Search NASA⌕ Search

SEARCH · Search NASA

Results for “cooling load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Geologic Seawater Air Conditioning (GeoSWAC) System: Resource Assessment and Techno-Economic Evaluation in Puerto Rico

Puerto Rico's hot, humid climate drives a high and persistent demand for cooling, straining an aging and fuel-dependent energy grid while increasing peak electricity loads. Much of this challenge stems from inefficient air-conditioning systems operating in buildings without passive cooling design, making cooling both costly and vulnerable to disruption - especially during hurricanes. To address these issues, researchers evaluated a new alternative called Geologic Seawater Air Conditioning (GeoSWAC), which uses inland wells connected to naturally cold, deep seawater. By avoiding long offshore pipelines and energy-intensive refrigeration cycles, GeoSWAC can cut electricity use by 75-90%, reduce environmental impacts, and operate more reliably during power outages. A case study at the University of Puerto Rico's Rio Piedras campus found that GeoSWAC could deliver significantly lower levelized costs of cooling, reduced operational expenses, and improved water conservation compared to the campus's existing chilled-water plant. The system offers key advantages - including access to a constant cold heat sink, low pumping requirements, and enhanced resilience - for coastal regions such as Puerto Rico, the broader Caribbean, and Florida. However, its effectiveness depends heavily on site-specific geological conditions, such as subsurface connectivity and aquifer characteristics, which require detailed investigation. Future research should refine hydrogeological models, conduct performance and economic analyses, and address regulatory and permitting frameworks to support broader adoption of this promising technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A cantilevered liquid-nitrogen-cooled silicon mirror for the Advanced Light Source Upgrade

This paper presents a novel cantilevered liquid-nitrogen-cooled silicon mirror design for the first optic in a new soft X-ray beamline that is being developed as part of the Advanced Light Source Upgrade (ALS-U) (Lawrence Berkeley National Laboratory, USA). The beamline is optimized for photon energies between 400 and 1400 eV with full polarization control. Calculations indicate that, without correction, this design will achieve a Strehl ratio greater than 0.85 for the entire energy and polarization ranges of the beamline. With a correction achieved by moving the focus 7.5 mm upstream, the minimum Strehl ratio is 0.99. This design is currently the baseline plan for all new ALS-U insertion device beamlines.

47 OTHER INSTRUMENTATION↗

Technology Development and Field Monitoring in nZEB - US Country report IEA HPT Annex 49 Task 3

The International Energy Agency (IEA) Heat Pumping Technologies (HPT) Annex 49, “Design and Integration of Heat Pumps for Nearly Zero Energy Buildings,” deals with the application of heat pumps (HPs) as a core component of the HVAC system for nearly or net-zero energy buildings. This report covers the Task 3 activities of the US team. Three institutions are involved on the US team and have worked on the following projects. 1) Oak Ridge National Laboratory (ORNL) summarized development activities since the conclusion of IEA HPT Annex 40 for several integrated HP (IHP) systems - electric ground-source IHP and air-source IHP versions and engine-driven AS-IHP version. 2) The University of Maryland partnered with ORNL and Blue Bear Management to develop a personal cooling device called RoCo that can provide personalized conditioned air to occupants in inadequately or unconditioned environments. With RoCo, building facility management can elevate the HVAC thermostat settings without compromising occupants’ thermal comfort. Researchers have found that a 4°F increase in thermostat settings can save 12–30% energy savings. Therefore, RoCo is a promising technology that can help reduce building energy consumption and facilitate achievement of net-zero energy building performance. 3) The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net-Zero Energy Residential Test Facility. Two air-source split-system HPs were installed in a residential, net-zero energy home that was constructed as a laboratory on the NIST campus in Gaithersburg, Maryland. The first HP was a two-stage, 7 kW (2 ton), 15.8 seasonal energy efficiency ratio (SEER), 9.05 heating seasonal performance factor (HSPF) conventionally ducted system; the second HP was a variable-speed, 10.6 kW (3 ton), 14 SEER, 8.35 HSPF, high-velocity ducted system. These two systems operated side by side, using separate supply ducts and a common return duct, on a weekly alternating schedule to condition the home that was operated with very consistent simulated thermal loads. The team wanted to determine whether the high-velocity system could provide comparable energy-use efficiency to the conventional system. The results of this study showed that it did meet the required loads and had slightly greater efficiency; the average cooling coefficient of performance (COP) was (0.40 ± 0.11) higher, and the average heating COP was statistically equal. A new firmware was provided at the end of the heating season that greatly improved the performance of the high-velocity system; its average heating COP went from (1.8 ± 0.9) to (2.5 ± 1.1) at a 95% confidence level. The new firmware heating COP averaged (1.05 ± 0.23) higher than the old firmware over the same outdoor temperatures. The defrost performance is very different for these two systems, yet they consumed equivalent energy per HDD. The conventional system uses a timed-initiate, temperature-terminate algorithm with auxiliary electric resistive heating, whereas the high-velocity system uses calculated evaporator parameters with a hot-gas bypass before a full reverse-cycle defrost with no supplementary resistive heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Horizontal 1 K refrigerator with novel loading mechanism for polarized solid targets

