Search NASA⌕ Search

SEARCH · Search NASA

Results for “disassembly”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Carbon Scaffold Architectures for Stable Lithium Metal Anodes

In light of the skyrocketing demand for electric vehicles and consequent need for high-performing lithium-ion batteries, there has been significant research into the creation of a battery with a lithium metal anode due to its high theoretical capacity and energy density. Unfortunately, nonuniform lithium deposition and consequent dendrite growth diminish performance and pose a safety risk. To combat this, lightweight carbon scaffolds are being developed to stabilize the electric field of these batteries and induce uniform deposition through rational design at the nano-, micro-, and meso- scales. However, there is a paucity of research on the impacts of macroscale scaffold topology on lithium cycling performance. Here, we report the creation of two graphite-based scaffolds with distinct 3D topologies: one a series of triangular prisms and one a series of rectangular prisms. Coin cells were made using these scaffolds and cycled at a current of 1mA/cm2 for 50 cycles to test the performance. The triangular topology was found to outperform the rectangular topology in terms of both potential magnitude and stability during cycling. Disassembling the cells revealed more even lithium deposition on the rectangular scaffold; however, some of the rectangular prisms were broken while all the triangular prisms remained intact. Last, future experiments are proposed regarding the scaffold spacing and mass of the cells in order to isolate the topological impact.

25 ENERGY STORAGE↗

UCO TRISO Minifuel FY23 NSUF-Kairos Power Post-Irradiation Examination Status Report

Irradiation of miniature tristructural isotropic (TRISO)–coated particle fuel compacts at high-power particle was performed in the Oak Ridge National Laboratory’s (ORNL’s) High Flux Isotope Reactor (HFIR) using the MiniFuel irradiation capability. Each compact comprised 20 TRISO particles with a low-enriched uranium carbide uranium oxide (UCO), natural UCO, or low-enriched UO 2 kernel within a graphitic matrix. After irradiation, the MiniFuel targets and subcapsules were disassembled to recover the irradiated fuel specimens and pursue post-irradiation examination (PIE) to inform Kairos Power on the fuel specimen performance. This report describes the PIE results collected to date, including dilatometry on the passive thermometry to confirm the irradiation temperature, fission gas release measurements, and gamma counting. This work was funded by the Nuclear Science User Facilities program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SPC-70646 Specification for Reactor Supplemental Shielding for Use in DOME

NRIC is developing the Demonstration of Microreactor Experiments (DOME) test bed at the Idaho National Laboratory (INL) Materials and Fuels Complex (MFC): to allow for testing of advanced reactors in support of future licensing and commercial operations. One such need is a neutron and photon radiation shielding system to protect personnel and equipment from harsh neutron and photon fluxes during reactor operations and post shut down operations, disassembly, and decommissioning.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

Multiphysics Simulations of MSRE with NEAMS Thermal Hydraulics Tools

This report documents the benchmarks being developed and simulations performed using tools and codes developed under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, utilizing MSRE experimental data. In FY23, three main work scopes were investigated under the NEAMS MSR work package at ANL. The first scope investigated the Griffin-SAM coupling model for simulating the pump startup transient experiment of MSRE. The analyses start with a simple model (single-channel, single-lattice), gradually adding more details (multi-channel, full-core) into the model. The results show that the reactivity loss curve is very sensitive to the axial boundary conditions and the radial core discretization. The simple model can predict a similar reactivity trend as that of the more sophisticated model, which is likely due to error cancellation. Accurately modeling the axial boundary condition may further improve the reactivity trend but would require significant efforts to generate the mesh of the MSRE inlet and upper plenum. The core channel radial discretization for the Griffin-SAM coupled model also depends on the flow distribution. Given the complex geometry in the inlet plenum, the flow distribution needed to be calculated from CFD analysis, which was performed using the NekRS code. This analysis employed a MSRE CAD model developed by Copenhagen Atomics. The CAD model was disassembled to keep the inlet plenum region only, which was subsequently cleaned and modified so that the mesh generated is under the memory limit. The results are merged to a few radial regions to show that the flow rate is highest in the central region. This would be useful for future improvement of the Griffin-SAM coupling model of the MSRE core. The last task investigated is tritium transport modeling using the standalone SAM code. This task aimed to initiate the effort to demonstrate and validate the tritium transport model implemented in SAM. The preliminary investigation employed an MSRE model consisting of the primary loop. Three tritium transport pathways were examined including the retention in the graphite, the permeation through the HX tube wall, and the removal from the off-gas system. The results compare well with the MSRE data, but improvements are still needed on the initial conditions (i.e., the present state may not have reached equilibrium), the boundary conditions, the off-gas system modeling, and a better numerical strategy to reach the equilibrium state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

