Search NASA⌕ Search

SEARCH · Search NASA

Results for “failure temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A combined experimental and finite element study to predict the failure mechanisms in SiC coated carbon/carbon composites at room and elevated temperatures under flexural loading

Response of quasi-isotropic laminates of SiC coated Carbon/Carbon (C/C) composites have been investigated under flexural loading at various temperatures. Variation of load-deflection behavior with temperatures are studied. Increase in flexural strength and stiffness are observed with the rise in temperature. Extensive analyses through Optical Microscope (OM) and Non-Destructive Evaluation (NDE) have been performed to understand the failure mechanisms. Damage zone is found only within the neighborhood of the loading plane. Isoparametric layered shell elements developed on the basis of the first order shear deformation theory have been used to model the thin laminates of C/C under flexural loading. Large deformation behavior has been considered in the finite element analysis to account for the non-linearities encountered during the actual test. Data generated using finite element analysis are presented to corroborate the experimental findings, and a comparison in respect of displacement and stress-strain behavior are given to check the accuracy of the finite element analysis. Reasonable correlation between the experimental and finite element results have been established.

Mahfuz, Hassan↗

Accelerated life testing effects on CMOS microcircuit characteristics, phase 1

An accelerated life test of sufficient duration to generate a minimum of 50% cumulative failures in lots of CMOS devices was conducted to provide a basis for determining the consistency of activation energy at 250 C. An investigation was made to determine whether any thresholds were exceeded during the high temperature testing, which could trigger failure mechanisms unique to that temperature. The usefulness of the 250 C temperature test as a predictor of long term reliability was evaluated.

Maximow, B.↗

Investigation of mounting discrete chip components for hybrid microelectronic applications.

In the assembly of hybrid microcircuits, passive and active discrete chip components are attached by epoxy cements and by solders. This study was initiated to determine the integrity of such attachments. Alumina substrates were subjected to a group of thermal and mechanical test environments defined by test methods in MIL-STD-883. Lot samples of substrates with assembly variations were subjected to separately applied testing and to serial testing. These test methods were applied sequentially to the same lot of substrates. Epoxy cements were generally satisfactory with respect to separate tests, although sequential tests severely degraded epoxy bond strengths of all types. Bond strengths to unglazed substrates were slightly superior to those of the same components on glazed types. Solder joints were vulnerable to catastrophic failure in several environments, especially temperature cycling and thermal shock. Vibration and impact shock also produced solder joint failures.

Caruso, S. V.↗

Probabilistic structural analysis of space propulsion system LOX post

The probabilistic structural analysis program NESSUS (Numerical Evaluation of Stochastic Structures Under Stress; Cruse et al., 1988) is applied to characterize the dynamic loading and response of the Space Shuttle main engine (SSME) LOX post. The design and operation of the SSME are reviewed; the LOX post structure is described; and particular attention is given to the generation of composite load spectra, the finite-element model of the LOX post, and the steps in the NESSUS structural analysis. The results are presented in extensive tables and graphs, and it is shown that NESSUS correctly predicts the structural effects of changes in the temperature loading. The probabilistic approach also facilitates (1) damage assessments for a given failure model (based on gas temperature, heat-shield gap, and material properties) and (2) correlation of the gas temperature with operational parameters such as engine thrust.

