Polysulfide entrapment and retardation in gel electrolyte Li–S batteries: experiments and modeling

Gelling the electrolyte in lithium–sulfur (Li–S) batteries provides advantages in terms of safety and mitigating polysulfide shuttling leading to reduced side reactions and dendrite growth on the anode side. In the current study, organic and ceramic crosslinkers have been used to improve the entrapment of polysulfides and prevent them from shuttling to the anode side. However, the performance of gel electrolytes is still far from being on par with liquid electrolytes in terms of raw capacity. The discharge curves exhibit an extended first plateau for gel electrolyte batteries compared to liquid electrolytes, showing that polysulfides are better trapped in the gel system. Yet, in the conversion of soluble polysulfides into insoluble polysulfides, the second plateau was delayed. Qualitative and quantitative analysis of the polysulfide diffusion in the liquid electrolyte and gel electrolyte systems were also conducted to predict the relative diffusivity ratio between the liquid electrolyte and gel electrolyte for simulation. To probe what happens at the end of the discharge, where the mass transport in the gel electrolyte appears to be slow, a modified discharge procedure was used where the cell is first paused after discharge and then discharged a second time before recharging normally. Coin cell tests for two gel electrolytes in addition to liquid electrolyte show up to 7% capacity recovery after the pause, which indicates that the diffusion of species during the pause is responsible for the failure recovery. Additionally, the recovery is higher for gel electrolytes compared to liquid, for higher C-rates, and for longer pause times. To better understand this behavior, a Li–S numerical model with mass transport limited reactions was used to examine the polysulfide diffusion coefficients expected in different electrolyte systems. The model is able to reproduce the trends seen in experiments and yields a higher recovery for smaller Li 2 S 4 diffusion coefficients, suggesting that insufficient Li 2 S 4 mass transport is responsible for failure at the end of discharge. By identifying the effect that gel electrolytes have on the state of the battery during discharge using both experimental and simulation methods, this work is a step towards leveraging the advantages of gel electrolytes and mitigating their weaknesses.

25 ENERGY STORAGE↗

An Improved Transmission Switching Algorithm for Managing Post-(N-1) Contingencies in Electricity Networks

In this presentation, we detail the shortcomings of existing transmission switching (TS) methodologies for preventing post-contingency loss of load in wide area electric power networks. Following that, we present a bi-level algorithm as an improvement to the state of the art. We show proof-of-concept level results that indicate computational viability, fast solutions, and the ability to pick the same best candidate as non computationally viable methods. Further, our method also minimizes load shedding after the contingency, thus enhancing the reliability and security of electricity supply. We also include a futuristic scenario of increased renewables and decreased natural gas sourced generators to show promising results. We grant permission for our presentation to be recorded and uploaded by the conference organizers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AGC-4 Experiment Irradiation Monitoring Data Qualification Final Report

