Search NASA⌕ Search

SEARCH · Search NASA

Results for “cyber attacks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A critical review of cyber-physical security for building automation systems

Modern Building Automation Systems (BASs), as the brain that enable the smartness of a smart building, often require increased connectivity both among system components as well as with outside entities, such as the cloud, to enable low-cost remote management, optimized automation via outsourced cloud analytics, and increased building-grid integrations. As smart buildings move towards open communication technologies, providing access to BASs through the building's intranet, or even remotely through the Internet, has become a common practice. However, increased connectivity and accessibility come with increased cyber security threats. BASs were historically developed as closed environments with limited cyber-security considerations. As a result, BASs in many buildings are vulnerable to cyber-attacks that may cause adverse consequences, such as occupant discomfort, excessive energy usage, and unexpected equipment downtime. Therefore, there is a strong need to advance the state-of-the-art in cyber-physical security for BASs and provide practical solutions for attack mitigation in buildings. However, an inclusive and systematic review of BAS vulnerabilities, potential cyber-attacks with impact assessment, detection & defense approaches, and cyber resilient control strategies is currently lacking in the literature. This review paper fills the gap by providing a comprehensive up-to-date review of cyber-physical security for BASs at three levels in commercial buildings: management level, automation level, and field level. The general BASs vulnerabilities and protocol-specific vulnerabilities for the four dominant BAS protocols (i.e., BACnet, KNX, LonWorks, and Modbus) are reviewed, followed by a discussion on four attack targets and seven potential attack scenarios. Furthermore, the impact of cyber-attacks on BASs is summarized as signal corruption, signal delaying, and signal blocking. The typical cyber-attack detection and defense approaches are identified at the three levels. Cyber resilient control strategies for BASs under attack are categorized into passive and active resilient control schemes. Open challenges and future opportunities are finally discussed.

97 MATHEMATICS AND COMPUTING↗

Distributed Detection of Malicious Attacks on Consensus Algorithms with Applications in Power Networks

Consensus-based distributed algorithms are well suited for coordination among agents in a cyber-physical system. These distributed schemes, however, suffer from their vulnerability to cyber attacks that are aimed at manipulating data and control ow. In this article, we present a novel distributed method for detecting the presence of such intrusions for a distributed multi-agent system following ratio consensus. We employ a Max-Min protocol to develop low cost, easy to implement detection strategies where each participating node detects the intrusion independently, eliminating the need for a trusted certifying agent in the network. The effectiveness of the detection method is demonstrated by numerical simulations on a 1000 node network to demonstrate the efficacy and simplicity of implementation.

27 ARPA - Advanced Research Projects Agency-Energy↗

R&D100 Finalist: Neuromorphic Cyber Microscope

The Neuromorphic Cyber Microscope provides security analysts with unprecedented visibility of their network, computer and storage assets. This processor is the world's first practical implementation of neuromorphic technology to a major computer science mission. Working with Lewis Rhodes Labs, engineers at Sandia National Laboratories have created a device that is orders of magnitude faster at analyzing data to identify cyber-attacks.

97 MATHEMATICS AND COMPUTING↗

Protecting drinking water utilities from cyberthreats

Cyber-security challenges have the potential for becoming one of the defining issues of our time. Cyber-attacks have become an ever-increasing threat and the United States (US) Federal Bureau of Investigation (FBI) now ranks cyber-crime as one of its most important law enforcement activities. In addition to the general problems associated with cyber-crime, critical infrastructure (CI) related to energy production, manufacturing, water supply and other systems have come under attack. For example, drinking water utilities are increasingly incorporating computer technology into their routine operations and are therefore increasingly vulnerable to cyber- threats. Systems control and data acquisition (SCADA) systems used to manage automated physical processes essential to water treatment and distribution systems have become standard in medium to large drinking water utilities and in many small water systems. However, even with the application of standard information technology cybersecurity best practices these types of systems have proven to be vulnerable to cyber-attacks. In 2015, the US Department of Homeland Security (DHS) responded to 25 cybersecurity incidents in the Water Sector and to 46 incidents in the Energy Sector. Comparatively, between 2014 and 2015, the reported number of Water Sector incidents actually increased by 78.6% (from 14 to 25). The DHS is in a collaborative partnership with the US Environmental Protection Agency to ensure cybersecurity in the Water Sector. As a result of this partnership a number of guidance documents and techniques have been developed to counter cyber-attacks and minimize cyber vulnerability. These approaches are documented along with a summary of common vulnerabilities. However, a new approach which has great promise in protecting drinking water systems against hacking and cyber-attacks, based on the concept of unidirectional gateways, is presented and discussed.

