Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical connectivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

State Strategies for Valuing Distributed Energy Resources in Cost-Effective Locations

The deployment of Distributed Energy Resources (DERs), small-scale electricity generation sources or controllable loads connected to the distribution system or a facility served by the distribution system, can have wide-ranging and positive impacts for the electricity grid. Interconnecting a DER in a high-value location on the grid can unlock benefits beyond those that accrue to the off-taker or asset owner. When DERs are deployed optimally, not only can the individual consumer benefit, but the local utility, the electricity system, and other ratepayers can benefit as well. By engaging in locational DER planning, states can help protect their communities and ratepayers and can help ensure the reliability and resilience of the electricity system. This report explores states' role in better integrating locational value into DER siting and development. It first outlines some of the benefits that can be achieved through the deployment of DERs in high-value locations. It then looks at state policy and regulatory roles and the tools states can use to influence the location of DER development. The report next examines the challenges of locational DER planning, with a particular focus on the challenges that states face in influencing the location of DER development. It highlights three case studies from states that engaged in locational DER planning through the Multistate Initiative to Develop Solar in Locations that Provide Benefits to the Grid and then presents several lessons learned from these efforts. The final section of this report summarizes some recent publications related to locational value of DERs in the form of an abbreviated literature review.

14 SOLAR ENERGY↗

Cyber Protection of Grid-Connected Devices Through Embedded Online Security

Cybersecurity research regarding the electric power grid has primarily been focused on protecting the communication layer of grid-connected devices against cyber-attack threats. Although many developed methods have greatly reduced the effects of a cyber-attack on the vulnerabilities of grid-connected devices, discovering new vulnerabilities is inevitable and a constant threat. As a result, the overall reliability and security of network communications with regard to grid-connected devices is a concern. Here, this paper proposes a method that further secures a system by focusing on the control and hardware layer of grid-connected devices. The device’s controller firmware will be validated and authenticated using integrated device emulation resources prior to being activated to control the grid-connected device. This verification process is performed while the controller is online and actively controlling power flows related to the device. Therefore, an attack to the system through a malicious firmware patch would be detected by the online security and rejected while safely maintaining continuous and stable control of the device. This method integrates the concepts of firmware hot-patching, digital twins, and active monitoring into an overall cybersecurity protection system.

cybersecurity↗

The Uniform Methods Project: Smart Thermostat Evaluation Protocol

A smart thermostat is an internet-connected device that controls home heating, ventilation, and air-conditioning (HVAC) equipment and can automatically adjust temperature set points to optimize performance and achieve energy savings. Smart thermostat features often include two way communication, occupancy detection (such as geofencing and occupancy sensors), schedule learning, and seasonal optimization algorithms. Smart thermostats can control most conventional HVAC systems, including central air conditioners, heat pumps, and forced air furnaces. Several types of residential utility programs offer smart thermostats as replacements measures. Working with smart thermostat vendors, utilities can offer separate optimization programs to produce energy savings beyond those achieved by installing a smart thermostat. From an evaluation perspective, smart thermostat programs have several noteworthy features. First, the energy savings from a smart thermostat may change over the life of the device. As a smart thermostat is connected to the internet, original equipment manufacturers can update the thermostat software to improve the thermostat's energy efficiency. Likewise, users can adjust the thermostat settings and schedules over time in response to changes in weather, thermal comfort, energy prices, or preferences for energy efficiency. Additionally, many thermostat manufacturers offer seasonal optimization programs that recommend changes or make minor, automated adjustments to the thermostat settings to improve energy efficiency. These opt-in programs are now standard offerings for many smart thermostat manufacturers and provided at no additional cost to users. The potential for software updates and continuous optimization and the evolving nature of user interactions mean future energy savings may differ from first-year savings and the energy savings of smart thermostats may need to be evaluated more than once. Second, smart thermostats often have small unit energy savings relative to a home's total energy consumption, especially in comparison to whole- home retrofit programs. This can make it difficult to detect the smart thermostat savings in billing or advanced metering infrastructure (AMI) meter consumption data. For example, as cooling loads in many regions average about 20% of annual electricity consumption, smart thermostat savings of 10% of cooling energy use would equate to a 2% reduction in home electricity consumption. Evaluators should use regression analysis of whole-home billing consumption or advanced metering infrastructure (AMI) meter consumption data to evaluate smart thermostat savings because, as explained at greater length below , these data are usually available to evaluators and regression can control for the impacts of weather and other potentially confounding factors on a home's energy consumption. Finally, as with other energy efficiency programs, participation in smart thermostat programs is self-selective. As discussed at greater length below , smart thermostat participants tend to be, among other things, younger, higher-income, and more likely to adopt electric vehicles (EVs) and internet connected devices than nonparticipants. These differences are often unobservable to the evaluator and correlated with a home's energy consumption, creating the potential for bias in estimating savings. Due to the small unit savings of thermostats, errors and biases from self-selection that may not be very consequential when evaluating a whole- home retrofits (e.g., ±2% of home electricity consumption) can have a major impact when evaluating the savings and cost-effectiveness of smart thermostat programs. A percentage point change in the estimated savings could affect the cost-effectiveness of a program. This means it is important for evaluators to assess and to minimize the potential for error from selection bias in estimating smart thermostat program savings. The Uniform Methods Project provides model protocols for determining energy savings and demand reductions that result from specific energy efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol ; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The UMP protocols can be used by utilities, program administrators, public utility commissions, evaluators, and other stakeholders for both program planning and evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decay of Electrostatic Force of Dust Particles on Photovoltaic Modules

