Search NASA⌕ Search

SEARCH · Search NASA

Results for “drop impact”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Modeling and Simulation of the Second-Generation Orion Crew Module Air Bag Landing System

Air bags were evaluated as the landing attenuation system for earth landing of the Orion Crew Module (CM). Analysis conducted to date shows that airbags are capable of providing a graceful landing of the CM in nominal and off-nominal conditions such as parachute failure, high horizontal winds, and unfavorable vehicle/ground angle combinations, while meeting crew and vehicle safety requirements. The analyses and associated testing presented here surround a second generation of the airbag design developed by ILC Dover, building off of relevant first-generation design, analysis, and testing efforts. In order to fully evaluate the second generation air bag design and correlate the dynamic simulations, a series of drop tests were carried out at NASA Langley s Landing and Impact Research (LandIR) facility in Hampton, Virginia. The tests consisted of a full-scale set of air bags attached to a full-scale test article representing the Orion Crew Module. The techniques used to collect experimental data, develop the simulations, and make comparisons to experimental data are discussed.

Timmers, Richard B.↗

High Resolution Observations of Drop Size Distribution for GPM Ground Validation

During the Mid-latitude Continental Convective Cloud Experiment (MC3E), NASA's GPM GV Disdrometer and Radar Observations of Precipitation (DROP) Facility deployed an array of disdrometers and rain gauges in northern Oklahoma to sample, with high resolution, the drop size distribution for use in development of precipitation retrieval algorithms for the GPM core satellites. The DROP Facility instruments deployed during MC3E consisted of 16 autonomous Parsivel units, 5 two-dimensional video disdrometers (2dvds), a vertically pointing K band radar, and 32 tipping bucket rain gauges. There were several rainfall events during MC3E in which rain drops exceeding 6 mm in diameter were recorded. The disdrometer array revealed large rain drops with diameters exceeding 6 mm and 8 mm during two separate stratiform and convective rainfall events, respectively. The NPOL radar, which was scanning in high resolution RHI mode (every 40 sec) over the disdrometer array during the stratiform event, indicated a 1 km thick bright band with a differential reflectivity column of 2-3 dB extending below the melting layer to the surface where the large drops were recorded by the 2dvds. These large drops are important for GPM since they can have a great impact upon satellite precipitation retrieval, especially near the ground and below heavy convective rainfall cores where satellites have had problems depicting the rainfall.

Gatlin, Patrick N.↗

Mass Modeling of NEP Power Conversion Concepts for Human Mars Exploration

The specific mass (mass per unit of electric power output) of an NEP power conversion system is an important metric for the performance and feasibility of a crewed NEP vehicle. This work explores a component level buildup of the specific mass for a crewed NEP vehicle. The buildup is highly parametric and avoids being tied to specific technologies where practical. This allows the specific mass to be calculated for a variety of assumptions and operating conditions and be used to optimize particular design variables or compare different system configurations. The values of specific mass are dependent on assumptions with significant uncertainty; comparison between cases and trends observed in the models are the main goal of the work presented here. To demonstrate the level of insight this type of modeling can provide, the impacts of compressor inlet temperature, turbine inlet temperature, and radiator pressure drop on specific mass are explored. In addition, the specific mass can be used to assess the benefit of separating the radiator and reactor loop from the power conversion cycle.

NEP↗

Mass Modeling of NEP Power Conversion Concepts for Human Mars Exploration

The specific mass (mass per unit of electric power output) of an NEP power conversion system is an important metric for the performance and feasibility of a crewed NEP vehicle. This work explores a component level buildup of the specific mass for a crewed NEP vehicle. The buildup is highly parametric and avoids being tied to specific technologies where practical. This allows the specific mass to be calculated for a variety of assumptions and operating conditions and be used to optimize particular design variables or compare different system configurations. The values of specific mass are dependent on assumptions with significant uncertainty; comparison between cases and trends observed in the models are the main goal of the work presented here. To demonstrate the level of insight this type of modeling can provide, the impacts of compressor inlet temperature, turbine inlet temperature, and radiator pressure drop on specific mass are explored. In addition, the specific mass can be used to assess the benefit of separating the radiator and reactor loop from the power conversion cycle.

