Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial building HVAC demand flexibility with model predictive control: Field demonstration and literature insights

Model Predictive Control (MPC) for building Heating Ventilation and Air Conditioning (HVAC) systems is beginning to gain traction in the market, with a few controls companies incorporating it into their product offerings. However, it remains difficult to assess whether the energy cost savings are enough to justify the cost of MPC implementation for a particular building, given the limited number of reported demonstrations. For small commercial and residential buildings with relatively uniform systems, standardized approaches can help lower implementation costs. In contrast, for large buildings or district systems, the potential magnitude of cost savings could justify more customized solutions. Estimating the cost-effectiveness of MPC becomes more challenging for medium and large commercial buildings, where a one-size-fits-all solution may not be suitable, and the potential energy cost savings may be insufficient to justify a customized solution. To make MPC technology more appealing, incorporating additional value streams beyond energy efficiency alone can significantly increase its attractiveness. One such revenue stream is demand flexibility, in response to dynamic electricity prices, where MPC can leverage the thermal mass of the building to shift the load and support the grid. Building on an extensive literature review of MPC field studies focused on cost savings and demand flexibility, this paper presents the results of implementing MPC control in a large office building HVAC system in Berkeley, CA. Four different dynamic electricity price profiles were integrated into the MPC objective function to shift building demand while maintaining comfort, and field testing was performed with each price profile across four seasons. The results show potential for 40–65 % demand decrease percentage and up to 61 % annual cost savings compared to the existing rule-based control strategy, under the tested dynamic price scenarios. This paper also presents a sensitivity analysis on the cost savings with respect to the price profile variability, discusses the implementation effort for the price-responsive MPC, and compares the cost savings found in this study to those found in literature on the basis of dynamic price variability, or so-called Electricity Price Relative Standard Deviation.

Zanetti, Ettore↗

Experimental test of model predictive control in a variable air volume system

Model predictive control (MPC) has been widely studied as a promising approach for improving energy efficiency and operational flexibility in buildings, yet its real-world performance for commercial variable air volume (VAV) systems remains insufficiently characterized. In particular, the impacts of model mismatch on control robustness, real-time computational burden, and device-level operation are rarely evaluated using long-term field data. Here, this study presents a comprehensive experimental evaluation of MPC applied to a full-scale VAV system in Oak Ridge National Laboratory’s Flexible Research Platform-2 building with constant cooling/heating temperature setpoints and no occupancy. The study offers three key advantages over existing work: (1) it uses a representative building in a full-scale experimental test, capturing realistic system dynamics and complexity; (2) it evaluates a relatively sophisticated MPC formulation using two different optimization solvers (Gurobi and PSO), fully accounting for computational complexity and methodological diversity; and (3) it systematically assesses potential negative impacts on various building devices, benchmark against a well-established baseline, ASHRAE Guideline 36 (G36). To isolate zone- and air-handling-unit–level supervisory control effects, the supply fan was operated with a fixed static pressure setpoint under all strategies, and the trim-and-response static pressure reset in G36 was not enabled. Results show that MPC maintained thermal comfort while improving energy efficiency. Abrupt solar radiation variations degraded performance. Computation times ranged from ∼1 s (Gurobi) to ∼ 70 s (PSO). Compared with G36, MPC achieves 33% energy savings and reduces median reheat coil output by approximately a factor of 5–10 for a representative cooling day under matched weather conditions. However, it increases the maximum discomfort deviation from 0.5 to 1°C and results in a 32% increase in staging frequency. In addition, PSO-based MPC introduced damper oscillations, also affecting actuator longevity.

ASHRAE guideline 36↗

Design and performance assessment of a dual-mode latent thermal storage integrated heat pump across multiple climate zones

