Search NASA⌕ Search

SEARCH · Search NASA

Results for “errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A Variational Method for Analyzing Vortex Flows in Radar-Scanned Tornadic Mesocyclones. Part III: Sensitivities to Vortex Center Location Errors

Abstract When the vortex center location is estimated from a radar-scanned tornadic mesocyclone, the estimated location is not error-free. This raises an important issue concerning the sensitivities of analyzed vortex flow (VF) fields by the VF-Var (formulated in Part I of this paper series and tested in Part II) to vortex center location errors, denoted by Δ x c . Numerical experiments are performed to address this issue with the following findings: The increase of |Δ x c | from zero to a half of vortex core radius causes large analysis error increases in the vortex core but the increased analysis errors decrease rapidly away from the vortex core especially for dual-Doppler analyses. The increased horizontal-velocity errors in the vortex core are mainly in the Δ x c -normal component, because this component varies much more rapidly than the other component along the Δ x c direction in the vortex core. The vertical variations of Δ x c distort the vertical correlation structure of Δ x c -dislocated VF-dependent background error covariance, which can increase the analysis errors in the vortex core. The dual-Doppler analyses have adequate accuracies outside the vortex core even when |Δ x c | increases to a half of vortex core radius, while single-Doppler analyses can also have adequate accuracies outside the vortex core mainly for the single-Doppler-observed velocity component. The sensitivities to Δ x c are largely unaffected by the vortex slanting. The above findings are important and useful for assessing the accuracies of analyzed VFs for real radar-observed tornadic mesocyclones. Significance Statement When the vortex center location is estimated from a radar-scanned tornadic mesocyclone, the estimated location is not error-free. This raises an issue concerning the sensitivity of analyzed vortex flow (VF) by the VF-Var (formulated in Part I of this paper series and tested with simulated radar observations in Part II) to vortex center location error. This issue and its required investigations are very important for the VF-Var to be applied to real radar-observed tornadic mesocyclones, especially in an operational setting with the WSR-88Ds. Numerical experiments are performed to address this issue. The findings from these experiments are important and useful for assessing the accuracies of VF-Var analyzed VF fields for real radar-observed tornadic mesocyclones.

Xu, Qin↗

Comparison of Errors in Solar Power Plant Variability Simulation Methods

Four PV power plant variability simulation methods - no-smoothing, time average, Marcos, and the wavelet variability model (WVM) - were compared to measured data from a 19MW PV power plant to test the relative accuracy of each method. Errors (simulated vs. measured) were quantified using five application-specific metrics: the largest down ramps, the largest up ramps, the mean absolute error in matching the cumulative distribution of large ramps, the total energy contained in down ramps over the entire period considered, total energy in down ramps on the worst day. These errors we evaluated over timescales ranging from 1-second to 1-hour and over plant sizes of 1 to 14MW and the total plant size of 19MWs to determine trends in model errors as a function of timescale and plant size. Overall, the WVM was found to most often have the smallest errors. The Marcos method also often had small errors, including having the smallest errors of all methods at small PV plant sizes (1 to 7MWs). The no-smoothing method had large errors and should not be used. The time average method was an improvement over the no-smoothing method, but generally has larger errors than the WVM and Marcos methods.

14 SOLAR ENERGY↗

Ordering of Trotterization: Impact on Errors in Quantum Simulation of Electronic Structure

Trotter–Suzuki decompositions are frequently used in the quantum simulation of quantum chemistry. They transform the evolution operator into a form implementable on a quantum device, while incurring an error—the Trotter error. The Trotter error can be made arbitrarily small by increasing the Trotter number. However, this increases the length of the quantum circuits required, which may be impractical. It is therefore desirable to find methods of reducing the Trotter error through alternate means. The Trotter error is dependent on the order in which individual term unitaries are applied. Due to the factorial growth in the number of possible orderings with respect to the number of terms, finding an optimal strategy for ordering Trotter sequences is difficult. In this paper, we propose three ordering strategies, and assess their impact on the Trotter error incurred. Initially, we exhaustively examine the possible orderings for molecular hydrogen in a STO-3G basis. We demonstrate how the optimal ordering scheme depends on the compatibility graph of the Hamiltonian, and show how it varies with increasing bond length. We then use 44 molecular Hamiltonians to evaluate two strategies based on coloring their incompatibility graphs, while considering the properties of the obtained colorings. We find that the Trotter error for most systems involving heavy atoms, using a reference magnitude ordering, is less than 1 kcal/mol. Relative to this, the difference between ordering schemes can be substantial, being approximately on the order of millihartrees. The coloring-based ordering schemes are reasonably promising—particularly for systems involving heavy atoms—however further work is required to increase dependence on the magnitude of terms. Finally, we consider ordering strategies based on the norm of the Trotter error operator, including an iterative method for generating the new error operator terms added upon insertion of a term into an ordered Hamiltonian.

