Search NASA⌕ Search

SEARCH · Search NASA

Results for “dosing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

The Importance of Radiation Dose to the Atherosclerotic Plaque in the Left Anterior Descending Coronary Artery for Radiation-Induced Cardiac Toxicity of Breast Cancer Patients?

Radiation-induced acute coronary events (ACEs) may occur as a treatment-related late adverse effect of breast cancer (BC) radiation. However, the underlying mechanisms behind this radiation-induced cardiac disease remain to be determined. The objective of this study was to test the hypothesis that radiation dose to calcified atherosclerotic plaques in the left anterior descending coronary artery (LAD) is a better predictor for ACEs than radiation dose to the whole heart or left ventricle in patients with BC treated with radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Multi-Institutional Phase 2 Trial of High-Dose SAbR for Prostate Cancer Using Rectal Spacer

High-dose SABR for prostate cancer offers the radiobiologic potency of the most intensified radiation therapy regimens but was associated with >90% rates of ulceration of the anterior rectal wall on endoscopic assessment; this infrequently progressed to severe rectal toxicity in prior prospective series. A multi-institutional phase 2 prospective trial was conducted to assess whether placement of a perirectal hydrogel spacer would reduce acute periprostatic rectal ulcer events after high-dose (>40 Gy) SABR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Dose-Escalated Chemoradiation on Quality of Life in Patients With Locally Advanced Rectal Cancer: 2-Year Follow-Up of the Randomized RECTAL-BOOST Trial

Dose-escalated chemoradiation (CRT) for locally advanced rectal cancer did not result in higher complete response rates but initiated more tumor regression in the randomized RECTAL-BOOST trial (Clinicaltrials.gov NCT01951521). This study compared patient reported outcomes between patients who received dose-escalated CRT (5 × 3 gray boost + CRT) or standard CRT for 2 years after randomization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reactor cell neutron dose for the molten salt breeder reactor conceptual design

The private sector’s interest in the active development of molten salt reactors has led to the need to develop and test advanced modeling and simulation tools to analyze various advanced reactor types under numerous conditions. This paper discusses the effort undertaken to model the Oak Ridge National Laboratory (ORNL) Molten Salt Breeder Reactor (MSBR) design using ORNL’s Shift Monte Carlo code. The MSBR model integrates a Monte Carlo N-Particle (MCNP) MSBR core model with an MCNP model that was generated from a CAD model of the external components and the reactor building, which was subsequently run in Shift. This paper focuses on development of the fully integrated model and its use in performing neutron transport calculations in the reactor cell area. This model is intended to aid in understanding radiological dose conditions during operation, as well as the iron dpa rates in the reactor vessel. The neutron biological dose rates and flux calculated in the reactor cell are much higher in the MSBR than in typical light-water reactors. The implications of these results and future work are also discussed in this paper.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Unraveling radiation damage and healing mechanisms in halide perovskites using energy-tuned dual irradiation dosing

Perovskite photovoltaics have been shown to recover, or heal, after radiation damage. Here, we deconvolve the effects of radiation based on different energy loss mechanisms from incident protons which induce defects or can promote efficiency recovery. We design a dual dose experiment first exposing devices to low-energy protons efficient in creating atomic displacements. Devices are then irradiated with high-energy protons that interact differently. Correlated with modeling, high-energy protons (with increased ionizing energy loss component) effectively anneal the initial radiation damage, and recover the device efficiency, thus directly detailing the different interactions of irradiation. We relate these differences to the energy loss (ionization or non-ionization) using simulation. Dual dose experiments provide insight into understanding the radiation response of perovskite solar cells and highlight that radiation-matter interactions in soft lattice materials are distinct from conventional semiconductors. These results present electronic ionization as a unique handle to remedying defects and trap states in perovskites.

14 SOLAR ENERGY↗

Development of a New Chelation Model: Bioassay Data Interpretation and Dose Assessment after Plutonium Intake via Wound and Treatment with DTPA

The administration of chelation therapy to treat significant intakes of actinides, such as plutonium, affects the actinide’s normal biokinetics. In particular, it enhances the actinide’s rate of excretion, such that the standard biokinetic models cannot be applied directly to the chelation-affected bioassay data in order to estimate the intake and assess the radiation dose. Here we propose a new chelation model that can be applied to the chelation-affected bioassay data after plutonium intake via wound and treatment with DTPA. In the proposed model, chelation is assumed to occur in the blood, liver, and parts of the skeleton. Ten datasets, consisting of measurements of 14 C-DTPA, 238 Pu, and 239 Pu involving humans given radiolabeled DTPA and humans occupationally exposed to plutonium via wound and treated with chelation therapy, were used for model development. The combined dataset consisted of daily and cumulative excretion (urine and feces), wound counts, measurements of excised tissue, blood, and post-mortem tissue analyses of liver and skeleton. The combined data were simultaneously fit using the chelation model linked with a plutonium systemic model, which was linked to an ad hoc wound model. The proposed chelation model was used for dose assessment of the wound cases used in this study.