99 GENERAL AND MISCELLANEOUS↗

Potential Cybersecurity Issues of Fast Charging Stations with Quantitative Severity Analysis

Potential issues of front-end converters of wireless power transfer system modules for extreme fast charging are discussed and analyzed in this study in order to provide some recommendations to defend against attacks on electric vehicles and charging systems. Compared to conventional low-power charging systems, the impact of a cyber-attack might be more detrimental in high-power / fast charging systems since the fault energy levels would be inherently higher both on the grid- and vehicle- side converters. In order to analyze the potential issues that might be a result of cyber-attacks, the negative scenarios are reviewed in this study which include interfering with the grid-side controllers, establishing fake communications between the vehicles and the charging stations, and interfering with the battery management system functionalities. A 100-kW stationary wireless power transfer system with a series-series resonant compensation network is used as a representative system in the analysis. Potential damages and the fault energy levels for selected fault scenarios are investigated. The system is simulated to verify the analysis results. On the basis of the discussed worst-case study, a set of hardware design-level solutions are recommended in this study to provide cyber protection.

Park, Yongwan↗

Cybersecurity for the Operational Technology Environment (CyOTE) (Final Technical Report)

Electric grids have historically been susceptible to both physical attacks and environmental hazards but the implementation of smart grids, remote management, and self-healing networks, has now made the grid vulnerable to cyber attacks. To address risks introduced by routable connectivity, utilities must establish dynamic solutions to identify, protect, detect, respond to, and recover from cyber security threats and vulnerabilities. In response to the evolving threat landscape U.S. Department of Energy-Office of Cybersecurity, Energy Security, and Emergency Response (DOE CESER) initiated the Cybersecurity for the OT Environment (CyOTE) pilot program, a U.S. Department of Energy (DOE) effort designed to leverage U.S. intelligence capabilities to prevent, detect, or mitigate a cyber attack on utility operational technology (OT) networks. As part of the CyOTE pilot, The Southern Company (Southern Company or Southern) researched, evaluated and deployed emerging Commercial off the Shelf (COTS) technologies and cyber security monitoring architectures to provide previously unrealized network visibility and situational awareness through deep packet inspection and data analytics. This Final Scientific/Technical Report documents the objectives, methodology, lessons learned, and results of Southern Company’s participation in the CyOTE pilot from December 2018 to September 2023.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber-Informed Engineering Implementation Guide: Version 1.0 [Slides]

This Implementation Guide describes the principles of Cyber-Informed Engineering (CIE) and outlines questions that engineering teams should consider during each phase of a system's lifecycle to effectively employ these principles. It describes what it means to engineer systems in a cyber-informed way, rather than offering a comprehensive, step-by-step process or procedure for CIE implementation. This guide complements - but does not replace - the application of cybersecurity standards or practices currently in place within an organization. Engineers and technicians that design critical energy infrastructure installations can use this Implementation Guide to integrate the 12 principles of CIE into each phase of the engineering lifecycle, from concept to retirement. The guide is aimed at system or design engineers, rather than software engineers or operational cybersecurity practitioners. The engineers who design, build, operate, and maintain the physical infrastructure are best positioned to leverage a system's engineering design to diminish the severity of cyber attacks or digital technology failures. CIE expands cybersecurity decisions into the engineering space, not by asking engineers to become cyber experts, but by calling on engineers to apply engineering tools and make engineering decisions that improve cybersecurity outcomes. CIE examines the engineering consequences that a sophisticated cyber attacker could achieve and drives engineering changes that may provide deterministic mitigations to limit or eliminate those consequences.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber-Informed Engineering Implementation Guide

