Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Spin dynamics, short-range order, and spin freezing in Y{sub 0.5}Ca{sub 0.5}BaCo{sub 4}O{sub 7}

Y{sub 0.5}Ca{sub 0.5}BaCo{sub 4}O{sub 7} was recently introduced as a possible candidate for capturing some of the predicted classical spin kagome ground-state features. Stimulated by this conjecture, we have taken up a more complete study of the spin correlations in this compound with neutron scattering methods on a powder sample characterized with high-resolution neutron diffraction and the temperature dependence of magnetic susceptibility and specific heat. We have found that the frustrated near-neighbor magnetic correlations involve not only the kagome planes but concern the full Co sublattice, as evidenced by the analysis of the wave-vector dependence of the short-range order. We conclude from our results that the magnetic moments are located on the Co sublattice as a whole and that correlations extend beyond the two-dimensional kagome planes. We identify intriguing dynamical properties, observing high-frequency fluctuations with a Lorentzian linewidth {Gamma}{<=}20 meV at ambient temperature. On cooling a low-frequency ({approx}1 meV) dynamical component develops alongside the high-frequency fluctuations, which eventually becomes static at temperatures below T{approx_equal}50 K. The high-frequency response with an overall linewidth of {approx}10 meV prevails at T{<=}2 K, coincident with a fully elastic short-range-ordered contribution.

36 MATERIALS SCIENCE↗

An analysis of I/O efficient order-statistic-based techniques for noise power estimation in the HRMS sky survey's operational system

Noise power estimation in the High-Resolution Microwave Survey (HRMS) sky survey element is considered as an example of a constant false alarm rate (CFAR) signal detection problem. Order-statistic-based noise power estimators for CFAR detection are considered in terms of required estimator accuracy and estimator dynamic range. By limiting the dynamic range of the value to be estimated, the performance of an order-statistic estimator can be achieved by simpler techniques requiring only a single pass of the data. Simple threshold-and-count techniques are examined, and it is shown how several parallel threshold-and-count estimation devices can be used to expand the dynamic range to meet HRMS system requirements with minimal hardware complexity. An input/output (I/O) efficient limited-precision order-statistic estimator with wide but limited dynamic range is also examined.

Zimmerman, G. A.↗

Reynolds stress tensor measurements using magnetic resonance velocimetry: expansion of the dynamic measurement range and analysis of systematic measurement errors

This study presents magnetic resonance velocimetry (MRV) Reynolds Stress measurements in a periodic hill channel with a hill Reynolds number of Re = 29,500. The velocity encoding scheme is based on the ICOSA6 method with six icosahedral encoding directions and multiple encoding values are measured to increase the dynamic range. The full Reynolds stress tensor is obtained from a voxel-wise three-dimensional Gaussian fit using the magnitude data of all acquisitions. The MRV results are compared to a wall-resolved large eddy simulation and laser Doppler velocimetry measurements conducted in the same channel. It is shown that the MRV Reynolds stress data have excellent precision and agree qualitatively with the reference data. However, there are apparent systematic deviations. One of the most prominent error contributions is the signal attenuation caused by higher orders of motion, which leads to an overestimation of the turbulence level. Another fundamental error is identified in the assumption that the turbulence is Gaussian distributed. With the presented reconstruction technique, the MRV data are fitted to a statistical model, and depending on the examined flow setup, the Gaussian model can lead to considerable errors. Possible ways of how to reduce all identified errors are presented. In summary, this technique enables Reynolds stress tensor measurements in complex internal flows with high dynamic range and excellent precision. However, several issues need to be resolved to make the turbulence quantification more accurate.