97 MATHEMATICS AND COMPUTING↗

Wind and Load Forecast Error Model for Multiple Geographically Distributed Forecasts

The impact of wind and load forecast errors on power grid operations is frequently evaluated by conducting multi-variant studies, where these errors are simulated repeatedly as random processes based on their known statistical characteristics. To generate these errors correctly, we need to reflect their distributions (which do not necessarily follow a known distribution law), standard deviations, auto- and cross-correlations. For instance, load and wind forecast errors can be closely correlated in different zones of the system. This paper introduces a new methodology for generating multiple cross-correlated random processes to simulate forecast error curves based on a transition probability matrix computed from an empirical error distribution function. The matrix will be used to generate new error time series with statistical features similar to observed errors. We present the derivation of the method and present some experimental results by generating new error forecasts together with their statistics.

17 WIND ENERGY↗

Characterizing the Impact of Soft Errors Affecting Floating-point ALUs using RTL-level Fault Injection

Strategies to detect, correct, or mitigate the impact of soft errors rely on errors-injection experiments. For efficient evaluation, such experiments typically inject errors in software by sampling errors from a candidate distribution. Most often, these strategies randomly select and flip one bit in the output of an instruction. While single-bit flips might constitute a meaningful model for errors affecting hardware, the appropriateness of this model for software-based errors has not been studied. In this paper, we study the manifestation of errors in the output registers due to errors affecting candidate instructions executed by floating point ALUs. We inject single-bit flips into the RTL descriptions of floating point ALUs and analyze the differences between anticipated and observed outputs when executing floating-point addition, subtraction, multiplication, and division. We choose the operands for these instructions randomly and from operands observed in five benchmarks. We observe a rich distribution of errors in the output and analyze their implications for software-based fault-injection campaigns.

Subasi, Omer↗

Neutron multiplication error in TRU waste measurements

Total Measurement Uncertainty (TMU) in neutron assays of transuranic waste (TRU) are comprised of several components including counting statistics, matrix and source distribution, calibration inaccuracy, background effects, and neutron multiplication error. While a minor component for low plutonium masses, neutron multiplication error is often the major contributor to the TMU for items containing more than 140 g of weapons grade plutonium. Neutron multiplication arises when neutrons from spontaneous fission and other nuclear events induce fissions in other fissile isotopes in the waste, thereby multiplying the overall coincidence neutron response in passive neutron measurements. Since passive neutron counters cannot differentiate between spontaneous and induced fission neutrons, multiplication can lead to positive bias in the measurements. Although neutron multiplication can only result in a positive bias, it has, for the purpose of mathematical simplicity, generally been treated as an error that can lead to either a positive or negative result in the TMU. While the factors that contribute to neutron multiplication include the total mass of fissile nuclides, the presence of moderating material in the matrix, the concentration and geometry of the fissile sources, and other factors; measurement uncertainty is generally determined as a function of the fissile mass in most TMU software calculations because this is the only quantity determined by the passive neutron measurement. Neutron multiplication error has a particularly pernicious consequence for TRU waste analysis because the measured Fissile Gram Equivalent (FGE) plus twice the TMU error must be less than 200 for TRU waste packaged in 55-gal drums and less than 325 for boxed waste. For this reason, large errors due to neutron multiplication can lead to increased rejections of TRU waste containers. This report will attempt to better define the error term due to neutron multiplication and arrive at values that are more realistic and accurate. To do so, measurements of standards and waste drums were performed with High Efficiency Neutron Counters (HENC) located at Los Alamos National Laboratory (LANL). The data were analyzed for multiplication effects and new estimates of the multiplication error were computed. A concluding section will present alternatives for reducing the number of rejections of TRU waste containers due to neutron multiplication error.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling mechanical behavior of an additively manufactured metal structure with local texture variations: a study on model form error