Newell, J. F.↗

Moisture-Induced TBC Spallation on Turbine Blade Samples

Delayed failure of TBCs is a widely observed laboratory phenomenon, although many of the early observations went unreported. "The weekend effect" or "DeskTop Spallation" (DTS) is characterized by initial survival of a TBC after accelerated laboratory thermal cycling, then failure by exposure to ambient humidity or water. Once initiated, failure can occur quite dramatically in less than a second. To this end, the water drop test and digital video recordings have become useful techniques in studies at NASA (Smialek, Zhu, Cuy), DECHMA (Rudolphi, Renusch, Schuetze), and CNRS Toulouse/SNECMA (Deneux, Cadoret, Hervier, Monceau). In the present study the results for a commercial turbine blade, with a standard EB-PVD 7YSZ TBC top coat and Pt-aluminide diffusion bond monitored by weight change and visual appearance. Failures were distributed widely over a 5-100 hr time range, depending on temperature. At some opportune times, failure was captured by video recording, documenting the appearance and speed of the moisture-induced spallation process. Failure interfaces exhibited alumina scale grains, decorated with Ta-rich oxide particles, and alumina inclusions as islands and streamers. The phenomenon is thus rooted in moisture-induced delayed spallation (MIDS) of the alumina scale formed on the bond coat. In that regard, many studies show the susceptibility of alumina scales to moisture, as long as high strain energy and a partially exposed interface exist. The latter conditions result from severe cyclic oxidation conditions, which produce a highly stressed and partially damaged scale. In one model, it has been proposed that moisture reacts with aluminum in the bond coat to release hydrogen atoms that 'embrittle' the interface. A negative synergistic effect with interfacial sulfur is also invoked.

Smialek, James L.↗

Moisture-Induced TBC Spallation on Turbine Blade Samples

Delayed failure of TBCs is a widely observed laboratory phenomenon, although many of the early observations went unreported. The weekend effect or DeskTop Spallation (DTS) is characterized by initial survival of a TBC after accelerated laboratory thermal cycling, then failure by exposure to ambient humidity or water. Once initiated, failure can occur quite dramatically in less than a second. To this end, the water drop test and digital video recordings have become useful techniques in studies at NASA (Smialek, Zhu, Cuy), DECHMA (Rudolphi, Renusch, Schuetze), and CNRS Toulouse/SNECMA (Deneux, Cadoret, Hervier, Monceau). In the present study the results for a commercial turbine blade, with a standard EB-PVD 7YSZ TBC top coat and Pt-aluminide diffusion bond coat are reported. Cut sections were intermittently oxidized at 1100, 1150, and 1200 C and monitored by weight change and visual appearance. Failures were distributed widely over a 5-100 hr time range, depending on temperature. At some opportune times, failure was captured by video recording, documenting the appearance and speed of the moisture-induced spallation process. Failure interfaces exhibited alumina scale grains, decorated with Ta-rich oxide particles, and alumina inclusions as islands and streamers. The phenomenon is thus rooted in moisture-induced delayed spallation (MIDS) of the alumina scale formed on the bond coat. In that regard, many studies show the susceptibility of alumina scales to moisture, as long as high strain energy and a partially exposed interface exist. The latter conditions result from severe cyclic oxidation conditions, which produce a highly stressed and partially damaged scale. In one model, it has been proposed that moisture reacts with aluminum in the bond coat to release hydrogen atoms that embrittle the interface. A negative synergistic effect with interfacial sulfur is also invoked.

Smialek, James↗

Effects of Heat Pipe Failures in Microreactors

Microreactors provide new opportunities for nuclear reactor applications given their long-lived fuel source, compact size, portability, reliability as it relates to safety and their self-regulating nature. To take advantage of these opportunities there are technological challenges that need to be overcome. One advancing technology often used in conjunction with microreactor designs are heat pipes, which are used for heat removal from the reactor core to the power conversion system. Heat pipes are a substitute for the traditional system in which the same fluid used as coolant in the reactor is then used as the working fluid in the power conversion system. This document describes how heat pipes operate, what happens when a heat pipe fails, and what codes can be used to simulate the results. Our analyses show that a single/double heat pipe failure results in a temperature increase of 15-50°C respectively in surrounding heat pipes. Heat pipe microreactors could be easily designed such that this increase is within the maximum parameters allowable for safety and does not result in cascading heat pipe failure. Thus, such failures do not lead to severe degradation of the reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Microelectromechanical System (MEMS) Device Being Developed for Active Cooling and Temperature Control

