Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrode aging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

230 records · Page 13

Capacity and Coulombic Efficiency Measurements Underestimate the Rate of SEI Growth in Silicon Anodes

Capacity measurements and related quantities are the first layer of information acquired during testing of Li-ion cells. It is generally considered that elevated values of coulombic efficiency and capacity retention are absolute indicators of the existence of a stable solid electrolyte interphase (SEI). Here, we challenge this notion by analyzing how the effect of side reactions on cell capacity depends on the choice of electrodes. More specifically, we demonstrate that the extent of measurable capacity fade due to SEI growth is modulated by the shape of the voltage profile of the cathode and anode at the end of charge and discharge half-cycles. This shape-dependency creates a mismatch between SEI growth and cell capacity loss, which is relatively small for graphite anodes but sizable for silicon-containing electrodes. We illustrate this point by showing that, at the same coulombic efficiency and capacity retention, cells containing silicon-based materials could actually exhibit rates of SEI growth that are as much as ≥ 40% higher than graphite cells. The main implication of this behavior is that, for certain systems, capacity measurements may be an unreliable source of information about the extent of reactions at the SEI, allowing other consequences of these side reactions (such as electrolyte depletion) to proceed unchecked while the cell appears to be stable.

25 ENERGY STORAGE↗

OLED Fundamentals: Materials, Devices, and Processing of Organic Light-Emitting Diodes

What is an organic light emitting diode (OLED)? Why should we care? What are they made of? How are they made? What are the challenges in seeing these devices enter the marketplace in various applications? These are the questions we hope to answer in this book, at a level suitable for knowledgeable non-experts, graduate students and scientists and engineers working in the field who want to understand the broader context of their work. At the most basic level, an OLED is a promising new technology composed of some organic material sandwiched between two electrodes. When current is passed through the device, light is emitted. The stack of layers can be very thin and has many variations, including flexible and/or transparent. The organic material can be polymeric or composed small molecules, and may include inorganic components. The electrodes may consist of metals, metal oxides, carbon nanomaterials, or other species, though of course for light to be emitted, one electrode must be transparent. OLEDs may be fabricated on glass, metal foils, or polymer sheets (though polymeric substrates must be modified to protect the organic material from moisture or oxygen). In any event, the organic material must be protected from moisture during storage and operation. A control circuit, the exact nature of which depends on the application, drives the OLED. Nevertheless, the control circuit should have very stable current control to generate uniform light emission. OLEDs can be designed to emit a single color of light, white light, or even tunable colors. The devices can be switched on and off very rapidly, which makes them suitable for displays or for general lighting. Given the amazing complexity of the technical and design challenges for practical OLED applications, it is not surprising that applications are still somewhat limited. Although organic electroluminescence is more than 50 years old, the modern OLED field is really only about half that age – with the first high-efficiency OLED demonstrated in 1987. Thus, we expect to see exciting advances in the science, technology and commercialization in the coming years. We hope that this book helps to advance the field in some small way. Contributors to this monograph are experts from top academic institutions, industry and national laboratories who provide comprehensive and up-to-date coverage of the rapidly evolving field of OLEDs. Furthermore, this monograph collects in one place, for the first time, key topics across the field of OLEDs, from fundamental chemistry and physics, to practical materials science and engineering topics, to aspects of design and manufacturing. The monograph synthesizes and puts into context information scattered throughout the literature for easy review in one book. The scope of the monograph reflects the necessity to focus on new technological challenges brought about by the transition to manufacturing. In the Section 1, all materials of construction of the OLED device are covered, from substrate to encapsulation. In Section 2, for the first time, additional challenges in devices and processing are addressed. This book is geared towards a broad audience, including materials scientists, device physicists, synthetic chemists and electrical engineers. Furthermore, this book makes a great introduction to scientists in industry and academia, as well as graduate students interested in applied aspects of photophysics and electrochemistry in organic thin films. This book is a comprehensive source for OLED R&D professionals from all backgrounds and institutions.

OLED↗

Voltage-Based Strategies for Preventing Battery Degradation under Diverse Fast-Charging Conditions

Maintaining safe operating conditions is a key challenge for high-performance lithium-ion battery applications. The lithium-plating reaction remains a risk during charging, but limited studies consider the highly variable charging conditions possible in commercial cells. Here we combine pseudo-2D electrochemical modeling with data visualization methods to reveal important relationships between the measurable cell voltage and difficult-to-predict Li-plating onset criteria. An extensively validated model is used to compute Li plating for thousands of multistep charging conditions spanning diverse rates, temperatures, states-of-charge, and cell aging. Here we observe an empirical cell operating voltage limit below which plating does not occur across all conditions, and this limit varies with the battery state-of-charge and aging. A model sensitivity analysis also indicates that, when comparing two charging voltage profiles, the capacity difference at 4.0 V correlates well with the difference in the plating onset capacity. These results encourage simple strategies for Li-plating prevention that are complementary to existing battery controls.