nep↗

Electric Mars: A Large Trans-Terminator Electric Potential Drop on Closed Magnetic Field Lines Above Utopia Planitia

Abstract Parallel electric fields and their associated electric potential structures play a crucial role inionospheric-magnetospheric interactions at any planet. Although there is abundant evidence that parallel electric fields play key roles in Martian ionospheric outflow and auroral electron acceleration, the fields themselves are challenging to directly measure due to their relatively weak nature. Using measurements by the Solar Wind Electron Analyzer instrument aboard the NASA Mars Atmosphere and Volatile EvolutioN(MAVEN) Mars Scout, we present the discovery and measurement of a substantial (Phi) Mars 7.7 +/-0.6 V) parallel electric potential drop on closed magnetic field lines spanning the terminator from day to night above the great impact basin of Utopia Planitia, a region largely free of crustal magnetic fields. A survey of the previous 26 orbits passing over a range of longitudes revealed similar signatures on seven orbits, with a mean potential drop (Phi) Mars of 10.9 +/- 0.8 V, suggestive that although trans-terminator electric fields of comparable strength are not ubiquitous, they may be common, at least at these northerly latitudes.

Magnetic↗

Incorporation of Functionalized Polyhedral Oligomeric Silsesquioxane Nanomaterials as Reinforcing Agents for Impact Ice Mitigating Coatings

In-flight, aircraft are exposed to a wide range of environments. One commonly exposed environment are clouds containing super-cooled water droplets. These water drop- lets exist in a metastable state below the freezing point of water, in the range of 0 to -20°C. As the vehicle impacts the droplets, latent heat is released and within milliseconds the droplets convert to ice. This process is referred to as impact icing or in-flight icing.1 Impact icing is a major concern for aircraft since it can lead to degraded aerodynamic performance and, if left un- treated, can lead to loss of the vehicle. Active approaches (i.e., pneumatic boots, heated air ducts) typically utilized in mitigating in-flight ice accretion significantly increases vehicle weight and cannot be applied to all aircraft.1-3 A passive approach based on coatings is desired, but durability issues are a concern, especially on the wing leading edge.3 Nanomaterials have been shown to afford significant improvement in coating and composite physical properties at low loading levels.4 In this study, Polyhedral Oligomeric Silsesquioxane (POSS) nanomaterials have been shown to increase coating durability. Also, with wide variety of functionalities present on the arm structure, POSS nanomaterials have been shown to readily alter coating surface chemistry to mitigate impact ice adhesion from -16 to -8°C in a simulated in-flight icing environment.

Beck, Devon M.↗

Comparison of Instantaneous Frequency Scaling from Rain Attenuation and Optical Disdrometer Measurements at K/Q bands

Rain attenuation is strongly dependent on the rain rate, but also on the rain drop size distribution (DSD). Typically, models utilize an average drop size distribution, such as those developed by Laws and Parsons, or Marshall and Palmer. However, individual rain events may possess drop size distributions which could be significantly different from the average and will impact, for example, fade mitigation techniques which utilize channel performance estimates from a signal at a different frequency. Therefore, a good understanding of the characteristics and variability of the raindrop size distribution is extremely important in predicting rain attenuation and instantaneous frequency scaling parameters on an event-toevent basis. Since June 2014, NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) have measured the attenuation due to rain in Milan, Italy, on the 20/40 GHz beacon signal broadcast from the Alphasat TDP#5 Aldo Paraboni Q/V-band Payload. Concomitant with these measurements are the measurements of drop size distribution and rain rate utilizing a Thies Clima laser precipitation monitor (disdrometer). In this paper, we discuss the comparison of the predicted rain attenuation at 20 and 40 GHz derived from the drop size distribution data with the measured rain attenuation. The results are compared on statistical and real-time bases. We will investigate the performance of the rain attenuation model, instantaneous frequency scaling, and the distribution of the scaling factor. Further, seasonal rain characteristics will be analysed.

