Search NASA⌕ Search

SEARCH · Search NASA

Results for “diode model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

The 60 GHz IMPATT diode development

The objective is to develop 60 GHz IMPATT diodes suitable for communications applications. The performance goals of the 60 GHz IMPATT is 1W CW output power with a conversion efficiency of 15 percent and 10-year lifetime. The final design of the 60 GHz IMPATT structure evolved from computer simulations performed at the University of Michigan. The initial doping profile, involving a hybrid double-drift (HDD) design, was derived from a drift-diffusion model that used the static velocity-field characteristics for GaAs. Unfortunately, the model did not consider the effects of velocity undershoot and delay of the avalanche process due to energy relaxation. Consequently, the initial devices were oscillating at a much lower frequency than anticipated. With a revised simulation program that included the two effects given above, a second HDD profile was generated and was used as a basis for fabrication efforts. In the area of device fabrication, significant progress was made in epitaxial growth and characterization, wafer processing, and die assembly. The organo-metallic chemical vapor deposition (OMCVD) was used. Starting with a baseline X-Band IMPATT technology, appropriate processing steps were modified to satisfy the device requirements at V-Band. In terms of efficiency and reliability, the device requirements dictate a reduction in its series resistance and thermal resistance values. Qualitatively, researchers were able to reduce the diodes' series resistance by reducing the thickness of the N+ GaAs substrate used in its fabrication.

Dat, Rovindra↗

Harmonic mixing characteristics of metal-barrier-metal junctions as predicted by electron tunneling

The bias dependence of the nonlinear mixing characteristics of metal-barrier-metal junction currents is deduced assuming an electron tunneling model. The difference-frequency beat voltage at frequency omega sub 1 - (n x omega sub 2), when n is an integer and omega sub 1 and omega sub 2 are the assumed frequencies of two induced currents, is found to have n zeros as the diode bias is varied. Recent experimental observations have demonstrated such characteristics.

Faris, S. M.↗

The 12 micron band of ethane - High-resolution laboratory analysis with candidate lines for infrared heterodyne searches

Attention is given to the results of a laboratory study of the v9 band of ethane at 12 microns, using both high resolution Fourier transform and diode laser absorption spectroscopy. The analysis to which about 2000 transitions in this band have been subjected includes the normal rotational terms as well as the higher order effects of l-doubling, l-resonance, internal rotation, and a Coriolis resonance with the 3v4 state. A model is presented for the v9 band which is able to reproduce the observed features to an accuracy of better than 0.001/cm, and a list has been compiled for v9 transitions, occurring near C-14O2 laser lines, that are good candidates for laser heterodyne searches.

Atakan, A. K.↗

A submillimeter tripler using a quasi-waveguide structure

A new type of frequency multiplier structure is being developed which is suitable for application at frequencies above 1 THz. This structure preserves some of the properties of waveguide for mode control, yet is not truly single mode. The device resembles a sectoral horn, with a varactor diode mounted near the throat. Input and output coupling are through the same aperture, requiring a quasi-optical diplexer. Initial tests are directed at building a tripler at 500 GHz, for comparison with waveguide structures. The diplexer is a blazed diffraction grating with appropriate focusing optics. Model studies show that the impedance match to a varactor should be good, and initial tests of the beam patterns of the prototype indicate that optical coupling efficiency should be very high. The structure also has the potential for use as a fundamental mixer, or as a third harmonic mixer.

Erickson, Neal R.↗

Pressure-Sensitive Paint Measurements on the NASA Common Research Model in the NASA 11-ft Transonic Wind Tunnel

The luminescence lifetime technique was used to make pressure-sensitive paint (PSP) measurements on a 2.7% Common Research Model in the NASA Ames 11ft Transonic Wind Tunnel. PSP data were obtained on the upper and lower surfaces of the wing and horizontal tail, as well as one side of the fuselage. Data were taken for several model attitudes of interest at Mach numbers between 0.70 and 0.87. Image data were mapped onto a three-dimensional surface grid suitable both for comparison with CFD and for integration of pressures to determine loads. Luminescence lifetime measurements were made using strobed LED (light-emitting diode) lamps to illuminate the PSP and fast-framing interline transfer cameras to acquire the PSP emission.