42 ENGINEERING↗

Pulse measurement apparatus and method

An embodiment of the invention is directed to a pulse measuring system that measures a characteristic of an input pulse under test, particularly the pulse shape of a single-shot, nano-second duration, high shape-contrast optical or electrical pulse. An exemplary system includes a multi-stage, passive pulse replicator, wherein each successive stage introduces a fixed time delay to the input pulse under test, a repetitively-gated electronic sampling apparatus that acquires the pulse train including an entire waveform of each replica pulse, a processor that temporally aligns the replicated pulses, and an averager that temporally averages the replicated pulses to generate the pulse shape of the pulse under test. An embodiment of the invention is directed to a method for measuring an optical or an electrical pulse shape. The method includes the steps of passively replicating the pulse under test with a known time delay, temporally stacking the pulses, and temporally averaging the stacked pulses. An embodiment of the invention is directed to a method for increasing the dynamic range of a pulse measurement by a repetitively-gated electronic sampling device having a rated dynamic range capability, beyond the rated dynamic range of the sampling device; e.g., enhancing the dynamic range of an oscilloscope. The embodied technique can improve the SNR from about 300:1 to 1000:1. A dynamic range enhancement of four to seven bits may be achieved.

47 OTHER INSTRUMENTATION↗

The feasibility of a piecewise-linear dynamic bowtie filter

Purpose: The prepatient attenuator (or 'bowtie filter') in CT is used to modulate the flux as a function of fan angle of the x-ray beam incident on the patient. Traditional, static bowtie filters are tailored only for very generic scans and for the average patient. The authors propose a design for a dynamic bowtie that can produce a time-dependent piecewise-linear attenuation profile. This dynamic bowtie may reduce dynamic range, dose or scatter, but in this work they focus on its ability to reduce dynamic range, which may be particularly important for systems employing photon-counting detectors. Methods: The dynamic bowtie is composed of a set of triangular wedges. Each wedge is independently moved in order to produce a time-dependent piecewise-linear attenuation profile. Simulations of the bowtie are conducted to estimate the dynamic range reduction in six clinical datasets. The control of the dynamic bowtie is determined by solving a convex optimization problem, and the dose is estimated using Monte Carlo techniques. Beam hardening artifacts are also simulated. Results: The dynamic range is reduced by factors ranging from 2.4 to 27 depending on the part of the body studied. With a dynamic range minimization objective, the dose to the patient can be reduced from 6% to 33% while maintaining peak image noise. Further reduction in dose may be possible with a specific dose reduction objective. Beam hardening artifacts are suppressed with a two-pass algorithm. Conclusions: A dynamic bowtie producing a time-dependent, piecewise-linear attenuation profile is possible and can be used to modulate the flux of the scanner to the imaging task. Initial simulations show a large reduction in dynamic range. Several other applications are possible.

60 APPLIED LIFE SCIENCES↗

An algorithm to correct saturated mass spectrometry ion abundances for enhanced quantitation and mass accuracy in omic studies

The mass accuracy and peak intensity of ions detected by mass spectrometry (MS) measurements are essential to facilitate compound identification and quantitation. However, high concentration species can easily cause problems if their ion intensities reach beyond the limits of the detection system, leading to distorted and non-ideal detector response (e.g. saturation), and largely precluding the calculation of accurate m/z and intensity values. Here we present an open source computational method to correct peaks above a defined intensity (saturated) threshold determined by the MS instrumentation such as the analog-to-digital converters or time-to-digital converters used in conjunction with time-of-flight MS. In this method, the isotopic envelope for each observed ion above the saturation threshold is compared to its expected theoretical isotopic distribution. The most intense isotopic peak for which saturation does not occur is then utilized to re-calculate the precursor m/z and correct the intensity, resulting in both higher mass accuracy and greater dynamic range. The benefits of this approach were evaluated with proteomic and lipidomic datasets of varying complexities. After correcting the high concentration species, reduced mass errors and enhanced dynamic range were observed for both simple and complex omic samples. Specifically, the mass error dropped by more than 50% in most cases with highly saturated species and dynamic range increased by 1-2 orders of magnitude for peptides in a blood serum sample.