3013 Fire Test 2020: Post-Test Measurements and Analysis

Sandia National Laboratory conducted fire tests on ten 3013 containers with varying amounts of water. The containers with attached manifolds were sent to Los Alamos National Laboratory for post-test measurements of the plastic deformation, the amount of water remaining on the material post-test and the mass loss. The measurements of the plastic deformation were used to determine the free gas volume in each container and manifold post-test. The disassembly of each container was documented by photographs. The amount of pre-test gas constituents is also reported using data in the Sandia Final Report.

3013 fire test↗

Accelerated Lifetime Testing of Main Shaft Seals for Tidal Turbine Rotors

This document will briefly discuss the observations and results from an NREL conducted accelerated lifetime testing of the main shaft seal for the Verdant Power fifth generation Gen5 underwater Tidal Energy Converter (TEC) turbine, which successfully performed at the RITE project in 2020-2021. In order to evaluate a 5-year Service Interval ( SI) for this component, testing at NREL operated the main shaft seal nearly continuously for over 135 (text says 130 days on page 5 and 125 days on page 7 and 137 days on page 11) days at a rotational velocity of 160 rpm while the test stand recorded water pressure, barrier fluid pressure, temperature, and number of cycles., representing ~ 40% of the SI. An additional separate test was conducted to measure the aging behavior of the rubber drive rings. The water pressure reservoir was held constant as 29 psi. Barrier fluid pressure remained relatively constant throughout the duration of the test but was seen to sink to as low as 10.1 psi. No barrier fluid leakage was observed throughout the test. A sudden failure occurred within the seal after the power to test machine was interrupted for a scheduled building maintenance procedure. Upon restarting, the main shaft seal lost all ability to prevent water ingress. The exact cause is not known but is believed to be either a seal assembly issue or a change in the alignment of the seal components during or following the power outage. Following seal disassembly, significant wear was seen on one of the graphite sealing rings. Based on these results it is recommended that a follow-on TEAMER be conducted to rectify protocol and assembly issues to further evaluate SI of this component. The support and participation of Verdant Power Inc, Dovetail Solutions LLC and Garlock Manufacturing Inc were instrumental in understanding the results. NREL thanks them for their significant effort.

13 HYDRO ENERGY↗

An Inverse Heat Conduction Algorithm Used to Calculate the Temperatures on the Inner and Outer Cylindrical Surfaces of an HMX-based PBX Explosive Annulus

In this work, a new Inverse Heat Conduction (IHC) algorithm is applied to estimate the surface temperatures at twelve locations on the inner and outer cylindrical boundaries of an HMX-based Plastic Bonded Explosive (PBX) annulus. This IHC algorithm was developed in references using a set of Direct Heat Conduction (DHC) solutions and a temperature correction method. The DHC solutions were calculated using a Galerkin based finite element (FE) method. This HMX based PBX annulus was used in the Large Scale Annular Cookoff (LSAC) experiment, Shot 5. The reason Shot 5 was chosen as a prototype mathematical model for this study is that the temperature was measured at eighteen locations in the midplane of the HMX-based PBX annulus. In addition, this annulus underwent an experimental thermal ignition and a deflagration that caused a thermal explosion and the disassembly of the experiment. The objective of this study is to describe how the application of the temperature correction algorithm produced the convergence of the DHC solutions to the measured temperatures at twelve internal locations in the midplane of the HMX-based PBX annulus.