60 APPLIED LIFE SCIENCES↗

Near, far, wherever you are: simulations on the dose efficiency of holographic and ptychographic coherent imaging

Different studies in X-ray microscopy have arrived at conflicting conclusions about the dose efficiency of imaging modes involving the recording of intensity distributions in the near (Fresnel regime) or far (Fraunhofer regime) field downstream of a specimen. A numerical study is presented on the dose efficiency of near-field holography, near-field ptychography and far-field ptychography, where ptychography involves multiple overlapping finite-sized illumination positions. Unlike what has been reported for coherent diffraction imaging, which involves recording a single far-field diffraction pattern, it is found that all three methods offer similar image quality when using the same fluence on the specimen, with far-field ptychography offering slightly better spatial resolution and a lower mean error. These results support the concept that (if the experiment and image reconstruction are done properly) the sample can be near or far; wherever you are, photon fluence on the specimen sets one limit to spatial resolution.

42 ENGINEERING↗

Using the CAP88 Plume Model & Dose Assessment Code for the FTWC Project

The Environmental Protection & Compliance Division (EPC) uses the Clean Air Act Assessment Package – 1988 (CAP88) plume model and dose assessment code to evaluate measured emissions or projected emissions of airborne radionuclides from Los Alamos National Laboratory (LANL) facilities. This software package will use facility data (e.g., stack height and exit velocity), emissions parameters (chemical form and quantity), and environmental data (wind speed and direction) to predict downwind concentrations of radioactive material and subsequent dose to a member of the public at that location. The United States Environmental Protection Agency (EPA) has approved CAP88 for use in demonstrating compliance with the Radionuclide NESHAP2, that portion of the Clean Air Act addressing emissions of airborne radioactive material from Department of Energy facilities. EPC Division has two procedures which discuss the use of CAP88.

61 RADIATION PROTECTION AND DOSIMETRY↗

Assessment of Potential Dose and Environmental Impacts from Proposed Testing at the INL Radiological Response Training Range

This assessment uses screening level models to calculate potential environmental impacts from proposed tests at the Idaho National Laboratory (INL) Radiological Response Training Range (RRTR) site. Proposed tests could be conducted using 11 different radioactive material types that include K 2 O, LaBr 3 , KBr, Cu, Zr, F, Ga, Ga 2 O 3 , NaNO 2 , Ga-68, and Tc-99m. The tests could potentially release radioactive material to the atmosphere and radionuclides and other contaminants to the soil, which could leach into the unsaturated zone and migrate to the aquifer. Atmospheric transport of radionuclides to potential human receptors and time-integrated air concentrations were calculated with a Gaussian plume model and three years of hourly meteorological data. Potential surface-soil impacts were calculated with the computer program Mixing-Cell Model (MCM). Groundwater impacts were calculated with the computer programs MCM and GWSCREEN. Radiological doses from potential atmospheric releases were calculated for public receptors off the INL Site and for workers at nearby INL facilities. Results were compared to regulatory dose limits. Maximum potential groundwater concentrations were estimated in the aquifer below the NSTR site and compared to drinking water standards or risk-based screening levels for resident tap water. Soil concentrations were calculated and compared to risk-based screening levels for workers and potential future residents. All impacts were estimated based on the assumption that 12 tests are conducted annually using all 11 material types for a period of 15 years. This document provides the resources to enable a subject matter expert in the field of environmental assessments to replicate the modeling and calculations. The methodology and parameters are presented in the text. All electronic files, including computer code input, output, executable files, batch files, scripts, and spreadsheet files are contained in a zip file that can be accessed by selecting “Additional Information” (select Native File) in the INL Electronic Document Management System (EDMS).

99 GENERAL AND MISCELLANEOUS↗

Assessment of Potential Dose and Environmental Impacts from Proposed Testing at the INL National Security Test Range