The Graphite Technology Development Program ran a series of six experiments to quantify the effects of irradiation on nuclear grade graphite. This report focuses on the fourth experiment, Advanced Graphite Creep 4 (AGC 4). The Advanced Reactor Development (ARD) Technology Development Office (TDO) Program for research and development activities require documentation of qualified monitoring data to design and license the first high-temperature reactor nuclear plant. Qualified data meets the requirements for use as described in the experiment planning and quality assurance documents. Failed data do not meet the requirements and provide no useable information. Trend data may not meet all requirements but still provide some useable information. Use of Trend data requires assessment of how any deficiencies affect a particular use of the data. AGC-4 began with Advanced Test Reactor (ATR) Cycle 157D on May 30, 2015. After irradiating the graphite for two cycles, the capsule was removed from the reactor after ATR Cycle 158A, which ended on January 2, 2016, due to interference with another experiment. Irradiation was resumed with Cycle 162A on October 7, 2017 after the interfering experiment was removed from the reactor. AGC-4 irradiation completed by the end of Cycle 166B on January 10, 2020. Between Cycles 162A and 166B, AGC-4 capsule was removed from the reactor core during two Powered Axial Locator Mechanism (PALM) Cycles 163A and 165A to avoid overheating. All thermocouples (TCs) have functioned throughout the AGC-4 experiment. A total of 9,256,184 out of all 11,167,213 temperature records (or 82.9%) are Qualified for use by the ARD Program and 1,911,029 missing values are Failed. Argon, helium, and total gas flow data were within expected ranges, except only eight out-of-range values occurred during outages. A total of 21,240,627 out of all 22,288,5103 gas flow rates (or 92.8%) are Qualified for use by the ARD Program and 1,644,476 are Failed records mostly due to missing values. Discharge gas line moisture values were consistently low during full ATR power, except for 162B, when moisture content was increasing to more than 200 ppmv by the end of this cycle. During outages, moisture content reached as high as 700 ppmv. 1,089,941 out of a total of 1,107,331 moisture values (or 98.4%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 17,390 missing moisture values are Failed. Graphite creep specimens were subjected to one of three loads: 393, 491, or 589 lbf. For a brief period during Cycle 157D between 12:19 on June 2, 2015, and 08:23 on June 11, 2015, the load cells were wired incorrectly, resulting in missing stack load data. Missing stack loads were estimated from measured ram pressures using regression equations developed from the existing data from Cycle 157D. Estimated stack loads during this period are considered to be an accurate representation of actual load applied to the stacks. These loads deviate slightly from the planned loads. This deviation does not prevent the data from being Qualified for use but must be taken into account when analyzing the effect of load on creep. 6,095,728 out of a total of 6,403,985 moisture values (or 95.2%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 308,257 missing load values are Failed. Stack displacement increased consistently throughout the eight cycles, with total displacement reached highest value of 2.4 in by the end of irradiation. During ATR outages, a set of pneumatic rams raised the stacks of graphite creep specimens to ensure the specimens were not stuck within the test train. This stack raising was performed seven times throughout irradiation. All stacks were raised successfully each time. 4,744,974 out of a total of 6,094,513 displacement values (or 77.9%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 1,349,539 displacement values are Failed mostly due to missing values. Analyses were conducted on correlations between TCs to look for trends and step changes that might indicate instrument degradation or failure. Correlation analysis was used to identify instances when TCs form short circuits, referred to as virtual junctions, which result in TCs reporting temperatures from some location in the capsule other than the location where they were intended to read. No evidence of virtual junctions was found. Analyses were also conducted on control charts of temperature differences of between two TCs, which are expected to behave consistently throughout the entire irradiation period. Upward or downward trend over time indicates at least one TC in the pair was drifted. Examining control charts for all 66 possible pairs out of twelve TCs installed in the AGC-4 capsules reveal no clear drift failures occurred, except unstable behavior of two TCs in Zone 3, TC-7 and TC-8, over irradiation time. In conclus

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Wireless Sensing and Communication Capability from In-Core to a Monitoring Center

Significant cost savings can be made if electrical cables can be replaced by wireless technology in current Nuclear Power Plants (NPP) and in advance reactor designs. Wireless technology can also provide in-core opportunities by significantly reducing the number of penetrations in the pressure vessel, cost and complexity of sensor installation and by increasing the efficiency of current and advanced reactors. Unlike other deployment scenarios for an industrial environment, operators need to have centralized control over all the networks. Centralized control will reduce implementation costs, provide single point control and enable monitoring of network devices, improve security, and enhance connectivity. Micro-sensors that can simultaneously monitor temperature and pressure within a fuel rod inside nuclear reactors will enable preventative actions during abnormal operating conditions. This ability could avert accidents and enable the expedient development of accident tolerant fuels. A novel micro-sensor suite (~ mm) to simultaneously measure multiple parameters such as temperature, strain, pressure, and neutron/gamma flux inside a fuel rod is being developed for use in reactors. The necessary communication architecture is also being developed to transmit measurement signals from the core to the plant's data cloud or control room. A three three-tier strategy has been developed to support wireless transmission of in-core measurements to the control room or to a secure cloud platform for control, analytics, and decision-making purposes. 1. In-core: data signal from in-core to outside of the pressure vessel within the containment building 2. Containment building: data signal from inside to the outside of the containment building and into the balance of the plant network 3. Balance of the plant network: information transmitted to the data cloud and control room This plan presents a wireless sensing and communication system for use within a reactor core and elsewhere. The communication technology is advantageous to compensate for network equipment failures and adverse data transmission conditions. Wireless technology will significantly increase the resiliency of the plants network system. The wireless system naturally provides multiple transmission path capability and data redundancy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytics-at-scale of Sensor Data for Digital Monitoring in Nuclear Plants (4th Annual Report)

