Search NASA⌕ Search

SEARCH · Search NASA

Results for “electric resistance heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

The Colorado School of Mines Nevada geothermal study

Geothermal systems in the Basin and Range Province of the western United States probably differ in many respects from geothermal systems already discovered in other parts of the world because of the unique tectonic setting. To investigate this, a study of the geothermal occurrences at Fly Ranch, approximately 100 miles north of Reno, Nevada, has been undertaken. Ample evidence for a geothermal system exists in this area, including the surface expression of heat flow in the form of hot springs, an extensive area of low electrical resistivity, and a high level of seismicity along faults bounding the thermal area. However, geophysical and geological studies have not yet provided evidence for a local heat source at depth. Additional detailed geophysical and geological studies, as well as drilling, must be completed before the geothermal system can be described fully.

Keller, G. V.↗

Performance Modeling of a Thermoelectric Heat Pump Clothes Dryer with Very High Air Flow

Previous research has shown that a clothes dryer heated by thermoelectric (Peltier) heat pumps can be up to 85% more efficient than a conventional electric-resistance dryer. A previous thermoelectric prototype used a conventional dryer’s air flow of 120 ft3/min (0.06 m3/s) and provided about 1,300 W of thermoelectric heating capacity at a heating coefficient of performance (COP) of approximately 1.2. In this work, the performance of a clothes dryer with a very high air flow rate, up to 300 ft3/min (1.14 m3/s), and only 400 W of thermoelectric heating capacity was investigated using a thermohydraulic model. Key aspects of the model were validated experimentally. Results for dry time and efficiency are presented for various air flow and heating rates.

Boudreaux, Philip↗

Utilizing coal-derived solid carbon materials towards next-generation smart and multifunction pavements

This project focused on developing an eco-friendly, multifunctional pavement system, called Coal-Derived Carbon Enabled Smart Pavement (CDC-SP), using coal-derived materials. The system utilizes coal-derived pyrolyzed char as a key component to create electrically conductive asphalt concrete for smart pavements that offer self-heating, self-sensing, and self-healing capabilities. These functions are made possible by the conductive properties of coal-char, which enable Ohmic heating for snow and ice deicing, piezoresistivity for self-sensing, and induction heating for self-healing of cracks caused by stress or aging. The team successfully created CDC-SP samples with over 50% coal char composition, demonstrating desirable mechanical properties such as rutting resistance, moisture susceptibility, and cracking resistance. These samples also exhibited strong electrical and thermal conductivity, making them ideal for heating applications. Extensive tests confirmed the pavement’s effectiveness in melting ice and snow and maintaining durability under environmental conditions. The CDC-SP presents a promising approach to integrating U.S. domestic coal resources into infrastructure projects, providing environmental and economic benefits by enhancing pavement performance while utilizing low-cost coal-derived materials. Further research and compliance with industry standards are recommended before commercial scaling.

01 COAL, LIGNITE, AND PEAT↗

Physical properties of the layered $\mathcal{f}$-electron van der Waals magnet Ce 2 Te 5

Here. we report a detailed study of the magnetic, transport, and thermodynamic properties of Ce 2 Te 5 single crystals, a layered $\mathcal{f}$-electron van der Waals magnet. Four consecutive transitions at ~5.2, 2.1, 0.9, and 0.4 K were observed in the ac-plane electrical resistivity $\rho(T)$, which were further confirmed in specific heat $C_\text{p}(T)$ measurements. Analysis of the magnetic susceptibility $\chi(T)$, the magnetic-field variation of $\rho(T)$, and the increase of the first transition temperature ($T_c$ ~ 5.2 K) with applied magnetic field indicates ferromagnetic order, while the decrease of the other transitions with field suggests different states with dominant antiferromagnetic interactions below $T_2$ ~ 2.1 K, $T_3$ ~ 0.9 K, and $T_4$ = 0.4 K. Critical behavior analysis around Tc that gives critical exponents $\beta$ = 0.31(2), $\gamma$ = 0.99(2), $\delta$ = 4.46(1), and $T_c$ = 5.32(1) K indicates that Ce 2 Te 5 shows a three-dimensional magnetic critical behavior. Moreover, the Hall resistivity ρxy indicates that Ce2Te5 is a multiband system with a relatively high electron mobility ~2900 cm 2 V –1 s –1 near $T_c$, providing further opportunities for future device applications.

