Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Angling for insights: illuminating light new physics at Mu3e through angular correlations

We examine the capability of Mu3e to probe light new physics scenarios that produce a prompt electron-positron resonance and demonstrate how angular observables are instrumental in enhancing the experimental sensitivity. We systematically investigate the effect of Mu3e’s expected sensitivity on the parameter space of the dark photon, as well as on axion-like particles and light scalars with couplings to muons and electrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Very-High Dynamic Range, 10,000 Frames/Second Pixel Array Detector for Electron Microscopy

Precision and accuracy of quantitative scanning transmission electron microscopy (STEM) methods such as ptychography, and the mapping of electric, magnetic, and strain fields depend on the dose. Reasonable acquisition time requires high beam current and the ability to quantitatively detect both large and minute changes in signal. A new hybrid pixel array detector (PAD), the second-generation Electron Microscope Pixel Array Detector (EMPAD-G2), addresses this challenge by advancing the technology of a previous generation PAD, the EMPAD. The EMPAD-G2 images continuously at a frame-rates up to 10 kHz with a dynamic range that spans from low-noise detection of single electrons to electron beam currents exceeding 180 pA per pixel, even at electron energies of 300 keV. The EMPAD-G2 enables rapid collection of high-quality STEM data that simultaneously contain full diffraction information from unsaturated bright-field disks to usable Kikuchi bands and higher-order Laue zones. Test results from 80 to 300 keV are presented, as are first experimental results demonstrating ptychographic reconstructions, strain and polarization maps. We introduce a new information metric, the maximum usable imaging speed (MUIS), to identify when a detector becomes electron-starved, saturated or its pixel count is mismatched with the beam current.

36 MATERIALS SCIENCE↗

Development of selenium imaging detectors toward a definitive search for neutrinoless ββ decay

Imaging sensors made from an ionization target layer of amorphous selenium (aSe) coupled to a silicon complementary metal-oxide-semiconductor (CMOS) active pixel array for charge readout are a promising technology for neutrino physics. The high spatial resolution in a solid-state target provides unparalleled rejection of backgrounds from natural radioactivity in the search for the neutrinoless ββ decay of 82 Se. With this grant, we experimentally determined two crucial factors necessary for the realization of this novel technology: i) the intrinsic energy response of aSe to ionizing electrons, and ii) the feasibility to couple a target layer of aSe to a CMOS active pixel sensor to image electron tracks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Femtosecond-Terawatt Hard X-Ray Pulse Generation with Chirped Pulse Amplification on a Free Electron Laser

Advances of high intensity lasers have opened up the field of strong field physics and led to a broad range of technological applications. Recent x ray laser sources and optics development makes it possible to obtain extremely high intensity and brightness at x ray wavelengths. In this paper, we present a system design that implements chirped pulse amplification for hard x ray free electron lasers. Numerical modeling with realistic experimental parameters show that near-transform-limit single-femtosecond hard x ray laser pulses with peak power exceeding 1 TW and brightness exceeding 4×10 35 s -1 mm -2 mrad -2 0.1\%bandwdith -1 can be consistently generated. In conclusion, realization of such beam qualities is essential for establishing systematic and quantitative understanding of strong field x-ray physics and nonlinear x ray optics phenomena.

47 OTHER INSTRUMENTATION↗

Power Electronics Thermal Management

This project conducts research to develop new power electronics thermal management technologies to increase power density, enable high WBG temperature operation, and decrease cost. One of the main challenges to achieving high power densities is associated with packaging of high-temperature (250°C) WBG devices near lower-temperature-rated components (e.g., electrical boards and capacitors). Additionally, the high junction temperatures of the WBG devices will result in large temperature gradients through the power module layers that will present reliability challenges and require higher-temperature substrates and bonding materials.

47 OTHER INSTRUMENTATION↗

A Tunable Resolution Grating Monochromator and the Quest for Transform Limited Pulses

A variable resolution, transform limited monochromator is designed for the Free Electron Laser (FEL) source of LCLS. It provides monochromatic beam in the 250–1500 eV range, delivering the beam on the second floor of the LCLS experimental Hall. One major requirement for this monochromator is to provide, as close as possible, monochromatic transform limited pulses for time-resolved experiments. The theory and the limit of using classical diffraction scheme to monochromatize Soft X-ray beam, while preserving the pulse length, will be presented, together with the optical scheme of this versatile monochromator design.