Nuclear plant sites collect and store large volumes of data collected from various equipment and systems. These datasets typically include plant process parameters, maintenance records, technical logs, online monitoring data, and equipment failure data. The collection of such data affords an opportunity to leverage data-driven machine learning and artificial intelligence technologies to provide diagnostic and prognostic capabilities within the nuclear power industry to reduce operating and maintenance costs. In this way, nuclear energy can become more economically competitive with other energy sources, and premature closures can be avoided. From a maintenance standpoint, savings can be achieved by leveraging machine learning and artificial intelligence technologies to develop data-driven algorithms to better diagnose and predict potential faults within the system. Improved model accuracy can lead to reductions in unnecessary maintenance and more efficient planning of future maintenance, thus lowering the costs associated with parts, labor, and unnecessary planned, forced, or extended outages. From an operations perspective, cost savings can be generated by shifting from route-based monitoring to wireless technologies for online monitoring, and by transitioning from onsite- to cloud-based computing and storage services. Wireless monitoring would reduce the operator manhours required for taking routine measurements, while cloud computing services would generate cost savings by reducing the amount of hardware needing to be purchased and maintained—all while scaling to both computational and storage demands. This report summarizes this project’s effort to shift from costly, labor-intensive preventative maintenance to cheaper predictive maintenance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solar Photovoltaics Resilient Fasteners Levelized Cost of Energy (LCOE) Tool

Solar photovoltaics (PV) module fasteners are one of the most common structural failure points on PV systems, particularly in high winds and coastal areas with ocean spray. Some fastener types have been shown to survive these conditions at higher rates than others. The fastener type, material, quantity, and placement all impact performance. Fasteners that fail less often typically have a higher upfront cost, but this investment can pay off in savings from less frequent torque audits (which reduces O&M costs), reduced system damage, and decreased system downtime. We developed an Excel-based tool to evaluate different module fasteners for a PV system - either a new or retrofit project - and compare differences in upfront and outyear costs to determine the expected life cycle costs and simple payback periods of different fastener options. The tool is site-specific, with inputs including system attributes (such as system size, location, price of power) and fastener attributes (such as design, washer type, nut type, use of locking hardware, materials, installation time, and torque audit requirements). A baseline fastener scenario can be compared to up to four proposed fastener scenarios. In addition to presenting expected life cycle cost implications of the different fastener options, the tool produces results showing the reductions in outyear costs needed to offset any initial cost premiums for more reliable fasteners across four categories: preventative O&M, avoided damage, reduced downtime, and reduced insurance premiums. These numbers can serve as decision aids for users when considering fastener options on new or existing projects. This poster will present the tool, methodology, and scenarios using example sites to highlight the tool capabilities and how it can inform different fastener decisions on different projects. Future work includes incorporating lifetime expected damage costs by embedding damage function curves that the authors are developing from field data.