25 ENERGY STORAGE↗

Graphene Oxide Interlayers for Robust, High-Efficiency Organic Photovoltaics

Organic photovoltaic (OPV) materials have recently garnered significant attention as enablers of high power conversion efficiency (PCE), low-cost, mechanically flexible solar cells. Nevertheless, further understanding-based materials developments will be required to achieve full commercial viability. In particular, the performance and durability of many current generation OPVs are limited by poorly understood interfacial phenomena. Careful analysis of typical OPV architectures reveals that the standard electron-blocking layer, poly-3,4-ethylenedioxy-thiophene:poly(styrene sulfonate) (PEDOT:PSS), is likely a major factor limiting the device durability and possibly performance. Here we report that a single layer of electronically tuned graphene oxide is an effective replacement for PEDOT:PSS and that it significantly enhances device durability while concurrently templating a performance-optimal active layer {pi}-stacked face-on microstructure. Such OPVs based on graphene oxide exhibit PCEs as high as 7.5% while providing a 5x enhancement in thermal aging lifetime and a 20x enhancement in humid ambient lifetime versus analogous PEDOT:PSS-based devices.

14 SOLAR ENERGY↗

Electroencephalogram (EEG) and Magnetoencephalogram (MEG) as Tools for Evaluation of Cognitive Function

We have developed computerized analysis and display techniques to help identify the origins of visually evoked scalped potentials (VESP). The potentials are recorded simultaneously from many electrodes (usually 40 to 48) spaced over the region of the scalp where appreciable evoked potentials are found in response to particular stimulus. Contour mapping algorithms are then used to display the time behavior of equipotential surfaces on the scalp during the VESP. We then use an optimization technique to select the parameters of arrays of current dipole sources within the model until the model equipotential field distribution closely fits the measured data. Computer graphics are then used to display, as a movie, the actual and model scalp potential fields and the parameters of the dipole generators within the model head during the course of VESP activity. We have devised reaction time tests that involve potentially separable stages of cognitive processing and utilize stimuli that produce measurable cognition-related features in the late component of the evoked potential. We have used these techniques to determine the loci in the brain where known cognition-related features in the evoked potential are generated and we have explored the extent to which each of these features can be related to the reaction time tasks. We have also examined the temporal-spatial aspects of their cerebral involvement. Our current work is planned to characterize the age-related changes in the processes performed by such sources. We also use a neuromagnetometer to measure the evoked magnetic fields in similar circumstances; we will discuss the relative merits of the two methodologies.

Fender, Derek H.↗

Integrating Carbon Nanomaterials with Metals for Bio-sensing Applications

Age structure in most developed countries is changing fast as the average lifespan is increasing significantly, calling for solutions to provide improved treatments for age-related neurological diseases and disorders. In order to address these problems, a reliable way of recording information about neurotransmitters from in vitro and in vivo applications is needed to better understand neurological diseases and disorders as well as currently used treatments. Likewise, recent developments in medicine, especially with the opioid crisis, are demanding a swift move to personalized medicine to administer patient needs rather than population-wide averages. In order to enable the so-called personalized medicine, it is necessary to be able to do measurements in vivo and in real time. These actions require sensitive and selective detection of different analytes from very demanding environments. Current state-of-the-art materials are unable to provide sensitive and selective detection of neurotransmitters as well as the required time resolution needed for drug molecules at a reasonable cost. To meet these challenges, we have utilized different metals to grow carbon nanomaterials and applied them for sensing applications showing that there are clear differences in their electrochemical properties based on the selected catalyst metal. Additionally, we have combined atomistic simulations to support optimizing materials for experiments and to gain further understanding of the atomistic level reactions between different analytes and the sensor surface. With carbon nanostructures grown from Ni and Al + Co + Fe hybrid, we can detect dopamine, ascorbic acid, and uric acid simultaneously. On the other hand, nanostructures grown from platinum provide a feasible platform for detection of H 2 O 2 making them suitable candidates for enzymatic biosensors for detection of glutamate, for example. Tetrahedral amorphous carbon electrodes have an ability to detect morphine, paracetamol, tramadol, and O-desmethyltramadol. With carbon nanomaterial-based sensors, it is possible to reach metal-like properties in sensing applications using only a fraction of the metal as seed for the material growth. We have also seen that by using nanodiamonds as growth catalyst for carbon nanofibers, it is not possible to detect dopamine and ascorbic acid simultaneously, although the morphology of the resulting nanofibers is similar to the ones grown using Ni. This further indicates the importance of the metal selection for specific applications. However, Ni as a continuous layer or as separate islands does not provide adequate performance. Thus, it appears that metal nanoparticles combined with fiber-like morphology are needed for optimized sensor performance for neurotransmitter detection. This opens up a new research approach of application-specific nanomaterials, where carefully selected metals are integrated with carbon nanomaterials to match the needs of the sensing application in question.

