Search NASA⌕ Search

SEARCH · Search NASA

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Density split statistics: Cosmological constraints from counts and lensing in cells in DES Y1 and SDSS data

Here, we derive cosmological constraints from the probability distribution function (PDF) of evolved large-scale matter density fluctuations. We do this by splitting lines of sight by density based on their count of tracer galaxies, and by measuring both gravitational shear around and counts-in-cells in overdense and underdense lines of sight, in Dark Energy Survey (DES) First Year and Sloan Digital Sky Survey (SDSS) data. Our analysis uses a perturbation theory model and is validated using N-body simulation realizations and log-normal mocks. It allows us to constrain cosmology, bias and stochasticity of galaxies with respect to matter density and, in addition, the skewness of the matter density field. From a Bayesian model comparison, we find that the data weakly prefer a connection of galaxies and matter that is stochastic beyond Poisson fluctuations on ≤ 20 arcmin angular smoothing scale. The two stochasticity models we fit yield DES constraints on the matter density Ω m = 0.26 +0.04 –0.03 and Ω m = 0.28 +0.05 –0.04 that are consistent with each other. These values also agree with the DES analysis of galaxy and shear two-point functions (3x2pt, DES Collaboration et al.) that only uses second moments of the PDF. Constraints on σ8 are model dependent (σ 8 = 0.97 +0.07 –0.06 and 0.80 +0.06 –0.07 for the two stochasticity models), but consistent with each other and with the 3 x 2pt results if stochasticity is at the low end of the posterior range. As an additional test of gravity, counts and lensing in cells allow to compare the skewness S 3 of the matter density PDF to its ΛCDM prediction. We find no evidence of excess skewness in any model or data set, with better than 25 per cent relative precision in the skewness estimate from DES alone.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THE INNER GALACTIC BULGE: EVIDENCE FOR A NUCLEAR BAR?

Recent data from the VVV survey have strengthened evidence for a structural change in the Galactic bulge inward of |l| {<=} 4 Degree-Sign . Here we show with an N-body barred galaxy simulation that a boxy bulge formed through the bar and buckling instabilities effortlessly matches measured bulge longitude profiles for red clump stars. The same simulation snapshot was earlier used to clarify the apparent boxy bulge-long bar dichotomy, for the same orientation and scaling. The change in the slope of the model longitude profiles in the inner few degrees is caused by a transition from highly elongated to more nearly axisymmetric isodensity contours in the inner boxy bulge. This transition is confined to a few degrees from the Galactic plane; thus the change of slope is predicted to disappear at higher Galactic latitudes. We also show that the nuclear star count map derived from this simulation snapshot displays a longitudinal asymmetry similar to that observed in the Two Micron All Sky Survey (2MASS) data, but is less flattened to the Galactic plane than the 2MASS map. These results support the interpretation that the Galactic bulge originated from disk evolution and question the evidence advanced from star count data for the existence of a secondary nuclear bar in the Milky Way.

79 ASTRONOMY AND ASTROPHYSICS↗

SAD phasing of XFEL data depends critically on the error model

A nonlinear least-squares method for refining a parametric expression describing the estimated errors of reflection intensities in serial crystallographic (SX) data is presented. This approach, which is similar to that used in the rotation method of crystallographic data collection at synchrotrons, propagates error estimates from photon-counting statistics to the merged data. Here, it is demonstrated that the application of this approach to SX data provides better SAD phasing ability, enabling the autobuilding of a protein structure that had previously failed to be built. Estimating the error in the merged reflection intensities requires the understanding and propagation of all of the sources of error arising from the measurements. One type of error, which is well understood, is the counting error introduced when the detector counts X-ray photons. Thus, if other types of random errors (such as readout noise) as well as uncertainties in systematic corrections (such as from X-ray attenuation) are completely understood, they can be propagated along with the counting error, as appropriate. In practice, most software packages propagate as much error as they know how to model and then include error-adjustment terms that scale the error estimates until they explain the variance among the measurements. If this is performed carefully, then during SAD phasing likelihood-based approaches can make optimal use of these error estimates, increasing the chance of a successful structure solution. In serial crystallography, SAD phasing has remained challenging, with the few examples of de novo protein structure solution each requiring many thousands of diffraction patterns. Here, the effects of different methods of treating the error estimates are estimated and it is shown that using a parametric approach that includes terms proportional to the known experimental uncertainty, the reflection intensity and the squared reflection intensity to improve the error estimates can allow SAD phasing even from weak zinc anomalous signal.