14 SOLAR ENERGY↗

Monte Carlo Dropout Uncertainty Quantification of Long Short-Term Memory Autoencoder Anomaly Detection in a Liquid Sodium Cold Trap

Advanced high-temperature fluid reactors, such as sodium-cooled fast reactors (SFRs) and molten salt–cooled reactors (MSCRs), require coolant purification systems to prevent fluid contamination and local freezing that can lead to plugging. Liquid sodium purification can be achieved with a cold trap, where the sodium temperature is reduced to a near-freezing point to precipitate out impurities. Automation of monitoring of the cold trap performance with machine learning algorithms can aid in early detection of incipient anomalies. An efficient approach to loss-of-coolant–type anomaly detection in a cold trap monitored with more than two dozen thermal-hydraulic sensors consists of a long short-term memory (LSTM) autoencoder. This work develops the uncertainty quantification of the LSTM autoencoder performance for cold trap anomaly detection using the Monte Carlo (MC) dropout method. The MC dropout methodology creates a distribution of sister distributions that all slightly differ from each other because of random neurons being turned off for testing. The variances of the sister network distributions are used to make an uncertainty interval. Our analysis shows that the uncertainty in the autoencoder performance is largest near the peak of the anomaly signal. Using the MC dropout method, we investigate the uncertainty in the anomaly detection with missing sensor inputs. This capability allows the reactor operator to evaluate resilience of the anomaly detection system and to make informed decisions about continuity of operation in the event of sensor failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-Burnup BWR LOCA Burst Analysis Framework Development and Demonstration

Nuclear power currently contributes approximately 20% of total electricity generation in the United States and more than 10% globally. Given the increasing reliance on nuclear energy to achieve our nation’s goal of reaching net-zero carbon emissions by 2050, there is significant pressure on the existing nuclear industry to extend plant operational licenses and improve efficiency. This is crucial as the existing nuclear fleet serves as a vital bridge until new light water and advanced reactors can be developed and deployed, bolstering the supply of carbon-free energy to meet domestic demands. Operational costs primarily consist of plant operation and maintenance and fuel costs, influenced by materials and reactor core designs. These factors, coupled with heavily subsidized renewable energy markets, create a challenging economic environment for the existing light water reactor fleet, as well as for new build projects. To address these economic challenges, the nuclear industry has developed a strategic blueprint aimed at enhancing nuclear power’s economic sustainability. Past initiatives, such as efforts to eliminate fuel failures by 2010 and reduce operating costs by 30% before 2020, have laid the groundwork. Optimizing core design parameters, including burnup limits and enrichment levels, can lengthen cycles, reduce outages, reduce batch reload batch fractions and spent fuel storage requirements, and lower maintenance and operating expenses, thereby enhancing economic viability. In the United States, boiling water reactors (BWRs) comprise approximately one-third of the fleet, although much of the research and development focus has traditionally been on pressurized water reactors (PWRs). Advances in modeling and simulation, particularly through the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, are crucial to the long-term viability of BWRs, just as they are for PWRs. A key research area of the high burnup/increased enriched fuel initiative is focused on addressing loss-of-coolant-accident (LOCA)-related issues. NEAMS has dedicated significant effort to enhancing tools to better support BWRs, with a current focus on showcasing the BWR framework for high-burnup LOCA analysis. This high-fidelity work will demonstrate a best estimate pin-by-pin high-burnup BWR LOCA analysis to assess full-core cladding rupture behavior. This modeling capability will help with better understanding and realistic evaluation of fuel fragmentation, relocation, and dispersal (FFRD) phenomena at BWRs, which then could be used to prevent FFRD at BWRs without penalizing operational parameters. In addition, the results of this work will help identify strategies to identify additional margins or to potentially limit cladding rupture through core design optimizations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An Operational Resilience Metric for Modern Power Distribution Systems

The electrical power system is the backbone of our nations critical infrastructure. It has been designed to withstand single component failures based on a set of reliability metrics which have proven acceptable during normal operating conditions. However, in recent years there has been an increasing frequency of extreme weather events. Many have resulted in widespread long-term power outages, proving reliability metrics alone do not provide adequate energy security. As a result, researchers have focused their efforts on a new set of metrics based on the concept of resilience to ensure efficient operation of power systems during extreme events. A resilient system has the ability to resist, adapt, and recover from disruptions. Therefore, resilience has demonstrated itself as a promising concept for currently faced challenges in power distribution systems. In this work, we propose a real-time resilience metric for modern power distribution systems. The metric is an aggregation of the controllable assets adaptive capacity, or their temporal flexibility in real and reactive power. This metric gives information to the magnitude and duration of a disturbance which the system can respond to without having to drop loads or have stability issues in voltage or frequency. We demonstrate the impact to resilience in a case study under normal operation and during a power contingency on a microgrid. In the future, this information can be used by operators to make more informed decisions based on system resilience in an effort to prevent power outages.

