Search NASA⌕ Search

SEARCH · Search NASA

Results for “controller tools”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Power system model parameter conditioning tool

A power system model parameter conditioning tool including a server control processor in communication with phasor measurement unit monitored data records of multiple disturbance events, a model calibration unit providing event screening, power system model simulation, and simultaneous tuning of model parameters. The model calibration performing a simulation using default model parameters, the processor comparing the simulation results to the monitored data. If the prediction is within threshold, then terminating conditioning; else performing parameter identifiability analysis to determine differing effects of various model parameters on power system model accuracy, selecting a parameter set causing a degradation in power system model prediction, and updating the default model parameters corresponding to members of the parameter set with values selected to reduce the degradation. A method and a non-transitory computer readable medium are also disclosed.

Baone, Chaitanya Ashok↗

Explainable discrepancy checker and diagnosis for digital Twin-based supervisory control system

By virtually representing a physical object and process, a digital twin (DT) enables optimal autonomous operations by combining classical and novel frameworks in sensors, state predictions, and multi-input/multi-output systems. A DT’s values depend on how well models estimate quantities of interest and on how uncertainty is handled. Moreover, DTs often combine physics-based and data-driven models with mixed fidelities, where classical uncertainty quantification (UQ) struggles with many sources of uncertainty and real-time constraints. Here, this work presents a UQ-based discrepancy checking and diagnosis tool for a DT-based supervisory control system. The tool is developed using metadata from an automated DT development process to learn correlations between sources of uncertainties and outcomes. During operation, it compares predictions with measurements, attributes discrepancies to dominant sources, and recommends parameter and configuration updates. We verify the workflow on a synthetic temperature-control problem and deploy it on a virtual Thermal Energy Delivery System, reducing mismatch and improving control robustness.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Controlled Environment Agriculture SiteScout (CEA SiteScout) v1.0

This is a geospatial online decision support tool designed to help identify locations where controlled environment agriculture (CEA) can be cited to take advantage of energy and water resources. It also quantifies the benefits of selected energy and water efficiency measures.

Stokes-Draut, Jennifer [Lawrence Berkeley National↗

An Analysis of Grid Operator Survey Responses: Inexperience, Workload and Fatigue in the Control Room

Although a wide array of tools and technologies have been developed over the last decade to support power grid operators, deployment of these tools has been less successful. One reason for unsuccessful deployment may be an inadequate understanding of the factors that contribute to operator error in the control room. An analysis of operators’ current vulnerabilities may provide the baseline understanding needed to inform new technology integration. In an attempt to learn more about these vulnerabilities and their perceived impact on human error we collected and analyzed survey data from 20 electric grid control room operators. We asked survey respondents to consider the various operator, technology and interaction vulnerabilities that may arise during work in the control room and record their attitudes and experiences toward each. Results suggest operator inexperience, high mental workload and fatigue are the most common vulnerabilities experienced during a shift. Survey results were analyzed to explore these vulnerabilities in greater depth.

Inexperience, Workload, Fatigue↗

Constraining Physical Understanding of Aerosol Loading, Biogeochemistry, and Snowmelt Hydrology from Hillslope to Watershed Scale in the East River Scientific Focus Area

The mountain snowpack is a critical component of regional hydrology, ecology, biogeochemistry, and climate in the Western US. This project leveraged the East River Scientific Focus Area (SFA), as an outdoor laboratory to address a significant gap in our understanding of the mountain snowpack; namely, how atmospheric constituent deposition on snowpack influences snow energy balance and nutrient/chemical cycling, and how snowmelt timing and intensity exerts controls on emergent biogeochemical and ecohydrologic behavior. This aligned with East River SFA goals to integrate landscape scale measurements and physical based modeling tools to improve understanding of controls on runoff production, ecohydrology, biogeochemical cycling, and land surface energy partitioning in high mountain watersheds. The project included observations of snowpack at multiple scales, measurements of snow and deposited aerosols properties, in situ time series of surface energy balance, and spatially distributed, process-based snowmelt modeling.