Environmental Molecular Sciences Laboratory↗

Sound velocity of tantalum under shock compression in the 18–142 GPa range

Dynamic compression experiments of tantalum (Ta) within a shock pressure range from 18–142 GPa were conducted driven by explosive, a two-stage light gas gun, and a powder gun, respectively. The time-resolved Ta/LiF (lithium fluoride) interface velocity profiles were recorded with a displacement interferometer system for any reflector. Sound velocities of Ta were obtained from the peak state time duration measurements with the step-sample technique and the direct-reverse impact technique. The uncertainty of measured sound velocities were analyzed carefully, which suggests that the symmetrical impact method with step-samples is more accurate for sound velocity measurement, and the most important parameter in this type experiment is the accurate sample/window particle velocity profile, especially the accurate peak state time duration. From these carefully analyzed sound velocity data, no evidence of a phase transition was found up to the shock melting pressure of Ta.

36 MATERIALS SCIENCE↗

Dynamic granularity of imaging systems

Imaging systems that include a specific source, imaging concept, geometry, and detector have unique properties such as signal-to-noise ratio, dynamic range, spatial resolution, distortions, and contrast. Some of these properties are inherently connected, particularly dynamic range and spatial resolution. It must be emphasized that spatial resolution is not a single number but must be seen in the context of dynamic range and consequently is better described by a function or distribution. We introduce the “dynamic granularity” G dyn as a standardized, objective relation between a detector’s spatial resolution (granularity) and dynamic range for complex imaging systems in a given environment rather than the widely found characterization of detectors such as cameras or films by themselves. We found that this relation can partly be explained through consideration of the signal’s photon statistics, background noise, and detector sensitivity, but a comprehensive description including some unpredictable data such as dust, damages, or an unknown spectral distribution will ultimately have to be based on measurements. Measured dynamic granularities can be objectively used to assess the limits of an imaging system’s performance including all contributing noise sources and to qualify the influence of alternative components within an imaging system. Our article explains the construction criteria to formulate a dynamic granularity and compares measured dynamic granularities for different detectors used in the X-ray backlighting scheme employed at Sandia’s Z-Backlighter facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The integrated optic RF spectrum analyzer

The results of measurements made on a fully integrated optic RF spectrum analyzer (IOSA) are reported. The performance of the device acousto-optic bandwidth, single-tone RF resolution, two-tone RF resolution, single-tone dynamic range, two-tone dynamic range, and single-tone RF response are presented. The device parameters that control device performance are analyzed. These results demonstrate the viability of the IOSA for real time spectrum analysis of pulsed and CW RF signals. Improvements of RF bandwidth resolution can be obtained by the use of larger collimated optical beams which requires larger optical lens elements, and hence, larger crystals.

Pedinoff, M. E.↗

Development Of Multilayer Metallic Mesh Low-Pass Infrared Filters

Prototype filters exhibit desired transmissivity vs. wavelength. Etched-metallic-film low-frequency-pass (long-wavelength-pass) filters with relatively sharp cut-on at wavelengths of 30 to 40 micrometers developed for use in infrared instruments. Filters particularly useful in observing astronomical bodies exhibiting wide temperature dynamic range. Reduction in signal dynamic range (due to temperature extremes) accomplished by blocking short-wavelength radiance by using low-pass metallic mesh filters.

