An experimental and analytical investigation of axisymmetric diffusers
A finite difference computer program for turbulent compressible flow was used to establish the performance of several diffuser shapes for experimental testing. The diffusers were designed to have a linear change in Mach number, a linear change in pressure or a curvature fitted by a quadratic equation. Testing was performed with M = 0.1 to 0.9 with and without boundary layer bleed. Above M = 0.6, data were obtained with a normal shock upstream of the diffuser entrance. Peak static pressure recovery occurred with a diffuser inlet M-0.75. The quadratic diffuser yielded the highest total pressure recovery.