Here, the repetitive rapid solidification that occurs in metal additive manufacturing (AM) processes creates microstructures distinctly different from wrought materials. Local variability in AM microstructures (either by design or unintentional) raises questions as to how AM structures should be modeled at the part-scale to minimize modeling error. The key goal of this work is to demonstrate a posteriori error estimation applied to an AM part. It is assumed that the actual microstructure is unknown and an approximate, spatially uniform material model is used. Error bounds are calculated for many reference models based on AM microstructures with elongated grain morphology and localized or global fiber textures during a post-processing step. The current findings promote confidence that a posteriori model form error estimation could be used effectively in mechanical performance simulations of AM parts to quickly obtain quantitative error metrics between an approximate model result and many microstructure-based reference models. The a posteriori error estimation introduces significant time savings compared to computing the full reference model solutions. Tight bounds on model form error are obtained when texture variations in the reference models occur on large length scales. For materials with property variation at small length scales, multi-scale error estimation techniques are needed to properly account for the many interfaces present between areas with different properties.

36 MATERIALS SCIENCE↗

Ground-Truth Prediction to Accelerate Soft-Error Impact Analysis for Iterative Methods

Understanding the impact of soft errors on applications can be expensive. Often, it requires an extensive error injection campaign involving numerous runs of the full application in the presence of errors. In this paper, we present a novel approach to arriving at the ground truth--the true impact of an error on the final output--for iterative methods by observing a small number of iterations to learn deviations between normal and error-impacted execution. We develop a machine learning based predictor for three iterative methods to generate ground-truth results without running them to completion for every error injected. We demonstrate that this approach achieves greater accuracy than alternative prediction strategies, including three existing soft error detection strategies. We demonstrate the effectiveness of the ground truth prediction model in evaluating vulnerability and the effectiveness of soft error detection strategies in the context of iterative methods.

iterative methods, failure prediction, Soft error ↗

Estimation of Errors in Stress Distributions Computed in Finite Element Simulations of Polycrystals

The accuracy of the stresses predicted from crystal plasticity-based finite element formulation depends on estimation and control of the errors associated with the discretization. In the current work, the errors in the stress distribution are estimated in virtual polycrystalline samples of α-phase titanium (hexagonal close-packed phase of Ti–6Al– 4 V). To estimate the error, the stress field, which does not possess inter-element continuity, is smoothed over a grain using an L 2 projection, thereby providing continuous stress distributions with inter-element continuity. The differences between the continuous (smooth) and discontinuous (raw) stress fields are calculated at individual Gauss quadrature points and used to estimate errors for corresponding elements and grains. Error estimations are performed for a Voronoi-tessellated microstructure, an equiaxed microstructure, and two microstructures with varying grain sizes for tensile loading extending into the fully plastic regime (≈ 5% extension). Magnitudes of the errors are found to depend on microstructural characteristics, particularly the shape and size of grains. Samples having variations in grain size or having less spherical grains exhibited higher errors than samples with uniformly sized, equiaxed grains, with the size variations having a more pronounced effect. In conclusion, errors correlate with proximity to grain boundaries at small (elastic) strains and with deformation-induced features (deformation bands) at large strains.

42 ENGINEERING↗

Radiographic and Anatomic Basis for Prostate Contouring Errors and Methods to Improve Prostate Contouring Accuracy

Purpose: Use of highly conformal radiation for prostate cancer can lead to both overtreatment of surrounding normal tissues and undertreatment of the prostate itself. In this retrospective study we analyzed the radiographic and anatomic basis of common errors in computed tomography (CT) contouring and suggest methods to correct them. Methods and Materials: Three hundred patients with prostate cancer underwent CT and magnetic resonance imaging (MRI). The prostate was delineated independently on the data sets. CT and MRI contours were compared by use of deformable registration. Errors in target delineation were analyzed and methods to avoid such errors detailed. Results: Contouring errors were identified at the prostatic apex, mid gland, and base on CT. At the apex, the genitourinary diaphragm, rectum, and anterior fascia contribute to overestimation. At the mid prostate, the anterior and lateral fasciae contribute to overestimation. At the base, the bladder and anterior fascia contribute to anterior overestimation. Transition zone hypertrophy and bladder neck variability contribute to errors of overestimation and underestimation at the superior base, whereas variable prostate-to-seminal vesicle relationships with prostate hypertrophy contribute to contouring errors at the posterior base. Conclusions: Most CT contouring errors can be detected by (1) inspection of a lateral view of prostate contours to detect projection from the expected globular form and (2) recognition of anatomic structures (genitourinary diaphragm) on the CT scans that are clearly visible on MRI. This study shows that many CT prostate contouring errors can be improved without direct incorporation of MRI data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Rotational Errors in Treatment Setup of Stereotactic Body Radiation Therapy of Liver Cancer