Mobasser, Sohrab↗

Iterative-Transform Phase Retrieval Using Adaptive Diversity

A phase-diverse iterative-transform phase-retrieval algorithm enables high spatial-frequency, high-dynamic-range, image-based wavefront sensing. [The terms phase-diverse, phase retrieval, image-based, and wavefront sensing are defined in the first of the two immediately preceding articles, Broadband Phase Retrieval for Image-Based Wavefront Sensing (GSC-14899-1).] As described below, no prior phase-retrieval algorithm has offered both high dynamic range and the capability to recover high spatial-frequency components. Each of the previously developed image-based phase-retrieval techniques can be classified into one of two categories: iterative transform or parametric. Among the modifications of the original iterative-transform approach has been the introduction of a defocus diversity function (also defined in the cited companion article). Modifications of the original parametric approach have included minimizing alternative objective functions as well as implementing a variety of nonlinear optimization methods. The iterative-transform approach offers the advantage of ability to recover low, middle, and high spatial frequencies, but has disadvantage of having a limited dynamic range to one wavelength or less. In contrast, parametric phase retrieval offers the advantage of high dynamic range, but is poorly suited for recovering higher spatial frequency aberrations. The present phase-diverse iterative transform phase-retrieval algorithm offers both the high-spatial-frequency capability of the iterative-transform approach and the high dynamic range of parametric phase-recovery techniques. In implementation, this is a focus-diverse iterative-transform phaseretrieval algorithm that incorporates an adaptive diversity function, which makes it possible to avoid phase unwrapping while preserving high-spatial-frequency recovery. The algorithm includes an inner and an outer loop (see figure). An initial estimate of phase is used to start the algorithm on the inner loop, wherein multiple intensity images are processed, each using a different defocus value. The processing is done by an iterative-transform method, yielding individual phase estimates corresponding to each image of the defocus-diversity data set. These individual phase estimates are combined in a weighted average to form a new phase estimate, which serves as the initial phase estimate for either the next iteration of the iterative-transform method or, if the maximum number of iterations has been reached, for the next several steps, which constitute the outerloop portion of the algorithm. The details of the next several steps must be omitted here for the sake of brevity. The overall effect of these steps is to adaptively update the diversity defocus values according to recovery of global defocus in the phase estimate. Aberration recovery varies with differing amounts as the amount of diversity defocus is updated in each image; thus, feedback is incorporated into the recovery process. This process is iterated until the global defocus error is driven to zero during the recovery process. The amplitude of aberration may far exceed one wavelength after completion of the inner-loop portion of the algorithm, and the classical iterative transform method does not, by itself, enable recovery of multi-wavelength aberrations. Hence, in the absence of a means of off-loading the multi-wavelength portion of the aberration, the algorithm would produce a wrapped phase map. However, a special aberration-fitting procedure can be applied to the wrapped phase data to transfer at least some portion of the multi-wavelength aberration to the diversity function, wherein the data are treated as known phase values. In this way, a multiwavelength aberration can be recovered incrementally by successively applying the aberration-fitting procedure to intermediate wrapped phase maps. During recovery, as more of the aberration is transferred to the diversity function following successive iterations around the ter loop, the estimated phase ceases to wrap in places where the aberration values become incorporated as part of the diversity function. As a result, as the aberration content is transferred to the diversity function, the phase estimate resembles that of a reference flat.

Dean, Bruce H.↗

A water-based fast integrated mobility spectrometer (WFIMS) with enhanced dynamic size range

We developed a water-based fast integrated mobility spectrometer (WFIMS) with enhanced dynamic size range. The WFIMS builds on two established technologies: the fast integrated mobility spectrometer and laminar flow water-based condensation methodology. Inside WFIMS, particles of differing electrical mobility are separated in a drift tube and subsequently enlarged through water condensation. Particle size and concentration are measured via digital imaging at a frame rate of 10 Hz. When we measure particles of different mobilities simultaneously, the WFIMS resolves particle diameters ranging from 8 to 580 nm within 1 s or less. The performance of WFIMS was characterized with differential mobility analyzer (DMA) classified (NH 4 ) 2 SO 2 particles with diameters ranging from 8 to 265 nm. The mean particle diameters measured by WFIMS were found to be in excellent agreement with DMA centroid diameters. Furthermore, detection efficiency of WFIMS was characterized using a condensation particle counter as a reference and is nearly 100% for particles with diameter greater than 8 nm. In general, measured and simulated WFIMS mobility resolutions are in good agreement. But, some deviations are observed at low particle mobilities, likely due to the non-idealities of the WFIMS electric field.

