Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaporative cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A rocket-borne He-3 refrigerator

A self-contained, recyclable He-3 refrigerator suitable for use in space has been developed. The refrigerator is compact, has no moving parts, and requires only electrical connections and thermal contact in order to operate from a 2 K cold stage. A charcoal adsorption pump is used to efficiently condense and cool the He-3. Sintered copper confines the He-3 to the evaporator in zero-gravity and, in fact, allows the refrigerator to operate upside-down in the laboratory. Mounted on a 2 K cold stage, the refrigerator provides 100 microwatts of cooling power at 346 mK, with a 7 hour hold time. On a 1.5 K cold stage, the lowest temperature achieved is 277 mK. The refrigerator has been vibration tested at 7.5 G amplitude from 30 to 400 Hz and 15 G amplitude from 400 to 2000 Hz.

Duband, L.↗

Development of a solar-powered residential air conditioner: Screening analysis

Screening analysis aimed at the definition of an optimum configuration of a Rankine cycle solar-powered air conditioner designed for residential application were conducted. Initial studies revealed that system performance and cost were extremely sensitive to condensing temperature and to the type of condenser used in the system. Consequently, the screening analyses were concerned with the generation of parametric design data for different condenser approaches; i. e., (1) an ambient air condenser, (2) a humidified ambient air condenser (3) an evaporative condenser, and (4) a water condenser (with a cooling tower). All systems feature a high performance turbocompressor and a single refrigerant (R-11) for the power and refrigeration loops. Data were obtained by computerized methods developed to permit system characterization over a broad range of operating and design conditions. The criteria used for comparison of the candidate system approaches were (1) overall system COP (refrigeration effect/solar heat input), (2) auxiliary electric power for fans and pumps, and (3) system installed cost or cost to the user.

Source record↗

A numerical investigation of the severe thunderstorm gust front

The structure of the thunderstorm gust front is investigated by a nonhydrostatic, two-dimensional (x,z) numerical model. In the model, which is dry, the production of negatively buoyant air by evaporation is parameterized via an externally imposed, local-cooling function. This parameterization sustains a steady cold downdraft, which drives the surface outflow and associated gust front. It is shown that two dominant factors influencing gust front structure in the vertical plane are the solenoidal field coincident with the front and surface friction, modeled by means of a simple bulk aerodynamic drag formulation. The circulation theorem is invoked to illustrate how solenoidal accelerations oppose the deceleration by surface friction. After the onset of a downdraft in the model, these opposing tendencies soon reach a balance. Thus, following a brief transient stage, the model gust front exhibits a persistent configuration as it propagates rapidly forward. The essential features of this configuration are examined and compared with both tower observations of gust fronts and laboratory models of gravity currents.

Mitchell, K. E.↗

Tropical sea surface temperature - An interactive one-dimensional atmosphere-ocean model

It is shown that the (cumulus) convective processes in the tropics may be described by a one-dimensional cloud model, while the near-surface ocean may similarly be described by a one-dimensional mixed-layer model. The coupling is achieved through a sea surface flux budget combined with the flux parameterizations implied by Monin-Obukhov similarity theory. The coupled one-dimensional atmosphere-ocean model is applied to the equilibrium situation in which all temperatures reach a steady state. For the ocean, the fluxes must vanish in equilibrium, but the atmosphere maintains a stable lapse rate by balancing cumulonimbus heating against net radiative cooling. All water precipitating from cumulonimbus clouds must have evaporated from the sea. It is shown that this equilibrium system is closed and determinable solely in terms of the solar constant.

Sarachik, E. S.↗

Idealized model for stratocumulus cloud layer thickness

Equilibrium solutions are constructed using an idealized model for mixed and partially mixed boundary layers to show the dependence of the equilibrium cloud layer thickness on different physical processes. The condition when a mixed layer becomes cloud-free is reduced to a comparison between three pressure scales, associated with the surface wind and divergence, the radiative cooling and the subsaturation of the entrained air. The evaporation of layer cloud by cloud-top mixing is also formulated in terms of simple pressure scales.