Bell, James H.↗

Proton-radiation damage in Gunn oscillators

The irradiation effects of 22 MeV protons on the electrical characteristics of GaAs continuous-wave Gunn oscillators was studied. The radio frequency power output was reduced by 3 decibels at proton fluences in the neighborhood of 1.5 x 10 to the 12th power protons/sq cm. Conductance measurements indicate that the carrier removal rate at high electric fields remained roughly 40 percent less than at low fields. Diode efficiencies of two device groups were found to be monotonically descreasing functions of fluence. Frequency modulation noise was generally unaffected by radiation, but the magnitude of the noise in the noise power spectrum increased significantly. These effects are partially accounted for, in a qualitative fashion, by a model of electron traps having field-dependent net-carrier capture rates and various response times.

Johnson, J. W.↗

Laser velocimetry with diode junctions semiconductor lasers

Measurements of mean and fluctuating axial velocity have for the first time been made in a seeded pipe flow with a semiconductor laser velocimeter. Several compact velocimeters have been constructed using laser diodes. While the intended applications have restricted the final instrument to operate in a coaxial backscatter mode, operation has been demonstrated in forward and side scattering modes. In all cases the instrument could be classed as dual beam. An instrument has been constructed to be installed in a model airfoil and will be mechanically driven to measure the flow over a 75-mm chord distance. The instrument occupies a volume measuring 100 mm x 100 mm x 40 mm. The compactness has been aided by using an avalanche photodiode instead of a photomultiplier tube.

Franke, J. M.↗

Experimental and theoretical investigations of the quality factor for N/+/P silicon solar cells

Many N(+)P silicon solar cells made with silicon from different growth techniques have current-voltage relations of the form: I = I(0) (exp(qV/AkT) - 1), where the quality factor A is nonintegral, is greater than 1, and shows a temperature dependence. The dark forward characteristics of such cells have been measured over a range of temperatures and the behavior of the factor A derived from them. Lack of agreement with previous models has led to the development of a new model, in which N(+) conduction electrons tunnel to deep levels near that side, these levels being due to junction contamination by impurities. Electron recombination then occurs with holes thermally assisted into the junction from the P side. This mechanism involves increased I(0) values over those for diffusion diode processes and thus reduces the cell power conversion efficiency.

Garlick, G. F. J.↗

A Low LET Radiation Spectrometer for Measuring Particle Doses in Space and Aircraft

This paper presents experimental data that demonstrates the feasibility of fabricating a miniature nuclear particle dosimeter for monitoring doses in aircraft and satellites. The basic instrument is a Low Linear-Energy-Transfer (LET) Radiation Spectrometer (LoLRS) that is designed to measure the energy deposited by particles with low LET values. The heart of the instrument is a Silicon-Lithium Drifted Diode (SLDD). Test results show that the LoLRS can be used to monitor the radiation threat to personnel in flights of space- and aircraft and also to generate a comprehensive data base from aviation and satellite measurements that can contribute to the formulation of more accurate environmental radiation models for dose predictions with reduced uncertainty factors.

Stassinopoulos, E. G.↗

Miniature Loop Heat Pipe with Multiple Evaporators for Thermal Control of Small Spacecraft

This paper presents an advanced miniature heat transport system for thermal control of small spacecraft. The thermal system consists of a loop heat pipe (LHP) with multiple evaporators and multiple deployable radiators for heat transfer, and variable emittance coatings on the radiators for performance enhancement. Thermoelectric coolers are used to control the loop operating temperature. The thermal system combines the functions of variable conductance heat pipes, thermal switches, thermal diodes, and the state-of-the-art LHPs into a single integrated thermal system. It retains all the performance characteristics of state-of-the-art LHPs and offers additional advantages to enhance the functionality, performance, versatility, and reliability of the system. Steady state and transient analytical models have been developed, and scaling criteria have also been established. A breadboard unit has been built for functional testing in laboratory and thermal vacuum environments. Experimental results show excellent performance of the thermal system and correlate very well with theoretical predictions.

