Search NASA⌕ Search

SEARCH · Search NASA

Results for “data volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Assessment of interpatient heterogeneity in tumor radiosensitivity for nonsmall cell lung cancer using tumor-volume variation data

Purpose: In our previous work, the authors showed that a distribution of cell surviving fractionsS{sub 2} in a heterogeneous group of patients could be derived from tumor-volume variation curves during radiotherapy for head and neck cancer. In this research study, the authors show that this algorithm can be applied to other tumors, specifically in nonsmall cell lung cancer. This new application includes larger patient volumes and includes comparison of data sets obtained at independent institutions. Methods: Our analysis was based on two data sets of tumor-volume variation curves for heterogeneous groups of 17 patients treated for nonsmall cell lung cancer with conventional dose fractionation. The data sets were obtained previously at two independent institutions by using megavoltage computed tomography. Statistical distributions of cell surviving fractionsS{sub 2} and clearance half-lives of lethally damaged cells T{sub 1/2} have been reconstructed in each patient group by using a version of the two-level cell population model of tumor response and a simulated annealing algorithm. The reconstructed statistical distributions of the cell surviving fractions have been compared to the distributions measured using predictive assays in vitro. Results: Nonsmall cell lung cancer presents certain difficulties for modeling surviving fractions using tumor-volume variation curves because of relatively large fractional hypoxic volume, low gradient of tumor-volume response, and possible uncertainties due to breathing motion. Despite these difficulties, cell surviving fractionsS{sub 2} for nonsmall cell lung cancer derived from tumor-volume variation measured at different institutions have similar probability density functions (PDFs) with mean values of 0.30 and 0.43 and standard deviations of 0.13 and 0.18, respectively. The PDFs for cell surviving fractions S{sub 2} reconstructed from tumor volume variation agree with the PDF measured in vitro. Conclusions: The data obtained in this work, when taken together with the data obtained previously for head and neck cancer, suggests that the cell surviving fractionsS{sub 2} can be reconstructed from the tumor volume variation curves measured during radiotherapy with conventional fractionation. The proposed method can be used for treatment evaluation and adaptation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Galaxy morphological classification in deep-wide surveys via unsupervised machine learning

ABSTRACT Galaxy morphology is a fundamental quantity, which is essential not only for the full spectrum of galaxy-evolution studies, but also for a plethora of science in observational cosmology (e.g. as a prior for photometric-redshift measurements and as contextual data for transient light-curve classifications). While a rich literature exists on morphological-classification techniques, the unprecedented data volumes, coupled, in some cases, with the short cadences of forthcoming ‘Big-Data’ surveys (e.g. from the LSST), present novel challenges for this field. Large data volumes make such data sets intractable for visual inspection (even via massively distributed platforms like Galaxy Zoo), while short cadences make it difficult to employ techniques like supervised machine learning, since it may be impractical to repeatedly produce training sets on short time-scales. Unsupervised machine learning, which does not require training sets, is ideally suited to the morphological analysis of new and forthcoming surveys. Here, we employ an algorithm that performs clustering of graph representations, in order to group image patches with similar visual properties and objects constructed from those patches, like galaxies. We implement the algorithm on the Hyper-Suprime-Cam Subaru-Strategic-Program Ultra-Deep survey, to autonomously reduce the galaxy population to a small number (160) of ‘morphological clusters’, populated by galaxies with similar morphologies, which are then benchmarked using visual inspection. The morphological classifications (which we release publicly) exhibit a high level of purity, and reproduce known trends in key galaxy properties as a function of morphological type at z < 1 (e.g. stellar-mass functions, rest-frame colours, and the position of galaxies on the star-formation main sequence). Our study demonstrates the power of unsupervised machine learning in performing accurate morphological analysis, which will become indispensable in this new era of deep-wide surveys.