54 ENVIRONMENTAL SCIENCES↗

WHOC (Wind Hybrid Open Controller) [SWR-25-54]

The Wind Hybrid Open Controller (WHOC) is a python-based tool for real-time plant-level wind farm control and wind-based hybrid plant control. WHOC is primarily run in simulation, although we intend that it could be used for physical plants in future. WHOC provides simple farm-level (and hybrid plant-level) controls such as wake steering control, spatial filtering/consensus, active power control, and coordinated control of hybrid power plant assets; and creates an entry point for the development of more advanced controllers.

Sinner, Michael (Misha) [National Renewable Energy↗

Safe Physics-Informed Machine Learning for Dynamics and Control

This tutorial paper focuses on safe physics-informed machine learning in the context of dynamics and control, providing a comprehensive overview of how to integrate physical models and safety guarantees. As machine learning techniques enhance the modeling and control of complex dynamical systems, ensuring safety and stability remains a critical challenge, especially in safety-critical applications like autonomous vehicles, robotics, medical decision-making, and energy systems. We explore various approaches for embedding and ensuring safety constraints, including structural priors, Lyapunov and Control Barrier Functions, predictive control, projections, and robust optimization techniques. Additionally, we delve into methods for uncertainty quantification and safety verification, including reachability analysis and neural network verification tools, which help validate that control policies remain within safe operating bounds even in uncertain environments. The paper includes illustrative examples demonstrating the implementation aspects of safe learning frameworks that combine the strengths of data-driven approaches with the rigor of physical principles, offering a path toward the safe control of complex dynamical systems.

Drgona, Jan↗

Turbine-based Power System Tool

Advanced research tools are essential to illustrate the effects of turbine-based power system operations on the electric grid network. This paper presents the development of an open-source tool to visualize the operation of turbine-based electricity generation. The tool exposes power system models, control parameters, and corresponding values of the turbine model and its electrical system, allowing them to customize the simulation according to their needs. The developed tool enables users to simulate power profiles for different turbinebased energy generation such as wind, tidal, and gas turbines. It allows users to investigate the details of the generated profiles of various types of turbine systems at various scales. It can provide valuable insights into model development and facilitate the analysis of integrated power systems. By enabling access to turbine-based operations visualization, the tool aims to bridge the gap between advanced research tools and users, facilitating broader adoption of renewable energy technologies and aiding in developing sustainable power systems.

Kini, Roshan L.↗

225 Ac/ 213 Bi Generator Based on Millifluidics Controlled Electrodeposition

Radioisotopes provide both diagnostic tools and therapeutic treatments for cancer and other diseases. In the US, millions of radioisotope doses are given to patients per year. Radiopharmaceutical generators are widely used to provide such short-lived medical radioisotopes in a clinical setting. These generators work by exploiting chemical differences in a parent/daughter isotope relationship. Actinium-225 (half-life 10 d) is used to provide clinically useful amounts of daughter isotopes 213 Bi (46 m). An integrated millifluidic 225 Ac/ 213 Bi radiopharmaceutical generator device was engineered to produce 213 Bi labeled biomolecules. Using recent LANL successes in additive manufacturing of small-scale fluidic devices, a disposable device was developed that integrates three steps for the production of 213 Bi labeled antibodies: 1) 213 Bi separation from 225 Ac parent, 2) 213 Bi antibody labeling, and 3) purification of the labelled antibody.

213Bi↗

Haxall-based (Axon) fault auto-correction package for building HVAC system (Haxall-based Fault Correction) v1.0

Haxall-based Fault Correction is a set of fault auto-correction algorithms implemented using the Axon language. These algorithms can automatically fix equipment and control problems as they arise and improve the operation of building Heating, Ventilation, and Air Conditioning (HVAC) systems. The coded auto-correction algorithms include mitigation of rogue zones, ASHRAE Guideline 36 static pressure and supply air reset, resolution of control hunting due to improper settings in a proportional-integral-derivative controller, correction of biased temperature sensors, etc. FDD tools with enhanced auto-correction capability can resolve control problems as they are detected, increasing energy savings and emissions reductions while freeing up operational staff expertise for the hardest facility problems.