54 ENVIRONMENTAL SCIENCES↗

Novel refractive index sensor based on fiber bragg grating in nano-bore optical fiber

In this paper, we propose a novel refractive index sensor with large dynamic range based on fiber Bragg grating in the nano-bore optical fiber. The spectral responses of grating on the filling index in the bore with different bore diameters and index ranges are numerically studied by the finite element method and coupled mode theory based transmission matrix method. It is found that the Bragg wavelength of grating is sensitive to the filling index in the bore. The influences of bore diameter on the wavelength sensitivity, resolution and dynamic range of the index sensor are analyzed. There exists a trade off between the linear dynamic range and sensitivity of index when the bore diameter varies. The optimized wavelength sensitivity and resolution of filling index are 53.6923 nm/index unit and 9.3123 × 10{sup −6} index under a linear index range of 1.0–1.4 using 2 µm bore diameter. The optimized linear dynamic range of index is 1.0–1.48 with wavelength sensitivity of 13.3056 nm/index unit and resolution of 3.7578 × 10{sup −5} index using 1 µm bore diameter. Our proposed index sensor has the technical advantages of simple all-fiber structure, large index range, and potential capability to synchronously detect index, temperature and strain.

36 MATERIALS SCIENCE↗

Engineering activatable promoters for scalable and multi-input CRISPRa/i circuits

Dynamic, multi-input gene regulatory networks (GRNs) are ubiquitous in nature. Multilayer CRISPR-based genetic circuits hold great promise for building GRNs akin to those found in naturally occurring biological systems. We develop an approach for creating high-performing activatable promoters that can be assembled into deep, wide, and multi-input CRISPR-activation and -interference (CRISPRa/i) GRNs. By integrating sequence-based design and in vivo screening, we engineer activatable promoters that achieve up to 1,000-fold dynamic range in an Escherichia coli-based cell-free system. These components enable CRISPRa GRNs that are six layers deep and four branches wide. We show the generalizability of the promoter engineering workflow by improving the dynamic range of the light-dependent EL222 optogenetic system from 6-fold to 34-fold. Additionally, high dynamic range promoters enable CRISPRa systems mediated by small molecules and protein–protein interactions. We apply these tools to build input-responsive CRISPRa/i GRNs, including feedback loops, logic gates, multilayer cascades, and dynamic pulse modulators. Our work provides a generalizable approach for the design of high dynamic range activatable promoters and enables classes of gene regulatory functions in cell-free systems.

42 ENGINEERING↗

Transient Negative Optical Nonlinearity of Indium Oxide Nanorod Arrays in the Full-Visible Range

Dynamic control of the optical response of materials at visible wavelengths is key to future metamaterials and photonic integrated circuits. Here we demonstrate large amplitude, negative optical nonlinearity (Δ n from -0.05 to -0.09) of indium oxide nanorod arrays in the full-visible range. We experimentally quantify and theoretically calculate the optical nonlinearity, which arises from the modifications of interband optical transitions. Furthermore, the approach towards negative optical nonlinearity can be generalized to other transparent semiconductors and opens door to reconfigurable, sub-wavelength optical components.

36 MATERIALS SCIENCE↗

Design of a digital beam attenuation system for computed tomography. Part II. Performance study and initial results

Purpose: The purpose of this work is to present a performance study of the digital beam attenuator (DBA) for implementing fluence field modulated CT (FFMCT) using a simulation framework developed to model the incorporation of the DBA into an existing CT system. Additionally, initial results will be presented using a prototype DBA and the realization of the prototype will be described. To our knowledge, this study represents the first experimental use of a device capable of modulating x-ray fluence as a function of fan angle using a CT geometry. Methods: To realize FFMCT, the authors propose to use a wedge design in which one wedge is held stationary and another wedge is moved over the stationary wedge. Due to the wedge shape, the composite thickness of the two wedges changes as a function of the amount of overlap between the wedges. This design allows for the wedges to modulate the photon fluence incident onto a patient. Using a simulation environment, the effect of changing the number of wedges has on dose, scatter, detector dynamic range, and noise uniformity is explored. Experimental results are presented using a prototype DBA having ten Fe wedges and a c-arm CT system geometry. The experimental DBA results are compared to non-DBA scans using scatter and detector dynamic range as metrics. Both flat field and bowtie filtered CT acquisitions were simulated for comparison with the DBA. Results: Numerical results suggest that substantial gains in noise uniformity and scatter-to-primary ratio (SPR) can be obtained using only seven wedges. After seven wedges, the decrease in noise ununiformity and SPR falls off at a lower rate. Simulations comparing CT acquisitions between flat field, bowtie enabled, and DBA CT acquisitions suggest DBA-FFMCT can reduce dose relative to flat field CT by Almost-Equal-To 3 times. A bowtie filter under the same imaging conditions was shown to only allow a dose reduction of 1.65 times. Experimentally, a 10 wedge DBA prototype result showed a SPR reduction of Almost-Equal-To 4 times relative to flat field CT. The dynamic range for the DBA prototype was 3.7 compared to 84.2 for the flat field scan. Conclusions: Based on the results presented in this paper and the companion paper [T. Szczykutowicz and C. Mistretta, 'Design of a digital beam attenuation system for computed tomography. Part I. System design and simulation framework,' Med. Phys. 40, 021905 (2013)], FFMCT implemented via the DBA device seems feasible and should result in both a dose reduction and an improvement in image quality as judged by noise uniformity and scatter reduction. In addition, the dynamic range reduction achievable using the DBA may allow photon counting imaging to become a clinical reality. This study may allow for yet another step to be taken in the field of patient specific dose modulation.