59 BASIC BIOLOGICAL SCIENCES↗

Cosmological constraints from DES Y1 cluster abundances and SPT multiwavelength data

We perform a joint analysis of the counts of redMaPPer clusters selected from the Dark Energy Survey (DES) year 1 data and multiwavelength follow-up data collected within the 2500 deg2 South Pole Telescope (SPT) Sunyaev-Zel’dovich (SZ) survey. The SPT follow-up data, calibrating the richness-mass relation of the optically selected redMaPPer catalog, enable the cosmological exploitation of the DES cluster abundance data. To explore possible systematics related to the modeling of projection effects, we consider two calibrations of the observational scatter on richness estimates: a simple Gaussian model which account only for the background contamination (BKG), and a model which further includes contamination and incompleteness due to projection effects (PRJ). Assuming either a ΛCDM+∑mν or wCDM+∑mν cosmology, and for both scatter models, we derive cosmological constraints consistent with multiple cosmological probes of the low and high redshift Universe, and in particular with the SPT cluster abundance data. This result demonstrates that the DES Y1 and SPT cluster counts provide consistent cosmological constraints, if the same mass calibration data set is adopted. It thus supports the conclusion of the DES Y1 cluster cosmology analysis which interprets the tension observed with other cosmological probes in terms of systematics affecting the stacked weak lensing analysis of optically selected low–richness clusters. Finally, we analyze the first combined optically SZ selected cluster catalog obtained by including the SPT sample above the maximum redshift probed by the DES Y1 redMaPPer sample (z=0.65). Besides providing a mild improvement of the cosmological constraints, this data combination serves as a stricter test of our scatter models: the PRJ model, providing scaling relations consistent between the two abundance and multiwavelength follow-up data, is favored over the BKG model.

79 ASTRONOMY AND ASTROPHYSICS↗

Author Correction: US oil and gas system emissions from nearly one million aerial site measurements

Correction to: Naturehttps://doi.org/10.1038/s41586-024-07117-5 Published online 13 March 2024 In the version of the article initially published, several errors were present and have been corrected in the HTML and PDF versions of the article and Supplementary Information. The main results, conclusions, and our interpretations of the data remain unchanged. See the new Supplementary Information Section S15 for a more detailed description of the errors corrected and the resulting effects on the analysis. Data processing and methods corrections Overflight count correction: We previously used pre-computed source coverage data for some Carbon Mapper campaigns that was computed differently than was required for our analysis. We have re-computed Carbon Mapper source coverage based on flightline polygons and source coordinates. Transition point computation, well sites: The updated version now correctly compares the cumulative emissions distribution of simulated well site emissions with that of aerially detected sources (rather than plumes) when computing the transition point. Transition point computation, midstream: Additionally, the transition point calculation has been corrected to exclude aerially detected midstream emissions below the transition point, which was previously leading to double counting of these emissions. This error was not present for upstream (well site) emissions. Calculation errors Unit error: We corrected a specific unit conversion error affecting well site emissions in the Kairos Fort Worth dataset. Across all datasets, we also correct the conversion factor for converting from standard volume to mass for midstream emissions. Sorting error: We correct code that was applying incorrect sorting when computing correction factors to account for partial detection at well sites. Small typographical corrections were made in Fig. 1b and SI Section S4.1. Data processing and methods corrections Overflight count correction: We previously used pre-computed source coverage data for some Carbon Mapper campaigns that was computed differently than was required for our analysis. We have re-computed Carbon Mapper source coverage based on flightline polygons and source coordinates. Transition point computation, well sites: The updated version now correctly compares the cumulative emissions distribution of simulated well site emissions with that of aerially detected sources (rather than plumes) when computing the transition point. Transition point computation, midstream: Additionally, the transition point calculation has been corrected to exclude aerially detected midstream emissions below the transition point, which was previously leading to double counting of these emissions. This error was not present for upstream (well site) emissions. Calculation errors Unit error: We corrected a specific unit conversion error affecting well site emissions in the Kairos Fort Worth dataset. Across all datasets, we also correct the conversion factor for converting from standard volume to mass for midstream emissions. Sorting error: We correct code that was applying incorrect sorting when computing correction factors to account for partial detection at well sites. Small typographical corrections were made in Fig. 1b and SI Section S4.1. The following practices may help researchers conducting similar analyses avoid making similar errors: 1, Clear, accessible documentation explaining the interpretation of all columns in data input tables and all internal variables within the model, 2, Simple cross-check calculations computed before and after unit conversions.