Betts, Alan K.↗

Numerical simulation of X-ray-heated winds in Seyfert galaxies. I - The case of zero angular momentum

Numerical hydrodynamics simulations are presented of X-ray heated winds believed to form the 'mirrors' which reflect light from obscured Seyfert galaxy nuclei into our line of sight. Above a likely range of parameters, it is shown that steady state flows are created when a cool torus surrounds an AGN. Some of the mass evaporated off the inner edge of the torus is captured by the central gravitational well, while the rest is driven off in a warm wind. When the central gravity is strong relative to the radiative heating rate, i.e., L/L(E) is small, nearly all the injected matter is captured. When the gravity is weaker, a given combination of heating rate and injected pressure leads to a maximum mass loss rate; when the rate at which mass is injected exceeds this amount, the excess is captured. The dividing line between these two cases comes at L/L(E) = about 0.08.

Balsara, Dinshaw S.↗

Development of a Battery-Free Solar Refrigerator

Recent technology developments and a systems engineering design approach have led to the development of a practical battery-free solar refrigerator as a spin-off of NASA's aerospace refrigeration research. Off-grid refrigeration is a good application of solar photovoltaic (PV) power if thermal storage is incorporated and a direct connection is made between the cooling system and the PV panel. This was accomplished by integrating water as a phase-change material into a well insulated refrigerator cabinet and by developing a microprocessor based control system that allows direct connection of a PV panel to a variable speed compressor. This second innovation also allowed peak power-point tracking from the PV panel and elimination of batteries from the system. First a laboratory unit was developed to prove the concept and then a commercial unit was produced and deployed in a field test. The laboratory unit was used to test many different configurations including thermoelectric, Stirling and vapor compression cooling systems. The final configuration used a vapor compression cooling cycle, vacuum insulation, a passive condenser, an integral evaporator/ thermal storage tank, two 77 watt PV panels and the novel controller mentioned above. The system's only moving part was the variable speed BD35 compressor made by Danfoss. The 365 liter cabinet stayed cold with as little as 274 watt-hours per day average PV power. Battery-free testing was conducted for several months with very good results. The amount of thermal storage, size of compressor and power of PV panels connected can all be adjusted to optimize the design for a given application and climate. In the commercial unit, the high cost of the vacuum insulated refrigerator cabinet and the stainless steel thermal storage tank were addressed in an effort to make the technology commercially viable. This unit started with a 142 liter, mass-produced chest freezer cabinet that had the evaporator integrated into its inner walls. Its compressor was replaced with a Danfoss DC compressor slightly larger than the one used in the laboratory unit. The control system was integrated onto a single electronics card and packaged with its starting capacitors. The water for thermal storage was placed behind a liner that was made to fit inside the original factory liner. The original condenser was also augmented with additional surface area to improve performance. PV panels with a total rated power of 180 watts were used. The unit was tested with very successful results in an outside ambient environment, demonstrating its potential for widespread use in many off-grid applications for solar refrigeration.

Ewert, Michael K.↗

SERFE Project Overview

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is underdevelopment to support missions to the International Space Station (ISS) and also to the Moon. Improvements in the life and robustness of the Portable Life Support System (PLSS) has been a major objective of these efforts. The Suit Water Membrane Evaporator (SWME) was chosen as the technology to provide cooling to the xEMU and has undergone several iterations of development over this period. An ISS flight experiment centered around the SWME and other thermal loop technologies was developed and has been under test in an ISS EXpedite PRocessing of Experiments to the Space Station (EXPRESS) rack since November of 2020. In addition to the SWME, The SWME EXPRESS Rack Flight Experiment (SERFE) contains several technology demonstrations from the xEMU project and has been demonstrating their performance in micro-gravity and over an extended duration. This paper summarizes the design and operation of the SERFE experiment and provides a basis for subsequent papers to focus on more specific aspects of performance of individual technologies.