Photovoltaic (PV) energy yield loss due to solar module soiling has become increasingly important as solar module deployment is now at the hundreds of gigawatts scale and continues to grow rapidly. We have reported on direct measurements-using atomic force microscopy (AFM)-of strong electric-field-induced attraction and adhesion force (Fes) of dust particles onto solar panel that are 1 to 2 orders of magnitude stronger than the van der Waals and water capillary forces, corroborated by observing the increase in system voltage-induced soiling rate. Here, we report another characteristic of Fes on soiling-long lasting or slow decay after turning off the high voltage applied to solar panels. The Fes decay time varies in a wide time range of 1 to 10 hours, depending on two factors: 1) either/both the cell or/and particle were charged with high voltage before the voltages were turned off; and 2) how the cell was connected to the ground after the voltage was turned off-either connected through the power supply electronics, directly connected to the ground, or electrically floated. The Fes decay is understood in terms of 1) net electrical charge dissipations in both particle and cell, 2) thermal disordering of dipole polarization in the module glass dielectrics, and 3) charge redistribution by the electrostatic interaction of particle and module glass. This long-lasting Fes for hours can significantly affect the solar panel soiling after sunset, especially combined with water condensation.

14 SOLAR ENERGY↗

Environmental and economic optima of solar home systems design: A combined LCA and LCC approach

Here, we compare the economic and environmental optimal design of Solar Home Systems (SHSs) and explore the role of economic incentives (such as tariffs and technology costs) in approximating the two optima. To achieve that, we present a methodology for the environmental and economic evaluation of grid-connected SHSs: user-scale electric systems involving a photovoltaic (PV) power system and a battery energy storage system. The proposed methodology is based on a mixed integer linear programming (MILP) optimization, life cycle assessment and life cycle costing. This methodological framework is applied to a case study involving a typical SHS installation in Italy. The results of the environmental optimal design brought to the evaluation of a 3.25 kW PV assisted by 8.66 kWh of nickel cobalt manganese batteries, whereas the costs of the SHS are minimized by a small PV system (less than 1 kW). Results underline that the environmental optimal configurations rely on battery technologies, which entails a significant cost compared to the grid connection. In contrast, the economic optimal design solutions is less impactful than the grid mix both from an environmental and economic points of view. Thanks to a reduction of batteries and PV costs, the environmental impact of the economic optimal design is expected to decrease in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sizing Small-Scale Renewable Energy Systems for the Navajo Nation and Rural Communities

The Navajo Nation consists of about 55,000 residential homes spread across 27,000 square miles of trust land in the Southwest region of the United States. The Navajo Tribal Utility Authority (NTUA) reports that approximately 15,000 homes on the reservation do not have electricity due to the high costs of connecting rural homes located miles from utility distribution lines. In order to get these rural homeowners access electricity, NTUA and other Native owned companies are examining small-scale renewable energy systems to provide power for necessary usage such as lighting and refrigeration. The goal of this study is to evaluate the current renewable deployment efforts and provide additional considerations for photovoltaic (PV) systems that will optimize performance and improve efficiency to reduce costs. There are three case studies presented in different locations on the Navajo Nation with varying solar resource and energy load requirements. For each location, an assessment is completed that includes environmental parameters of the site- specific landscape and a system performance analysis of an off-grid residential PV system. The technical process, repeated for each location, demonstrates how the variance and uniqueness of each household can impact the system requirements after optimizations are applied. Therefore, the household variabilities and difference in locations must be considered. The differing results of each case study suggests additional analysis is needed for designing small-scale PV systems that takes a home-land-family specific approach to allow for better efficiency and more flexibility for future solar innovations to be considered for overall cost reductions.