36 MATERIALS SCIENCE↗

Thermal modulation for gas chromatography

A thermal modulator device for gas chromatography and associated methods. The thermal modulator device includes a recirculating fluid cooling member, an electrically conductive capillary in direct thermal contact with the cooling member, and a power supply electrically coupled to the capillary and operable for controlled resistive heating of the capillary. The capillary can include more than one separate thermally modulated sections.

Hasselbrink, Ernest F.↗

Thermal modulation for gas chromatography

A thermal modulator device for gas chromatography and associated methods. The thermal modulator device includes a cooling member, an electrically conductive capillary in direct thermal contact with the cooling member, and a power supply electrically coupled to the capillary and operable for controlled resistive heating of the capillary.

Hasselbrink, Ernest F.↗

Nickel-Titanium Alloys: Corrosion "Proof" Alloys for Space Bearing, Components and Mechanism Applications

An intermetallic nickel-titanium alloy, 60NiTi (60wt%Ni, 40wt%Ti), is shown to be a promising candidate tribological material for space mechanisms. 60NiTi offers a broad combination of physical properties that make it unique among bearing materials. 60NiTi is hard, electrically conductive, highly corrosion resistant, readily machined prior to final heat treatment, and is non-magnetic. Despite its high titanium content, 60NiTi is non-galling even under dry sliding. No other bearing alloy, metallic or ceramic, encompasses all of these attributes. Since 60NiTi contains such a high proportion of titanium and possesses many metallic properties, it was expected to exhibit poor tribological performance typical of titanium alloys, namely galling type behavior and rapid lubricant degradation. In this poster-paper, the oil-lubricated behavior of 60NiTi is studied.

DellaCorte, Christopher↗

Nickel-Titanium Alloys: Corrosion "Proof" Alloys for Space Bearing, Components and Mechanism Applications

An intermetallic nickel-titanium alloy, 60NiTi (60 wt% Ni, 40 wt% Ti), is shown to be a promising candidate tribological material for space mechanisms. 60NiTi offers a broad combination of physical properties that make it unique among bearing materials. 60NiTi is hard, electrically conductive, highly corrosion resistant, readily machined prior to final heat treatment, and is non-magnetic. Despite its high Ti content, 60NiTi is non-galling even under dry sliding. No other bearing alloy, metallic or ceramic, encompasses all of these attributes. Since 60NiTi contains such a high proportion of Ti and possesses many metallic properties, it was expected to exhibit poor tribological performance typical of Ti alloys, namely galling type behavior and rapid lubricant degradation. In this poster-paper, the oil-lubricated behavior of 60NiTi is presented.

DellaCorte, Christopher↗

Design and Manufacturing Considerations for Shockproof and Corrosion-Immune Superelastic Nickel-Titanium Bearings for a Space Station Application

An intermetallic nickel-titanium alloy, 60NiTi (60wt%Ni, 40wt%Ti), is a promising tribological material for space mechanisms. 60NiTi offers a broad combination of physical properties that make it unique among bearing materials. 60NiTi is hard, electrically conductive, highly corrosion resistant, readily machined prior to final heat treatment, easily lubricated and is non-magnetic. It also falls within the class of superelastic alloys and can elastically endure large strains (beyond 5 percent) making it highly resistant to excessive and unexpected (shock) loads. Key material properties and characteristics such as elastic modulus, tensile fracture sensitivity and residual stress behavior, however, differ from conventional alloys such as steel and this significantly affects bearing design and manufacturing. In this paper, the preliminary design and manufacture of ball bearings made from 60NiTi are considered for a highly corrosive, lightly loaded, low speed bearing application found inside the International Space Station s water recycling system. The information presented is expected to help guide more widespread commercialization of this new technology into space mechanism and other applications.

DellaCorte, Christopher↗

Rapid-Rate Compression Testing of Sheet Materials at High Temperatures

This Report describes the test equipment that was developed and the procedures that were used to evaluate structural sheet-material compression properties at preselected constant strain rates and/or loads. Electrical self-resistance was used to achieve a rapid heating rate of 200 F/sec. Four materials were tested at maximum temperatures which ranged from 600 F for the aluminum alloy to 2000 F for the Ni-Cr-Co iron-base alloy. Tests at 0.1, 0.001, and 0.00001 in./in./sec showed that strain rate has a major effect on the measured strength, especially at the high temperatures. The tests, under conditions of constant temperature and constant compression stress, showed that creep deformation can be a critical factor even when the time involved is on the order of a few seconds or less. The theoretical and practical aspects of rapid-rate compression testing are presented, and suggestions are made regarding possible modifications of the equipment which would improve the over-all capabilities.