We describe a helium evaporation refrigerator used to cool dynamically polarized proton and deuteron targets for electron-scattering experiments using the CEBAF Large Acceptance Spectrometer CLAS12 at Jefferson Lab. The geometry of the CLAS12 detector systems places severe design and construction constraints on the refrigerator and its ancillary equipment, resulting in a horizontal cryostat with a length of 4 m. The 16 cm 3 target samples, consisting of frozen ammonia (NH 3 or ND 3 ), are loaded at the upstream end of the cryostat and moved to the beam-interaction region using a novel transport mechanism. At this location they are cooled with superfluid helium and polarized via dynamic nuclear polarization at 1 K and 5 T. In this manner samples can be replaced and cooled to 1 K in about 30 minutes without disturbing any elements of the electron beam line or particle detection system. In conclusion, we estimate that this method saved 18 days of valuable beam time over the course of a recent, 88-day long experiment.

Evaporation refrigerator↗

Enhanced Air-Cooling System with Optimized Asynchronously-Cooled Thermal Energy Storage

A transformative dry-cooling system that includes two primary dry-cooling components has been developed in this project. The two main features of this new technology consist of: (a) an ultra-enhanced air-cooled condenser (ACC), with novel swirl-producing and boundary-layer disrupting enhanced surface on the air-side of the condenser that substantially increase the heat transfer coefficients, and (b) a novel daytime peak-load shifting system that reduces the ambient air inlet temperature for air cooling, consisting of a highly compact and enhanced air pre-cooler that transfers the heat load to a unique thermal energy storage (TES), and which is coupled to the ACC in (a).

20 FOSSIL-FUELED POWER PLANTS↗

Identifying Regions Favorable for Geothermal Heating and Cooling Storage

Space heating and cooling represents the single largest category of in building energy use for U.S. residential and commercial buildings, with heating representing 61% of residential and 46% commercial energy consumption. Building heating technologies are dominated by natural gas technologies, and are an important opportunity for building electrification to enable a transition to a low CO 2 energy system. FLXenabler study is a joint analysis effort among multiple analysis teams at NREL and focused on examining the role of geothermal heating and cooling (GHC) system with thermal energy storage (TES) providing flexibility. Utilizing information from ResStock the amount of energy consumption associated with heating and cooling by state was calculated. We applied adjusted load shapes to estimate the a maximum grid savings potential of using TES to address building space conditioning. Normalizing grid, fuel, and emissions impacts locations with higher favorability for further study in FLXenabler were identified.