Ku, Jentung↗

Airborne Measurements of Atmospheric Pressure made Using an IPDA Lidar Operating in the Oxygen A-Band

We report airborne measurements of atmospheric pressure made using an integrated path differential absorption (IPDA) lidar that operates in the oxygen A-band near 765 nm. Remote measurements of atmospheric temperature and pressure are needed for NASA s Active Sensing of CO2 Emissions Over Nights, Days, and Seasons (ASCENDS) mission to measure atmospheric CO2. Accurate measurements of tropospheric CO2 on a global scale are very important in order to better understand its sources and sinks and to improve our predictions of climate change. The goal of ASCENDS is to determine the CO2 dry mixing ratio with lidar measurements from space at a level of ~1 ppm. Analysis to date shows that with current weather models, measurements of both the CO2 column density and the column density of dry air are needed. Since O2 is a stable molecule that uniformly mixed in the atmosphere, measuring O2 absorption in the atmosphere can be used to infer the dry air density. We have developed an airborne (IPDA) lidar for Oxygen, with support from the NASA ESTO IIP program. Our lidar uses DFB-based seed laser diodes, a pulsed modulator, a fiber laser amplifier, and a non-linear crystal to generate wavelength tunable 765 nm laser pulses with a few uJ/pulse energy. The laser pulse rate is 10 KHz, and average transmitted laser power is ~20 mW. Our lidar steps laser pulses across a selected line O2 doublet near 764.7 nm in the Oxygen A-band. The direct detection lidar receiver uses a 20 cm diameter telescope, a Si APD detector in Geiger mode, and a multi-channel scalar to detect and record the time resolved laser backscatter in 40 separate wavelength channels. Subsequent analysis is used to estimate the transmission line shape of the doublet for the laser pulses reflected from the ground. Ground based data analysis allows averaging from 1 to 60 seconds to increase SNR in the transmission line shape of the doublet. Our retrieval algorithm fits the expected O2 lineshapes against the measurements and determines the atmospheric pressure by minimizing the error between the observations and model. We first demonstrated our airborne lidar during flights during summer 2010. We made several improvements and made measurements during the Ascends flights during July 2011. More information about the technique, lidar instrument, airborne measurements, and pressure estimates will be described in the presentation.

Riris, Haris↗

Gaussian approximation versus nearly exact performance analysis of optical communication systems with PPM signaling and APD receivers

A 25-Mb/s direct-detection optical communication system that used Q = 4 PPM (pulse-position modulation) signaling was constructed and its performance measured under laboratory conditions. The system used a single-mode AlGaAs laser diode (lambda = 834 nm) and low-noise silicon avalanche photodiode (APD). A procedure for numerically computing system performance is given that uses the nearly exact Webb approximation of the true Conradi distribution for the APD output and does not require excessive amounts of computer time. Comparison revealed that modeling the APD ouptut as a Gaussian process under conditions of negligible background radiation and low (less than 10 to the -12 A) APD bulk leakage currents leads to substantial underestimates of optimal APD gain and overestimates of system bit error probability. Examples illustrate the breakdown of the Gaussian approximation in assessing system performance. The measured performance was in excellent agreement with that predicted by the computational procedure. The system achieved a bit error probability of 10 to the -6 at a received signal energy, corresponding to an average of 60 absorbed photons/bit and optimal APD gain of 700.

Davidson, Frederic M.↗

Bypass Diode Temperature Tests of a Solar Array Coupon Under Space Thermal Environment Conditions

Tests were performed on a 56-cell Advanced Triple Junction solar array coupon whose purpose was to determine margin available for bypass diodes integrated with new, large multi-junction solar cells that are manufactured from a 4-inch wafer. The tests were performed under high vacuum with coupon back side thermal conditions of both cold and ambient. The bypass diodes were subjected to a sequence of increasing discrete current steps from 0 Amp to 2.0 Amp in steps of 0.25 Amp. At each current step, a temperature measurement was obtained via remote viewing by an infrared camera. This paper discusses the experimental methodology, experiment results, and the thermal model.

