation, geographically staging vehicles, and managing weather, police, and emergency events. Informed by traffic management center (TMC) strategies using highly integrated software and communications, OCCs facilitate seamless information flows. OCC personnel remotely assist passengers and oversee multi-party operation to ensure safety and security. Although social norms mitigate large-capacity unattended vehicle operations, social interaction in multi-party automated small vehicles has little precedent. This poses a new frontier for society and requires research to effectively understand and manage. Future research will monitor OCC implementations, passenger interfaces, and deployment scaling of initial AMD systems.

33 ADVANCED PROPULSION SYSTEMS↗

Simulating the Impact of Dynamic Rerouting on Metropolitan-scale Traffic Systems

The rapid introduction of mobile navigation aides that use real-time road network information to suggest alternate routes to drivers is making it more difficult for researchers and government transportation agencies to understand and predict the dynamics of congested transportation systems. Computer simulation is a key capability for these organizations to analyze hypothetical scenarios; however, the complexity of transportation systems makes it challenging for them to simulate very large geographical regions, such as multi-city metropolitan areas. In this article, we describe enhancements to the Mobiliti parallel traffic simulator to model dynamic rerouting behavior with the addition of vehicle controller actors and vehicle-to-controller reroute requests. The simulator is designed to support distributed-memory parallel execution using discrete event simulation and be scalable on high-performance computing platforms. We demonstrate the potential of the simulator by analyzing the impact of varying the population penetration rate of dynamic rerouting on the San Francisco Bay Area road network. Using high-performance parallel computing, we can simulate a day in the San Francisco Bay Area with 19 million vehicle trips with 50 percent dynamic rerouting penetration over a road network with 0.5 million nodes and 1 million links in less than three minutes. We present a sensitivity study on the dynamic rerouting parameters, discuss the simulator’s parallel scalability, and analyze system-level impacts of changing the dynamic rerouting penetration. Furthermore, we examine the varying effects on different functional classes and geographical regions and present a validation of the simulation results compared to real-world data.

97 MATHEMATICS AND COMPUTING↗