59 BASIC BIOLOGICAL SCIENCES↗

Dimolybdenum Paddlewheel Complexes with Cation Binding Sites as Electrolyte Additives to Manipulate the Solid-Electrolyte Interphase at Lithium Metal Anodes

The use of electrolyte additives at millimolar loadings to control the surface chemistry of lithium metal anodes (LMAs) is a leading strategy to improve lithium metal batteries and promote electrosynthetic reactions. Whereas previous studies employed either inorganic or organic additives, in this study, we report the first organometallic additive, Mo 2 (mea) 4 [1, mea = 2-(2-methoxyethoxy)acetate], a dimolybdenum paddlewheel complex that is stable under Li plating conditions and features cation binding sites in the second coordination sphere that promote reversible Li + coordination. Binding of Li + ions to 1 induces immobilization of cationically charged aggregates (or products thereof) into the solid electrolyte interphase (SEI), imparting multiple beneficial functions. The modified SEI was found to protect the LMA against parasitic side reactions, produce modest but measurable improvements to Li plating properties (e.g., overpotential, surface structure, and Coulombic efficiency), and improve interfacial charge transport properties. Furthermore, the most notable benefit to battery cycling performance appears in calendar aging tests, which show that the presence of the additive protects the LMA from parasitic side reactions that would otherwise decrease overall cell cycling efficiency over time. Collectively, these data disclose a tactic for designing electrolyte additives using principles of organometallic synthesis.

Additives↗

Uncovering the Relationship between Aging and Cycling on Lithium Metal Battery Self-Discharge

Lithium metal is considered the “holy grail” material to replace typical Li-ion anodes due to the absence of a host structure coupled with a high theoretical capacity. The absence of a host structure results in large volumetric changes when lithium is electrodeposited/dissolved, making the lithium prone to stranding and parasitic reactions with the electrolyte. Lithium research is focused on enabling highly reversible lithium electrodeposition/dissolution, which is important to achieving long cycle life. Understanding the various mechanisms of self-discharge is also critical for realizing practical lithium metal batteries but is often overlooked. In contrast to previous work, it is shown here that self-discharge via galvanic corrosion is negligible, particularly when lithium is cycled to relevant capacities. Rather, the continued electrochemical cycling of lithium metal results in self-discharge when periodic rest is applied during cycling. The extent of self-discharge can be controlled by increasing the capacity of plated lithium, tuning electrolyte chemistry, incorporating regular rest, or introducing lithiophilic materials. Finally, the Coulombic losses that occur during periodic rest are largely reversible, suggesting that the dominant self-discharge mechanism in this work is not an irreversible chemical process but rather a morphological process.

25 ENERGY STORAGE↗

Alternating-pulse iontophoresis for targeted cutaneous anesthesia

In studies of sensory contributions to motor control, it may be advantageous to temporarily reduce the sensitivity of specific sensory systems. This article details a method for non-invasively inducing cutaneous anesthesia, leaving proprioceptive and motor functions intact. This method, called alternating-pulse iontophoresis, differs from conventional direct-current (DC) iontophoretic drug delivery in that adjacent drug delivery electrodes are stimulated out-of-phase. The total current delivered at any instant is then less than that produced during a comparable DC application, while the uniformity of drug delivery is expected to improve. Effective delivery of local anesthetics to the cutaneous foot soles by alternating-pulse iontophoresis was demonstrated using cutaneous pressure sensory threshold levels (STL's) assessed with Semmes-Weinstein monofilaments (arbitrary units of perceived force, or a.u.). Thirteen of 16 healthy subjects achieved a level of anesthesia greater than or equal to that normally associated with clinical peripheral sensory neuropathy. Average STL's measured prior to the anesthesia procedure were 4.00 a.u. ( approximately 10 mN). Immediately following the procedure, STL's were elevated to an average of 5.40 a.u. ( approximately 246 mN) and averaged 4.97 a.u. ( approximately 92 mN) after 50 min of standing. A number of research and clinical applications for this technique are suggested.