47 OTHER INSTRUMENTATION↗

Differential electron yield imaging with STXM

In this report total electron yield (TEY) imaging is an established scanning transmission X-ray microscopy (STXM) technique that gives varying contrast based on a sample's geometry, elemental composition, and electrical conductivity. However, the TEY-STXM signal is determined solely by the electrons that the beam ejects from the sample. A related technique, X-ray beam-induced current (XBIC) imaging, is sensitive to electrons and holes independently, but requires electric fields in the sample. Here we report that multi-electrode devices can be wired to produce differential electron yield (DEY) contrast, which is also independently sensitive to electrons and holes, but does not require an electric field. Depending on whether the region illuminated by the focused STXM beam is better connected to one electrode or another, the DEY-TXM contrast changes sign. DEY-STXM images thus provide a vivid map of a device's connectivity landscape, which can be key to understanding device function and failure. To demonstrate an application in the area of failure analysis, we image a 100 nm, lithographically-defined aluminum nanowire that has failed after being stressed with a large current density.

47 OTHER INSTRUMENTATION↗

High-sensitivity electronic Stark spectrometer featuring a laser-driven light source

We report developmental details of a high-sensitivity Stark absorption spectrometer featuring a laser-driven light source. The light source exhibits intensity fluctuations of ~0.3% over timescales ranging from 1 min to 12 h, minimal drift (≤0.1%/h), and very little 1/f noise at frequencies greater than 200 Hz, which are comparable to or better than an arc-driven light source. Additional features of the spectrometer include balanced detection with multiplex sampling, which yielded lower noise in A, and constant wavelength or wavenumber (energy) spectral bandpass modes. We achieve noise amplitudes of ~7 × 10 –4 and ~6 × 10 –6 in measurements of single A and ΔA spectra (with 92 data points) taking ~7 and ~19 min, respectively.

47 OTHER INSTRUMENTATION↗

Reduction of ion backflow using a quadruple GEM detector with various gas mixtures

In gaseous tracking detectors with a large gaseous volume, like Time Projection Chambers (TPC), multiple layers of Gas Electron Multipliers (GEM) can be used to block positive ions from flowing back into the active volume, which is detrimental to the tracking performance. TPCs with multilayer GEM readout are used in the recently upgraded ALICE experiment, and in the upcoming sPHENIX experiment. In both cases, suppression of ion backflow (IBF) is important for achieving the desired detector performance. Here, we report on studies of effective gain, IBF, and energy resolution in quadruple GEM detectors, and on strategies for minimizing IBF by optimizing the operating voltages of the individual GEM layers and the potential differences between different layers. These studies are performed as baseline measurements intended to aid in the optimization of the operating conditions of the GEMs of the sPHENIX TPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep-Learning Electron Diffractive Imaging

Here, we report the development of deep-learning coherent electron diffractive imaging at subangstrom resolution using convolutional neural networks (CNNs) trained with only simulated data. We experimentally demonstrate this method by applying the trained CNNs to recover the phase images from electron diffraction patterns of twisted hexagonal boron nitride, monolayer graphene, and a gold nanoparticle with comparable quality to those reconstructed by a conventional ptychographic algorithm. Fourier ring correlation between the CNN and ptychographic images indicates the achievement of a resolution in the range of 0.70 and 0.55 Å. We further develop CNNs to recover the probe function from the experimental data. The ability to replace iterative algorithms with CNNs and perform real-time atomic imaging from coherent diffraction patterns is expected to find applications in the physical and biological sciences.

47 OTHER INSTRUMENTATION↗

Parametric Design Study of a Power Electronics Package

The lifetime of a power electronics package is, to a large extent, determined by the reliability of its bonded interfaces under major loading conditions in an operational environment. Based on the application-level requirements of the package, bonded interface material is selected based on the results obtained from accelerated tests such as thermal cycling and power cycling. In addition to evaluating the reliability through accelerated tests, it is important to consider the impact of other component layers on the thermomechanical performance of the interface material, both from a material and geometric perspective. The co-efficient of thermal expansion (CTE) mismatch introduced by the use of different materials within a package and its structural design plays a critical role in determining the interface material reliability. In this paper, we present the results of a parametric modeling study of a power electronics package under thermal cycling in which the materials and geometric design of the different component layers were varied with respect to a baseline design to understand their impact on the reliability of the interface material. We chose the volume-averaged strain energy density per cycle computed at the corner region of the interface material as the metric for the reliability comparisons. Our results indicate that in addition to the CTE mismatch, the stiffness of individual component layers has a major impact on reliability. Among the different baseplates that we studied, aluminum silicon-carbide baseplates offered superior reliability over their copper and aluminum counterparts. We also found that the magnitude of the impact of stiffness variation—amongst the adjacent layers—on the reliability of the solder joint is dependent on the inherent CTE mismatch between the layers.