36 MATERIALS SCIENCE↗

FY23 Update: Aerosol Sampling for the Canister Deposition Field Demonstration

This report describes the results of preliminary testing of aerosol monitoring equipment that will be used to continuously monitor the aerosol source term for the multi-year Canister Deposition Field Demonstration (CDFD). These data are required inputs for the development and validation of models for the deposition of dust and potentially corrosive salts on the surface of spent nuclear fuel (SNF) dry storage canisters. Surface salt loads correlate with the extent of corrosion damage on a metal surface, and potentially to the likelihood and timing of initiation of stress corrosion cracks. Aerosols will be monitored at the CDFD site using three instruments. A Dekati ® ELPI+ cascade impactor will be used for real-time monitoring of aerosol particle sizes. It will also collect dust in 14 size bins on impactor targets that can be chemically analyzed to determine the soluble salts present as a function of particle size. However, this instrument can only measure dried aerosols, with a diameter of <10 µm. The second instrument is a Topas laser particle size spectrometer, which provides real-time monitoring of aerosol particle sizes up to ~40 µm in size. It monitors both the ambient (potentially deliquesced) aerosol particle size distributions required for the dust deposition models and the distributions of the equivalent dried particles, allowing correlation with the Dekati ® data. However, it does not discriminate between inert dust particles and salt aerosols, and it does not retain samples of the different particle sizes for later analysis. The third instrument that will monitor aerosols at the CDFD site is a Clean Air Status and Trends Network (CASTNET) tower, which uses a multiple canister system to collect weekly samples for analysis to total suspended aerosol particle compositions and atmospheric gas concentrations. This status report describes work in FY23 to develop the capabilities for using these tools. In two training exercises, the cascade impactor and laser particle sizer were deployed in two different testing environments, one indoor and one outdoor. For the cascade impactor, the tests provided opportunities for the operators to familiarize themselves with impactor substrate preparation, and post-test sample removal and analysis. For the laser particle sizer, the tests were used to evaluate different instrument parameters, to determine the most appropriate settings for capturing transient events. Data and samples were collected for weeks to months for each test, and the results are presented here. In addition to the preliminary testing, contracts were developed with WSP Analytical Labs for sample preparation and analysis of the cascade impactor samples. The impactor tower from outdoor test was delivered to WSP and used to train the staff there in disassembly, sample extraction, sample analysis, and tower reassembly with new target substrates. These are tasks that WSP will be performing routinely for the CDFD project. The CASTNET system cannot be purchased or tested until an actual site has been selected for the CDFD test. Work for this FY has been restricted to preparation of contracts for purchasing the CASTNET tower, and for sample analysis, once the tower is in operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ROADRUNNER MiniFuel Experiment: Irradiation Target Design and Sample Characterization

High-density uranium nitride (UN) is a fuel candidate for several advanced nuclear reactor designs currently under development. Because there are limited UN performance data relative to fuel fabrication impurity and density variation, an irradiation campaign has been developed as part of a collaborative effort among the University of Texas at San Antonio (UTSA), Westinghouse Electric Company, Oak Ridge National Laboratory (ORNL), and Los Alamos National Laboratory (LANL) under the Nuclear Science User Facilities program. This project, entitled ROADRUNNER, or Research On ADvancing the peRformance of UraNium Nitrides in Extreme enviRonments, aimsto support UN fuel qualification for advanced reactors by investigating the impact of density and impurity variations on UN performance as a function of irradiation temperature and burnup. The MiniFuel experiment vehicle developed by ORNL, which leverages the High Flux Isotope Reactor, was selected to perform this accelerated separate-effects irradiation testing. The experiment test matrix consists of six MiniFuel targets containing miniature UN fuel disks, and targets three distinct burnup levels (37.5, 60, and 75 MWd/kg U) and three distinct temperatures (600, 900, and 1200°C). Neutronics and thermal analyses were performed to determine the experimental parameters needed to meet the desired irradiation conditions and to predict the experiment components temperatures. UN pellets were fabricated at LANL with tightly controlled parameters to produce specimens with three distinct densities and three levels of carbon content. The pellets were then thinned down by UTSA to the experiment-required thickness. The pre-characterization of the specimens includes density measurements, carbon and oxygen contents, microstructure analysis, and x-ray computed tomography. The selected specimens will be assembled into the MiniFuel experiment, and the first ROADRUNNER MiniFuel targets are intended for HFIR insertion during the Fall of 2024. After irradiation, the targets will be shipped to ORNL’s hot cell facility for disassembly. The post-irradiation examination on the fuel specimens includes fission gas release measurements, visual inspection, fuel swelling measurements, gamma spectroscopy, and microstructure analysis. The data collected post-irradiation will be used to develop fuel performance models.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Surveillance Workload Divinator (SWORD)