SERFE↗

SERFE Thermal Performance Results

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is underdevelopment to support missions to the International Space Station (ISS) and also to the Moon. Improvements in the life and robustness of the Portable Life Support System (PLSS) has been a major objective of these efforts. The Suit Water Membrance Evaporator (SWME) was chosen as the technology to provide cooling to the xEMU and has undergone several iterations of development over this period. An ISS flight experiment centered around the SWME and other thermal loop technologies was developed and has been under test in an ISS EXpedite PRocessing of Experiments to the Space Station (EXPRESS) rack since November of 2020. In addition to the SWME, The SWME EXPRESS Rack Flight Experiment (SERFE) contains several technology demonstrations from the xEMU project and has been demonstrating their performance in micro-gravity and over an extended duration. In addition to the SWME, these include two dissimilar water pumps, custom check valves, custom bypass relieve valves, a custom thermal control valve, development pressure and temperature sensors, and the Thermal Loop Controller. This paper presents thermal and fluids testing results of the system as a whole and of key components.

SERFE↗

SERFE Water Quality Results

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is underdevelopment to support missions to the International Space Station (ISS) and also to the Moon. Improvements in the life and robustness of the Portable Life Support System (PLSS) has been a major objective of these efforts. Water quality, and how that impacts the performance of the life support system hardware, are areas where improvements could greatly help to achieve these goals. The Suit Water Membrane Evaporator (SWME) was chosen as the technology to provide cooling to the xEMU and has undergone several iterations of development over this period. An ISS flight experiment centered around the SWME and other thermal loop technologies was developed and has been under test in an ISS EXpedite PRocessing of Experiments to the Space Station (EXPRESS) rack since November of 2020. In addition to the SWME, The SWME EXPRESS Rack Flight Experiment (SERFE) contains several technology demonstrations from the xEMU project and has been demonstrating their performance in micro-gravity and over an extended duration. This paper will summarize the results of the water quality analysis performed to date throughout the SERFE testing program. Special care was taken to select materials, process hardware, and control the quality of the feedwater used in SERFE testing so that it would be representative of a thermal control system that could be used on a spacesuit for a lunar mission. In addition, the testing schedule, including periods of quiescence in between tests, was also selected to simulate a real mission profile in ways that would be critical to water quality. Results include data and analysis on microbial activity, biocidal iodine, metals, organic carbon, and several other customary indicators of water quality in an operational system. Testing spans over a year and a half of wetted life of the SERFE Flight Unit and the SERFE Ground Unit.

Colin Campbell↗

SERFE PLSS Component Lessons Learned from ISS

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is under development to support missions to the International Space Station (ISS) and also to the Moon. Improvements in the life and robustness of the Portable Life Support System (PLSS) has been a major objective of these efforts. The Suit Water Membrane Evaporator (SWME) was chosen as the technology to provide cooling to the xEMU and has undergone several iterations of development over this period. An ISS flight experiment centered around the SWME and other thermal control loop (TCL) technologies was developed and tested in an ISS EXpedite PRocessing of Experiments to the Space Station (EXPRESS) rack from November of 2020 to August of 2022. In addition to the SWME, the SWME EXPRESS Rack Flight Experiment (SERFE) contains several technologies from the xEMU project and demonstrated their performance in micro-gravity and over an extended duration. These included two dissimilar water pumps, custom check valves, custom bypass relieve valves, a custom thermal control valve, development pressure and temperature sensors, and the thermal loop controller. This paper presents PLSS component lessons learned after return of the SERFE flight unit in August of 2022. The SERFE team took the flight unit apart and handed hardware components over to hardware owners to see how parts of the TCL managed after almost 2 years on the ISS and 25 simulated EVAs (Exploration Extravehicular Activity) on orbit. The team performed inspection, testing, and analysis and provided lessons learned on PLSS components for NASA’s prototype spacesuit. This analysis included how well SWME maintained its heat rejection capability, as well as looked at the robustness of the other TCL hardware.