millimeter wave↗

An Assessment of Molten Metal Detachment Hazards During Electron Beam Welding in the Space Shuttle Bay at LEO for the International Space Welding Experiment

In 1997, the United States [NASA] and the Paton Electric Welding Institute are scheduled to cooperate in a flight demonstration on the U.S. Space Shuttle to demonstrate the feasibility of welding in space for a possible repair option for the International Space Station Alpha. This endeavor, known as the International Space Welding Experiment (ISWE), will involve astronauts performing various welding exercises such as brazing, cutting, welding, and coating using an electron beam space welding system that was developed by the E.O. Paton Electric Welding Institute (PWI), Kiev Ukraine. This electron beam welding system known as the "Universal Weld System" consists of hand tools capable of brazing, cutting, autogeneous welding, and coating using an 8 kV (8000 volts) electron beam. The electron beam hand tools have also been developed by the Paton Welding Institute with greater capabilities than the original hand tool, including filler wire feeding, to be used with the Universal Weld System on the U.S. Space Shuttle Bay as part of ISWE. The hand tool(s) known as the Ukrainian Universal Hand [Electron Beam Welding] Tool (UHT) will be utilized for the ISWE Space Shuttle flight welding exercises to perform welding on various metal alloy samples. A total of 61 metal alloy samples, which include 304 stainless steel, Ti-6AI-4V, 2219 aluminum, and 5456 aluminum alloys, have been provided by NASA for the ISWE electron beam welding exercises using the UHT. These samples were chosen to replicate both the U.S. and Russian module materials. The ISWE requires extravehicular activity (EVA) of two astronauts to perform the space shuttle electron beam welding operations of the 61 alloy samples. This study was undertaken to determine if a hazard could exist with ISWE during the electron beam welding exercises in the Space Shuttle Bay using the Ukrainian Universal Weld System with the UHT. The safety issue has been raised with regard to molten metal detachments as a result of several possible causes such as welder procedural error, externally applied impulsive forces(s), filler wire entrainment and snap-out, cutting expulsion, and puddle expulsion. Molten metal detachment from either the weld/cut substrate or weld wire could present harm to a astronaut in the space environment it the detachment was ti burn through the fabric of the astronaut Extravehicular Mobility Unit (EMC). In this paper an experimental test was performed in a 4 ft. x 4 ft. vacuum chamber at MSFC enabling protective garment to be exposed to the molten metal drop detachments to over 12 inches. The chamber was evacuated to vacuum levels of at least 1 x 10(exp -5) torr (50 micro-torr) during operation of the 1.0 kW Universal Hand Tool (UHT). The UHT was manually operated at the power mode appropriate for each material and thickness. The space suit protective welding garment, made of Teflon fabric (10 oz. per yard) with a plain weave, was placed on the floor of the vacuum chamber to catch the molten metal drop detachments. A pendulum release mechanism consisting of four hammers, each weighing approximately 3.65 lbs, was used to apply an impact forces to the weld sample/plate during both the electron beam welding and cutting exercises. Measurements were made of the horizontal fling distances of the detached molten metal drops. The volume of a molten metal drop can also be estimated from the size of the cut. Utilizing equations, calculations were made to determine chande in surafec area (Delat a(surface)) for 304 stainless steel for cutting based on measurements of metal drop sizes at the cut edges. For the cut sample of 304 stainless steel based on measurement of the drop size at the edge, Delta-a(surface) was determined to be 0.0054 2 in . Calculations have indicated only a small amount of energy is required to detach a liquid metal drop. For example, approximately only 0.000005 ft-lb of energy is necessary to detach a liquid metal steel drop based on the above theoretical analysis. However, some of the energy will be absorbed by the plate before it reaches the metal drop. Based on the theoretical calculations, it was determined that during a weld cutting exercise, the titanium alloy would be the most difficult to detach molten metal droplets followed by stainless steel and then by aluminum. The results of the experimental effort have shown that molten metal will detach if large enough of a hammer blow is applied to the weld sample plate during the full penetration welding and cutting exercises. However, no molten metal detachments occurred as a result of the filler wire snap-out tests from the weld puddle since it was too difficult to cause the metal to flick-out from the pool. Molten metal detachments, though not large in size, did result from the direct application of the electron beam on the end of the filler weld wire.