The LANL Surveillance Workload Divinator (SWORD) is a high-level decision support tool that reproduces and predicts the annual values for stockpile and production disassembly and inspections (D&I) and rebuilds. SWORD, a spreadsheet-based tool, can be used to assess the surveillance workload under various planning scenarios. Results are shown graphically and updated dynamically for each weapon system or for the entire stockpile. Surveillance workload is calculated from stockpile surveillance guidance1 and from Production and Planning Directive (P&PD) data.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Saltstone Paddles and Augers Materials of Construction Study

The Saltstone Production Facility (SPF) uses a 10-inch READCO continuous, co-rotating twin-screw mixer to mix the dry premix with the low-level radioactive waste (LLW) salt solution to produce fresh saltstone grout. The paddles and augers within the mixer degrade via erosion in the region where the salt solution is introduced into the mixer. After the paddles/augers erode to a point where the throughput impacts operations, the mixer is disassembled, the effected paddles/augers are replaced, and the mixer is reassembled. Saltstone Engineering indicated that this effort requires an approximately three-week outage. The objective of this task is to assess alternative materials of construction (MOCs) that will provide better erosion characteristics and decrease the frequency in which the paddles and augers need replacement. Previous Astralloy V studies looked only at Charpy Impact and Rockwell Hardness Testing. Each of these will be examined for different alloys as well as Miller Testing (abrasion to determine wear) which will provide a good assessment of an alloy’s erosion/wear characteristics. The following facts concerning the current and proposed alloys for Saltstone Paddles and Augers are provided in this report. • Current Astralloy V material and alloy E52100 had the most favorable Miller Testing Results. • Charpy Impact Testing did not correlate with Miller Testing Results. • Hardness Testing correlated with Miller Testing results meaning that higher hardness will provide more favorable wear resistance. • Further investigation of E52100 and various tool grade steels is recommended for achieving wear resistant properties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Long-term Moisture Adsorption in Packaged Plutonium Oxide

In 2018, the Department of Energy National Nuclear Security Administration (DOE-NNSA) began implementing dilute and dispose to remove 34 metric tons (MT) of surplus weapons grade plutonium from the US stockpile. Under this plan, surplus plutonium material is converted into plutonium oxide (PuO 2 ) before being stored in metal containers and sent to the DOE Waste Isolation Pilot Plant (WIPP). The dilute and dispose project was implemented as a more cost-effective method for abiding by the Plutonium Management and Disposition Agreement (PMDA) between the USA and Russia, as compared to producing mixed oxide fuel (MOX). The PMDA was originally signed in 2000 and amended in 2010.2 The disassembly of pits and conversion to PuO 2 as part of dilute and dispose is carried out through the Advanced Recovery and Integrated Extraction System (ARIES) developed at Los Alamos National Laboratory (LANL). The dilute portion of dilute and dispose is carried out at Savannah River Site (SRS). With this program in place, it is necessary to ensure the safe, long-term storage of the PuO 2 generated during this process until final disposal at WIPP is accomplished.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recycling Wind Energy Systems in the United States Part 1: Providing a Baseline for America's Wind Energy Recycling Infrastructure for Wind Turbines and Systems

The U.S. investments in building this new wind energy capacity will not only mobilize millions of tons of raw and processed materials in existing supply chains, some of which are critical materials, but also create new types and large volumes of end-of-life (EOL) waste streams. Building efficient, cost-effective, and environmentally responsible EOL management infrastructure of wind energy system components is pivotal in diverting upcoming volumes of waste stream from landfills, recovery of critical materials and reducing life cycle emissions from production of primary commodity materials . The primary goal of this report is to organize and communicate findings from this assessment on how alternate materials, designs and manufacturing processes could enable more efficient, cost-effective, and environmentally responsible disassembly and resource recovery from wind energy technologies. The findings of this assessment could inform prioritization of RD&D investment spending to meet Energy Act of 2020 directions. This assessment focused on key RD&D recommendations for three main temporal phases: Short-term (2023-2026), medium-term (2026 through 2035) and long-term (beyond 2035).