This Implementation Guide describes the principles of Cyber-Informed Engineering (CIE) and outlines questions that engineering teams should consider during each phase of a system’s lifecycle to effectively employ these principles. It describes what it means to engineer systems in a cyber-informed way, rather than offering a comprehensive, step-by-step process or procedure for CIE implementation. This guide complements—but does not replace—the application of cybersecurity standards or practices currently in place within an organization. Engineers and technicians that design critical energy infrastructure installations can use this Implementation Guide to integrate the 12 principles of CIE into each phase of the engineering lifecycle, from concept to retirement. The guide is aimed at system or design engineers, rather than software engineers or operational cybersecurity practitioners. The engineers who design, build, operate, and maintain the physical infrastructure are best positioned to leverage a system’s engineering design to diminish the severity of cyber attacks or digital technology failures. CIE expands cybersecurity decisions into the engineering space, not by asking engineers to become cyber experts, but by calling on engineers to apply engineering tools and make engineering decisions that improve cybersecurity outcomes. CIE examines the engineering consequences that a sophisticated cyber attacker could achieve and drives engineering changes that may provide deterministic mitigations to limit or eliminate those consequences.

42 ENGINEERING↗

Cybersecurity Assessment in DER-rich Distribution Operations: Criticality Levels and Impact Analysis

The integration of distributed energy resources (DERs) in distribution networks has become a pivotal strategy for achieving decarbonization, enhancing grid resilience, and optimizing grid efficiency. Remote monitoring and control op- erations of such resources rely on a network of sensors and communication infrastructure, exposing the system to potential cyber threats. Therefore, as the deployment of DERs increases, ensuring secure monitoring and control becomes an imperative challenge. This paper utilizes real-time feeder models, which are instrumental in developing cybersecurity testbeds tailored for hardware-in-loop (HIL) systems. These models enable users to simulate cyber attacks in a real-world environment and analyze the power distribution operations during vulnerabilities. Furthermore, we discuss several practical sets of grid parameters to identify critical levels of DERs and evaluate various scenarios that simulate cyber threats on sensitive DERs. The modified IEEE 123-bus model is used as the test case for demonstrating the proposed scenarios. The findings from this study provide valuable insights into the vulnerabilities and potential consequences of cyber attacks on DERs, allowing for better mitigation strategies and improved cyber resilience in future distribution networks.

Maharjan, Manisha↗

SDN-Based Dynamic Cybersecurity Framework of IEC-61850 Communications in Smart Grid

In recent years, critical infrastructure and power grids have experienced a series of cyber-attacks, leading to temporary, widespread blackouts of considerable magnitude. Since most substations are unmanned and have limited physical security protection, cyber breaches into power grid substations present a risk. Nowadays, the susceptibility of SDN architecture to cyber-attacks has exhibited a notable increase in recent years, as indicated by research findings. This suggests a growing concern regarding the potential for cybersecurity breaches within the SDN framework. In this paper, we propose a hybrid intrusion detection system (IDS)-integrated SDN architecture for detecting and preventing the injection of malicious IEC 61850-based generic object-oriented system event (GOOSE) messages in a digital substation. Additionally, this program locates the fault’s location and, as a form of mitigation, disables a certain port. Furthermore, implementation examples are demonstrated and verified using a hardware-in-the-loop (HIL) testbed that mimics the functioning of a digital substation.

Liu, Chen-Ching [Virginia Tech] (ORCID:00000002894↗

A Testbed Environment for Buildings-to-Grid Cyber Resilience Research and Development

