Search NASA⌕ Search

SEARCH · Search NASA

Results for “epoxy composite”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Post-Deployment Characterization of Glass Fiber-Reinforced Thermoset and Thermoplastic Composite Tidal Turbine Blades

In 2021, the National Renewable Energy Laboratory (NREL) supported Verdant Power with the most successful tidal energy deployment in U.S. history. Three of their Gen5d 5 m turbines were deployed as part of the Roosevelt Island Tidal Energy project. Initially, the three deployed rotors were manufactured from glass fiber-reinforced epoxy composites. Midway through the deployment, one rotor was replaced with one manufactured at NREL. The new rotor utilized a novel infusible thermoplastic resin system (Elium from Arkema). Since the deployment, one epoxy rotor and one thermoplastic rotor were returned to NREL for continued materials and manufacturing research. The two rotors underwent full-scale structural testing before being sectioned and cut into specimens for a variety of manufacturing quality tests, thermomechanical characterization, and evaluation of material performance in marine environments to understand the key differences between the fiberglass-reinforced epoxy and Elium composites used for the respective rotors. Matrix burn-off tests showed that the Elium blades had a considerably higher fiber volume fraction compared to the epoxy blades (61% vs. 49%). Environmental aging of the specimens showed that the epoxy laminates absorbed more water over the conditioning period; however, it was determined that the Elium laminates had higher diffusion coefficients, so they initially absorbed water faster. Finally, one full epoxy blade and one full Elium blade were conditioned at ambient temperatures for up to 11 months, while periodic mass measurements were taken. The datasets were extrapolated to assume a full 20-year operational life span, and it was determined that the blades would not reach full saturation during that time span.

composite manufacturing↗

Concepts for improving the damage tolerance of composite compression panels

The results of an experimental evaluation of graphite-epoxy composite compression panel impact damage tolerance and damage propagation arrest concepts are reported. The tests were conducted on flat plate specimens and blade-stiffened structural panels such as those used in commercial aircraft wings, and the residual strength of damaged specimens and their sensitivity to damage while subjected to in-plane compression loading were determined. Results suggest that matrix materials that fail by delamination have the lowest damage tolerance, and it is concluded that alternative matrix materials with transverse reinforcement to suppress the delamination failure mode and yield the higher-strain value transverse shear crippling mode should be developed.

Rhodes, M. D.↗

Basic failure mechanisms in advanced composites

The fundamental failure mechanisms which result from the interaction of thermal cycling and mechanical loading of carbon-epoxy composites were studied. This work was confined to epoxy resin uniderictionally reinforced with HTS carbon fibers, and consists of first identifying local fiber, matrix and interface failure mechanisms using the model composite specimen containing a small number of fibers so that optical techniques can be used for characterization. After the local fracture process has been established for both mechanical loading and thermal cycling, engineering composite properties and gross fracture modes are then examined to determine how the local events contribute to real composite performance. Flexural strength in high fiber content specimens shows an increase in strength with increased thermal cycling. Similar behavior is noted for 25 v/o material up to 200 cycles; however, there is a drastic reduction after 200 cycles indicating a major loss of integrity probably through the accumulation of local cleavage cracks in the tensile region.

Mazzio, V. F.↗

Response of graphite/epoxy composites to moisture

Report presents comparative absorption and desorption data obtained from response of graphite epoxy composites to moisture experiments with Fiberite 934, Narmco 5208, and Hexcel F-263 epoxy resin systems in cross-piled collimated laminates containing Thornel-300 graphite fibers.

Powell, H.↗

Radiation Exposure of Selected Composites and Thin Films

The effect of electron radiation on selected candidate composite materials was investigated. Radiation damage mechanisms were identified and the coefficient of thermal expansion were measured for each type composite material. It was concluded that the threshold for major physical and mechanical property changes in the polysulfone films and in the polysulfone and epoxy composites is in excess of 1 x 10 to the 9th power rads of electrons. Based upon these data, the 5208 and 934 epoxies and the P1700 polysulfone composites would be acceptable for 5 to 10 year geosynchronous Earth environment missions receiving 1 x 10 to the 9th power rads of electron radiation.

Wayne S Slemp↗

Mechanical properties of neat polymer matrix materials and their unidirectional carbon fiber-reinforced composites

The mechanical properties of two neat resin systems for use in carbon fiber epoxy composites were characterized. This included tensile and shear stiffness and strengths, coefficients of thermal and moisture expansion, and fracture toughness. Tests were conducted on specimens in the dry and moisture-saturated states, at temperatures of 23, 82 and 121 C. The neat resins tested were American Cyanamid 1806 and Union Carbide ERX-4901B(MPDA). Results were compared to previously tested neat resins. Four unidirectional carbon fiber reinforced composites were mechanically characterized. Axial and transverse tension and in-plane shear strengths and stiffness were measured, as well as transverse coefficients of thermal and moisture expansion. Tests were conducted on dry specimens only at 23 and 100 C. The materials tested were AS4/3502, AS6/5245-C, T300/BP907, and C6000/1806 unidirectional composites. Scanning electron microscopic examination of fracture surfaces was performed to permit the correlation of observed failure modes with the environmental test conditions.