15 GEOTHERMAL ENERGY↗

Thermal Charging Rate of Composite Wax-Expanded Graphite Phase Change Materials

Phase change materials (PCMs) are valuable for their ability to store heat nearly isothermally around their phase transition temperature. PCMs are at the core of latent heat thermal energy storage (LHTES) systems, which provide the ability to buffer high thermal loads or decouple the time when heating or cooling is needed from when it is produced. Thermal charging and discharging of LHTES systems often employ a constant temperature source, and the rate at which heat can be exchanged is dependent on the thermophysical properties of the PCM. For graphite composite PCMs, the high thermal conductivity of the graphite enables an increased heat transfer rate through the material, but its presence displaces PCM which reduces the effective volumetric latent heat of the composite relative to the pure PCM. This results in a tradeoff between thermal power and volumetric energy storage capacity. The thermal charging rate is the average thermal energy stored in the material for some elapsed time. In this study, composite PCMs of compressed expanded natural graphite (CENG) and n-Octadecane are studied. Samples with varying CENG mass fractions were synthesized and the thermal charging rate was measured under a constant temperature boundary condition. For evaluation of the expanded graphite-PCM composite, one boundary of the material was exposed to a 50°C constant temperature plate, above the 27.5°C melting temperature of the PCM. The melting front progression [mm-s-1] and the thermal charging rate [W-cm-2] of the PCM were determined, and the results were compared with analytical predictions for the 1-D semi-infinite phase change. For CENG addition up to 5.75% mass fraction, a 450% thermal conductivity increase was observed with a 5% decrease in volumetric energy density as compared to pure octadecane. The average thermal charging rate was increased by over 430% for the melt to penetrate a depth of 22 mm. The experimental results matched analytical predictions, indicating that higher CENG fractions can be evaluated using analytical approaches.

Hirschey, Jason↗

Energy characteristics of multi-chiller load distribution algorithms in a large office building

Here, this study evaluates the energy efficiency of multi-chiller systems in large office buildings, focusing on their optimization across various climate zones as defined by ASHRAE. Using EnergyPlus for simulations, the research examines five different load distribution algorithms in multi-chiller systems that range from one to ten chillers, aiming to understand their effectiveness in 15 distinct climate zones. The primary objectives of the study include identifying the energy efficiency of multi-chiller systems in each climate zone, determining the appropriate number of chillers for each zone, and evaluating the performance of the load distribution algorithms. Based on the U.S. Department of Energy’s commercial building model, the results suggest that multi-chiller systems can significantly reduce cooling energy consumption in various climates. Among the algorithms evaluated, the Sequential Uniform Part Load Ratio (SUPLR) algorithm demonstrates notable efficiency, especially in the 4A climate zone (Baltimore), where it achieves substantial energy savings. Applying the SUPLR algorithm in a multi-chiller setup with four chillers in this zone leads to an estimated 24.5 % reduction in energy usage, equivalent to 183 MW annually. The research indicates that a range of 3 to 5 chillers is typically optimal for most climate zones. In-depth analysis in the 4A climate zone highlights the importance of minimizing operation hours at low Part Load Ratios (PLR) to ensure that chillers operate at a high Coefficient of Performance (COP). This strategy underscores the potential of well-designed multi-chiller systems to reduce cooling energy demand, particularly in climates with transitional seasons. This study provides an overview of the energy-saving potential of multi-chiller systems, applicable across a variety of climatic scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation Gap Assessment of a MAP Package Containing Fresh, Metallic Sodium-Cooled Fuel

This report describes an assessment of sodium fast reactor assemblies loaded within an AREVA MAP package. The assessment was performed to determine the state of the validation basis for sodium fast reactor fuel within a transportation package originally intended for fresh, light-water reactor fuel assemblies. A similar study is being simultaneously released (Cumberland, 2025), and substantial parts of the explanatory text are identical to that parallel work, which follows the same workflow. Both studies employed the TSUNAMI-3D and TSUNAMI-IP sequences from the SCALE code system to determine correlation coefficients between various configurations and databases of validation assessments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation Gap Assessment of a TN B1 Package Containing Fresh, Metallic Sodium-Cooled Fuel