Purpose: To evaluate the dosimetric impact of rotational setup errors in stereotactic body radiotherapy (SBRT) treatment of liver tumors and to investigate whether translational shifts can compensate for rotation. Methods and Materials: The positioning accuracy in 20 patients with liver malignancies treated with SBRT was reevaluated offline by matching the patients' cone-beam computed tomography (CT) scans (n=75) to the planning CT scans and adjusting the 3 rotational angles (pitch, roll, and yaw). Systematic and random setup errors were calculated. The dosimetric changes caused by rotational setup errors were quantified for both simulated and observed patient rotations. Dose distributions recalculated on the rotated CT scans were compared with the original planned doses. Translational corrections were simulated based on manual translational registration of the rotated images to the original CT scans. The correction efficacy was evaluated by comparing the recalculated plans with the original plans. Results: The systematic rotational setup errors were -0.06 Degree-Sign {+-} 0.68 Degree-Sign , -0.29 Degree-Sign {+-} 0.62 Degree-Sign , and -0.24 Degree-Sign {+-} 0.61 Degree-Sign ; the random setup errors were 0.80 Degree-Sign , 1.05 Degree-Sign , and 0.61 Degree-Sign for pitch, roll, and yaw, respectively. Analysis of CBCT images showed that 56.0%, 14.7%, and 1.3% of treated fractions had rotational errors of >1 Degree-Sign , >2 Degree-Sign , and >3 Degree-Sign , respectively, in any one of the rotational axes. Rotational simulations demonstrated that the reduction of gross tumor volume (GTV) coverage was <2% when rotation was <3 Degree-Sign . Recalculated plans using actual patient roll motions showed similar reduction (<2%) in GTV coverage. Translational corrections improved the GTV coverage to within 3% of the original values. For organs at risk (OAR), the dosimetric impact varied case by case. Conclusion: Actual rotational setup errors in SBRT for liver tumors are relatively small in magnitude and are unlikely to affect GTV coverage significantly. Translational corrections can be optimized to compensate for rotational setup errors. However, caution regarding possible dose increases to OAR needs to be exercised.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Implications of Residual Tracking Errors During Robotic SBRT of Liver Metastases

Purpose: Although the metric precision of robotic stereotactic body radiation therapy in the presence of breathing motion is widely known, we investigated the dosimetric implications of breathing phase–related residual tracking errors. Methods and Materials: In 24 patients (28 liver metastases) treated with the CyberKnife, we recorded the residual correlation, prediction, and rotational tracking errors from 90 fractions and binned them into 10 breathing phases. The average breathing phase errors were used to shift and rotate the clinical tumor volume (CTV) and planning target volume (PTV) for each phase to calculate a pseudo 4-dimensional error dose distribution for comparison with the original planned dose distribution. Results: The median systematic directional correlation, prediction, and absolute aggregate rotation errors were 0.3 mm (range, 0.1-1.3 mm), 0.01 mm (range, 0.00-0.05 mm), and 1.5° (range, 0.4°-2.7°), respectively. Dosimetrically, 44%, 81%, and 92% of all voxels differed by less than 1%, 3%, and 5% of the planned local dose, respectively. The median coverage reduction for the PTV was 1.1% (range in coverage difference, −7.8% to +0.8%), significantly depending on correlation (P=.026) and rotational (P=.005) error. With a 3-mm PTV margin, the median coverage change for the CTV was 0.0% (range, −1.0% to +5.4%), not significantly depending on any investigated parameter. In 42% of patients, the 3-mm margin did not fully compensate for the residual tracking errors, resulting in a CTV coverage reduction of 0.1% to 1.0%. Conclusions: For liver tumors treated with robotic stereotactic body radiation therapy, a safety margin of 3 mm is not always sufficient to cover all residual tracking errors. Dosimetrically, this translates into only small CTV coverage reductions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bolus-dependent dosimetric effect of positioning errors for tangential scalp radiotherapy with helical tomotherapy