Martin, G.↗

SU-E-J-48: Development of An Abdominal Compression Device for Respiratory Correlated Radiation Therapy

Purpose: The aim of this study is to develop the abdominal compression device which could control pressure level according to the abdominal respiratory motion and evaluate its feasibility. Methods: In this study, we focused on developing the abdominal compression device which could control pressure level at any point of time so the developed device is possible to use a variety of purpose (gating technique or respiratory training system) while maintaining the merit of the existing commercial device. The compression device (air pad form) was designed to be able to compress the front and side of abdomen and the pressure level of the abdomen is controlled by air flow. Pressure level of abdomen (air flow) was determined using correlation data between external abdominal motion and respiratory volume signal measured by spirometer. In order to verify the feasibility of the device, it was necessary to confirm the correlation between the abdominal respiratory motion and respiratory volume signal and cooperation with respiratory training system also checked. Results: In the previous study, we could find that the correlation coefficient ratio between diaphragm and respiratory volume signal measured by spirometer was 0.95. In this study, we confirmed the correlation between the respiratory volume signal and the external abdominal motion measured by belt-transducer (correlation coefficient ratio was 0.92) and used the correlated respiratory volume data as an abdominal pressure level. It was possible to control the pressure level with negligible time delay and respiratory volume data based guiding waveforms could be properly inserted into the respiratory training system. Conclusion: Through this feasibility study, we confirmed the correlation between the respiratory volume signal and the external abdominal motion. Also initial assessment of the device and its compatibility with the respiratory training system were verified. Further study on application in respiratory gated therapy and respiratory training system will be investigated. This work was supported by Radiation Technology R and D program (No. 2013M2A2A7043498)and Basic Atomic Energy Research Institute (BAERI)(No. NRF-2009-0078390) through the National Research Foundation of Korea funded by the Ministry of Science, ICT and Future Planning.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An investigation of wing buffeting response at subsonic and transonic speeds. Phase 2: F-111A flight data analysis. Volume 3: Tabulated power spectra

Power spectral density (PSD) data for all of the flight points examined during the Phase 2 flight data analysis are presented in tabular form. Detailed descriptions of the aircraft, the flight instrumentation and the analysis techniques are given. Measured and calculated vibration mode frequencies are also presented to assist in further interpretation of the PSD data.

Benepe, D. B.↗

Data correlation and analysis of arc tunnel and wind tunnel tests of RSI joints and gaps. Volume 2: Data base

Wind tunnel tests were conducted to determine the aerodynamic heating created by gaps in the reusable surface insulation (RSI) thermal protection system (TPS) for the space shuttle. The effects of various parameters of the RSI on convective heating characteristics are described. The wind tunnel tests provided a data base for accurate assessment of gap heating. Analysis and correlation of the data provide methods for predicting heating in the RSI gaps on the space shuttle.

Christensen, H. E.↗

An investigation of wing buffeting response at subsonic and transonic speeds. Phase 1: F-111A flight data analysis. Volume 2: Plotted power spectra

Volume 2 of this three volume report is presented. This volume presents plotted variations of power spectral density data with frequency for each structural response item for each data sampled and analyzed during the course of the investigation. Some of the information contained in Volume 1 are repeated to allow the reader to identify the specific conditions appropriate to each plot presented and to interpret the data.

Benepe, D. B.↗

User data dissemination concepts for earth resources, appendixes

A number of appendices were presented, dealing with the following topics: (1) a summary of the recommendations for spectral band location from six studies and for six disciplines. (2) demonstration of the LANDSAT scenes required for a satellite of 18-day repeat cycle, and comparison of the data volume associated with scene transmission with the data volume based on length-of-swath estimates, (3) presentation of a sample of the potential user demand projected based on polar orbiter passes over Conus and Alaska, (4) presentation of the nominal and expanded user demands for both Conus and Alaska, (5) derivation of a mathematical relation, (6) tables giving cost calculations for certain data points, (7) presentation of the UOT G/T and link budgets for leased-transponder transmission alternative, and (8) flow charts of the simulation program.

Source record↗

ASCR Workshop on In Situ Data Management: Enabling Scientific Discovery from Diverse Data Sources

In January 2019, the U.S. Department of Energy, Office of Science program in Advanced Scientific Computing Research, convened a workshop to identify priority research directions for in situ data management (ISDM). The workshop defined ISDM as the practices, capabilities, and procedures to control the organization of data and enable the coordination and communication among heterogeneous tasks, executing simultaneously in a high-performance computing system, cooperating toward a common objective. The workshop revealed two primary, interdependent motivations for processing and managing data in situ. The first motivation is that the in situ methodology enables scientific discovery from a broad range of data sources over a wide scale of computing platforms: leadership-class systems, clusters, clouds, workstations, and embedded devices at the edge. The successful development of ISDM capabilities will benefit real-time decision-making, design optimization, and data-driven scientific discovery. The second motivation is the need to decrease data volumes. ISDM can make critical contributions to managing large data volumes from computations and experiments to minimize data movement, save storage space, and boost resource efficiency, often while simultaneously increasing scientific precision. A fundamental finding of this workshop is that the methodologies used to manage data among a variety of tasks in situ can be used to facilitate scientific discovery from many different data sources—simulation, experiment, and sensors, for example—and that being able to do so at numerous computing scales will benefit real-time decision-making, design optimization, and data-driven scientific discovery across the Office of Science mission space. Applications wanting to use the in situ capabilities include those where data analysis feeds back to the simulation, decisions are made autonomously, big data or machine learning is among the tasks to be coordinated, and computations need to be completed in real time. The workshop identified six priority research directions that highlight the components and capabilities needed for ISDM to be successful for the wide variety of applications discussed: making ISDM capabilities more pervasive, controllable, composable, and transparent, with a focus on greater coordination with the software stack and a diversity of fundamentally new data algorithms.