The electrification of space cooling and heating systems risks overloading the existing electrical grid during peak hours. Heat pumps integrated with thermal energy storage (HP-TES) offer a promising solution by shifting peak loads to off-peak hours, reducing grid strains. This work presents the design and assessment of a dual-mode HP-TES that uses a single 22°C phase-change material (PCM) as a heat source or sink in heating and cooling modes, respectively. Performance assessment was conducted using Modelica-based transient models, and full-year simulations were conducted across eight US climate zones using typical weather data. Two HP-TES performance metrics: peak energy reduction and recharge energy increases, were defined by comparing HP-TES energy consumption with base HP peak consumptions. Annual heating demand reductions (40–65%) exceeded cooling demand reductions (15–20%) due to the elimination of peak-hour backup heating. Cooling mode recharge energy requirements (0–10%) were reduced in locations with lower summer nighttime temperatures, while heating recharge requirements were lower than the high base-peak energy demand from backup heating. Simplified rapid methods that were 10 7 times faster than annual simulations were developed to predict seasonal cooling and heating energy reductions, and recharge energy requirements, with maximum deviations of ±2.5% and ±3.5% points. These methods enabled rapid parametric studies that identified optimal location-specific PCM temperatures between 22°C and 27°C, highlighting the need to consider both discharge and recharge energy requirements to achieve sustainable, energy-efficient peak load shifting across various climate zones.

25 ENERGY STORAGE↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

A chemical kinetic analysis of knock propensity of methanol-to-gasoline fuel

Production of low carbon gasoline-like fuels such as methanol-to-gasoline (MTG) is a promising approach to achieve rapid greenhouse gas emission reduction of the transportation sector. Despite the fact that gasoline that meets the ASTM D4814 standard for automotive spark-ignition engine fuel can be readily produced from these processes, it is unclear how the composition of MTG may affect engine performance and emissions. Here, in this paper, a surrogate for an MTG is used to numerically study the effects of gasoline composition on knock propensity and on the sensitivity of knock to thermal and fuel stratification, to oxygen dilution and to nitric oxide from exhaust gas recirculation of residual gases. Simulations were performed in ANSYS CHEMKIN-PRO using a comprehensive chemical kinetic mechanism for gasoline surrogates, and results of the MTG surrogate were compared against those of a petroleum-based regular E10 gasoline, termed PACE-20. A premium-grade MTG fuel was also formulated by adding ethanol to the MTG surrogate, and results were compared against those of four premium-grade, gasoline-like fuels representative of future alternative gasoline formulations. Surrogates and mechanism were evaluated by comparison against experimental engine data, and the model showed high accuracy at stoichiometric conditions (mean absolute error of ignition timing equal to 1.46 crank angle degrees) but larger deviations at lean conditions (mean absolute error of ignition timing equal to 5.52 crank angle degrees). Despite the fact that the MTG surrogate has a RON 1.1 units higher than that of PACE-20, it may show higher knock propensity at medium temperature conditions due to a less intense NTC behavior. MTG autoignition was more temperature- and equivalence ratio-sensitive than that of PACE20, suggesting that MTG can benefit more from naturally-occurring thermal stratification or from induced fuel stratification of the end gas to mitigate knock intensity. The sensitivity of autoignition reactivity to oxygen dilution and to NO concentration was higher for MTG than for regular gasoline at medium loads, but the opposite trend was observed at high loads due to the effect of pressure on the low-temperature chemistry of regular gasoline. Approximately 14 % vol ethanol content was required to upgrade the octane rating of MTG from regular grade to premium grade. Adding 13.6 % vol ethanol made the fuel autoignition less sensitive to both oxygen dilution and NO content (ignition time varies approx. 17 % and 50 % less with oxygen dilution and NO addition, respectively, when adding ethanol at high engine loads).

02 PETROLEUM↗

Implementation of tritium transport in a gas-liquid contactor CFD simulation of tritium extraction from lead-lithium in ANSYS fluent

Modifications to the Computational Fluid Dynamic (CFD) software ANSYS Fluent were done to quantify and characterize tritium transport in Gas-Liquid Contactors (GLCs). A double-slit, Ergun-like equation was employed for the porous media model, with Ergun coefficients validated with Sulzer’s Sulcol software. Tritium transport from PbLi within the GLC was verified against analytical models. The geometry of the CFD model was based on the MELODIE GLC experiment. The hydrodynamic CFD pressure drop results align well with SulCol estimations and fall between the predictions of the analytical Delft-Olujic and Billet & Schultes models. In terms of mass transfer efficiency, traditional mass transfer models showed a significant deviation from experimental results when using varying values of H solubility in PbLi. A saturation phenomenon occurred when utilizing high solubility values for hydrogen in PbLi. In conclusion, a modified film theory mass transfer coefficient, incorporating either the Delft-Olujic or Billet & Schultes wettability model, yielded CFD-predicted extraction efficiencies that closely matched experimental measurements.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D seismic imaging of a fracture damage zone controlling reservoir compartmentalization at the Raft River EGS using multi-azimuth walkaway VSP