Fragomeni, James M.↗

Can salt on an optical rain gauge lens affect performance?

The optical rain gauge (ORG) by ScTI is designed to be tolerant to reduction of infrared beam intensity due to a dirty lens. Recently there is interest in long term use of optical gauges onboard buoys at sea. Because of logistics, these systems are serviced infrequently, i.e., every several months. Due to the proximity of the gauges to the sea surface, salt can be expected to be deposited on the lens. To obtain an indication of the potential for dirty lens to affect the ORG calibration, two simple experiments were conducted. In the control experiment, a sample ORG was compared to three other ORG's during natural rain events. Next a translucent mask was placed on the transmitter lens of the sample ORG and again data were collected under natural rain conditions. The mask reduced the gain of the perturbed ORG by about 30%. The perturbed ORG operated rather well in that the mask only causes a change in the gain and does not cause data drop out at low rain rates. However, the reduced gain would seriously impact an assessment of rain statistics.

Bliven, Larry F.↗

Scaling Effects in Carbon/Epoxy Laminates Under Transverse Quasi-Static Loading

Scaling effects were considered for 8, 16, 32, and 64 ply IM-7/8551-7 carbon/epoxy composites plates transversely loaded to the first significant load drop by means of both a quasi-static and an equivalent impact force. The resulting damage was examined by x-ray and photomicroscopy analysis. Load-deflection curves were generated for the quasi-static tests and the resulting indentation depth was measured. Results showed that the load-deflection data scaled well for most of the various thicknesses of plates. However, damage did not scale as well. No correlation could be found between dent depth and any of the other parameters measured in this study. The impact test results showed that significantly less damage was formed compared to the quasi- static results for a given maximum transverse load. The criticality of ply-level scaling (grouping plies) was also examined.

Nettles, Alan T.↗

Examination of Relationship Between Photonic Signatures and Fracture Strength of Fused Silica Used in Orbiter Windows

A commercially available grey-field polariscope (GFP) instrument for photoelastic examination is used to assess impact damage inflicted upon the outermost pane of the orbiter windows. Four categories of damage: hyper-velocity impacts that occur during space-flight (HVI); hypervelocity impacts artificially made at the Hypervelocity Impact Technology Facility (HIT-F); impacts made by larger objects falling onto the pane surface to simulate dropped items on the window during service/storage of vehicle (Bruises); and light scratches from dull objects designed to mimic those that might occur by dragging a dull object across the glass surface (Chatter Checks) are examined. The damage sites are cored from fused silica window carcasses, examined with the GFP and other methodologies, and broken using the ASTM Standard C1499-09 to measure the fracture strength. A correlation is made between the fracture strength and damage-site measurements including geometrical measurements and GFP measurements of photoelastic retardation (stress patterns) surrounding the damage sites. An analytical damage model to predict fracture strength from photoelastic retardation measurements is presented and compared with experimental results.