14 SOLAR ENERGY↗

A spin-wave magnetometer with a positive feedback

In this work, we demonstrate experimentally the operation of a spin-wave magnetometer integrated into a circuit with a positive feedback. The circuit consists of the passive magnetic and active electric parts. The magnetic part includes a sensing element, which is a magnetic cross junction made of Y 3 Fe 2 (FeO 4 ) 3 . The electric part includes a non-linear amplifier and a phase shifter. The electric and magnetic parts are connected via micrometer size antennae. Spin waves are excited by two of these antennae while the output inductive voltage produced by the interfering spin waves is detected by the third antenna. Spin waves propagating in the orthogonal arms of the cross can accumulate significantly different phase shifts, depending on the direction and the strength of the external magnetic field. The output inductive voltage reaches its maximum in the case of constructive spin wave interference. The positive feedback provides further signal amplification. It appears possible to enhance the response function, compared to the passive circuits without a feedback, by a factor of ×100 without an increase in the noise level. The experimental data show a prominent response to the external magnetic field variation, exceeding 5 x 10 3 V/T. The intrinsic noise spectral density of the device can be as low as 10 -16 V 2 /Hz. The estimated sensitivity of the prototype device is 2 x 10 -12 T/√Hz at room temperature. We argue that spin-wave magnetometers can potentially be as sensitive as SQUIDs while operating at room temperature.

36 MATERIALS SCIENCE↗

Long-lasting strong electrostatic attraction and adhesion forces of dust particles on photovoltaic modules

Photovoltaic (PV) energy-yield loss due to solar module soiling has become increasingly important as solar module deployment is now at the hundreds of gigawatts scale and continues to grow rapidly. The electrostatic attraction and adhesion force (F es ) of dust particles by the high voltages from solar panels have been reported to be 1 to 2 orders of magnitude stronger than the van der Waals and water capillary forces, which has been corroborated by observing the increase in system voltage-induced soiling rate by setting up an outdoor test. Here, we report another characteristic of F es on soiling - long-lasting or slow decay after turning off the high voltage applied to solar panels. The F es decay time varies across a wide time range of 1 to 10 h, depending on two factors: 1) whether the cell, the particle, or both were charged with high voltage before the voltages were turned off; and 2) how the cell was connected to the ground after the voltage was turned off - either connected through the power-supply electronics, directly connected to the ground, or electrically floated. The Fes decay is understood in terms of 1) net electrical charge dissipations in both particle and cell, 2) thermal disordering of dipole polarization in the module glass dielectrics, and 3) charge redistribution by the electrostatic interaction of particle and module glass. This long-lasting F es for hours can affect the solar panel soiling after sunset, and it can have an even greater effect when combined with water condensation at night.

14 SOLAR ENERGY↗

Fine structure of current noise spectra in nanoelectromechanical resonators

Here, we study the frequency-dependent noise of a suspended carbon nanotube quantum dot nanoelectromechanical resonator induced by electron-vibration coupling. Using a rigorous Keldysh diagrammatic technique, we establish a formal framework connecting the vibrational properties to electrical measurements. We find that the noise power spectrum exhibits a narrow resonant peak at the frequency of the vibrational modes. However, this fine structure tends to disappear due to a coherent cancellation effect when the tunneling barriers are tuned to a symmetric point. Notably, measuring the electrical current noise spectra provides a sensitive alternative method for detecting the damping and dephasing of quantum vibrational modes.

Electric measurements↗

Open electrodes for in-plane field generation

An electrode film includes a first electrode pattern having a first set of parallel conductive electrodes and a second electrode pattern having a second set of parallel conductive electrodes disposed on a surface of a transparent film. The conductive electrodes in the first and second electrode patterns are conductive mesh patterns including a pattern of open areas and are arranged in an interlaced pattern. The first and second electrode patterns are configured to be connected to respective sources of electrical power supplying respective waveforms to generate a time-varying electric field pattern above a surface of the electrode film.