Wright, Kenneth H., Jr.↗

Determination of optimum sunlight concentration level in space for 3-5 cascade solar cells

Current-voltage curves were calculated for each cell in a cascade structure using a solar cell diode equation and superposition. Terms for the light generated current, diffusion current, space charge recombination current and series and shunt resistance are included. Individual current voltage curves are added in series with ohmic resistance losses for the cell interconnects to obtain the cascade cell performance. Temperature was varied with concentration, using several models, and ranged from 55 C at one Sun to between 80 and 200 C at 100 Suns. A variety of series resistance and internal resistances were used. Coefficients of the diffusion and recombination terms are strongly temperature dependent. The study indicates that maximum efficiency (30%) occurs in the 50 to 100X Sun concentration range, provided series resistance is below 0.015 ohm-sq cm and cell temperature is 80 C at 100 Suns.

Curtis, H. B.↗

Ultra Stable Microwave Radiometers for Future Sea Surface Salinity Missions

The NASA Earth Science System Pathfinder (ESSP) mission Aquarius will measure global sea surface salinity with 100-km spatial resolution every 8 days with an average monthly salinity accuracy of 0.2 psu (parts per thousand). This requires an L-band low-noise radiometer with the long-term calibration stability of less than 0.1 K over 8 days. This three-year research program on ultra stable radiometers has addressed the radiometer requirements and configuration necessary to achieve this objective for Aquarius and future ocean salinity missions. The system configuration and component performance have been evaluated with radiometer testbeds at both JPL and GSFC. The research has addressed several areas including component characterization as a function of temperature, a procedure for the measurement and correction for radiometer system non-linearity, noise diode calibration versus temperature, low noise amplifier performance over voltage, and temperature control requirements to achieve the required stability. A breadboard radiometer, utilizing microstrip-based technologies, has been built to demonstrate this long-term stability. This report also presents the results of the radiometer test program, a detailed radiometer noise model, and details of the operational switching sequence optimization that can be used to achieve the low noise and stability requirements. Many of the results of this research have been incorporated into the Aquarius radiometer design and will allow this instrument to achieve its goals.

sea surface salinity↗

NASA Tech Briefs, September 2010

Topics covered include: Instrument for Measuring Thermal Conductivity of Materials at Low Temperatures; Multi-Axis Accelerometer Calibration System; Pupil Alignment Measuring Technique and Alignment Reference for Instruments or Optical Systems; Autonomous System for Monitoring the Integrity of Composite Fan Housings; A Safe, Self-Calibrating, Wireless System for Measuring Volume of Any Fuel at Non-Horizontal Orientation; Adaptation of the Camera Link Interface for Flight-Instrument Applications; High-Performance CCSDS Encapsulation Service Implementation in FPGA; High-Performance CCSDS AOS Protocol Implementation in FPGA; Advanced Flip Chips in Extreme Temperature Environments; Diffuse-Illumination Systems for Growing Plants; Microwave Plasma Hydrogen Recovery System; Producing Hydrogen by Plasma Pyrolysis of Methane; Self-Deployable Membrane Structures; Reactivation of a Tin-Oxide-Containing Catalys; Functionalization of Single-Wall Carbon Nanotubes by Photo-Oxidation; Miniature Piezoelectric Macro-Mass Balance; Acoustic Liner for Turbomachinery Applications; Metering Gas Strut for Separating Rocket Stages; Large-Flow-Area Flow-Selective Liquid/Gas Separator; Counterflowing Jet Subsystem Design; Water Tank with Capillary Air/Liquid Separation; True Shear Parallel Plate Viscometer; Focusing Diffraction Grating Element with Aberration Control; Universal Millimeter-Wave Radar Front End; Mode Selection for a Single-Frequency Fiber Laser; Qualification and Selection of Flight Diode Lasers for Space Applications; Plenoptic Imager for Automated Surface Navigation; Maglev Facility for Simulating Variable Gravity; Hybrid AlGaN-SiC Avalanche Photodiode for Deep-UV Photon Detection; High-Speed Operation of Interband Cascade Lasers; 3D GeoWall Analysis System for Shuttle External Tank Foreign Object Debris Events; Charge-Spot Model for Electrostatic Forces in Simulation of Fine Particulates; Hidden Statistics Approach to Quantum Simulations; Reconstituted Three-Dimensional Interactive Imaging; Determining Atmospheric-Density Profile of Titan; Digital Microfluidics Sample Analyzer; Radiation Protection Using Carbon Nanotube Derivatives; Process to Selectively Distinguish Viable from Non-Viable Bacterial Cells; and TEAMS Model Analyzer.