Vitti, Raphael↗

Strym: A Python Package for Real-time CAN Data Logging, Analysis and Visualization to Work with USB-CAN Interface

In this report, we describe a data analysis tool developed for decoding and analyzing vehicle data obtained from a passenger vehicle’s onboard controller area network (CAN) bus. The tool developed in this paper provides a timeseries framework to perform domain-specific analysis at scale when interpreting data from a vehicle or a collection of vehicles in light of how to design intelligent vehicle applications. The tool, called Strym, exploits the CAN bus mechanism of modern vehicles to capture data using commercially available CAN-to-USB hardware Comma.ai Panda devices, managed through open-source software Libpanda. Strym permits the decoding of vendor-specific CAN messages in a vehicle-agnostic manner. Through this, a researcher can characterize data throughput, assess data quality, and perform analyses. Such analyses are useful in a number of research such as studying human driving behavior in mixed-autonomy, new driver models, rare-event detection, traffic flow estimation, and custom control of vehicles.

Performance evaluation, Smart cities, Intelligent ↗

Considerations for AMI-Based Operations for Distribution Feeders

More than $5 billion in investments in advanced metering infrastructure (AMI) technologies, AMI deployments, as pervasive secondary network voltage monitoring systems, provide opportunities for utility operations and controls. This paper focuses on the considerations for AMI-based tools and techniques as the industry moves toward operationalizing such large data sets. Phase identification is a first such tool. Numerous distribution network analysis, monitoring, and control applications - including volt/volt-ampere reactive control, state estimation, and distribution automation - require accurate phase connectivity information in the system models. The phase connectivity database maintained by utilities is inaccurate because of a significant amount of missing data, restoration activities, and network reconfiguration. Existing phase identification techniques that estimate phase connectivity work well in distribution feeders that have low or no photovoltaic (PV) generation; however, they fail to identify the phases accurately when considerable PV generation is present. This work addresses the phase identification problem in the presence of high PV generation using statistical analysis methods. Further, insights into the AMI data requirements for this application in terms of data window length and resolution are provided using sensitivity analysis performed on an actual distribution feeder model of San Diego Gas & Electric Company. The results of this study show that the phase connectivity, even in the presence of high PV generation, can be accurately identified using statistical analysis of AMI data of 1 day.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Perspectives on Next Steps in Arms Control and Non-Proliferation

Much has happened in arms control over the last year as this chapter has been in development. The prospects for arms control as a viable national security tool have, if anything, grown darker. Russia has falsely equated tearing down the remaining arms control edifice with creating potential leverage vis-à-vis its actions in Ukraine. China has failed to update its talking points on being a responsible arms control actor with its massive nuclear force expansion. The United States has stated clearly that it is open for business on arms control and risk reduction, but it unfortunately has no customers in Russia and China. It remains unclear what specifically the United States is selling in terms of what it wants in a potential agreement. Competitive dynamics and an atmosphere of great power competition are driving all parties further away from the table.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Report for Task 15: Developed Tool Verification/Validation Report (Deliverable D11): AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency

This report summarizes the verification report for the developed modules. The team conducted verification in two phases. In phase 1, the modules were validated using offline validation methods and in phase 2 the modules were subjected to real-time validation. This report outlines the approach and the results for the modules under offline and real-time settings. The rest of the report details the functional workflow of AGGREGATE modules, we then transition to offline validation followed by real-time validation of modules. We conclude the report by discussing some of the key points of this report.

14 SOLAR ENERGY↗

Sliding Mode Network Perimeter Control

Urban traffic congestion is a chronic problem faced by many cities in the US and worldwide. It results in inefficient infrastructure use as well as increased vehicle fuel consumption and emission levels. Congestion is intertwined with delay, as road users waste precious hours on the road, which in turn reduces productivity. Researchers have developed, and continue to design, tools and systems to alleviate this problem. Network perimeter control is one such tool that has been studied extensively. It attempts to control the flow of vehicles entering a protected area to ensure that the congested regime predetermined by the Network Fundamental Diagram (NFD) is not reached. In this paper, a method derived from sliding mode control theory is presented. Its main advantages over proportional-integral controllers include (1) minimal tuning, (2) no linearization of the governing equations, (3) no assumptions with regard to the shape of the NFD, and (4) ability to handle various demand profiles without the need to retune the controller. A sliding mode controller was implemented and tested on a congested grid network. The results show that the proposed controller produces network-wide delay savings and disperses congestion effectively.