42 ENGINEERING↗

WIP: Collaborating to Introduce Second-Life Battery Technology Research in an Informal STEM Learning Environment

This work in progress, innovative practice, paper outlines an interdisciplinary collaborative model utilized by a team of educational researchers, and engineers to design a series of community-centered, place-based learning activities suitable for a middle or high school informal STEM learning environment. Based on the potential applications and benefits of Second-Life Electric Vehicle Batteries, the activities connect cutting-edge STEM research with multidimensional real-world challenges within their communities related to climate change, renewable energy integration and storage, intelligent transportation systems, and optimized energy management, that empowers students to think critically about the role they can play in shaping a more resilient, environmentally sustainable community.

Whiteside, Hope↗

Multiscale electric-field imaging of polarization vortex structures in PbTiO 3 /SrTiO 3 superlattices

In ferroelectric heterostructures, the interaction between intrinsic polarization and the electric field generates a rich set of localized electrical properties. The local electric field is determined by several connected factors, including the charge distribution of individual unit cells, the interfacial electromechanical boundary conditions, and chemical composition of the interfaces. However, especially in ferroelectric perovskites, a complete description of the local electric field across micro-, nano-, and atomic-length scales is missing. Here, by applying four-dimensional scanning transmission electron microscopy (4D STEM) with multiple probe sizes matching the size of structural features, we directly image the electric field of polarization vortices in (PbTiO 3 ) 16 /(SrTiO 3 ) 16 superlattices and reveal different electric field configurations corresponding to the atomic scale electronic ordering and the nanoscale boundary conditions. The separability of two different fields probed by 4D STEM offers the possibility to reveal how each contributes to the electronic properties of the film.

36 MATERIALS SCIENCE↗

Cost and Performance Baseline for Fossil Energy Plants – Volume 1: Bituminous Coal and Natural Gas to Electricity: May 2025

This presentation at EPRI's annual Generation Sector Meeting during the Advanced Generation and Carbon Capture and Storage session provides an overview of the recently published Cost and Performance Baseline for Fossil Energy Plants – Volume 1: Bituminous Coal and Natural Gas to Electricity dated May 2025. It further connects viewers with the recently released tool/dashboard, an interactive tool that allows users to manipulate six key study parameters simultaneously for each case and visualize the impact on three metrics: 1) levelized cost of electricity (LCOE), 2) cost of CO2 captured (CCC), and 3) cost of CO2 avoided (CCA).

baseline study↗

Operating Strategies for Dispatchable PEM Electrolyzers that Enable Low-Cost Hydrogen Production

Hydrogen is a pathway to enabling decarbonization across multiple economic sectors that cannot be directly decarbonized with electricity including heat for industrial operations, medium- and heavy-duty transportation applications, long-duration energy storage, and as a feedstock for chemical synthesis. Producing hydrogen at low costs and carbon footprint is likely essential to economically decarbonize these otherwise "hard to decarbonize" sectors. Low-temperature polymer electrolyte membrane (PEM) electrolysis produces hydrogen from water and electricity and is a rapidly developing pathway towards making hydrogen at the scales required for decarbonization applications. The levelized cost of electrolytic hydrogen is dependent on the capital cost, efficiency, and durability of the electrolyzer system as well as the price of electricity supplied to the electrolyzer and the annual utilization of the electrolyzer (capacity factor). Electricity price and capacity factor depend on the source of energy that the system uses and impact other economic factors. Electricity price and capacity factor and the connections between other aspects of hydrogen production via PEM electrolyzers are the focus of this work. PEM electrolyzers have conventionally been operated at high capacity factors using electricity purchased from utilities with a constant price throughout the year. To achieve lower effective electricity prices, recent work has investigated opportunities for electrolyzers to purchase electricity in wholesale markets, where the cost of electricity varies hourly. This option can lead to lower electricity costs when the electrolyzer is a controllable load that ramps up and down rapidly and turns on and off frequently. This configuration and operating strategy capitalizes on times of low wholesale electricity prices and results in lower hydrogen levelized costs than constant operation due to reduced electricity costs even though the reduced capacity factor increases the cost of recovering the capital investment. Cycling on and off frequently also has implications for electrolyzer durability. An electrolyzer configuration where it is directly connected to renewable generation such as wind or solar, only running when the generator is producing energy, has similar implications on operating strategy, hydrogen levelized cost, capacity factor, and durability. This work provides insight into the relationships between dispatchable electrolyzer operating strategies and the cost of producing hydrogen from these systems, outlining strategies and opportunities to minimize production costs while minimizing operations that are likely to negatively impact system durability and efficiency. We find strategies that minimize electrolyzer cycling and the resulting durability impacts while increasing the hydrogen levelized cost only slightly above the minimum. We also find opportunities for batteries to minimize the number of cycles in systems directly connected to renewable generation. These findings outline key opportunities for future electrolyzer deployments and the synergistic benefits between electrolyzers and increased deployment of renewable energy generation like wind and solar. They also inform research and development that is reducing electrolyzer capital cost while managing durability impacts.