This report describes an assessment of sodium fast reactor assemblies loaded inside a Transnuclear B1 package. The assessment was performed to determine the state of the validation basis for sodium fast reactor fuel within a transportation package originally intended for fresh, light-water reactor fuel assemblies. The study employed the TSUNAMI-3D and TSUNAMI-IP sequences from the SCALE code system to determine correlation coefficients between various configurations and databases of validation assessments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effectiveness of street trees in reducing air temperature and outdoor heat exposure in Las Vegas

Urban greening and especially tree planting strategies are being widely planned and implemented to mitigate urban overheating and thermal stress in many urban areas. However, the effectiveness of these strategies depends on multiple factors, including urban morphology, environmental conditions, and tree characteristics. This study investigates the effects of street tree planting strategies on air temperature and outdoor heat exposure in Las Vegas by combining an urbanized mesoscale climate model coupled to a multi-layer street tree model (Weather Research and Forecasting-BEP-Tree; Δ x = 900 m) with a microscale pedestrian heat exposure model (Temperatures of Urban Facets for Pedestrian; Δ x = 1 m). A series of simulations are conducted for July and August 2022. Large city-wide increases of a drought tolerant tree species cool air temperature mainly during the nighttime (up to 1.5 °C), with daytime effects being limited due to leaves shedding sensible instead of latent heat as stomata close in response to high vapor pressure deficits. Increased evaporative cooling is achieved with a different tree species (double at night, and reaching 0.4 °C during the day), but water requirements increase threefold. Despite their relatively small effect on air temperature during the day, trees provide significant shade by intercepting solar radiation, reducing mean radiant temperature (up to 16 °C) and enhancing outdoor thermal comfort, a major benefit of street trees in hot arid climates. The nighttime cooling of trees and the daytime reduction of radiant loading show potential to reduce the heat-related health impacts. Our results highlight the need to evaluate the effects of street trees on a case-by-case basis.

54 ENVIRONMENTAL SCIENCES↗

QUOKKA-based understanding of outflows (QED) – III. Outflow loading and phase structure as a function of galactic environment

ABSTRACT We present results from a suite of 3D high-resolution hydrodynamic simulations of supernova-driven outflows from galactic disc regions with a range of gas surface density, metallicity, and supernova scale height. We use this suite to quantify how outflow properties – particularly the loading factors for mass, metallicity, and energy – vary with these parameters. We find that the winds fall into three broad categories: steady and hot, multiphase and moderately bursty, and cool and highly bursty. The first of these is characterized by efficient metal and energy loading but weak mass loading, the second by moderate loading of mass, metals, and energy, and the third by negligible metal and energy loading but substantial mass loading. The most important factor in determining the kind of wind a galaxy will produce is the ratio of supernova to gas scale heights, with the latter set by a combination of supernova rate, metallicity-dependent cooling rate, and the gravitational potential. These often combine in counterintuitive ways – for example increased cooling causes cold clouds to sink into the galactic midplane more rapidly, lowering the volume-filling factor of dense gas and making the environment more favourable for strong winds. Our findings suggest that the nature of galactic winds is likely highly sensitive to phenomena such as runaway stars occurring at a large height and dense gas and are poorly captured in most simulations, and that metal loading factors for type Ia supernovae may be substantially larger than those for type II, with important implications for galactic chemical evolution.

Vijayan, Aditi (ORCID:0000000277142379)↗

The Simons Observatory: Cryogenic half wave plate rotation mechanism for the small aperture telescopes