Zimmerman, Richard S.↗

Thin-walled composite beams under bending, torsional, and extensional loads

Symmetric and antisymmetric layup graphite-epoxy composite beams with thin-walled rectangular cross sections are fabricated using an autoclave molding technique and tested under bending, torsional, and extensional loads. The bending slope and elastic twist at a station are measured using an optical system, and the results correlated with predicted values from a simple beam analysis as well as a refined finite element analysis. A symmetric ply layup results in bending-twist coupling whereas an antisymmetric layup causes extension-twist coupling. Simple analytical results with plane-stress assumption agree better with measured data as well as finite element predictions than with plane-strain assumption. For symmetric layup beams, the bending-induced twist and torsion-induced bending slope are predicted satisfactorily using simple analytical solution. Correlations with measured data, however, are generally improved using a finite element solution. For antisymmetric beams, axial force-induced twist is predicted satisfactorily by both methods.

Chandra, Ramesh↗

Thermal expansion of selected graphite-reinforced polyimide-, epoxy-, and glass-matrix composites

The thermal expansion of continuous carbon-fiber reinforced composites with epoxy-, polyimide-, and borosilicate glass-matrices has been measured and compared. The expansion of a rubber-toughened epoxy-matrix/P75S carbon-fiber composite was very different from the expansion of two different single-phase epoxy-matrix/P75S composites, although all three had the same stacking sequence. Reasonable agreement was obtained between measured thermal expansion data and results from classical laminate theory. Microdamage in the graphite/polyimide laminate, induced by 250 cycles between -156 and 121 C, caused a 53 percent decrease in the coefficient of thermal expansion. The thermal expansion of the graphite/glass laminate was not changed after 100 thermal cycles from -129 to 38 C; however, a residual strain of about 10 x 10 to the -6 was observed for the laminate tested.

Tompkins, S. S.↗

Scaling of energy absorbing composite plates

The energy absorption response and crushing characteristics of geometrically scaled graphite-Kevlar epoxy composite plates were investigated. Three different trigger mechanisms including chamfer, notch, and steeple geometries were incorporated into the plate specimens to initiate crushing. Sustained crushing was achieved with a simple test fixture which provided lateral support to prevent global buckling. Values of specific sustained crushing stress (SSCS) were obtained which were comparable to values reported for tube specimens from previously published data. Two sizes of hybrid plates were fabricated; a baseline or model plate, and a full-scale plate with in-plane dimensions scaled by a factor of two. The thickness dimension of the full-scale plates was increased using two different techniques; the ply-level method in which each ply orientation in the baseline laminate stacking sequence is doubled, and the sublaminate technique in which the baseline laminate stacking sequence is repeated as a group. Results indicated that the SSCS is independent of trigger mechanism geometry. However, a reduction in the SSCS of 10-25 percent was observed for the full-scale plates as compared with the baseline specimens, indicating a scaling effect in the crushing response.

Jackson, Karen↗

Scaling of energy absorbing composite plates

The energy absorption response and crushing characteristics of geometrically scaled graphite-Kevlar epoxy composite plates were investigated. Two different trigger mechanisms including notch, and steeple geometries were incorporated into the plate specimens to initiate crushing. Sustained crushing was achieved with a new test fixture which provided lateral support to prevent global buckling. Values of specific sustained crushing stress (SSCS) were obtained which were lower than values reported for tube specimens from previously published data. Two sizes of hybrid plates were fabricated; a baseline or model plate, and a full-scale plate with inplane dimensions scaled by a factor of two. The thickness dimension of the full-scale plates was increased using two different techniques: the ply-level method in which each ply orientation in the baseline laminate stacking sequence is doubled, and the sublaminate technique in which the baseline laminate stacking sequence is repeated as a group. Results indicated that the SSCS has a small dependence on trigger mechanism geometry. However, a reduction in the SSCS of 10-25% was observed for the full-scale plates as compared with the baseline specimens, indicating a scaling effect in the crushing response.