electricity markets↗

We Just Want to Pump…You Up! Forecasting Grid-Connected Heat Pump Water Heater Energy Savings and Load Shifting Potential for the Southeast U.S.

Heat pump water heaters (HPWH) can achieve energy savings of 60-70% compared to conventional electric-resistance water heaters. However, even with a favorable simple payback period within the typical product lifetime, HPWHs make up only 1% of all electric water heaters sold in the residential sector. Market adoption is challenged, in part, by the lack of effective energy efficiency programs in the U.S. region with the greatest amount of residential electric water heaters. The recent integration of connected functionality into HPWHs offers the capability to shift load without undue negative impact on customers. This capability can provide value to utilities with peak load constraints, motivating them to promote HPWHs for the first time. This paper will present a methodology to forecast connected HPWH energy use and extrapolate load shifting potential for the Southeast U.S. region. The methodology leverages data from a robust connected HPWH field study conducted in the Pacific Northwest. A coefficient of performance (COP) relationship for HPWHs was developed using ambient and inlet water temperature data to forecast HPWH performance on a month-by-month basis. Using the forecasted COP, HPWH operating hours were calculated for meeting load, which serve as the proxy to extrapolate load shifting potential from the Pacific Northwest to the Southeast. As a use case, analytical results are presented for a specific utility. This methodology, in combination with market analysis, facilitates the development of customized energy savings and load shifting forecasts to understand the potential impacts of launching connected HPWH programs in specific utility service territories.

heat pump water heater, energy savings, load shift↗

If One GEB is Good, a Community of GEBs is Better

Energy efficient, connected, grid-interactive, smart and flexible buildings are key to decarbonization, lowering energy use and improving the nation’s electricity grid. The U.S. Department of Energy’s Connected Communities initiative works to demonstrate how coordinated groups of highly efficient buildings combined with other distributed energy resources (DERs), such as electric vehicle (EV) charging, batteries, storage, demand response and photovoltaic (PV) generation can reliably and cost-effectively serve as grid assets by strategically deploying efficiency and demand flexibility while reducing carbon emissions. In 2021, DOE competitively awarded $61 million to a diverse portfolio of 10 pilot projects to promote grid-interactive efficient buildings (GEBs) working together to reliably and cost-effectively serve as grid assets while decarbonizing. Two of the main tenets of the program are measuring the communities’ energy and carbon performance and understanding how to replicate project successes in other communities. This paper begins with a discussion of what Connected Communities are (including a brief history) and their many benefits, including reduced carbon emissions and increased building efficiency and demand flexibility. Next, it provides an overview of the 10 projects, highlighting the diversity of approaches to measure success and replicate the projects: geographic locations; building types; utility, regulatory, market environments; and building vintages that will be used to test the ability of buildings to serve as grid resources. It concludes with a discussion of anticipated project impacts and the metrics that will be used to evaluate the Connected Communities projects.

Nemtzow, David↗

A Decision Support Framework for Grid-Aware Electric Bus Charge Scheduling

While there are many advantages to electric public transit vehicles, they also pose new challenges for fleet operators. One key challenge is defining a charge scheduling policy that minimizes operating costs and power grid disruptions while maintaining schedule adherence. An uncoordinated policy could result in some buses running out of charge before completing their trip, while a grid agnostic policy might incur higher energy costs or cause an adverse impact on the grid’s distribution system. We present a grid aware decision-theoretic framework for electric bus charge scheduling that accounts for energy price, grid load, and bus status. The framework connects environmental models for traffic (SUMO) and the electric grid (GridLAB-D) to a planner, which evaluates bus charging decisions with regard to their long-term effect on grid reliability and cost. The framework has been evaluated on a simulation of Richland, WA’s bus and grid network, and compared to greedy methods.

EV, machine leaning, EV-Grid, Transportation, Grid↗