42 ENGINEERING↗

Characterization of modeling and experimental data inconsistencies from burst testing for high-burnup commercial fuel rod applications

Fuel fragmentation, relocation, and dispersal are some of the largest issues remaining in the nuclear industry before rod-average burnup can be increased beyond 62 GWd/tU. The issue is primarily related to the potential for fuel to be dispersed into the reactor primary system, which may increase public risk. One way to prevent dispersal is to avoid cladding burst. The objective of this work is to support the high burnup safety case by evaluating cladding burst under high-burnup, full-length fuel rods and to identify uncertainties that could improve model predictions. The results of this analysis will evaluate realistic, prototypic loss-of-coolant accident (LOCA) conditions; support future cladding burst test designs; and inform the development of mechanistic material models. Realistic high-burnup operating conditions were implemented in the BISON fuel performance code to simulate steady-state and LOCA transient fuel rod evolution to the point at which cladding burst occurred. Parametric studies are performed to assess code response to changes in rod internal pressures and heating rates. Results were compared with simulated LOCA experiments to identify inconsistencies between commercial fuel rod analysis and experimental validation. The representative full-length fuel rod LOCA simulation results did not agree with cladding burst tests. Cladding burst tests indicated burst occurring well below (100–150 °C) those calculated in the full-length fuel rod LOCA analysis. Further investigation indicated that the cladding burst tests do not appear to be representative for full-length fuel rods. The inconsistency investigated in this work showed that the differences between the BISON simulation and the experiment's cladding burst conditions arise from an incomplete characterization of the cladding surface temperature, detailed rodlet characterization, lack of cladding strain measurements, and uncertainty in the cladding creep and failure models.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Human papillomavirus–associated anal squamous cell carcinoma: sociodemographic, geographic, and county-level economic trends in incidence rates—United States, 2001-2019

Abstract Background Incidence of anal squamous cell carcinoma is increasing, but vaccination against human papillomavirus (HPV) and removal of precancerous anal lesions could prevent new cases. The overall HPV-associated cancer incidence is reported to be higher in rural populations and in counties with lower economic status. We assessed these differences specifically for HPV-associated anal squamous cell carcinoma and described the geographic, county-level economic, and sociodemographic variations in incidence rates and trends. Methods We analyzed data from the US Cancer Statistics to assess age-standardized incidence rates of HPV-associated squamous cell carcinomas among adults aged 18 years and older from 2001 to 2019. We calculated rate ratios and 95% confidence intervals to examine differences in incidence rates. We also quantified changes in incidence rates over time using joinpoint regression. Results From 2001 to 2019, 72 421 new cases of HPV-associated anal squamous cell carcinoma were diagnosed among women (2.8 per 100 000) and 37 147 among men (1.7 per 100 000). Age-standardized incidence rates were higher in the South compared with other census regions and in counties ranked in the bottom 25% and 25%-75% economically than in the top 25%. The overall incidence rate increased in women but remained stable in men during 2009-2019. Incidence rates increased in adults aged 50 years and older but decreased among those aged 40-44 years from 2001 to 2019 in women and from 2007 to 2019 in men. Conclusions There were inequities in HPV-associated anal squamous cell carcinoma incidence by geographic and county-level economic characteristics. Failure to improve vaccine and treatment equity may widen existing disparities.