This assessment uses screening level models to calculate potential environmental impacts from proposed tests at two locations at the Idaho National Laboratory (INL) National Security Test Range (NSTR) site. Proposed tests could be conducted using 11 different radioactive material types that include K 2 O, LaBr 3 , KBr, Cu, Zr, F, Ga, Ga 2 O 3 , NaNO 2 , Ga-68, and Tc-99m. The tests could potentially release radioactive material to the atmosphere and radionuclides and other contaminants to the soil, which could leach into the unsaturated zone and migrate to the aquifer. Atmospheric transport of radionuclides to potential human receptors and time-integrated air concentrations were calculated with a Gaussian plume model and three years of hourly meteorological data. Potential surface soil impacts were calculated with the computer program Mixing-Cell Model (MCM). Groundwater impacts were calculated with the computer programs MCM and GWSCREEN. Radiological doses from potential atmospheric releases were calculated for public receptors off the INL Site and for workers at nearby INL facilities. Results were compared to regulatory dose limits. Maximum potential groundwater concentrations were estimated in the aquifer below the NSTR site and compared to drinking water standards or risk-based screening levels for resident tap water. Soil concentrations were calculated and compared to risk-based screening levels for workers and potential future residents. All impacts were estimated based on the assumption that 12 tests are conducted annually using all 11 material types for 15 years. This document provides the resources to enable a subject matter expert in the field of environmental assessments to replicate the modeling and calculations. The methodology and parameters are presented in the text. All electronic files, including computer code input, output, executable files, batch files, scripts, and spreadsheet files, are contained in a zip file that can be accessed by selecting “Additional Information” (select Native File) in the INL Electronic Document Management System (EDMS).

99 GENERAL AND MISCELLANEOUS↗

E-Area Low-Level Waste Facility Inadvertent Human Intruder Limits and Doses in Support of the PA2022

This report documents the inadvertent human intruder (IHI) analysis for the E-Area Low-Level Waste Facility (ELLWF) at the Savannah River Site (SRS), near Aiken, South Carolina. This analysis supports the 2022 Performance Assessment for ELLWF, complying with the Department of Energy standard for operation of low-level waste disposal facilities (USDOE, 2017). The ELLWF is an operating waste disposal facility and is scheduled to continue accepting waste to 2065. One task of the 2022 Performance Assessment (PA) is to establish waste inventory limits for the various disposal units at ELLWF. This is done by modeling future contaminant release and transport through applicable pathways to human receptors, comparing predicted doses per disposed curie with applicable performance measures, to obtain inventory limits which will assure that doses to receptors do not exceed performance measures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of the MARVEL Reactor Inhalation Dose Consequences

A dose consequence analysis was performed to support the preliminary Microreactor Applications Research Validation and Evaluation Project (MARVEL) design effort. The purpose of the MARVEL project is to develop a nuclear microreactor applications test bed at Idaho National Laboratory (INL) to perform research and development on various operational features of microreactors to ultimately improve integration of microreactors to end-user applications. The MARVEL concept is a 100 kilowatt (kW) thermal (kWth) and approximately 20-kW electric (kWe) generating microreactor. The MARVEL system will be located in the INL TREAT facility in the north high-bay equipment pit. The analysis considers the bounding release fractions of the MARVEL reactor concept and documents the dose consequences to the public and collocated worker.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ECAR-5127 Rev 1 Evaluation of the MARVEL Reactor Inhalation Dose Consequences

The following dose consequence analysis is performed to support the preliminary Microreactor Applications Research Validation and Evaluation Project (MARVEL) design effort. The purpose of the MARVEL project is to develop a nuclear microreactor applications test bed at Idaho National Laboratory (INL) to perform research and development on various operational features of microreactors to ultimately improve integration of microreactors to end-user applications. The MARVEL concept is a 100 kilowatt (kW) thermal (kWth) and approximately 20-kW electric (kWe) generating microreactor. The MARVEL system will be located in the INL TREAT facility in the north high-bay equipment pit. This ECAR considers the bounding release fractions of the MARVEL reactor concept and documents the dose consequences to the public and collocated worker.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Atom Probe Tomography Characterization of High-Dose Ion Irradiated MA957

This paper presents a comprehensive characterization study of the microstructural responses to ion irradiation of the oxide dispersion strengthened (ODS) ferritic alloy MA957 using atom probe tomography (APT). The MA957 specimens were irradiated by 1.8 MeV Cr3+ ions to doses and temperatures relevant to advanced fast reactors (100 and 500 dpa at 400-500 °C). The average sizes of the YTiO particles decreased slightly after irradiation at all temperatures, with the most pronounced change at 400 °C. The particle number densities for 400 and 500 °C were slightly below number densities for the unirradiated condition, while the values were slightly higher at 420 and 450 °C. This behavior is consistent with the Nelson-Hudson-Mazey rate theory model that considers the competing effects between recombination and dissolution. An increase in the Y/Ti ratio of the YTiO particles was observed at the two lower temperatures. The formation of Cr-rich precipitates (a') was observed in specimens irradiated at temperatures up to 450 °C. Irradiation-induced segregation on grain boundaries was also investigated. Grain boundary element concentration profiles and ion maps demonstrate differences among the irradiation temperatures, with most datasets differing from the unirradiated condition. A key focus of this ion irradiation study is the high-dose response, and this quantitative assessment revealed relatively small but distinct effects of irradiation on microstructure evolution. Overall, these results showing minor second phase evolution suggest that MA957 should retain mechanical performance generally well up to 500 dpa for the irradiation temperatures studied.

Wang, Jing↗