60 APPLIED LIFE SCIENCES↗

A Novel Concept for a Deformable Membrane Mirror for Correction of Large Amplitude Aberrations

Very large, light weight mirrors are being developed for applications in space. Due to launch mass and volume restrictions these mirrors will need to be much more flexible than traditional optics. The use of primary mirrors with these characteristics will lead to requirements for adaptive optics capable of correcting wave front errors with large amplitude relatively low spatial frequency aberrations. The use of low modulus membrane mirrors actuated with electrostatic attraction forces is a potential solution for this application. Several different electrostatic membrane mirrors are now available commercially. However, as the dynamic range requirement of the adaptive mirror is increased the separation distance between the membrane and the electrodes must increase to accommodate the required face sheet deformations. The actuation force applied to the mirror decreases inversely proportional to the square of the separation distance; thus for large dynamic ranges the voltage requirement can rapidly increase into the high voltage regime. Experimentation with mirrors operating in the KV range has shown that at the higher voltages a serious problem with electrostatic field cross coupling between actuators can occur. Voltage changes on individual actuators affect the voltage of other actuators making the system very difficult to control. A novel solution has been proposed that combines high voltage electrodes with mechanical actuation to overcome this problem. In this design an array of electrodes are mounted to a backing structure via light weight large dynamic range flextensional actuators. With this design the control input becomes the separation distance between the electrode and the mirror. The voltage on each of the actuators is set to a uniform relatively high voltage, thus the problem of cross talk between actuators is avoided and the favorable distributed load characteristic of electrostatic actuation is retained. Initial testing and modeling of this concept demonstrates that this is an attractive concept for increasing the dynamic range capability of electrostatic deformable mirrors.

Moore, Jim↗

Miniaturized Ion and Neutral Mass Spectrometer for CubeSat Atmospheric Measurements

To increase the number of single point in-situ measurements of thermosphere and exosphere ion and neutral composition and density, miniaturized instrumentation is in high demand to take advantage of the increasing platform opportunities available in the smallsat/cubesat industry. The INMS (Ion-Neutral Mass Spectrometer) addresses this need by providing simultaneous measurements of both the neutral and ion environment, essentially providing two instruments in one compact model. The 1.3U volume, 570 gram, 1.8W nominal power INMS instrument makes implementation into cubesat designs (3U and above) practical and feasible. With high dynamic range (0.1-500eV), mass dynamic range of 1-40amu, sharp time resolution (0.1s), and mass resolution of MdM16, the INMS instrument addresses the atmospheric science needs that otherwise would have required larger more expensive instrumentation. INMS-v1 (version 1) launched on Exocube (CalPoly 3U cubesat) in 2015 and INMS-v2 (version 2) is scheduled to launch on Dellingr (GSFC 6U cubesat) in 2017. New versions of INMS are currently being developed to increase and add measurement capabilities, while maintaining its smallsat/cubesat form.

science↗