Bernett, E. C.↗

Experiments on thermoacoustic convection heat transfer in gravity and zero-gravity environments

The results of an experimental study of thermoacoustic convection (TAC) heat transfer in gravity and zero-gravity environments are presented. The experimental apparatus consisted of a cylinder containing air as the compressible fluid. The enclosed air was heated electrically at the top surface which consisted of a thin high-resistance steel foil connected to a power source. Thermocouples were used to measure the transient temperature of the air on the axis of the cylinder and the heated surface in the both zero-gravity and gravity environments. The zero-gravity tests were performed in the Zero-Gravity Drop Tower Facility of NASA-Lewis Research Center. The experimental results were corrected for the error due to radiation absorption by the thermocouples. A conduction-only numerical heat transfer model was developed to compute the transient air temperature in the cylindrical geometry. The results were compared to the experimental data to determine the significance of the thermoacoustic convection heat transfer mechanism. It is observed that the rate of heat transfer to the air measured during the experiments is consistently higher than that obtained by the conduction-only solution indicating a significant presence of the TAC heat transfer. Further experiments are planned to measure directly (1) the radiative heat transfer contribution to the rise in the air temperature, and (2) the air pressure oscillations within the cylinder that are responsible for the convective heat transfer mode.

Parang, Masood↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Superconductivity in WBe 2

WBe 2 , which occurs in space group 194, with hexagonal symmetry P6 3 /mmc, is prepared by arc-melting at temperatures above 2200 C, where Be vapor loss is significant. This study is motivated by recent work on MoB 2 and WB 2 , both superconductors (T c =32 and 17 K respectively) under high (∼70 GPa) pressure. In order to avoid the known Be-rich superconducting phases (WBe 13 and WBe 22 ) in the complex phase diagram, both known to be superconducting at 4.1 K, the sample was prepared with a slight (∼5 %) excess of W. The resultant sample, prepared using high purity (99.999 %) Be, is essentially single phase WBe 2 , with some spread in its superconducting properties due to the known homogeneity range. (WBe 2 forms in space group 194 between approximately W 1.02 Be 1.98 and W 0.88 Be 2.12 .) Characterization was carried out with x-ray diffraction, electrical resistivity, ρ, in zero and applied magnetic fields, and specific heat. The resistivity in zero and applied fields and specific heat data indicate that our sample of WBe 2 is a bulk superconductor at ambient pressure with a T c onset in ρ at 1.05 K, and T c (ρ→0) at ∼0.86 K. Furthermore, there is no signature of superconductivity in ρ at 4.1 K, indicating successful avoidance of WBe 13 and WBe 22 . The ρ data in field indicate an upper critical field of approximately 400 gauss.

Electrical transport↗

Fast-airflow tumble clothes dryer with small thermoelectric heat pump: Experimental evaluation

Residential clothes drying accounts for about 5% of the total residential-sector energy consumption in the United States. Most dryers use electric resistance heaters to dry clothes and have low efficiencies. Higher-efficiency dryers that use vapor compression heat pumps are expensive and complex and have not gained a large market share in the United States. A novel tumble clothes dryer using a small thermoelectric heat pump with faster airflow than typical dryers is presented in this work. The benchtop performance of the thermoelectric heat pump and high-speed blower are presented, and the development of the prototype dryer is described. The dryer was tested for efficiency and dry time for a range of airflow rates and applied currents to the thermoelectric heat pump. The combined efficiency factor was 5.09–6.29 lb BDW /kWh (specific moisture extraction rate of 1.23–1.53 kg w /kWh) with 100–138 min dry times for these tests. The measured efficiency was 36 %–68 % greater than the minimum efficiency standard in the United States, and compared with vapor compression heat pump–based clothes dryers, the prototype dryer had less expensive, less complex components and did not use refrigerants. Finally, the performance of this small thermoelectric heat pump clothes dryer is also compared with previous iterations of the thermoelectric tumble clothes dryer described in the literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrical and structural properties of VO 2 in an electric field

We examined the electrical and local structural properties of a VO 2 film at different electric fields using electrical resistance and x-ray absorption fine structure (XAFS) measurements at the V K edge in the temperature range of 30–100 °C. The T c value of the metal-to-insulator transition (MIT) during both heating and cooling decreases with electric field. When the electric field exceeds a certain value, the MIT becomes sharper due to Joule heating. Furthermore, the MIT, the structural phase transition (SPT), and the pre-edge peak transition of the VO 2 do not congruently occur at a uniform temperature. A metallic VO 2 is observed in only the rutile (or M2) symmetry. An electric field induces a substantial amount of conduction electrons in insulating VO 2 . Simultaneously measured resistance and XAFS reveal that Joule heating caused by an external electric field significantly affects the MIT and SPT of VO 2 .