Non-NASA Center↗

Anodic Interfacial Evolution in Extremely Fast Charged Lithium-Ion Batteries

Interfacial reaction mechanisms at the anode/separator interface play a central role in the performance and safety of lithium-ion batteries during fast charging. We report a mechanistic study on the evolution and interactions of the aging mechanisms at the anode/separator interface in lithium cobalt oxide/graphite pouch cells charged with variable charging rates (1–6C) over 10 cycles. In situ electrochemical measurements, including voltage relaxation, Coulombic efficiency, and direct current internal resistance, indicated an incremental lithium loss until the C rates were ≤5C. A substantial capacity fade is observed in the first few cycles of fast charging, but the magnitude of capacity fade progressively diminishes with the number of cycles, indicating a suppression in the lithium deposition mechanism. Post-mortem film thickness, X-ray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM) analyses were performed to elucidate the evolution of electrolyte decomposition, the solid–electrolyte interface (SEI), lithium plating, and film fracture mechanisms with C rate. XPS measurements confirmed an increasing lithium concentration in an SEI film with an increase in the C rate. SEM images showed a growth of dendritic lithium on the anode surface from 1C to 3C. Precrack formation leading to an interfacial film fracture was observed at higher C rates. Furthermore, a differential analysis of the discharge capacity indicated a possible two-phase delithiation from the anode and reduced cathodic lithiation due to lithium loss at high C rates.

36 MATERIALS SCIENCE↗

Measurement of nutritional status in simulated microgravity by bioelectrical impedance spectroscopy

The potential of bioelectrical impedance spectroscopy (BIS) for assessing nutritional status in spaceflight was tested in two head-down-tilt bed-rest studies. BIS-predicted extracellular water (ECW), intracellular water (ICW), and total body water (TBW) measured using knee-elbow electrode placement were compared with deuterium and bromide dilution (DIL) volumes in healthy, 19- to 45-yr-old subjects. BIS was accurate during 44 h of head-down tilt with mean differences (BIS - DIL) of 0-0.1 kg for ECW, 0.3-0.5 for ICW, and 0.4-0.6 kg for TBW (n = 28). At 44 h, BIS followed the within-individual change in body water compartments with a relative prediction error (standard error of the estimate/baseline volume) of 2.0-3.6% of water space. In the second study, BIS did not detect an acute decrease (-1.41 +/- 0.91 kg) in ICW secondary to 48 h of a protein-free, 800 kcal/day diet (n = 18). BIS's insensitivity to ICW losses may be because they were predominantly (65%) localized to the trunk and/or because there was a general failure of BIS to measure ICW independently of ECW and TBW. BIS may have potential for measuring nutritional status during spaceflight, but its limitations in precision and insensitivity to acute ICW changes warrant further validation studies.

Non-NASA Center↗

Influence of Electrolyte Additives on Interfacial Stability of Manganese-Rich Lithium-Ion Battery Cathodes

Affordable, long-lasting energy storage has become critical to support increased electricity demand in recent years. Cobalt-free, lithium- and manganese-rich lithium nickel manganese oxide (LMR-NM) cathodes stand to reduce cost and supply-chain concerns associated with traditional cobalt-containing cathodes for lithium-ion batteries by leveraging more earth-abundant materials; however, they have shown issues with long-term cycling stability. Here, we investigate lithium difluoro(oxalate)borate (LiDFOB), tris(trimethylsilyl) phosphite (TMSPi), and vinylene carbonate (VC) electrolyte additives for their ability to improve cycling performance of LMR-NM (0.3 Li 2 MnO 3 + 0.7 LiMn 0.5 Ni 0.5 0 2 ) cells. Cryogenic scanning transmission electron microscopy (cryo-STEM) with electron energy loss spectroscopy enables the construction of a structure–function relationship between cathode electrolyte interphase (CEI) characteristics and the electrochemical performance of cells aged with these additives. We find the combination of 2 wt % TMSPi + 1 wt % LiDFOB performs better than any single additive, achieving a 28% improvement in specific capacity over the baseline electrolyte after long-term cycling. We attribute this to LiDFOB mitigating Mn ion dissolution, with cryo-STEM showing Mn stabilized up to the CEI surface, coupled with improved CEI structure and chemistry enabled by TMSPi, evidenced by a moderately thick (∼7–15 nm) CEI that appears to protect against further electrolyte reactions with the particle. These results, achieved through site-specific nanoscale characterization, directly reveal mechanisms through which electrolyte engineering can improve the performance of earth-abundant cathodes, enabling informed development of more affordable and reliable batteries to meet future energy storage needs.