Accurate imaging of steeply dipping fracture zones in crystalline enhanced geothermal systems (EGS) is critical for constraining permeability architecture and guiding stimulation design. However, such structures remain poorly resolved by conventional surface seismic methods. We present a fully three-dimensional (3D) elastic-waveform inversion-migration workflow applied to multi-azimuth walkaway vertical seismic profiling (VSP) data acquired in a deviated borehole at the Raft River EGS. The workflow integrates first-arrival traveltime tomography, multi-scale elastic waveform inversion (EWI), and elastic least-squares reverse-time migration (ELSRTM) to recover high-resolution compressional-and shear-wave velocity models and to image structural discontinuities in the crystalline basement. The results reveal a laterally continuous low-velocity anomaly, with shear-wave velocity reductions of 25-30%, consistent with fractureinduced mechanical weakening. Two steeply dipping discontinuities bound a 50-80 m wide fracture damage zone. Independent constraints from microseismic clustering and geochemical compartmentalization corroborate the geometry and structural significance of this feature. Synthetic modeling further confirms that structures of this scale are resolvable (~30 m). These findings indicate that the Narrows structure is a distributed fracture damage zone rather than a discrete fault plane. By resolving fracture-zone geometry at the tens-of-meters scale using a single borehole, this workflow provides a practical and transferable approach for improving structural characterization, reducing uncertainty in permeability architecture, and supporting reservoir modeling and stimulation design in fractured crystalline EGS reservoirs.

58 GEOSCIENCES↗

Discrete fracture network model benchmarks developed and applied in a DECOVALEX-2023 repository performance assessment study

This study presents newly developed benchmarks for modeling flow and transport within discrete fracture networks (DFNs) and useful methods for analyzing the results. The new benchmarks are designed to test modeling approaches for use in probabilistic performance assessment models of deep geologic repositories in fractured rock. The benchmarks simulate flow and transport through a 1 km 3 block of fractured rock. The first simulates migration of a short pulse of tracer through a simple network of four intersecting fractures. The second adds 1089 stochastically generated fractures. The third changes the pulse to a continuous point source. Evaluation of model performance relies on moment analysis and comparison of the results of different models. The expected nondimensional first moment of the conservative tracer for each benchmark is 1. The benchmarks were simulated by teams from Canada, Czechia, Germany, Korea, Sweden, Taiwan, and the United States as part of a DECOVALEX-2023 study (decovalex.org). The teams used various approaches, including explicit DFN modeling, DFN upscaling to an equivalent continuous porous medium (ECPM), and a combination of both methods. Transport mechanisms are modeled using either the advection-dispersion equation or particle tracking. Results demonstrate strong agreement among the models in breakthrough behavior up to the 75th percentile. Significant deviations in first moments and well-clustered outputs led to the identification of inaccuracies in several models. Such findings exemplify the benefit of exercising these benchmarks and using the presented methods to test DFN flow and transport models.

Benchmark↗

Pseudoatom molecular dynamics plasma microfields

Spectral lines are powerful diagnostic tools for both laboratory and astrophysical plasmas, as their shape is sensitive to the plasma environment. The low-frequency component of the electric microfield is an important input for semi-analytic line broadening codes. Here, in this paper, we detail a new method of calculating plasma microfields using configuration-resolved pseudoatom molecular dynamics. This approach accounts for both quantum atomic structure and N-body effects, similar to density functional theory molecular dynamics, but with less computational cost. We present pseudoatom microfields at plasma conditions relevant for recent high energy density laboratory astrophysics experiments conducted at the Sandia Z-Machine, National Ignition Facility, and Linac Coherent Light Source. Compared to established microfield codes we find moderate deviations at solid density conditions and strong agreement at lower plasma densities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling and Experimental Validation of a Direct-Contact Counter-Flow Fluidized Bed Heat Exchanger for Thermal Energy Storage (TES) Applications