SERFE↗

SERFE PLSS Component Lessons Learned from ISS

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is under development to support missions to the International Space Station (ISS) and also to the Moon. Improvements in the life and robustness of the Portable Life Support System (PLSS) has been a major objective of these efforts. The Suit Water Membrane Evaporator (SWME) was chosen as the technology to provide cooling to the xEMU and has undergone several iterations of development over this period. An ISS flight experiment centered around the SWME and other thermal control loop (TCL) technologies was developed and tested in an ISS EXpedite PRocessing of Experiments to the Space Station (EXPRESS) rack from November of 2020 to August of 2022. In addition to the SWME, the SWME EXPRESS Rack Flight Experiment (SERFE) contains several technologies from the xEMU project and demonstrated their performance in micro-gravity and over an extended duration. These included two dissimilar water pumps, custom check valves, custom bypass relieve valves, a custom thermal control valve, development pressure and temperature sensors, and the thermal loop controller. This paper presents PLSS component lessons learned after return of the SERFE flight unit in August of 2022. The SERFE team took the flight unit apart and handed hardware components over to hardware owners to see how parts of the TCL managed after almost 2 years on the ISS and 25 simulated EVAs (Exploration Extravehicular Activity) on orbit. The team performed inspection, testing, and analysis and provided lessons learned on PLSS components for NASA’s prototype spacesuit. This analysis included how well SWME maintained its heat rejection capability, as well as looked at the robustness of the other TCL hardware.

SERFE↗

Implications of Advanced Crew Escape Suit Transpiration for the Orion Program

Human testing was conducted to more fully characterize the integrated performance of the Advanced Crew Escape Suit (ACES) with liquid cooling provide by an Individual Cooling Unit (ICU) across a broad range of environmental conditions and metabolic rates. Together with a correlation for the ACES Liquid Cooling Garment as a function of inlet temperature, metabolic rate, and crew size, a reasonably conservative correlation for core temperature was achieved for the human thermal model applied to the ACES with ICU cooling. A key observation for this correlation was accounting for transpiration of evaporated sweat through the Gortex(Registered TradeMark) liner of the ACES indicated by as much as 0.6 lbm of sweat evaporated over the course of the 1 hour test profile, most of which could not be attributed to respiration or head sweat evaporation of the crew. Historically it has been assumed that transpiration was not an important design feature of the ACES suit. The correlated human thermal model will show transpiration to be highly useful in hot survival situations for the Orion Program when adequate liquid cooling is not available.

Bue, Grant↗

Flare loop radiative hydrodynamics. IV - Dynamic evolution of unstable semiempirical loop models

The evolution of the unstable solar atmosphere into the nonlinear phase, in response to various perturbations, is followed. The initial dynamic evolution of the atmosphere follows the predictions of linear stability analysis. In the nonlinear phase, rapid changes are confined to the transition region; these changes are manifested as a propagation of the transition region through the plasma, i.e., chromospheric evaporation or condensation. Global evolution therefore proceeds on the coronal conductive time scale. The rate of propagation of the transition region is determined by the imbalance between the energy supplied by thermal conduction from the corona and radiative cooling within the transition region itself. Flow velocities in the lower corona during evaporation or condensation are, in the cases studied, of order 3 km/s. The observed dynamic evolution is consistent with the existence of relatively long-lived coronal loops whose brightnesses vary on the evaporative time scale.