17 WIND ENERGY↗

Automated Inspection of Criticality Control Overpacks for Surplus Plutonium Disposition: Qualification Update – 25313

In an effort to reduce the amount of nuclear waste in South Carolina, the Department of Energy (DOE) tasked the Savannah River Site (SRS) with diluting and disposing of the amount of plutonium in the state. This process involves the movement and shipment of over 100,000 criticality control overpacks (CCOs) throughout the project lifespan, lending itself to the use of automation to reduce worker radiation exposure and more efficiently utilize human capital. Due to the large scope, this overarching process was broken down into several different “automation projects” to be developed. The first opportunity pursued was the receipt and inspection of empty CCO drums coming into SRS, identified as Automation Project 1 (AP1), and is the focus of this paper. AP1 was developed to unpack incoming CCOs and inspect them for unwanted foreign objects and any damage to the drum or its contents. This process is accomplished by the combination of an automated guided vehicle (AGV) that delivers CCOs to a robotic arm which uses a suite of custom tools to disassemble a CCO, inspect the inside and outside of the CCO and its inner criticality control container (CCC), reassemble the CCC and CCO, and apply a tamper indicating device (TID) to the inspected drum. In past years, the robotic work cell had been developed in a small-scale testing facility for proof-of-concept. This year, major improvements were made to the robotic work cell to perform the process, including integration into the final facility where CCOs will be inspected. Other technical improvements include the implementation of sensor feedback and safety relays into the control system to allow the state of the work cell to be better tracked, and additional development of the TID application process to complete the robotic inspection. Further enhancements were made to the robotic vision processes and robot pathing, as well as development on a computer vision inspection process to detect inspection criteria anomalies in CCOs. In addition to developmental improvements, the work cell underwent a six-month testing period to ensure the project requirements were met. Results of this testing period demonstrate the work cell’s capability to meet project throughput goals at an acceptable level, successfully document the status of each CCO inspected, and reduce the toll on technical operations’ human power by two thirds. At the time of this paper, the work cell is capable of autonomously handling up to eight CCOs with an AGV, delivering CCOs to and from the robot work cell, and having a robotic arm perform a full receipt and inspection procedure on each CCO. Moving forward, repeatability will be improved so that these CCOs can be run back-to-back seamlessly, as well as improving the system to handle more significant edge cases and failure modes.

Spivey, Nicholas↗

Molecular theory capability: LANL-PEM-Atomic implements universal descriptions of molecular photoionization

Photoionization of atomic ions, the process through which atoms in bound states absorb radiation by losing electrons, is a vital part of describing radiative transfer in mission-relevant dynamics. The photoionization of molecules dominates radiative transfer of ultraviolet (UV) and extreme UV (EUV) radiation in colder atmospheres (temperature < 30,000 degrees Kelvin). Consequently, air, which is quite transparent to our eyes (i.e., in the visible frequency regime) is remarkably opaque to radiation in much of the UV and EUV frequency regimes. This opacity makes air and other gas systems quite efficient at absorbing UV and EUV radiation, which heats the gas until ionization makes it transparent. This effect is important in describing a host of relevant phenomena, ranging from charge separation in high-altitude nuclear events and the dynamics of a nuclear fireball to the electrostatic discharges (sparks) that complicate weapons disassembly at Pantex.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nano- and Earth-Science-inspired Electric Vehicle Battery Recycling to Secure Battery Supply Chain

With the expected growth of electric vehicles (EV) in the transportation sector, recycling or upcycling spent battery materials will be required to reduce EV costs, lessen waste, and ease critical material supply chain pressure for EV battery applications. “Direct” recycling or upcycling is an alternative to current industrial approaches. Many challenges remain for viable direct battery upcycling, including upgrading the transition metal ratio in the costliest component (cathode oxide); separation of transition metal ions in the exit stream; battery disassembly; improving cathode exfoliation which can lead to a new way of direct recycling; and lithium metal anode recycling -- including safety concerns. We devise and deploy a suite of methods to deal with these challenges. The results pave the way to future work on battery recycling, in areas of technological/commercial readiness level ranging from basic research to large-scale commercialization.

25 ENERGY STORAGE↗