Oncology↗

Electrolyte and Cutoff Potential Effects on Cycle Life of Li4Ti5O12/LiNi0.9Mn0.1O2 Batteries for Behind-the-Meter Storage Applications

Behind-the-Meter Storage (BTMS) is a stationary battery energy storage system that is connected to the electrical distribution system on the customer's side of the utility's service meter. BTMS systems are used to store electrical energy from the grid as well as inconstant, renewable energy, such as local solar and wind generation. A successful BTMS system will allow the customer to pair their energy generation and storage to optimize electrical consumption from the grid, improving reliability and minimizing cost. For BTMS applications, batteries must be designed and optimized with different set of criteria from other leading segments of the Li-ion battery market, like transportation, due the system being stationary and proximal to the residential or commercial building it's benefitting. BTMS applications prioritize safety, cost (low/no-critical materials), reliability (20-year calendar life), and durability (10,000 cycle life), while having the ability to (minimally) compromise energy density and rate capability. Lithium titanate (Li4Ti5O12-, LTO) is a promising anode candidate for BTMS applications due to its high safety and capacity retention, while maintaining a reasonable 160 mAhg-1 reversable capacity and composition of relatively abundant materials. (1) Specifically, LTO has a high working voltage which helps to prevent Li dendrite formation, improving safety. Furthermore, LTO also has negligible lithiation-based volume change, leading to less mechanical pulverization, or loss of active material, upon cycling. For the cathode, materials with little or no Co are of high interest due to the high cost and low abundance of Co. LiMn2O4 (LMO) has been paired with LTO for BTMS applications in the past due to its safety, low cost (abundancy), and reasonably high operating voltage. (2-4) However, the low capacity of LMO limits energy density and specific energy. While not the highest priority for BTMS applications, increasing energy density will enable deployment in space constrained BTMS applications and decrease total cost. LiNi0.9Mn0.1O2 (LN-MO) is a recently developed material with promise due to its high operating voltage and relatively low price. (5) However, Ni-rich layered oxides, including LNMO, tend to struggle with capacity retention during high-voltage cycling due to mechanical pulverization, irreversible phase transitions, and unstable solid-electrolyte interphase. The study presented here focuses on building an understanding of how electrolyte solvent and varied cutoff potentials will impact the cycle life of LTO/LN-MO cells. Specifically, a comparison is provided between ethylene carbonate (EC), ethyl methyl carbonate (EMC), fluoroethylene carbonate (FEC), and Gen2 electrolyte solvents with 1M Lithium hexafluorophosphate (LiPF6) salt, cycling to two upper termination potentials, 2.6V and 2.7V. Electrochemical testing and diagnostics (e.g., differential capacity analysis, area specific impedance, constant voltage hold, and rate capability) and post-mortem characterization will be used to understand the aging behavior and failure mechanisms of the 8 cell combinations (four electrolytes and two voltage cutoffs). Cells with FEC electrolyte showed a lower initial capacity compared to cells with Gen2, EMC, and EC cycling at both voltages; however, the cells with FEC showed consistent trends in capacity retention with 2.6V and 2.7V termination potentials, while the cells with the other electrolytes showed much higher rates of capacity loss when cycling to the higher voltage. These results indicate that FEC may play a role in improving durability of high-voltage, Ni-rich electrode systems for use in high-cycle applications, such as BTMS.

electrolyte↗

Considerations regarding the Use of Computer Vision Machine Learning in Safety-Related or Risk-Significant Applications in Nuclear Power Plants