Yost, William T.↗

Evaluation of the New Version of the Laser-Optical Disdrometer, Parsivel

Disdrometer based hydrometeor size distribution measurements have a wide range of application in radar meteorology among other disciplines. The low-cost laser optical disdrometer which became commercially available in 2005 opened a new era to study the variability of the hydrometeor size distribution. The pixel and footprint scale variability of the ground and spaceborne radar remote sensing of precipitation, respectively, has been investigated through a network of Parsivel disdrometers. At the same timE, the cross comparison of impact-type, two-dimensional video and laser-optical disdrometers highlighted the relative strengths and weaknesses of each type of disdrometer. The Parsivel instrument tended to underestimate the number of small drops less than 0.8 mm in diameter quite severely, while the size of drops larger than 2.0 mm in diameter were overestimated at heavy rain quite frequently. Through a close collaboration with the manufacturer, these shortcomings were attributed to the inexpensive laser device. The manufacturer has just released a beta version of Parsivel2. The preliminary comparisons with old and new versions of Parsivel, impact type disdrometer and rain gauges showed a noticeable improvement of the Parsivel at both small and large drop end. This presentation will demonstrate the evaluation of the new unit and its potential impact on radar rainfall relations, including polarimetric and high frequency radar rainfall.

Tokay, Ali↗

Results from Two Full-Scale Hawker 4000 Fuselage Drop Tests

In the spring of 2022, NASA Langley Research Center (LaRC) conducted two full-scale drop tests on a Hawker 4000 partial fuselage structure for the evaluation of composite material response under dynamic impact loading conditions. The specific objectives of the tests were to induce dynamic composite damage initiation and progression and in primary structure and to understand the nature of the failure modes. The tests were conducted via dividing the fuselage hardware into three smaller sections. Dynamic drop tests were conducted on the forward and aft portions of the fuselage under different dynamic loading conditions, while the middle section was reserved for materials testing. Both tests were conducted by dropping the test articles from a height of 14 feet with significant amounts of pitch, which was added to initiate damage in specific regions of the structure. The test articles were ballasted then instrumented with accelerometers at various locations and speckle-coated on both exterior sides with a black and white stochastic pattern for use with three-dimensional digital image correlation (3D-DIC). In addition, the interior belly portion of the forward section test article was also speckle-coated, which was intended to capture deformations on the belly of the test article from the interior at impact. The interior of the aft section test article was not speckle-coated. Prior to testing, bow-tie markers were applied at various locations for use in marker tracking, to measure impact conditions such as vertical impact velocity and pitch. In this report, a partial summary of the data collected from the tests is presented. The data was primarily in the form of accelerometers to measure impact acceleration and 3D-DIC to measure deformation and failure onset and propagation. Post-test inspections revealed the primary damage mechanism was fiber cracking and delamination primarily in and around the area that contacted the impact surface. Acceleration pulse shapesin the ballast locations were trapezoidal in nature and ranged between 10 g and 40 g, depending on the location and test.

full scale testing↗

Results from Two Full-Scale Hawker 4000 Fuselage Drop Tests

In the spring of 2022, NASA Langley Research Center (LaRC) conducted two full-scale drop tests on a Hawker 4000 partial fuselage structure for the evaluation of composite material response under dynamic impact loading conditions. The specific objectives of the tests were to induce dynamic composite damage initiation and progression and in primary structure and to understand the nature of the failure modes. The tests were conducted via dividing the fuselage hardware into three smaller sections. Dynamic drop tests were conducted on the forward and aft portions of the fuselage under different dynamic loading conditions, while the middle section was reserved for materials testing. Both tests were conducted by dropping the test articles from a height of 14 feet with significant amounts of pitch, which was added to initiate damage in specific regions of the structure. The test articles were ballasted then instrumented with accelerometers at various locations and speckle-coated on both exterior sides with a black and white stochastic pattern for use with three-dimensional digital image correlation (3D-DIC). In addition, the interior belly portion of the forward section test article was also speckle-coated, which was intended to capture deformations on the belly of the test article from the interior at impact. The interior of the aft section test article was not speckle-coated. Prior to testing, bow-tie markers were applied at various locations for use in marker tracking, to measure impact conditions such as vertical impact velocity and pitch. In this report, a partial summary of the data collected from the tests is presented. The data was primarily in the form of accelerometers to measure impact acceleration and 3D-DIC to measure deformation and failure onset and propagation. Post-test inspections revealed the primary damage mechanism was fiber cracking and delamination primarily in and around the area that contacted the impact surface. Acceleration pulse shapesin the ballast locations were trapezoidal in nature and ranged between 10 g and 40 g, depending on the location and test.