Source record↗

Qualitative evaluation of a conformal velocity vector display for use at high angles-of-attack in fighter aircraft

A piloted simulation study was conducted to evaluate the utility of a display device designed to illustrate graphically and conformally the approximate location of a fighter aircraft's velocity vector. The display device consisted of two vertical rows of light emitting diodes (LED's) located toward the center of the cockpit instrument panel to each side of the control stick. The light strings provided a logical extension of the head up display (HUD) velocity vector symbol at flight path angles which exceeded the HUD field-of-view. Four test subjects flew a modified F/A-18 model with this display in an air-to-air engagement task against an equally capable opponent. Their responses to a questionnaire indicated that the conformal velocity vector information could not be used during the scenarios investigated due to the inability to visually track a target and view the lights simultaneously.

Jones, Denise R.↗

IceCube: Demonstration of an 883 GHz Radiometer for Ice Cloud Remote Sensing

IceCube was a technology demonstration of an 883 GHz heterodyne radiometer on a 3U CubeSat for ice cloud characterization. The project was a collaboration between Goddard Space Flight Center, Virginia Diodes Inc., and Wallops Flight Facility. IceCube was launched to the International Space Station (ISS) in April 2017, and was deployed to the orbit in May 2017. The radiometer measured ice cloud emissions from an ISS orbit for over 15 months. IceCube generated the first 883 GHz cloud map over a large operation temperature range of (5 ºC—37 ºC). Cloud ice plays a major role in the cloud precipitation process and Earth’s energy budget. Ice clouds are used in global circulation models as tuning parameters to achieve model agreement with observation at the top of the atmosphere in the radiation budget and at the bottom for precipitation, however, due to a lack of accurate ice cloud measurements large uncertainties exist in these models. Submillimeter wave remote sensing is capable of addressing this issue by measuring cloud ice mass and microphysical properties in the middle-to-upper troposphere. This fills the sensitivity gap not covered by the visible/infrared and microwave sensors [1]. The goal of IceCube was to increase the TRL of a heterodyne 883 GHz radiometer (using commercial parts) from 5 to 7 by validating the performance in a relevant spaceflight environment. The design of the radiometer was driven by frequency of operation, bandwidth, calibration, available power, and thermal environment requirements. The design included a 15 mm aperture off-axis parabolic reflector with a Potter feed horn, an 883 GHz 2nd-harmonic mixer that is fed by a local oscillator chain with a 24.3 GHz dielectric resonator (MLA), followed by a 6 GHz bandwidth centered at 9 GHz intermediate frequency assembly (IFA), receiver interface card, and power distribution unit. The IFA included an internal noise diode calibration to separate the MLA performance from the rest of the system. For this the radiometer had four operational states: antenna, antenna + noise, reference, and reference + noise; each state’s duration was 10 ms. The total power dissipation of the instrument was 5.6 W. The spacecraft had spinning capabilities to provide a cold sky view for calibration. We present the instrument design, ground test results, challenges, and highlight some of the flight measurements.

N Ehsan↗