An, C.-H.↗

Petrographic Evidence for Rapid Heating and Cooling During Chrondrule Formation

The chondrule cooling rates used in most chondrule-formation models appear to be too low. Recent petrographic evidence indicates that the amount of crystal (especially olivine) growth that occurred after the last melting event was about 30 smaller than the grain sizes simulated in order to estimate cooling rates. The smaller amount of growth leads to an upwards revision of cooling rates by about a factor of 1000. Most chondrules are porphyritic. They consist of large and small crystals of olivine and, less commonly, pyroxene immersed in a mesostasis having a plagioclase-rich composition. In the most primitive chondrites the mesostasis is often vitreous. Because the large majority of chondrules contain FeS, it is clear that the nebula had cooled below the FeS condensation temperature (ca. 650 K) before chondrule formation occurred. The high FeO/(FeO+MgO) ratios of some chondrules require still lower nebular temperatures (less than 500 K). The traditional view has been that porphyritic chondrules formed in a single heating/cooling event and many laboratory experiments have been carried out in various kinds of kinds of furnaces to try to simulate the formation of chondrules textures in a single heating/cooling cycle. These furnace experiments have been used to infer the cooling rates of chondrules during the temperature range at which olivine crystallized from the melt. Most of these inferred values are in the range 0.01-1 K per second. These low cooling rates are problematical because there is no long-term nebular environment that yields such values. In transparent regions chondrules would cool at rates orders of magnitude higher, whereas in an opaque nebular disk the cooling rates would be many orders of magnitude lower. And these latter conditions are not suitable locations for chondrule formation because such high temperatures would cause the complete evaporation of chondrules (which have melting temperatures about 600 K higher than their evaporation temperatures). During the last several years several kinds of petrographic evidence indicating rapid chondrule cooling have been recognized. These include thin overgrowths on relict grains, clusters of small crystals that grew following the most recent melting event, and fragments preserving shardlike shapes that would have been hidden had several tens of micrometers of new growth occurred following the last melting event. And there are other indications of rapid cooling including the preservation of volatiles such as FeS and one case where the modeling of O-isotopic and FeO/(FeO+MgO) gradients indicated a high cooling rate.

Wasson, J. T.↗

Capillary pumped loop body heat exchanger

A capillary pumped loop for transferring heat from one body part to another body part, the capillary pumped loop comprising a capillary evaporator for vaporizing a liquid refrigerant by absorbing heat from a warm body part, a condenser for turning a vaporized refrigerant into a liquid by transferring heat from the vaporized liquid to a cool body part, a first tube section connecting an output port of the capillary evaporator to an input of the condenser, and a second tube section connecting an output of the condenser to an input port of the capillary evaporator. A wick may be provided within the condenser. A pump may be provided between the second tube section and the input port of the capillary evaporator. Additionally, an esternal heat source or heat sink may be utilized.

Swanson, Theodore D.↗

Lunar Portable Life Support System Heat Rejection Study

Performing extravehicular activity (EVA) at various locations of the lunar surface presents thermal challenges that exceed those experienced in space flight to date. The lunar Portable Life Support System (PLSS) cooling unit must maintain thermal conditions within the space suit and reject heat loads generated by the crewmember and the PLSS equipment. The amount of cooling required varies based on the lunar location and terrain due to the heat transferred between the suit and its surroundings. A study has been completed which investigated the resources required to provide cooling under various lunar conditions, assuming three different thermal technology categories: 1. Spacesuit Water Membrane Evaporator (SWME) 2. Subcooled Phase Change Material (SPCM) 3. Radiators with and without heat pumps Results from the study are presented that show mass and power impacts on the cooling system as a function of the location and terrain on the lunar surface. Resources (cooling equipment mass and consumables) are greater at the equator and inside sunlit craters due to the additional heat loads on the cooling system. While radiator and SPCM technologies require minimal consumables, they come with carry-weight penalties and have limitations. A wider investigation is recommended to determine if these penalties and limitations are offset by the savings in consumables.

Conger, Bruce↗

Cooling by conversion of para to ortho-hydrogen

The cooling capacity of a solid hydrogen cooling system is significantly increased by exposing vapor created during evaporation of a solid hydrogen mass to a catalyst and thereby accelerating the endothermic para-to-ortho transition of the vapor to equilibrium hydrogen. Catalyst such as nickel, copper, iron or metal hydride gels of films in a low pressure drop catalytic reactor are suitable for accelerating the endothermic para-to-ortho conversion.

Sherman, A.↗