full scale testing↗

Elemental Water Impact Test: Phase 3 Plunge Depth of a 36-Inch Aluminum Tank Head

Spacecraft are being designed based on LS-DYNA water landing simulations. The Elemental Water Impact Test (EWIT) series was undertaken to assess the accuracy of LS-DYNA water impact simulations. Phase 3 featured a composite tank head that was tested at a range of heights to verify the ability to predict structural failure of composites. To support planning for Phase 3, a test series was conducted with an aluminum tank head dropped from heights of 2, 6, 10, and 12 feet to verify that the test article would not impact the bottom of the test pool. This report focuses on the comparisons of the measured plunge depths to LS-DYNA predictions. The results for the tank head model demonstrated the following. 1. LS-DYNA provides accurate predictions for peak accelerations. 2. LS-DYNA consistently under-predicts plunge depth. An allowance of at least 20% should be added to the LS-DYNA predictions. 3. The LS-DYNA predictions for plunge depth are relatively insensitive to the fluid-structure coupling stiffness.

Vassilakos, Gregory J.↗

A Comparative Analysis of Occupant Response Between Component and Full Vehicle Tests of Fokker F28 Aircraft Hardware

In 2019, the National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC) conducted a full-scale crash test of a Fokker F28 MK1000 aircraft. This test concluded a multi-year research effort in which two component fuselage sections of a matching Fokker F28 aircraft were previously tested under similar vertical impact conditions. Due to facility and cost constraints of full-scale testing, aircraft are typically evaluated through component level tests (i.e. vertical drops of fuselage subsections or isolated seat tests). Although more practical, these tests are limited in their ability fully replicate the complex multi-axis loading environment induced on the occupants during a full-aircraft crash event. Because of this, there is risk that component level testing does not provide a complete assessment of vehicle crashworthiness. Comparative analysis between full-scale and component level testing of the Fokker F28 aircraft provides an excellent opportunity to evaluate differences in crashworthiness prediction made between these levels of test fidelity. In this study, Anthropomorphic Test Device (ATD, a.k.a crash test dummies) responses measured during the Fokker full scale impact test were compared to those measured in the component fuselage section drops. A variety of ATD configurations (5th, 50th, 95th) and positions (upright, braced) were tested in both the full-scale and component tests. ATD injury metric response comparisons were made across these ATD variations in addition to comparisons made with respect to ATD location within the vehicle. Results found the addition of horizontal impact velocity, achieved in the full-scale testing, along with aircraft structural effects altered ATD based crashworthiness assessment of the vehicle.

Crashworthiness↗

Soft-short management and remediation in 10-year-old NiCds in Geo orbit

After 10 years in Geo orbit, during the spring 1993 eclipse season, soft shorts occurred in cells of two of the three batteries on the F2R spacecraft On battery #1, the cell soft short turned suddenly into a hard short; the resulting sudden 1.2V fall in battery voltage and rise in temperature was observed via telemetry. On battery #3, the deleterious impact of its soft short increased day by day, manifesting itself as a drop in battery voltage part-way through each eclipse, causing high loading on the remaining good battery. This paper reports how by planned charge management, including applying (against-the-book) overcharge ratios (C/D) exceeding 1.75, the battery #3 cell soft short was 'built down' until the cell voltage fade ceased. The problem with the battery #3 soft-shorted cell was fought with partial success throughout the latter half of the fall 93 season, and the lessons learned were applied to alleviate the problem during the spring 94 and fall 94 eclipse seasons. The life of the spacecraft was successfully prolonged until it was retired in March 1995.

Flordeliza, Nicanor A.↗