Particle-based thermal energy storage (TES) systems are an emerging energy storage technology. The technological advances have reduced costs, making TES more competitive and reliable in the marketplace but an efficient and reliable operation is heavily dependent on coherent heat transfer between air to particles or vice versa. The particle-based TES technologies provide an intermediate system that can store energy for short (0-10 h), long (10-200 h) and seasonal (> 200 h) timescales. The TES systems store energy by converting electricity to thermal energy; electricity can be directly sourced intermittent generation technologies and/or the grid, helping manage peak loads and other mismatches in supply and demand. The overall efficiency of the TES system depends on the performance of system components (particle storage silos and particle transfer mechanism etc.). The particle heat exchanger is one of the key system components that affects the system efficiency. The pressurized fluidized bed heat exchanger (PFB HX) performance is challenging to predict due to the chaotic behavior of particle and fluid interaction. This research presents a computational study of a novel direct-contact, counter-flow and air-to-particles PFB HX, that contributes in advancing the particle-based long-duration TES technologies. For the current analysis an unsteady Eulerian-Eulerian CFD model was developed and validated against experiments performed at the National Laboratory of the Rockies for two particle sizes (600 ..mu..m and 825 ..mu..m ). Following validation, parametric simulations were conducted to evaluate the effects of interphase drag models (Syamlal-O'Brien and Gidaspow), particle size, bed height and the influence of a frictional-viscosity term on hydrodynamics and heat transfer between the air & particles. The key findings from the analysis are: (1) for the studied operating window Syamlal-O'Brien provides superior agreement with measured gas temperatures (errors generally < 10%) while Gidaspow shows large deviations for the coarse particle case; (2) model predictions are most sensitive in the lower 0.2 m above the air distributor where bubble initiation and local mixing dominate interphase heat transfer; (3) representation of the distributor (number of inlet ports) materially affects predicted local mixing and temperature stratification; and (4) the Eulerian-Eulerian framework reproduces bulk thermal trends but shows regime dependent limitations for coarse particles, motivating mesoscale informed closures for scale-up analysis for future studies. These results provide validated guidance for drag selection and distributor design in particle-based thermal energy storage applications. Collectively, the validated model and parametric results quantify key drivers of PHB-HX performance and provide practical guidance for design and optimization. The results provide confidence in the model predictability and provide a step forward to improve on heat exchange performance. The demonstrated performance and modeling approach support the deployment and further development of this novel PHB-HX concept for robust, particle-based long-duration thermal energy storage systems.

25 ENERGY STORAGE↗

Free-spray characteristics and spray-wall interactions of methanol on a gasoline direct injector under flash-boiling and non-flash-boiling conditions

Methanol is considered a promising alternative fuel for internal combustion engines (ICEs) due to its high-octane number, fast laminar flame speed, and elevated latent heat of vaporization, all of which support higher compression ratios and improved thermal efficiency. However, its substantial latent heat of vaporization also poses cold-start challenges, such as misfire and fuel film deposition. This study aims to investigate methanol spray morphology and spray-wall interaction using the Spray M injector from the Engine Combustion Network within a constant-pressure flow vessel. A recently developed unified numerical framework capable of modeling both flash and non-flash boiling sprays is validated against experimental liquid volume fraction data acquired via 3-D computed tomography. Here, the results reveal that flash boiling significantly alters the spray morphology, leading to smaller droplets and spray collapse due to enhanced air-entrainment-induced turbulence. Quantitative agreement between experiments and simulations confirms this behavior. Coupled 0-D equilibrium and 3-D computational fluid dynamics analyses show that flash boiling accelerates evaporation and reduces fuel residence time, while non-flash conditions maintain a persistent liquid core more susceptible to wall wetting. Wall temperature diagnostics reveal that spray collapse alters heat transfer patterns by shifting cooling effects. Mixture fraction analysis indicates that evaporation is primarily governed by shear-layer turbulence, though deviations from adiabatic equilibrium mixing emerge under low-turbulence conditions. Finally, increasing fuel, ambient, and wall temperatures reduces wall wetting and film thickness, mitigating cold-start risks. These findings enhance the understanding of methanol sprays’ behavior and support its adoption as a viable, alternative fuel for ICEs.