97 MATHEMATICS AND COMPUTING↗

ASCR Workshop on In Situ Data Management

In January 2019, the U.S. Department of Energy, Office of Science program in Advanced Scientific Computing Research, convened a workshop to identify priority research directions for in situ data management (ISDM). The workshop defined ISDM as the practices, capabilities, and procedures to control the organization of data and enable the coordination and communication among heterogeneous tasks, executing simultaneously in a high-performance computing system, cooperating toward a common objective. The workshop revealed two primary, interdependent motivations for processing and managing data in situ. The first motivation is that the in situ methodology enables scientific discovery from a broad range of data sources over a wide scale of computing platforms: leadership-class systems, clusters, clouds, workstations, and embedded devices at the edge. The successful development of ISDM capabilities will benefit real-time decision-making, design optimization, and data-driven scientific discovery. The second motivation is the need to decrease data volumes. ISDM can make critical contributions to managing large data volumes from computations and experiments to minimize data movement, save storage space, and boost resource efficiency, often while simultaneously increasing scientific precision.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

The effect of skin thickness determined using breast CT on mammographic dosimetry

The effect of breast skin thickness on dosimetry in mammography was investigated. Breast computed tomography (CT) acquisition techniques, combined with algorithms designed for determining specific breast metrics, were useful for estimating skin thickness. A radial-geometry edge detection scheme was implemented on coronal reconstructed breast CT (bCT) images to measure the breast skin thickness. Skin thickness of bilateral bCT volume data from 49 women and unilateral bCT volume data from 2 women (10 healthy women and 41 women with BIRADS 4 and 5 diagnoses) was robustly measured with the edge detection scheme. The mean breast skin thickness ({+-}inter-breast standard deviation) was found to be 1.45{+-}0.30 mm. Since most current published normalized glandular dose (D{sub gN}) coefficients are based on the assumption of a 4-mm breast skin thickness, the D{sub gN} values computed with Monte Carlo techniques will increase up to 18% due to the thinner skin layers (e.g., 6-cm 50% glandular breast, 28 kVp Mo-Mo spectrum). The thinner skin dimensions found in this study suggest that the current D{sub gN} values used for mammographic dosimetry lead to a slight underestimate in glandular dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Columbia: The first five flights entry heating data series. Volume 3: The lower windward surface centerline

Entry heating flight data and wind tunnel data on the lower surface centerline are presented in terms of normalized film heat transfer coefficients as a function of angle-of-attack, Mach number, and Normal Shock Reynolds number. The surface heating rates and temperatures were obtained via the JSC NONLIN/INVERSE computer program. Time history plots of the surface heating rates and temperatures are also presented.

Williams, S. D.↗

Acoustic Treatment Design Scaling Methods: Analytical and Experimental Data Correlation - Volume 5

The primary purpose of the study presented in this volume is to present the results and data analysis of in-duct transmission loss measurements. Transmission loss testing was performed on full-scale, 1/2-scale, and 115-scale treatment panel samples. The objective of the study was to compare predicted and measured transmission loss for full-scale and subscale panels in an attempt to evaluate the variations in suppression between full- and subscale panels which were ostensibly of equivalent design. Generally, the results indicated an unsatisfactory agreement between measurement and prediction, even for full-scale. This was attributable to difficulties encountered in obtaining sufficiently accurate test results, even with extraordinary care in calibrating the instrumentation and performing the test. Test difficulties precluded the ability to make measurements at frequencies high enough to be representative of subscale liners. It is concluded that transmission loss measurements without ducts and data acquisition facilities specifically designed to operate with the precision and complexity required for high subscale frequency ranges are inadequate for evaluation of subscale treatment effects.

Chien, W. E.↗