Sherwin, Evan D↗

Experimental results from an X-ray imaging crystal spectrometer utilizing multi-wire proportional counter for KSTAR

The inconsistency of the first experimental results from the X-ray imaging crystal spectrometer for the Korea Superconducting Tokamak Advanced Research device utilizing a multi-wire proportional counter (MWPC) is clarified after improving the photon-count rate of the data acquisition system for the MWPC and ground loop isolator for the whole spectrometer system. The improved MWPC is successfully applied to pure Ohmic plasmas as well as plasmas with high confinement modes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomaly Detection in Radiation Sensor Data with Applications to Transportation Security

In this paper, we present a new approach for detecting trucks transporting illicit radioactive materials using radiation data. The approach is motivated by the high number of false alarms that typically results when using radiation portal monitors. Our approach is a three-stage anomaly detection process that consists of transforming the radiation sensor data into wavelet coefficients, representing the transformed data in binary form, and detecting anomalies among data sets using a proximity-based method. The approach is evaluated using simulated radiation data, and the results are encouraging. From a transportation security perspective, our results indicate that the concomitant use of gross count and spectroscopy radiation data improves identification of trucks transporting illicit radioactive materials. The results also suggest that the use of additional heterogeneous data with radiation data may enhance the reliability of the detection process. Further testing with real radiation data and mixture of cargo is needed to fully validate the results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A new algorithm for estimating radioxenon concentrations

A new algorithm (Xcounts) is introduced for estimating the activity concentrations of the xenon isotopes 131m Xe, 133m Xe, 133 Xe, and 135 Xe using beta-gamma coincidence data. The algorithm simultaneously estimates the decay counts associated with the four xenon isotopes, background, and radon in contrast to the net-counts method that uses sequential residual removal to account for background and interreferences. Calibration data for background counts are determined from gas-background measurements and simulation. In Xcounts, the false positive count rates for 131m Xe and 133m Xe are lower than the false positive rates for 133 Xe and 135 Xe. This algorithm appears to reliably detect the metastable isotopes at lower activity levels than the net-counts method and have similar performance for the other isotopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The coincidence counting technique for orders of magnitude background reduction in data obtained with the magnetic recoil spectrometer at OMEGA and the NIF

A magnetic recoil spectrometer (MRS) has been built and successfully used at OMEGA for measurements of down-scattered neutrons (DS-n), from which an areal density in both warm-capsule and cryogenic-DT implosions have been inferred. Another MRS is currently being commissioned on the National Ignition Facility (NIF) for diagnosing low-yield tritium-hydrogen-deuterium implosions and high-yield DT implosions. As CR-39 detectors are used in the MRS, the principal sources of background are neutron-induced tracks and intrinsic tracks (defects in the CR-39). The coincidence counting technique was developed to reduce these types of background tracks to the required level for the DS-n measurements at OMEGA and the NIF. Using this technique, it has been demonstrated that the number of background tracks is reduced by a couple of orders of magnitude, which exceeds the requirement for the DS-n measurements at both facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a four-element Si drift detector for X-ray absorption fine-structure spectroscopy: resolution, maximum count rate, and dead-time correction with incorporation into the ATHENA data analysis software

The performance of a four-element Si drift detector for energy-dispersive fluorescence-yield X-ray absorption fine-structure measurements is reported, operating at the National Institute of Standards and Technology beamline X23A2 at the National Synchrotron Light Source. The detector can acquire X-ray absorption fine-structure spectra with a throughput exceeding 4 x 10{sup 5} counts per second per detector element (>1.6 x 10{sup 6} total counts per second summed over all four channels). At this count rate the resolution at 6 keV is approximately 220 eV, which adequately resolves the Mn K{sub {alpha}} and K{sup {beta}} fluorescence lines. Accurate dead-time correction is demonstrated, and it has been incorporated into the ATHENA data analysis program. To maintain counting efficiency and high signal to background, it is suggested that the incoming count rate should not exceed {approx}70% of the maximum throughput.