Engine Combustion Network↗

Hydrogen effects on the deformation and slip localization in a single crystal austenitic stainless steel

Hydrogen is known to embrittle austenitic stainless steels, which are widely used in high-pressure hydrogen storage and delivery systems, but the mechanisms that lead to such material degradation are still being elucidated. The current work investigates the deformation behavior of single crystal austenitic stainless steel 316L through combined uniaxial tensile testing, characterization and atomistic simulations. Thermally precharged hydrogen is shown to increase the critical resolved shear stress (CRSS) without previously reported deviations from Schmid’s law. Molecular dynamics simulations further expose the statistical nature of the hydrogen and vacancy contributions to the CRSS in the presence of alloying. Slip distribution quantification over large in-plane distances (> 1 mm), achieved via atomic force microscopy (AFM), highlights the role of hydrogen increasing the degree of slip localization in both single and multiple slip configurations. The most active slip bands accumulate significantly more deformation in hydrogen precharged specimens, with potential implications for damage nucleation. For $\langle$110$\rangle$ tensile loading, slip localization further enhances the activity of secondary slip, increases the density of geometrically necessary dislocations and leads to a distinct lattice rotation behavior compared to hydrogen-free specimens, as evidenced by electron backscatter diffraction (EBSD) maps. Finally, the results of this study provide a more comprehensive picture of the deformation aspect of hydrogen embrittlement in austenitic stainless steels.

36 MATERIALS SCIENCE↗

Statistical evaluation of microscale stress conditions leading to void nucleation in the weak shock regime

Here, we investigate the heterogeneity of the stress state driven by anisotropic deformation response at the single crystal level through five statistical volume element (SVE) calculations of polycrystalline BCC tantalum. This work focuses on grain boundaries as a prominent material defect type prone to void nucleation based upon experimental observations of predominantly intergranular void nucleation in this material. The SVEs are constructed to be statistically representative of larger volumes of material and are meshed such that mean and standard deviation of grain size and orientation information is reconstructed. The computational meshes feature hexahedral (brick) elements and smooth conformal grain boundaries where significant stress concentration is known to occur, a tail effect of interest in the extreme events process of dynamic ductile damage. An existing micromechanical crystallographic plasticity model shown to capture the single crystal behavior of BCC tantalum well is used to perform the polycrystal calculations. The model includes representation of the non-Schmid effect of non-planar screw dislocation kinetics in tantalum. A three-dimensional stress state time profile predicted by damage modeling of a flyer plate impact experiment is applied as boundary conditions to each SVE. Resulting grain boundary stress state statistics are strongly non-Gaussian. Significant structural evolution is observed within the compressive hold before unloading into tension in the stress profile. Strong angular dependence of grain boundary traction magnitude with shock direction is observed. Non-Schmid effects continue to suggest their influence on propensity of microstructural defect types to nucleate voids. A general void nucleation criterion is proposed using probability theory. The general framework is specified to polycrystalline BCC tantalum in the weak shock regime to include the SVE calculations and literature molecular dynamics calculations of grain boundary void nucleation strength. Probability density functions (PDFs) are used to describe the interaction between the local stress state heterogeneity and the distributed grain boundary void nucleation strength state. A causation entropy maximization procedure removes the requirement for ad hoc selection of a PDF functional form and provides a rigorous procedure for data-based PDF determination. The resulting physically informed PDF describes the spatial appearance frequency of nucleated voids as a function of applied macroscale pressure. Lower length scale physics are thus packaged in a precise and computationally efficient way to provide computational plasticity insight to macroscale dynamic ductile damage models.

36 MATERIALS SCIENCE↗

Evaluation and development of flow condensation correlations using the data from low GWP refrigerants in an axial micro-fin aluminum tube

To mitigate global warming, the world is transitioning to refrigerants with low global warming potential (GWP). Supporting this shift requires a model that can accurately predict the heat transfer and pressure drop of new refrigerants, crucial for designing efficient heat exchangers. Existing models, however, are largely based on currently deployed refrigerants and primarily developed for unexpanded micro-fin tubes with spiral angles of 6° to 30°. Their applicability to new refrigerants, especially in expanded micro-fin tubes, is uncertain. This study assesses the performance of four well-known condensation models for six emerging refrigerants—R-32, R-454B, R-454C, R-455A, R-1234yf, and R-1234ze(E)—against experimental data. Initially, the Han and Lee (2005) model shows the best prediction accuracy with a mean absolute deviation (MAD) of 22.1 %. To enhance the accuracy of heat transfer models for new refrigerants and geometries with large temperature glides, two approaches are proposed. Here, the first approach applies a simple correction factor, reducing the MAD of the Cavallini et al. (2009) model from 68.2 % to 15.4 %. The second approach uses the variable metric method for minimization, fitting new constants to the data. This optimization results in the Kedzierski and Goncalves (1997) model achieving the highest accuracy, with a MAD of 13.1 %. For pressure drop models, the Cavallini et al. (1997) model is the most accurate with a MAD of 6.4 %, followed by the Haraguchi et al. (1993) model with a MAD of 9.4 %. Due to its simplicity, the Haraguchi et al. (1993) model is a practical option for predicting frictional pressure drop.