High-capacity cooling options remain limited for many small-scale applications such as microelectronic components, miniature sensors, and microsystems. A microelectromechanical system (MEMS) using a Stirling thermodynamic cycle to provide cooling or heating directly to a thermally loaded surface is being developed at the NASA Glenn Research Center to meet this need. The device can be used strictly in the cooling mode or can be switched between cooling and heating modes in milliseconds for precise temperature control. Fabrication and assembly employ techniques routinely used in the semiconductor processing industry. Benefits of the MEMS cooler include scalability to fractions of a millimeter, modularity for increased capacity and staging to low temperatures, simple interfaces, limited failure modes, and minimal induced vibration. The MEMS cooler has potential applications across a broad range of industries such as the biomedical, computer, automotive, and aerospace industries. The basic capabilities it provides can be categorized into four key areas: 1) Extended environmental temperature range in harsh environments; 2) Lower operating temperatures for electronics and other components; 3) Precision spatial and temporal thermal control for temperature-sensitive devices; and 4) The enabling of microsystem devices that require active cooling and/or temperature control. The rapidly expanding capabilities of semiconductor processing in general, and microsystems packaging in particular, present a new opportunity to extend Stirling-cycle cooling to the MEMS domain. The comparatively high capacity and efficiency possible with a MEMS Stirling cooler provides a level of active cooling that is impossible at the microscale with current state-of-the-art techniques. The MEMS cooler technology builds on decades of research at Glenn on Stirling-cycle machines, and capitalizes on Glenn s emerging microsystems capabilities.

Beach, Duane E.↗

High Temperature Optocoupler for 3D High Density Power Modules

The goal of this proposed research is to develop a reliable high-temperature optocouplers, which can operate at 250°C with at least ten-year lifetime, and replace isolation transforms as the galvanic isolation solution for the 3D integration of high density power modules. The electrification of future transportations (i.e., electric vehicles) will continuously drive the demand for high density power modules. Optocouplers (i.e., packaged light emitter and detector) as a promising candidate to replace bulky isolation transformers are highly desirable to facilitate the continuous scale-down of gate driver circuitry that will lead to 3D high density power modules and achieve disruptive performance in terms of thermal management, power density, power efficiency, reliability and operating environments. However, regular semiconductor optoelectronic materials and devices have significant difficulty functioning in the harsh environments designated for high density power module usage (such as operation at high temperatures). Ultimately, it is not the intrinsic properties of power devices that prevent their use at higher temperatures, but rather the low voltage electronics needed to drive them and the packaging that surrounds them. The typical operating temperature for optocouplers is only up to 100°C, due to the limitations of light emitting diode (LED) devices inside and packaging materials. A systematic characterization methodology will be developed to analyze the performance, lifetime and reliability of LED devices and distinguish multiple failure mechanisms at high temperatures. An original methodology of “design for reliability” will be developed to design the optoelectronic devices with high reliability and long lifetime at high temperatures. A new architecture of high temperature high reliable optocouplers will be developed, fabricated and demonstrated with continuous operating at 250°C. The development of efficient, reliable high density 3D power modules is the foundation for energy efficiency and energy reliability. Enabled with advanced 3D integration and packaging technologies, high density power module solutions can achieve much more superior performance over the conventional discrete solutions in terms of efficiency, thermal management and power density. The proposed concept of high temperature optocouplers as the galvanic isolation solution for high density power modules will bring together interdisciplinary research involving the wide bandgap materials, optoelectronics, high reliable device design, electronics packaging and power modules. A streamline of skilled personnel would be trained including graduate and undergraduate students, local engineers and scientists which are in great demand to both academia and optoelectronics industry. The proposed research topics, such as, solid state lighting and high temperature device reliability, are currently of major interest at the Department of Energy, in particular, Sandia National Laboratories. This project can enhance collaborations between the University of Arkansas (UA) and Sandia National Laboratories. The findings of the proposed research are expected to be integrated into high density 3-D power modules at the Engineering Research Center for Power Optimization for Electro-Thermal Systems (POETS).