With the advancements made to date in the field of artificial intelligence (AI), significant potential exists to utilize AI capabilities for nuclear power plant (NPP) applications. AI can replicate human decision making and it is usually faster and more accurate than humans. For implementations that impact critical NPP applications (e.g., safety-related or non-safety systems that potentially affect overall plant risk), a deeper safety analysis of the AI methods is necessary. AI applied to NPP operations could resemble the use of digital I&C (DI&C) because such applications involve digital computer hardware and custom-designed software that input plant data, execute complex software algorithms, and output the results to a system or licensed human operator to potentially provoke an action. For AI methods to be compliant with current safety requirements for DI&C, AI compatibility must be evaluated, and AI-related gaps may exist that prevent the prompt deployment of AI in NPPs. This effort aims to evaluate how example AI technologies align with the DI&C safety framework, and discusses how they could be analyzed, modeled, tested, and validated in a manner similar to typical DI&C technologies. Because AI is a broad field that encompasses areas such as machine learning (ML), natural language processing, and computer vision, this research focused on a subset of methods categorized as the computer vision ML (CVML) methods. This report explores two CVML use cases, gauge reading and fire watch, considered relevant to the DI&C standards, as they could play a safety-critical role. For the gauge reading use case, a CVML-enabled technology that can read gauges at oblique angles is utilized. For the fire watch use case, a CVML-enabled technology is utilized that migrates fire watch from a manual (human) approach to automated fire detection. These use cases are mainly intended to give context to the CVML system discussion. This effort assumes the worst-case scenario, with the CVML system being used to replace a safety-related or risk-significant system, thus requiring evaluation. Evaluating CVML against most of the relevant safety requirements for DI&C yielded several CVML-specific considerations due to the uniqueness of its characteristics in comparison with typical DI&C systems. For example, CVML models often employ commonly used (open-source) datasets, and it is not always possible to determine the level of overlap among open-source datasets. Therefore, the independence of the developed CVML models when demonstrating diversity is questionable, therefore creating vulnerability to common cause failure (CCF). The design verification process is also impacted since the data overlap could result in overestimation of the software validation and verification (V&V) performance results. Section 2 of this report evaluates a list of the identified CVML-specific characteristics and discusses the resulting considerations and potential solutions in the context of each referenced requirement. A summation is provided in Section 3. This report is not to be used as a guideline. It was developed to identify and consider issues in the implementation of ML technologies used to augment activities that may have a bearing on plant operation. The report draws parallels to the use of DI&C technologies, for which many standards are available to guide their use in nuclear plant operation. It considers the technologies and some of the potential implications of their use in safety-related applications but is not intended to address regulatory or licensing related issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanical Properties of Permanent Foaming Fixatives for Deactivation and Decommissioning Activities

DOE-EM have identified an operational requirement for a fixative that can immobilize and/or encapsulate residual contamination in 3D void volumes (pipes, gloveboxes, waste containers, etc.) during D and D activities. Failure to safely and effectively immobilize residual contamination can: Put workers at risk, Contaminate the public and environment, Drive up operational costs. Commercial-off-the-shelf (COTS) polyurethane (PU) foams is one possible solution and is currently being investigated in collaboration with Savannah River National Lab (SRNL). Mechanical property testing will dictate how well PU foams can withstand physical stressors outlined in safety documents while immobilizing residual contamination. Results can provide a performance criteria for Section 5 of ASTM E3191: Standard Specification for Permanent Foaming Fixatives Used to Mitigate Spread of Radioactive Contamination. Polyurethanes consists of repeating units of urethanes which are produced from an exothermic reaction between a polyol (an alcohol with two or more hydroxyl groups in a molecule) and an isocyanate [2]. PUs consists of 3D cells that are formed by a blowing agent which is normally water. Water interacting with the isocyanate creates carbon dioxide and urea which contributes to cells' growth and expansion. The cross-linking between the polyol and isocyanate solidify the cell faces and walls. Micro scale properties that can influence mechanical properties include: Relative density (ratio between density of cellular material and density of the solid of which the cell walls are made of). Cells connectivity between edges and faces, and number of cells contact neighbors [3]. Whether a foam is open-celled or closed-celled. Closed-celled foams have a thin membrane that encloses each cell which can contribute to the stiffness of the foam. Incorporating fillers in the PU matrix like carbon-based nanoparticles in the form of expandable graphite (EG) can increase the thermal and mechanical performance [4]. When exposed to heat, EG produces a char layer that prevents heat and oxygen transfer which is known as intumescing. Mechanical performance is dependent on amount of EG loading since the cell sizes are linearly dependent on it. Overall, the rigid foams (I-R2) proved superior. SEM Analysis: I-R2 had the most consistent spherical sizes (average cell diameter: 489 μm), which enhance the relative density the most [5]. Tensile Testing Results: I-R2 experienced the largest breaking load (103.65 lbf) and stress (289.42 psi). I-R2 also had a higher Young's Modulus compared to R1 (2.99 ksi to 2.09 ksi). Compression Testing Results: I-R2 had the highest stress at 80% deflection (360.67 psi), load (1387.48 lbf) and modulus (3.92 ksi)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Refinement of Salt Dissolution Inhibitor Requirements (Final Report)