The Smart Grid is characterized by the proliferation of advanced digital controllers at all levels of its operational hierarchy from generation to end consumption. Such controllers within modern residential and commercial buildings enable grid operators to exercise fine-grained control over energy consumption through several emerging Buildings-to-Grid (B2G) applications. Though this capability promises significant benefits in terms of operational economics and improved reliability, cybersecurity weaknesses in the supporting infrastructure could be exploited to cause a detrimental effect and this necessitates focused research efforts on two fronts. First, the understanding of how cyber attacks in the B2G space could impact grid reliability and to what extent. Second, the development and validation of cyber-physical application-specific countermeasures that are complementary to traditional infrastructure cybersecurity mechanisms for enhanced cyber attack detection and mitigation. The PNNL B2G testbed is currently being developed to address these core research needs. Specifically, the B2G testbed combines high-fidelity buildings+grid simulators, industry-grade building automation and Supervisory Control and Data Acquisition (SCADA) systems in an integrated, realistic, and reconfigurable environment capable of supporting attack-impact-detection-mitigation experimentation. In this paper, we articulate the need for research testbeds to model various B2G applications broadly by looking at the end-to-end operational hierarchy of the Smart Grid. Finally, the paper not only describes the architecture of the B2G testbed in detail, but also addresses the broad spectrum of B2G resilience research it is capable of supporting based on the smart grid operational hierarchy identified earlier.

Sridhar, Siddharth↗

Cyber-informed Engineering Microgrid Analysis Tool

The Cyber-Informed Engineering Microgrid Analysis Tool (CIEMAT) leverages the Department of Energy’s Cyber-Informed Engineering to prompt engineering designers and operators through an analysis of the critical functions to be supported by a microgrid installations, the criticality of those functions, the impacts of denial, disruption or misuse of those functions on the microgrid and dependent functions, and the mitigations which could best prevent impacts to those functions resulting from cyber attack. Through use of this tool, microgrid designers and operators can quickly identify appropriate engineering mitigations to limit impacts from cyber attack and functions where engineering and operational staff can prioritize and guide the application of cybersecurity protections to best support the resiliency of the system.

Wright, VirginiaL [Idaho National Laboratory (INL)↗

Cyber threat assessment of machine learning driven autonomous control systems of nuclear power plants

We report advanced cyber-attacks against critical infrastructure and the energy sector are becoming more common. With the invention of autonomous control systems (ACS) within advanced nuclear reactor designs, system designers, reactor operators, and regulators must consider cybersecurity during the design and operational phases. This article provides a cyber threat assessment of machine learning (ML)-based digital twinning (DT) technologies in the context of advanced reactor ACS. A cyber–physical testbed was created to emulate nuclear reactor digital instrumentation and controls (I&C) and act as a basis for the ACS. The ACS was designed as two plant-level DTs predicting reactor malfunctions and determining control actions and two component-level DTs responsible for classifying component states and forecasting component inputs and outputs (I/O). Two duplicate ACS designs– one using a traditional ML framework and one using an automated ML (AutoML) framework– were created and tested against cyber-attacks on training data, real-time process data, and ML model architectures to determine their respective qualitative cyber-risk in terms of likelihood and impact. Both frameworks showed similar cyber-resilience against training, real-time, and ML architecture attacks, proving that neither is inherently more secure. Recommended safeguard and security measures are posed to system designers, reactor operators, and regulators to maintain the cybersecurity of ML-based DT technologies such as ACS, prompting a holistic view of shared responsibility for maintaining cyber-secure ML-based systems.

99 GENERAL AND MISCELLANEOUS↗

Risk-Averse Bi-Level Stochastic Network Interdiction Model for Cyber-Security Risk Management

Security of cyber networks is crucial; recent severe cyber-attacks have had a devastating effect on many large organizations. The attack graph, which maps the potential attack paths of a cyber network, is a popular tool for analyzing cyber system vulnerability. In this study, we propose a bi-level stochastic network interdiction model on an attack graph to enable a risk-averse, resource constrained cyber network defender to optimally deploy security countermeasures that protect against attackers with an uncertain budget. This risk- averse conditional-value-at-risk (CVaR) model minimizes a weighted sum of the expected maximum loss over all scenarios and the expected maximum loss from the most damaging attack scenarios. We develop a customized constraint and column generation algorithm to solve our model as well as several acceleration techniques to improve the computational efficiency. Numerical experiments demonstrate that the acceleration techniques enable the solution of relatively large problems within a reasonable amount of time: applying all the acceleration techniques also reduces the average computation time of the basic algorithm by 71% for 100-node graphs. Using metrics called mean-risk value of stochastic solution and value of risk-aversion, computational results suggest that our stochastic risk-averse model significantly outperforms deterministic and risk-neutral models when 1) the distribution of attacker budget is heavy-right-tailed and 2) the defender is highly risk-averse.