Jackson, Karen↗

High Strain Rate Response of Adhesively Bonded Fiber-Reinforced Composite Joints – A Computational Study to Guide Experimental Design

Adhesively bonded carbon fiber-reinforced epoxy composite laminates are widely used in aerospace applications. During a high energy impact event, these laminates are often subjected to high strain rate loading. However, the influence of high strain rate loading on the response of these composite joints is not well understood. Computational finite element (FE) modeling and simulations are conducted to guide the design of high strain rate experiments. Two different experimental designs based on split Hopkinson bar were numerically modeled to simulate Mode I and Mode II types loading in the composite. In addition, the computational approach adopted in this study helps in understanding the high strain rate response of adhesively bonded composite joints subjected to nominally Mode I and Mode II loading. The modeling approach consists of a ply-level 3D FE model, a progressive damage constitutive model for the composite material behavior and a cohesive tie-break contact element for interlaminar delamination.

Ravindran, Suraj↗

Testing of Composite Laminate Specimens with Mid-Length Lateral Notches

Eight fiber-reinforced, carbon-epoxy composite laminate specimens without external stiffeners (unstiffened) were loaded to failure to determine their failure load and mode under the Advanced Composites Project (ACP) Rapid Design Tools activity. Each specimen contained a lateral notch located at the mid-length location. A description of the specimens, instrumentation, test fixtures and procedures is presented, followed by the presentation of the experimental results.

Dawn C Jegley↗

Criterion for mixed mode fracture in composite bonded joints

A study was undertaken to characterize the debond growth mechanism of adhesively bonded composite joints under mode I, mixed mode I-II, and mode II static loadings. The bonded system consisted of graphite-epoxy composite adherends bonded with a toughened epoxy adhesive. The mode I, mode II and mixed mode I-II fracture energies of the tested adhesives were found to be equal to each other. The criterion for mixed mode fracture in composite bonded joints was found.

Mall, S.↗

Compression failure of composite laminates

This presentation attempts to characterize the compressive behavior of Hercules AS-1/3501-6 graphite-epoxy composite. The effect of varying specimen geometry on test results is examined. The transition region is determined between buckling and compressive failure. Failure modes are defined and analytical models to describe these modes are presented.

Pipes, R. B.↗

Ultrasonic Monitoring of Ply Crack and Delamination Formation in Composite Tube Under Torsion Load

As a simple model of a rotor spar, a circular graphite-epoxy composite laminate cylinder was subjected to cyclic torsional load. The test section of the cylindrical specimen varied from four to six plies of plus or minus 45 degree fibers, due to intentional ply overlaps and gaps. A layer of 13-micrometer Teflon film was inserted between plies at three locations to serve as delamination initiators. A commercial X-Y scanner was mounted to the load frame to enable ultrasonic inspection without removing the specimen. A focused immersion probe was mounted in a captive water column with a rugged Nitrile membrane tip, which was coupled to the cylinder using a mist of soapy water. The transducer was aligned normal to the cylinder surface using the X-axis. Scanning was performed along the length of the specimen with the Y-axis and the specimen was incrementally rotated by the torsion head of the load frame. After 350k cycles of torsion, several linear 45 degree diagonal indications appeared as 5-40% attenuation of the back wall echo, with no apparent echoes from the interior of the composite, suggesting through-ply cracks in the innermost ply. Crack indications grew and new cracks appeared as torsion cycling continued. Internal reflections from delaminations associated with the growing ply cracks appeared after 500k cycles. Three areas of extensive multi-layer delaminations appeared after 1150k cycles. Failure of the specimen occurred at 1600k cycles. The observed progressive damage was not associated with the Teflon inclusions. Concurrent thermographic measurements provided lower resolution confirmation of the damage observed.

Johnston, P. H.↗

Effects of fiber/matrix interactions on the properties of graphite/epoxy composites

A state-of-the-art literature review of the interactions between fibers and resin within graphite epoxy composite materials was performed. Emphasis centered on: adhesion theory; wetting characteristics of carbon fiber; load transfer mechanisms; methods to evaluate and measure interfacial bond strengths; environmental influence at the interface; and the effect of the interface/interphase on composite performance, with particular attention to impact toughness. In conjunction with the literature review, efforts were made to design experiments to study the wetting behavior of carbon fibers with various finish variants and their effect on adhesion joint strength. The properties of composites with various fiber finishes were measured and compared to the base-line properties of a control. It was shown that by tailoring the interphase properties, a 30% increase in impact toughness was achieved without loss of mechanical properties at both room and elevated temperatures.

Mcmahon, P. E.↗

Study Acoustic Emissions from Composites

The purpose of this work will be to develop techniques for monitoring the acoustic emissions from carbon epoxy composite structures at cryogenic temperatures. Performance of transducers at temperatures ranging from ambient to cryogenic and the characteristics of acoustic emission from composite structures will be studied and documented. This entire effort is directed towards characterization of structures used in NASA propulsion programs such as the X-33.

Walker, James↗