42 ENGINEERING↗

TU-EF-204-04: Feasibility Study of a Novel Stationary Spectral CT Scanner

Purpose: To evaluate a cadmium zinc telluride (CZT) detector module and to develop a proof-of-concept bench-top system to examine the concept and feasibility of a stationary spectral scanner that would consist of a CZT detector ring and a distributed source for rotationless imaging. Methods: The bench-top system employs a double-rotation set-up with two concentric but independent rotating stages, one for turning the object at sparse angles to mimic the imaging from a sequentially activated source distributed on a ring, while the other for translating the detector module to simulate a projection arc along a virtual detector ring. A source of 30-degree fan is used in the set-up, and the ring is designed to be 85cm in diameter in order to provide a 22cm field-of-view that is large enough for an average human head. The CZT detector module has 16×16 0.5mm pixels and eight global energy thresholds, and is attached to an experimental data acquisition board from the same vendor (Nova R&D). Its pixel gain is first calibrated using radioisotope Tc-99m to align the photo-peaks. Count rate performance is assessed using the X-ray source. Air and offset corrections are done prior to each CT scan. A 10cm acrylic phantom with 5 different inserts is imaged at 100kVp, 2mA, with an effective exposure window of 150ms per projection. Reconstruction is done using a total variation-type iterative method. Results: The detector module exhibited large gain variations among pixels. Average count rate was over 1Mcps per pixel. Parallax effect was observed along the arcs but was corrected. Reconstructed images from two energy bins demonstrated good contrast, spatial resolution and image uniformity, with little artifacts. Conclusion: The CZT detector tested is suitable for imaging relatively small objects. A stationary spectral CT appears feasible should we have enough buttable modules and a distributed source. This work was supported by Ministry of Science and Technology of China through grants 11YQ040082 and 2012BAI13B04.

60 APPLIED LIFE SCIENCES↗

First GRB detections with the AGILE Minicalorimeter

The Minicalorimeter (MCAL) onboard the AGILE satellite is a 1400 cm{sup 2} scintillation detector sensitive in the energy range 0.3-200 MeV. MCAL works both as a slave of the AGILE Silicon Tracker and as an autonomous detector for transient events (BURST mode). A dedicated onboard Burst Search logic scans BURST mode data in search of count rate increase. Peculiar characteristics of the detector are the high energy spectral coverage and a timing resolution of about 2 microseconds. Even if a trigger is not issued, BURST mode data are used to build a broad band energy spectrum (scientific ratemeters) organized in 11 bands for each of the two MCAL detection planes, with a time resolution of 1 second. After the first engineering commissioning phase, following the AGILE launch on 23rd April 2007, between 22nd June and 5th November 2007 eighteen GRBs were detected offline in the scientific ratemeters data, with a detection rate of about one per week. In this paper the capabilities of the detector will be described and an overview of the first detected GRBs will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast correlation function calculator: A high-performance pair-counting toolkit

A novel high-performance exact pair-counting toolkit called fast correlation function calculator (FCFC) is presented. With the rapid growth of modern cosmological datasets, the evaluation of correlation functions with observational and simulation catalogues has become a challenge. High-efficiency pair-counting codes are thus in great demand. We introduce different data structures and algorithms that can be used for pair-counting problems, and perform comprehensive benchmarks to identify the most efficient algorithms for real-world cosmological applications. We then describe the three levels of parallelisms used by FCFC, SIMD, OpenMP, and MPI, and run extensive tests to investigate the scalabilities. Finally, we compare the efficiency of FCFC with alternative pair-counting codes. The data structures and histogram update algorithms implemented in FCFC are shown to outperform alternative methods. FCFC does not benefit greatly from SIMD because the bottleneck of our histogram update algorithm is mainly cache latency. Nevertheless, the efficiency of FCFC scales well with the numbers of OpenMP threads and MPI processes, even though speedups may be degraded with over a few thousand threads in total. FCFC is found to be faster than most (if not all) other public pair-counting codes for modern cosmological pair-counting applications.

79 ASTRONOMY AND ASTROPHYSICS↗

Combining biomarker and virus phylogenetic models improves HIV-1 epidemiological source identification