42 ENGINEERING↗

Genotype-dependent contribution of CBF transcription factors to long-term acclimation to high light and cool temperature

When grown under cool temperature, winter annuals upregulate photosynthetic capacity as well as freezing tolerance. Here, the role of three cold-induced C-repeat-binding factor (CBF1–3) transcription factors in photosynthetic upregulation and freezing tolerance was examined in two Arabidopsis thaliana ecotypes originating from Italy (IT) or Sweden (SW), and their corresponding CBF1–3-deficient mutant lines it: cbf123 and sw: cbf123 . Photosynthetic, morphological and freezing-tolerance phenotypes, as well as gene expression profiles, were characterized in plants grown from the seedling stage under different combinations of light level and temperature. Under high light and cool (HLC) growth temperature, a greater role of CBF1–3 in IT versus SW was evident from both phenotypic and transcriptomic data, especially with respect to photosynthetic upregulation and freezing tolerance of whole plants. Overall, features of SW were consistent with a different approach to HLC acclimation than seen in IT, and an ability of SW to reach the new homeostasis through the involvement of transcriptional controls other than CBF1–3. These results provide tools and direction for further mechanistic analysis of the transcriptional control of approaches to cold acclimation suitable for either persistence through brief cold spells or for maximisation of productivity in environments with continuous low temperatures.

59 BASIC BIOLOGICAL SCIENCES↗

Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates

Smart Ventilation has been developed as a way to reduce the energy associated with ventilation by changing when ventilation happens and how much ventilation occurs at any given time. In high performance buildings with low envelope and appliance related loads, ventilation is becoming a bigger part of the total building energy use and needs to be addressed if performance targets are to be met. This work explores the development and performance of smart ventilation controls based on occupancy and auxiliary fan operation that provide annual dwelling unit ventilation equivalence to ASHRAE Standard 62.2-2016. A prototype high performance home compliant with U.S. DOE Building America Zero Energy Ready program requirements was simulated using the REGCAP tool with and without smart controls across 15 U.S. DOE climate zones. Balanced and unbalanced IAQ fans were independently simulated, and all smart controlled fans had airflows double the reference 62.2-2016 airflow. Three idealized occupancy patterns were examined: 1st shift (a typical daily work/school absence), an extended 1st shift with more time spent out of the home evenings and weekends and 3rd shift (night work). The Occupancy controller turns the IAQ fan off during unoccupied periods, and it resumes ventilation upon their return. While unoccupied, contaminants are allowed to accumulate in the space, because occupants are not exposed to these contaminants. When occupants return home, they are exposed to these higher contaminant concentrations, and the controller increases the ventilation rate sufficiently to ensure equivalence with a continuous IAQ fan. Accounting for pollutant emissions that occur during unoccupied periods (as required by ASHRAE 62.2-2016), sharply distinguishes our occupancy controls from past Demand Controlled Ventilation systems. This new accounting method results in equivalent contaminant exposure, as well as lower reductions in average ventilation rates and lower energy savings. Smart controls were demonstrated that saved HVAC energy (i.e., avoided heating/cooling load, as well as fan energy)—averaging between 6 and 46% of ventilation-related energy use depending on the control strategy and occupancy pattern assumptions. The greatest savings were in the combined Auxiliary Fan + Occupancy control. Energy savings increased with climate heating demand and longer unoccupied time periods. The 3rd shift occupancy pattern had better performance, due to the thermal benefit of reducing the ventilation rate during the cold nighttime hours. This same effect provided a cooling energy benefit in hotter locations for the 1st shift. Overall, savings from occupancy-based smart controls were low, because of the recovery period required after occupants return home, during which the airflow is double the 62.2 reference. This recovery is required to maintain equivalence with the ASHRAE standard. Occupancy-based control performance was improved when combined with sensing auxiliary fans and when providing a pre-occupancy flush out of one- or two-hours. Performance was similarly improved if the ASHRAE Standard were to recognize that pollutant emissions are lower during unoccupied periods, iii allowing a lower target ventilation rate during unoccupied periods (not currently in the standard) (see Full vs. Half AEQ in this report). Finally, over-sized unbalanced fans that are cycled on-and-off by a smart controller (or timer) were found to substantially increase annual average air exchange and energy use relative to a continuous unbalanced fan due to the effects of superposition with natural infiltration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