36 MATERIALS SCIENCE↗

End-Use Savings Shapes: Measure Documentation: Add Exhaust Air Heat/Energy Recovery

This documentation focuses on a single end-use savings shape measure—Add Exhaust Air Heat/Energy Recovery. This measure adds exhaust air energy recovery or heat recovery to existing air handling units (AHU) with outdoor air. Systems that already have energy/heat recovery are not modified. Furthermore, food service building types are also not modified by this measure due to the added complication of integrating cooking hood exhaust that could cause heat exchanger fouling from kitchen exhaust. In total, this measure is applicable airloops serving ~70% of the floor area in ComStock. In practice, energy/heat recovery systems are retrofitted to existing air delivery systems either as separate systems that provide outdoor air to the AHUs or are directly integrated to an AHU; the modeling approach used in this study is agnostic of the energy recovery type and simply accounts recovery effectiveness, added static pressure, and other controls which are described further in this document. Energy recovery with sensible and latent exchange gets added in humid climate zones, while heat recovery with sensible-only exchange gets added in drier climate zones. Energy recovery is modeled as a fixed membrane plate counterflow heat exchanger, while heat recovery is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and electric resistance preheat coil for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Increasing the Number of Installed Residential Heat Pump Water Heaters in the USA Through Improved Technology and Utility Programs

Heat pump water heaters (HPWHs) offer an efficient alternative to electric resistance water heaters, but they suffer from limited market penetration. This paper reviews the current state of HPWHs in the USA, focusing on technology developments and programs to increase adoption. What technological improvements are needed to make HPWHs a good fit in more homes? Additionally, what are the best ways of promoting HPWHs to consumers? Improved communication and controls will allow HPWHs to provide demand response and follow dynamic utility rates. To enable fuel-switching, HPWHs are being developed that only need a standard 120V outlet. Split HPWHs can alleviate the cooling and noise that limit the use of HPWHs in small homes, multifamily buildings, and cold climates. Additionally, new utility programs aim to train installers and provide incentives to distributors to increase the number of HPWHs installed. Some utilities offer novel incentive programs that have led to increased customer uptake. Those advances, coupled with improved controls for load shifting and new products such as split HPWHs and HPWHs that can run on 120V power, may finally move the market forward.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Systematic over-estimation of lattice thermal conductivity in materials with electrically-resistive grain boundaries

Reducing the thermal conductivity κ of a material via nano-structuring to create small grain sizes is one of the most common strategies to improve thermoelectric materials. In such polycrystalline materials heat carrying phonons are scattered at the grain boundaries, which directly improves the thermoelectric quality factor and ultimately the figure-of-merit zT. In some cases, however, such as in Mg 3 Sb 2 , SnSe, and Mg 2 Si an opposite trend is found where higher lattice thermal conductivity reported in small grain polycrystalline material than in large grain or single crystal materials. This unphysical result indicates a problem with the conventional use of the Wiedemann–Franz law. Here, we trace this problematic finding to the electrical resistance at the grain boundaries, which leads to an overestimation of the phonon or lattice contribution of the thermal conductivity κ L . In materials with significant grain boundary electrical resistance, the estimated electronic contribution to the thermal conductivity LσT is low because the measured electrical conductivity σ is low. However within the grain electrons may still be transporting more heat than the total conductivity suggests, leading to an overestimation of κ L if the conventional κ L = κ – LσT is used with the measured values of κ and σ. Here, the overestimation of κL in small-grain samples is shown to be pervasive across a broad range of thermoelectric materials, including Mg 3 Sb 2 , Mg 2 Si, PbTe, PbSe, SnSe, (Hf,Zr)CoSb, CoSb 3 , and Bi 2 Te 3 alloys, and a correction is necessary to properly understand and predict their charge and heat transport.

36 MATERIALS SCIENCE↗