To identify and stop active HIV transmission chains new epidemiological techniques are needed. Here, we describe the development of a multi-biomarker augmentation to phylogenetic inference of the underlying transmission history in a local population. HIV biomarkers are measurable biological quantities that have some relationship to the amount of time someone has been infected with HIV. To train our model, we used five biomarkers based on real data from serological assays, HIV sequence data, and target cell counts in longitudinally followed, untreated patients with known infection times. The biomarkers were modeled with a mixed effects framework to allow for patient specific variation and general trends, and fit to patient data using Markov Chain Monte Carlo (MCMC) methods. Subsequently, the density of the unobserved infection time conditional on observed biomarkers were obtained by integrating out the random effects from the model fit. This probabilistic information about infection times was incorporated into the likelihood function for the transmission history and phylogenetic tree reconstruction, informed by the HIV sequence data. To critically test our methodology, we developed a coalescent-based simulation framework that generates phylogenies and biomarkers given a specific or general transmission history. Testing on many epidemiological scenarios showed that biomarker augmented phylogenetics can reach 90% accuracy under idealized situations. Under realistic within-host HIV-1 evolution, involving substantial within-host diversification and frequent transmission of multiple lineages, the average accuracy was at about 50% in transmission clusters involving 5–50 hosts. Realistic biomarker data added on average 16 percentage points over using the phylogeny alone. Using more biomarkers improved the performance. Shorter temporal spacing between transmission events and increased transmission heterogeneity reduced reconstruction accuracy, but larger clusters were not harder to get right. More sequence data per infected host also improved accuracy. We show that the method is robust to incomplete sampling and that adding biomarkers improves reconstructions of real HIV-1 transmission histories. The technology presented here could allow for better prevention programs by providing data for locally informed and tailored strategies.

60 APPLIED LIFE SCIENCES↗

235 U Determination using In-Beam Delayed Neutron Counting Technique at the NRU Reactor

This paper describes a collaborative effort that saw the Royal Military College of Canada (RMC)’s delayed neutron and gamma counting apparatus transported to Canadian Nuclear Laboratories (CNL) for use in the neutron beamline at the National Research Universal (NRU) reactor. Samples containing mg quantities of fissile material were re-interrogated, and their delayed neutron emissions measured. This collaboration offers significant advantages to previous delayed neutron research at both CNL and RMC. This paper details the determination of 235 U content in enriched uranium via the assay of in-beam delayed neutron magnitudes and temporal behavior. 235 U mass was determined with an average absolute error of ± 2.7 %. This error is lower than that obtained at RMCC for the assay of 235 U content in aqueous solutions (3.6 %) using delayed neutron counting. Delayed neutron counting has been demonstrated to be a rapid, accurate, and precise method for special nuclear material detection and identification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lessons learned on the presentation of scan data

Technicians performed a radiological survey of a surplus metal tank to support disposition planning at an Oak Ridge, Tennessee site. The survey included radiation scans to identify contamination and, if identified, define the boundary and magnitude of contamination. Fixed-point 1-minute measurements were also collected at randomly selected locations for comparison against the site's free release limit of 5,000 disintegrations per minute per 100 cm² (dpm/100 cm²) (0.83 Bq/cm²). Scan data were recorded using a data logger as a means to document surveyor observation - logged data captured at 1-second intervals and converted to counts per minute (cpm) by the data logger software were presented in the project report. Both the qualitative scan data (in cpm) and the quantitative direct measurement (in dpm/100 cm²) were reported for completeness, so stakeholders had all available information to support disposition decisions. However, a new stakeholder - introduced to the project at the reporting phase of work - used the instrument efficiency and background data to convert the scan data from cpm to dpm/100 cm², then compared the converted results to the site limit. Many of the converted values exceeded 5,000 dpm/100 cm². This resulted in delays in tank disposition and additional project costs which could have been avoided if the proper use and interpretation of scan data, and implications of radon progeny buildup on oxidized metal surfaces, had been better communicated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Expanding Lorentz and spectrum corrections to large volumes of reciprocal space for single-crystal time-of-flight neutron diffraction

Evidence is mounting that potentially exploitable properties of technologically and chemically interesting crystalline materials are often attributable to local structure effects, which can be observed as modulated diffuse scattering (mDS) next to Bragg diffraction (BD). BD forms a regular sparse grid of intense discrete points in reciprocal space. Traditionally, the intensity of each Bragg peak is extracted by integration of each individual reflection first, followed by application of the required corrections. In contrast, mDS is weak and covers expansive volumes of reciprocal space close to, or between, Bragg reflections. For a representative measurement of the diffuse scattering, multiple sample orientations are generally required, where many points in reciprocal space are measured multiple times and the resulting data are combined. The common post-integration data reduction method is not optimal with regard to counting statistics. A general and inclusive data processing method is needed. In this contribution, a comprehensive data analysis approach is introduced to correct and merge the full volume of scattering data in a single step, while correctly accounting for the statistical weight of the individual measurements. Development of this new approach required the exploration of a data treatment and correction protocol that includes the entire collected reciprocal space volume, using neutron time-of-flight or wavelength-resolved data collected at TOPAZ at the Spallation Neutron Source at Oak Ridge National Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