Bhuiyan, Tanveer H.↗

Machine Learning-based Cyber-Physical Anomaly Detection in Wide Area Voltage Control Systems

Wide-area voltage control systems (WAVCS) are widely deployed in power grid to improve the voltage stability in transmission system using Flexible AC Transmission System (FACTS) devices. The WAVCS relies on wide-area measurement and control signals for closed-loop control of FACTS devices to improve the transient voltage stability in power grid in real-time. Since the WAVCS utilizes a cyber-layer communication during its normal operation, they are susceptible to cyber attacks from adversaries which can lead to a voltage collapse if the attacks go undetected and unmitigated. This paper proposes a supervised machine learning (ML)-based anomaly detection algorithm for detecting various stealthy cyber attacks in the context of WAVCS cybersecurity. In particular, a fuzzy logic-based wide-area controller, as proposed by the Bonneville Power Administration (BPA), is implemented on the Kundur’s four machine two-area system that is integrated with a static var compensator (SVC) to improve voltage profile on sensitive buses. Later, different types of data integrity attacks, including pulse and ramp attacks, are considered on the wide-area measurement and control signals to analyze the performance of the proposed anomaly detector. Our experimental evaluation shows a promising performance with a high true-positive rate (more than 99%) and low false-negative rate (less than 1%) while exhibiting a small prediction time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber-informed Engineering Battery Analysis Tool

The Cyber-Informed Engineering Battery Analysis Tool (CIEBAT) leverages the Department of Energy’s Cyber-Informed Engineering to prompt engineering designers and operators through an analysis of the critical functions to be supported by a BESS installation, the criticality of those functions, the impacts of denial, disruption or misuse of those functions within the BESS system, and the mitigations which could best prevent impacts to those functions resulting from cyber attack. Through use of this tool, BESS designers and operators can quickly identify appropriate engineering mitigation opportunities to limit impacts from cyber attack and functions where engineering and operational staff can prioritize and guide the application of cybersecurity protections to best support the resiliency of the system.

Lampe, BenjaminR [Idaho National Laboratory (INL),↗

Anomaly Detection for Power System Generation Control based on Hierarchical DBSCAN

The generation level of a generator in power grid is under control of multiple control loops such as governor action, Automatic Generation Control (AGC), and manual control. These control loops are vulnerable to cyber attacks and could become potential targets for the malicious adversary. In this paper, we investigated the detection of abnormal generation controls induced by cyber attacks. One data-driven anomaly detection methodology is presented based on the behavior conformity of generation units located in the same balancing authority. A semi-supervised clustering algorithm with Hierarchical Density based Spatial Clustering of Application with Noise (HDBSCAN) is proposed for the detection model training. In our previous work, we obtained a synthetic dataset that covers scenarios including normal operation, generation control under ramp attack, switching attack, AGC integrity attacks, etc. and it is used to evaluate the proposed clustering algorithm. Experimental results show that the proposed algorithm provides better detection accuracy than K-means clustering and can distinguish not only between normal and abnormal generation controls but also among various anomaly scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multifractal Characterization of Distribution Synchrophasors for Cybersecurity Defense of Smart Grids

“Source ID Mix” spoofing emerged as a new type of cyber-attack on Distribution Synchrophasors (DS) where adversaries have the capability to swap the source information of DS without changing the measurement values. Accurate detection of such a highly-deceptive attack is a challenging task especially when the spoofing attack happens on short fragments of DS recorded within a relatively small geographical scale. Herein this letter proposes an effective approach to detect this cyber-attack by realizing the multifractal characteristics of DS measurements. First, the multifractal cross-correlation of DS measured at multiple intra-state locations is revealed. Then the derived correlation is integrated with weighted two-dimensional multifractal surface interpolation to reconstruct quasi high-resolution signals. Finally, informative location-specific signatures are extracted from the high-resolution DS and they are integrated with advanced machine learning techniques for source authentication. Experiments using the real-life DS are performed to verify the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