Axial micro-fin tubes↗

Investigation of residual stress distribution in wire-arc directed energy deposited refractory molybdenum alloy utilizing numerical thermo-mechanical analysis and neutron diffraction method

Directed energy deposition (DED), a metal additive manufacturing (AM) technique, offers higher deposition rates and energy efficiency, making it suitable for fabricating components from refractory molybdenum alloys, such as molybdenum-titanium-zirconium (TZM). However, large thermal gradients and non-equilibrium thermal cycles in DED could generate high residual stress in the component, potentially deteriorating quality and performance. Thus, this study aims to investigate residual stress generation and its distribution in wire-arc DED of TZM thin-wall, utilizing thermo-mechanical analysis and high-fidelity neutron diffraction (ND) method. Two interpass temperatures (50°C and 200°C) have been considered to investigate their impact on residual stress formation. During experiments, in-situ thermal data has been recorded using thermocouples, which have been utilized for calibrating the thermal model. Thermocouple data shows a good agreement with the simulation results, having a difference of less than 10 %. Post-deposition part deformation has been observed, which is measured using a coordinate measuring machine, showing maximum values of 0.93 mm and 0.78 mm for interpass temperatures of 50°C and 200°C, respectively. Numerical predictions of distortion deviated by less than 15% from the experimental results. ND measurement and simulation results indicate that residual stress magnitude and evolution vary across the TZM deposits, revealing microstructural anisotropy in both conditions. Notably, lower interpass temperatures resulted in higher residual stresses, confirmed by experimental and simulation data. Further, this study demonstrated that an integrated experimental and thermo-mechanical analysis can potentially reveal the temperature history, part deformation, and residual stress formation in wire-arc DED TZM alloy.

36 MATERIALS SCIENCE↗

Expanding the homogeneity range of UFe 2 : Formation of Laves phase UFe 2 +Ni

Uranium-based intermetallic Laves phases (UM 2 ) provide valuable insight into the interplay of 5f orbital hybridization and magnetic properties. However, ferromagnetism in these compounds is rare. UFe 2 is a cubic C15 Laves phase with greatest Curie temperature (T C ) of all such compounds, at 162 K. In this study, we report the synthesis and characterization of a novel U-based Laves phase, UFe 2 +Ni, effectively forcing excess Ni in to the UFe 2 structure. UFe 2 +Ni crystallizes in the cubic C15 Laves phase, appearing to deviate from the typical UM 2 formula and exhibiting a significantly extended homogeneity range. Annealing this material leads to an increased ferromagnetic transition temperature, between 35 and 155 K, and decreased lattice parameter with higher annealing temperatures. This variation is attributed to changes in Fe and Ni solubility with annealing temperature. In conclusion, our findings highlight the potential for tuning magnetic properties in U-based Laves phases through compositional and thermal modifications, expanding the understanding of magnetically ordered intermetallics.

Annealing effects↗

A hybrid Monte Carlo-deterministic second moment method with efficient variance reduction

In this work, we present a hybrid method that combines Monte Carlo with deterministic finite element methods to solve a linear Boltzmann transport equation. Our hybrid method runs orders of magnitude faster than Monte Carlo, without sacrificing accuracy, for a proxy problem from radiative transfer that contains both optically-thick and optically-thin material. We believe that this is the first demonstration of a hybrid Second Moment Method in more than one spatial dimension, the first to consider more than one material, and the first to use variance reduction. Our variance reduction approach arises from an asymptotic analysis in which we show that the magnitude of the scattering source grows without bound. We transform the problem to compute the deviation of the radiation intensity from isotropy. The magnitude of the source in the transformed problem is bounded, and the quality of the hybrid method solution is dramatically improved by a substantial reduction in the variance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