We present the requirements, design, and evaluation of the cryogenic continuously rotating half-wave plate (CHWP) for the Simons Observatory (SO). SO is a cosmic microwave background polarization experiment at Parque Astronómico de Atacama in northern Chile that covers a wide range of angular scales using both small (Ø0.42 m) and large (Ø6 m) aperture telescopes. In particular, the small aperture telescopes (SATs) focus on large angular scales for primordial B-mode polarization. To this end, the SATs employ a CHWP to modulate the polarization of the incident light at 8 Hz, suppressing atmospheric 1/f noise and mitigating systematic uncertainties that would otherwise arise due to the differential response of detectors sensitive to orthogonal polarizations. The CHWP consists of a 505 mm diameter achromatic sapphire HWP and a cryogenic rotation mechanism, both of which are cooled down to ~50 K to reduce detector thermal loading. Under normal operation, the HWP is suspended by a superconducting magnetic bearing and rotates with a constant 2 Hz frequency, controlled by an electromagnetic synchronous motor. We find that the number of superconductors and the number of magnets that make up the superconducting magnetic bearing are important design parameters, especially for the rotation mechanism’s vibration performance. The rotation angle is detected through an angular encoder with a noise level of 0.07 μrad √ $\overline{s}$. During a cooldown process, the rotor is held in place by a grip-and-release mechanism that serves as both an alignment device and a thermal path. In this paper, we provide an overview of the SO SAT CHWP: its requirements, hardware design, and laboratory performance.

47 OTHER INSTRUMENTATION↗

Divertor Plasma Detachment Control Neural Network

DivControlNN is a state-of-the-art software tool that leverages advanced machine learning techniques to predict and control divertor plasma behavior in fusion reactors. Plasma, a highly energetic and electrically charged gas, requires meticulous management to protect reactor components and maintain optimal energy production. Conventional simulation methods, although extremely detailed, typically demand extensive computational time-making them unsuitable for real-time control scenarios. DivControlNN addresses this challenge by learning from tens of thousands of high-fidelity simulations, thereby creating a rapid surrogate model that can deliver near-instantaneous predictions. At the core of its functionality is a sophisticated technique known as latent space mapping, which condenses complex, high-dimensional plasma data into a compact, lower-dimensional representation. This streamlined representation enables the system to quickly forecast essential plasma properties and determine the precise conditions required for effective detachment. Detachment is a crucial process in which the plasma is cooled before reaching the divertor plates, thereby reducing heat loads and mitigating material erosion. In recent experiments conducted on the KSTAR tokamak in South Korea, DivControlNN successfully guided the detachment process without any fine-tuning-even when applied to a new tungsten divertor configuration. By achieving a computational speed-up of over one hundred million times compared to traditional simulation methods while maintaining low prediction errors, DivControlNN stands to significantly enhance real-time control and diagnostic capabilities in future fusion reactors. This breakthrough paves the way for safer, more reliable reactor operation and represents a major advancement toward realizing fusion energy as a practical, sustainable, and clean power source.

Xu, Xueqiao [Lawrence Livermore National Laborator↗

Modeling Advanced Strippers for CO2 Capture from Gas-Fired Power Plants using Aqueous Piperazine

Energy performance of 5 m piperazine was evaluated with an advanced stripper at the pilot scale, accounting for heat loss. Modeling studies indicated that heat loss at locations other than the heat source impacted the heat duty. For strippers with excess packing, the column was the most important source of heat loss, and values as low as 0.03 GJ/hr can cause pinch and reabsorption of CO2. Solvents like 5 m PZ are more affected by heat loss in the column due to a top-side temperature pinch at high lean loading. Heat loss impacts NGCC CO2 capture more than coal-based CO2 capture. Surface temperature measurements pilot plants showed that heat loss was 50-75% controlled by natural convection. Measured heat loss was correlated with steam flowrate and wind speed and ranged from 8126 to 219668 Btu/hr, representing 35% of the measured heat rate on average. Net heat duty linearly varied with CO2 removal at low lean loading and was similar for coal and NGCC conditions at fixed removal. At 90% removal, net heat duty was about 2.5 GJ/t with 4 and 12% CO2 in the flue gas. 7 At NGCC conditions, strippers with finite packing can benefit from a flashing feed to the top of the column by using a hot bypass. A flashing feed was linked to a reduction in irreversibility of the stripper from temperature driving forces. It also reduces heat duty by up to 6% at fixed packing height and reduces packing requirement for a fixed steam heater size compared to a warm bypass. Lean loading and lean solvent rate were effective handles to maximize profitability of a fixed stripper design at low gas price. High ambient temperature operation can benefit from low pressure stripping to about 0.18 lean loading at 150 ℃ to maintain the cyclic capacity at reduced rich loading. At low gas price, the capture plant was able to maximize profitability even with a high heat duty of 2.7-3.1 GJ/t at a lean loading of 0.2-0.22 mol/mol. Heat recovery by partial water vapor condensation in a gas-liquid exchanger can be replaced by a direct contact condenser (DCC). The DCC improved gas cooling and reduced heat duty compared to the CO2 exchanger at 0.2 lean loading. The DCC when used with a 150 ℃/5.5 bar stripper can reduce the cost of capture compared to the base case by $3- 4/tonne at 15 ft of packing (optimum) but increases cost of capture by $6/tonne with a 120 ℃/2 bar stripper and 10 ft of packing (optimum). The DCC can work effectively with a solvent with a high heat of absorption and thermal stability.