The dosimetric effect of errors in patient position is studied on-phantom as a function of simulated bolus thickness to assess the need for bolus utilization in scalp radiotherapy with tomotherapy. A treatment plan is generated on a cylindrical phantom, mimicking a radiotherapy technique for the scalp utilizing primarily tangential beamlets. A planning target volume with embedded scalplike clinical target volumes (CTVs) is planned to a uniform dose of 200 cGy. Translational errors in phantom position are introduced in 1-mm increments and dose is recomputed from the original sinogram. For each error the maximum dose, minimum dose, clinical target dose homogeneity index (HI), and dose-volume histogram (DVH) are presented for simulated bolus thicknesses from 0 to 10 mm. Baseline HI values for all bolus thicknesses were in the 5.5 to 7.0 range, increasing to a maximum of 18.0 to 30.5 for the largest positioning errors when 0 to 2 mm of bolus is used. Utilizing 5 mm of bolus resulted in a maximum HI value of 9.5 for the largest positioning errors. Using 0 to 2 mm of bolus resulted in minimum and maximum dose values of 85% to 94% and 118% to 125% of the prescription dose, respectively. When using 5 mm of bolus these values were 98.5% and 109.5%. DVHs showed minimal changes in CTV dose coverage when using 5 mm of bolus, even for the largest positioning errors. CTV dose homogeneity becomes increasingly sensitive to errors in patient position as bolus thickness decreases when treating the scalp with primarily tangential beamlets. Performing a radial expansion of the scalp CTV into 5 mm of bolus material minimizes dosimetric sensitivity to errors in patient position as large as 5 mm and is therefore recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PERIOD ERROR ESTIMATION FOR THE KEPLER ECLIPSING BINARY CATALOG

The Kepler Eclipsing Binary Catalog (KEBC) describes 2165 eclipsing binaries identified in the 115 deg{sup 2} Kepler Field based on observations from Kepler quarters Q0, Q1, and Q2. The periods in the KEBC are given in units of days out to six decimal places but no period errors are provided. We present the PEC (Period Error Calculator) algorithm, which can be used to estimate the period errors of strictly periodic variables observed by the Kepler Mission. The PEC algorithm is based on propagation of error theory and assumes that observation of every light curve peak/minimum in a long time-series observation can be unambiguously identified. The PEC algorithm can be efficiently programmed using just a few lines of C computer language code. The PEC algorithm was used to develop a simple model that provides period error estimates for eclipsing binaries in the KEBC with periods less than 62.5 days: log {sigma}{sub P} Almost-Equal-To - 5.8908 + 1.4425(1 + log P), where P is the period of an eclipsing binary in the KEBC in units of days. KEBC systems with periods {>=}62.5 days have KEBC period errors of {approx}0.0144 days. Periods and period errors of seven eclipsing binary systems in the KEBC were measured using the NASA Exoplanet Archive Periodogram Service and compared to period errors estimated using the PEC algorithm.

79 ASTRONOMY AND ASTROPHYSICS↗

MAXIMUM LIKELIHOOD ANALYSIS OF SYSTEMATIC ERRORS IN INTERFEROMETRIC OBSERVATIONS OF THE COSMIC MICROWAVE BACKGROUND

We investigate the impact of instrumental systematic errors in interferometric measurements of the cosmic microwave background (CMB) temperature and polarization power spectra. We simulate interferometric CMB observations to generate mock visibilities and estimate power spectra using the statistically optimal maximum likelihood technique. We define a quadratic error measure to determine allowable levels of systematic error that does not induce power spectrum errors beyond a given tolerance. As an example, in this study we focus on differential pointing errors. The effects of other systematics can be simulated by this pipeline in a straightforward manner. We find that, in order to accurately recover the underlying B-modes for r = 0.01 at 28 < l < 384, Gaussian-distributed pointing errors must be controlled to 0. Degree-Sign 7 root mean square for an interferometer with an antenna configuration similar to QUBIC, in agreement with analytical estimates. Only the statistical uncertainty for 28 < l < 88 would be changed at {approx}10% level. With the same instrumental configuration, we find that the pointing errors would slightly bias the 2{sigma} upper limit of the tensor-to-scalar ratio r by {approx}10%. We also show that the impact of pointing errors on the TB and EB measurements is negligibly small.