25 ENERGY STORAGE↗

The Origin of Improved Performance in Boron‐Alloyed Silicon Nanoparticle‐Based Anodes for Lithium‐Ion Batteries

Stabilizing the solid electrolyte interphase (SEI) remains a key challenge for silicon‐based lithium‐ion battery anodes. Alloying silicon with secondary elements like boron has emerged as a promising strategy to improve the cycle life of silicon anodes, yet the underlying mechanism remains unclear. To address this knowledge gap, how boron concentration influences battery performance is systematically investigated. These results show a near‐monotonic increase in cycle lifetime with higher boron content, with boron‐rich electrodes significantly outperforming pure silicon. Additionally, silicon‐boron alloy anodes exhibit nearly three times longer calendar life than pure silicon. Through detailed mechanistic analysis, alternative contributing factors are systematically ruled out, and it is proposed that improved passivation arises from a strong permanent dipole at the nanoparticle surface. This dipole, formed by undercoordinated and highly Lewis acidic boron, creates a static, ion‐dense layer that stabilizes the electrochemical interface, reducing parasitic electrolyte decomposition and enhancing long‐term stability. These findings suggest that, within the SEI framework, the electric double layer is an important consideration in surface passivation. This insight provides an underexplored parameter space for optimizing silicon anodes in next‐generation lithium‐ion batteries.

25 ENERGY STORAGE↗

Applying Space Technology to Enhance Control of an Artificial Arm for Children and Adults With Amputations

The first single function myoelectric prosthetic hand was introduced in the 1960's. This hand was controlled by the electric fields generated by muscle contractions in the residual limb of the amputee user. Electrodes and amplifiers, embedded in the prosthetic socket, measured these electric fields across the skin, which increase in amplitude as the individual contracts their muscle. When the myoelectric signal reached a certain threshold amplitude, the control unit activated a motor which opened or closed a hand-like prosthetic terminal device with a pincher grip. Late in the 1990's, little has changed. Most current myoelectric prostheses still operate in this same, single-function way. To better understand the limitations of the current single-function myoelectric hand and the needs of those who use them, The Institute for Rehabilitation and Research (TIRR), sponsored by the National Institutes of Health (NUH), surveyed approximately 2,500 individuals with upper limb loss [1]. When asked to identify specific features of their current myoelectric prostheses that needed improvement, the survey respondents overwhelmingly identified the lack of wrist and finger movement, as well as poor control capability. However, simply building a mechanism with individual finger and wrist motion is not enough. In the 1960's and 1970's, engineers built a number of more dexterous prosthetic hands. Unfortunately, these were rejected during clinical trials due to a difficult and distracting control interface. The goal of this project, "Applying Space Technology to Enhance Control of an Artificial Arm for Children and Adults with Amputations," was to lay the foundation for a multi-function, intuitive myoelectric control system which requires no conscious thought to move the hand. We built an extensive myoelectric signal database for six motions from ten amputee volunteers, We also tested a control system based on new artificial intelligence techniques on the data from two of these subjects. This data is available to anyone doing myoelectric control research. Its availability is an important contribution to the prosthetics research community, as many researchers do not have access to amputee subjects. Since we collected myoelectric data from subjects' sound arms as well as their residual arms, this database will also prove useful to virtual reality and robotics researchers who want to explore myoelectric-based interfaces between any user and a machine. Currently, one small company (Intelligenta, Inc.) and one university (University of New Brunswick, Canada) are using this myoelectric database under other funding to develop multifunction control systems for prostheses. A prosthetics manufacturer (Liberty Technology, Inc.) is making plans to incorporate the results of their work into an artificial hand capable of several different movements to provide functionality only dreamed of by current myoelectric users. Methods Six adults and four children, all with unilateral, below-elbow amputations served as subjects. Five of the adults (3 male, 2 female, average age 34 years) had amputations due to traumatic injury, while one adult (female, age 32 years) and the four children (3 male, 1 female, average age 13 years) had congenital (i.e. from birth) limb deficiencies.

Atkins, Diane J.↗