At Savannah River Site (SRS), High-Level Waste is stored in below-grade carbon steel tanks. This waste in part consists of sludge, salt cake, and/or supernate. Preparation of this waste for future processing involves dissolution of the salt cake layer. The salt dissolution process can create conditions that leave the carbon steel tanks susceptible to localized corrosion. The salt to be dissolved contains high concentrations of nitrate, that once released, create an environment that may be conducive to pitting corrosion and/or stress corrosion cracking (SCC) of carbon steel. The salt dissolution process also liberates interstitial liquid trapped between the salt crystals. This liquid is initially high in nitrite and hydroxide concentration. High pH and greater ratios of nitrite to nitrate act as inhibitors to minimize corrosion of carbon steel in high nitrate environments. However, as dissolution proceeds, the concentration of nitrate will increase, while the hydroxide and nitrite concentration of the interstitial liquid will deplete and become insufficient to prevent the onset of corrosion attack. Tank blending and addition of inhibitors are used to ensure adequate concentrations of hydroxide and nitrite. However, this is not desirable during salt dissolution as it can reduce process efficiency and increase the amount of waste that needs processing. It has been proposed that these corrosion control limits be revisited to evaluate the corrosion susceptibility of carbon steel in environments that more closely resemble current operating conditions at SRS. An experimental matrix was designed to evaluate the use of the pitting factor for supernate chemistries characteristic to SRS, particularly during the salt dissolution process. Two electrochemical methods were identified to determine the susceptibility of A537 and A285 low-carbon steels to pitting corrosion with this chemistry envelope at temperatures up to 75 °C. The predominant electrochemical test method was Cyclic Potentiodynamic Polarization (CPP) studies. Through CPP, the pitting factor was used, based on Hanford Site corrosion studies, to accurately identify pitting susceptibility within the compositional range studied with some conservatism. Additionally, sulfate was determined to have no statistically significant influence, at concentrations up to 0.6 M, on pitting behavior in more concentrated solutions where other aggressive species govern pitting susceptibility. Where CPP was inconclusive, Modified ASTM G192 was successfully used to evaluate pitting susceptibility conditions and allowed for a pass/fail result to be determined. In all cases, the pitting factor was determined to be applicable to the simulants tested, with this metric accurately predicting incidences in which pitting occurred. Based upon the findings in this work, a pitting factor of 1.2 is being proposed to build in a safety factor and remain consistent with the Hanford Site approach. Additionally, a minimum pH limit of 12 is proposed to ensure carbon steel passivity and localized corrosion the primary degradation mechanism. Susceptibility to SCC was evaluated using a reduced matrix of tests at 75 °C. No failures due SCC were observed at open circuit. In addition, tests polarized anodically by 200 mV only resulted in failures for trials with pitting factors less than 0.86. However, a test with a passing condition based upon the pitting factor metric (pitting factor = 1.40) did exhibit a failure with an applied potential of +300 mV vs. OCP. This result is contrary to the prediction based upon the pitting factor, however, a polarization of 300 mV, or even 200 mV, from open circuit is substantial. The relationship between these testing parameters and service environment/conditions and the desired level of conservatism in the metric should be further evaluated in the determination of the significance of this result. While the pitting factor accurately predicted susceptibility to SCC at temperatures up to 75 °C and with positive overpotentials up to 200 mV, the relatively small sample matrix and failure of a passing pitting factor with a 300 mV polarization resulted in an inconclusive determination of whether the pitting factor may be used for predicting susceptibility to SCC at temperatures between 50 °C and 75 °C. As such, additional testing is recommended to evaluate the validity of the pitting factor for SCC susceptibility prediction at temperatures between 50 °C and 75 °C.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