79 ASTRONOMY AND ASTROPHYSICS↗

Rare events and Griffiths phases in topological quantum error correction

The performance of quantum error correcting (QEC) codes is often studied under the assumption of spatiotemporally uniform error rates. On the other hand, experimental implementations almost always produce heterogeneous error rates, in either space or time, as a result of effects such as imperfect fabrication and/or cosmic rays. It is therefore important to understand if and how their presence can affect the performance of QEC in qualitative ways. Here, in this work, we study the effects of nonuniform error rates in the representative examples of the 1D repetition code and the 2D toric code, focusing on when they have extended spatiotemporal correlations; these may arise, for instance, from rare events (such as cosmic rays) that temporarily elevate error rates over the entire code patch. These effects can be described in the corresponding statistical mechanics models for decoding, where long-range correlations in the error rates lead to extended rare regions of weaker coupling. For the 1D repetition code where the rare regions are linear, we find two distinct decodable phases: a conventional ordered phase in which logical failure rates decay exponentially with the code distance, and a rare-region dominated Griffiths phase in which failure rates are parametrically larger and decay as a stretched exponential. In particular, the latter phase is present when the error rates in the rare regions are above the bulk threshold. For the 2D toric code where the rare regions are planar, we find no decodable Griffiths phase: rare events which boost error rates above the bulk threshold lead to an asymptotic loss of threshold and failure to decode. Unpacking the failure mechanism implies that techniques for suppressing extended sequences of repeated rare events (which, without intervention, will be statistically present with high probability) will be crucial for QEC with the toric code.

classical statistical mechanics↗

Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm{sup 3} or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was consistently greater when using spherical tumor shapes as opposed to no shape assumption. However, an assumption of spherical tumor shape for RMSE = 3.5 mm led to a mean overestimation of tumor sampling probabilities of 3%, implying that assuming spherical tumor shape may be reasonable for many prostate tumors. The authors also determined that a biopsy system would need to have a RMS needle delivery error of no more than 1.6 mm in order to sample 95% of tumors with one core. The authors’ experiments also indicated that the effect of axial-direction error on the measured tumor burden was mitigated by the 18 mm core length at 3.5 mm RMSE. Conclusions: For biopsy systems with RMSE ≥ 3.5 mm, more than one biopsy core must be taken from the majority of tumors to achieveP ≥ 95%. These observations support the authors’ perspective that some tumors of clinically significant sizes may require more than one biopsy attempt in order to be sampled during the first biopsy session. This motivates the authors’ ongoing development of an approach to optimize biopsy plans with the aim of achieving a desired probability of obtaining a sample from each tumor, while minimizing the number of biopsies. Optimized planning of within-tumor targets for MRI-3D TRUS fusion biopsy could support earlier diagnosis of prostate cancer while it remains localized to the gland and curable.

60 APPLIED LIFE SCIENCES↗

SU-E-J-15: A Patient-Centered Scheme to Mitigate Impacts of Treatment Setup Error

Purpose: Current Intensity Modulated Radiation Therapy (IMRT) is plan-centered. At each treatment fraction, we position the patient to match the setup in treatment plan. Inaccurate setup can compromise delivered dose distribution, and hence leading to suboptimal treatments. Moreover, current setup approach via couch shift under image guidance can correct translational errors, while rotational and deformation errors are hard to address. To overcome these problems, we propose in this abstract a patient-centered scheme to mitigate impacts of treatment setup errors. Methods: In the patient-centered scheme, we first position the patient on the couch approximately matching the planned-setup. Our Supercomputing Online Replanning Environment (SCORE) is then employed to design an optimal treatment plan based on the daily patient geometry. It hence mitigates the impacts of treatment setup error and reduces the requirements on setup accuracy. We have conducted simulations studies in 10 head-and-neck (HN) patients to investigate the feasibility of this scheme. Rotational and deformation setup errors were simulated. Specifically, 1, 3, 5, 7 degrees of rotations were put on pitch, roll, and yaw directions; deformation errors were simulated by splitting neck movements into four basic types: rotation, lateral bending, flexion and extension. Setup variation ranges are based on observed numbers in previous studies. Dosimetric impacts of our scheme were evaluated on PTVs and OARs in comparison with original plan dose with original geometry and original plan recalculated dose with new setup geometries. Results: With conventional plan-centered approach, setup error could lead to significant PTV D99 decrease (−0.25∼+32.42%) and contralateral-parotid Dmean increase (−35.09∼+42.90%). The patientcentered approach is effective in mitigating such impacts to 0∼+0.20% and −0.03∼+5.01%, respectively. Computation time is <128 s. Conclusion: Patient-centered scheme is proposed to mitigate setup error impacts using replanning. Its superiority in terms of dosimetric impacts and feasibility has been shown through simulation studies on HN cases.

60 APPLIED LIFE SCIENCES↗