47 OTHER INSTRUMENTATION↗

Enabling discovery data science through cross-facility workflows

Experimental and observational instruments for scientific research (such as light sources, genome sequencers, accelerators, telescopes and electron microscopes) increasingly require High Performance Computing (HPC) scale capabilities for data analysis and workflow processing. Next-generation instruments are being deployed with higher resolutions and faster data capture rates, creating a big data crunch that cannot be handled by modest institutional computing resources. Often these big data analysis pipelines also require near real-time computing and have higher resilience requirements than the simulation and modeling workloads more traditionally seen at HPC centers. While some facilities have enabled workflows to run at a single HPC facility, there is a growing need to integrate capabilities across HPC facilities to enable cross-facility workflows, either to provide resilience to an experiment, increase analysis throughput capabilities, or to better match a workflow to a particular architecture. In this paper we describe the barriers to executing complex data analysis workflows across HPC facilities and propose an architectural design pattern for enabling scientific discovery using cross-facility workflows that includes orchestration services, application programming interfaces (APIs), data access and co-scheduling.

Antypas, Katerina B.↗

Molybdenum and silver photoemission survey spectra from hard x-rays

Electron emission from thick polished samples of polycrystalline molybdenum (Mo) and single crystalline $\langle$111$\rangle$ silver (Ag) was measured with hard x-ray photoemission spectroscopy. Six different excitation x-ray energies were used, nominally 8.0, 11.0, 13.0, 15.0, 18.0, and 21.5 keV. Survey spectra were recorded with each excitation to a kinetic energy of at most 15 keV, often capturing the entire emission range. The Mo 1s core peak was measured. Detailed LMM Auger spectra of Mo show marked increases in intensity and altered shape when x-ray energy exceeds the Mo 1s binding energy. The Mo and Ag L-shell photoelectron peaks are measured at four x-ray energies up to 18 keV showing the transition from 2p3/2 to 2s photoionization dominance.

47 OTHER INSTRUMENTATION↗

Probe measurements of electric field and electron density fluctuations at megahertz frequencies using in-shaft miniature circuits

In this work, a four-tip electrostatic probe is constructed to measure high-frequency (0.1–10 MHz) fluctuations in both the electric field (one component) and electron density in a laboratory plasma. This probe also provides data for the local electron temperature and density. Circuits for high-frequency measurements are fabricated on two miniature boards, which are embedded in the probe shaft, near the tips to minimize the pickup of common-mode signals. The amplitude and phase response of two circuits to sinusoidal test signals are measured and compared with results from modeling. For both circuits, the phase shift between input and output signals is relatively small (<30°). The performance of the probe is verified in a high-density (~10 13 cm –3 ) and low-temperature (≲10 eV) plasma. The probe successfully measures high-frequency (~2 MHz) fluctuations in the electric field and density, which are associated with lower hybrid drift waves. This probe can provide information on the wave-associated anomalous drag, which can be compared with the classical resistivity.

47 OTHER INSTRUMENTATION↗

Parametric Design Study of a Power Electronics Package for Improving Solder Joint Reliability

The lifetime of a power electronics package is, to a large extent, determined by the reliability of its bonded interfaces under major loading conditions in an operational environment. Based on the application-level requirements of the package, bonded interface material is selected based on the results obtained from accelerated tests such as thermal cycling and power cycling. In addition to evaluating the reliability through accelerated tests, it is important to consider the impact of other component layers on the thermomechanical performance of the interface material, both from a material and geometric perspective. The co-efficient of thermal expansion (CTE) mismatch introduced by the use of different materials within a package and its structural design plays a critical role in determining the interface material reliability. In this paper, we present the results of a parametric modeling study of a power electronics package under thermal cycling in which the materials and geometric design of the different component layers were varied with respect to a baseline design to understand their impact on the reliability of the interface material. We chose the volume-averaged strain energy density per cycle computed at the corner region of the interface material as the metric for the reliability comparisons. Our results indicate that in addition to the CTE mismatch, the stiffness of individual component layers has a major impact on reliability. Among the different baseplates that we studied, aluminum silicon-carbide baseplates offered superior reliability over their copper and aluminum counterparts. We also found that the magnitude of the impact of stiffness variation—amongst the adjacent layers—on the reliability of the solder joint is dependent on the inherent CTE mismatch between the layers.

47 OTHER INSTRUMENTATION↗

Wind Energy Instrumentation Development Roadmap

The instrumentation development roadmap provides a guide on which measurements, and instruments, are important for future field campaigns to meet both the science objects and validation plans for their successful execution. The roadmap ensures the measurements are of sufficient type and resolution to meet science objectives and validation needs essential to the campaigns. The roadmap includes measurement categories ranging from instruments that need to be created to existing instruments essential to the field campaigns. The creation of the instrumentation development roadmap builds upon the previous Atmospheric to Electrons (A2e) validation work and formation of the American WAKE experimeNt (AWAKEN) science objectives.

17 WIND ENERGY↗