Suresh Babu, Athreya↗

Modular high temperature gas reactor core modeling with RELAP5-3D/PHISICS – Optimization schemes for load following

The objective of this study is to develop a 3D/NK model to study the load following operation of a Modular High-Temperature Gas-Cooled Reactor (MHTGR). The selected design is the 350 MW prismatic, graphite moderated, helium cooled thermal reactor based on the MHTGR-350 transient benchmark led by the High-Temperature Gas-Cooled Reactor (HTGR) Methods Core Simulation Group at Idaho National Laboratory (INL) in the framework of the Organization for Economic Cooperation and Development Nuclear Energy Agency (OECD/NEA). This kind of reactor usually reacts very slowly to the perturbation of the core parameters due to the large amount of graphite in the core. This kind of behavior promotes the reactor stability but on the other hand limits the reactor load-following operability. Recently advances in gas reactor designs have made load-following in gas reactors a feasible and achievable goal. Modern nuclear reactors (such as the MHTGR-350) are designed to withstand the structural stresses associated with load-following. Operating the reactor in load-following mode will inevitably reduce the load factor. Although a higher load factor means more revenue and the best usage of the fuel, following the variable energy demand will increase the maximum achievable fraction of generated nuclear power, being no more limited to the base load power generation. In general, if low impact on material aging and the safe operability are demonstrated the plant economics will be minimally affected. In order to ensure that the system can be safely operated in a load-following mode an extensively study has been carried out. Some tests with linear coolant mass flow rate change demonstrated that the reactor behavior is suitable for operation in load following mode. This assumption has been confirmed by a 4 days load following transient test in which the reactor supplied the requested power with a negligible error.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cryogenic thermal modeling of microwave high density signaling

Superconducting quantum computers require microwave control lines running from room temperature to the mixing chamber of a dilution refrigerator. Adding more lines without preliminary thermal modeling to make predictions risks overwhelming the cooling power at each thermal stage. In this paper, we investigate the thermal load of SC-086/50-SCN-CN semi-rigid coaxial cable, which is commonly used for the control and readout lines of a superconducting quantum computer, as we increase the number of lines to a quantum processor. We investigate the makeup of the coaxial cables, verify the materials and dimensions, and experimentally measure the total thermal conductivity of a single cable as a function of the temperature from cryogenic to room temperature values. We also measure the cryogenic DC electrical resistance of the inner conductor as a function of temperature, allowing for the calculation of active thermal loads due to Ohmic heating. Fitting this data produces a numerical thermal conductivity function used to calculate the static heat loads due to thermal transfer within the wires resulting from a temperature gradient. The resistivity data is used to calculate active heat loads, and we use these fits in a cryogenic model of a superconducting quantum processor in a typical Bluefors XLD1000-SL dilution refrigerator, investigating how the thermal load increases with processor sizes ranging from 100 to 225 qubits. We conclude that the theoretical upper limit of the described architecture is approximately 200 qubits. However, including an engineering margin in the cooling power and the available space for microwave readout circuitry at the mixing chamber, the practical limit is approximately 140 qubits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