42 ENGINEERING↗

Design/Analysis of the JWST ISIM Bonded Joints for Survivability at Cryogenic Temperatures

A major design and analysis challenge for the JWST ISIM structure is thermal survivability of metal/composite bonded joints below the cryogenic temperature of 30K (-405 F). Current bonded joint concepts include internal invar plug fittings, external saddle titanium/invar fittings and composite gusset/clip joints all bonded to M55J/954-6 and T300/954-6 hybrid composite tubes (75mm square). Analytical experience and design work done on metal/composite bonded joints at temperatures below that of liquid nitrogen are limited and important analysis tools, material properties, and failure criteria for composites at cryogenic temperatures are sparse in the literature. Increasing this challenge is the difficulty in testing for these required tools and properties at cryogenic temperatures. To gain confidence in analyzing and designing the ISIM joints, a comprehensive joint development test program has been planned and is currently running. The test program is designed to produce required analytical tools and develop a composite failure criterion for bonded joint strengths at cryogenic temperatures. Finite element analysis is used to design simple test coupons that simulate anticipated stress states in the flight joints; subsequently the test results are used to correlate the analysis technique for the final design of the bonded joints. In this work, we present an overview of the analysis and test methodology, current results, and working joint designs based on developed techniques and properties.

Bartoszyk, Andrew↗

Candidate materials for advanced fire-resistant photovoltaic modules

A cooperative, cost-sharing research effort to develop a technology base required to construct fire-ratable photovoltaic modules has resulted in the identification of several high-temperature, back-surface candidate materials capable of raising the fire-resistance of modules using hydrocarbon encapsulants to Class A and B levels. Advanced experimental module configurations have been developed using back surfaces consisting of Kapton, Tedlar laminates, metal-foils, and fiberglass materials with high-temperature coatings. Test results (October 1984; March 1985; May 1985; and October 1985) indicate that several of these advanced module configurations are capable of achieving Class B fire-resistance levels, while a few configurations can achieve Class A levels. The paper summarizes activities to date, discussing flammability failure mechanisms, time-temperature profiles, and results of Block V environmental exposure tests of a candidate material suitable for both Class B and Class A fire-resistance levels.

Sugimura, R. S.↗

Field‐Relevant Degradation Mechanisms in Metal Halide Perovskite Modules

Field testing, failure analysis, and understanding of degradation mechanisms are essential to advancing metal halide perovskite (MHP) photovoltaic (PV) technology toward commercialization. Here, we present performance data from up to 1 year of outdoor testing of MHP modules in Golden, Colorado. The module encapsulation architecture and encapsulant materials have a significant impact on module reliability, with modules containing a polyolefin elastomer (POE) in addition to a desiccated polyisobutylene (PIB) edge seal outlasting modules with only a PIB edge seal or PIB blanket. Nondestructive and destructive characterization of the field-tested modules points to module scribes and interfaces as areas of potential mechanical weakness and chemical migration, resulting in shunt pathways and increased series resistance. Finally, indoor accelerated stress testing with light and elevated temperatures is performed, demonstrating failure with similar scribe degradation signatures as compared to the field-tested modules. In conclusion, under both outdoor testing and light and elevated temperature conditions, electrochemical corrosion between the copper electrode and the mobile iodine ions appeared dominant, with a significant progression at the scribes that is speculated to result from an interplay between the initial laser damage and joule heating from enhanced ion diffusion under bias.

14 SOLAR ENERGY↗

An investigation of adhesive/adherend and fiber/matrix interactions. Part B: SEM/ESCA analysis of fracture surfaces

Adhesion was studied with emphasis on the characterization of surface oxide layers, the analysis of fracture surfaces, and the interaction of matrices and fibers. A number of surface features of the fractured lap shear samples were noted in the SEM photomicrographs including the beta phase alloy of the Ti 6-4 adherend, the imprint of the adherend on the adhesive failure surface, increased void density for high temperature samples, and the alumina filler particles. Interfacial failure of some of the fractured lap shear samples is invariably characterized by the appearance of an ESCA oxygen photopeak at 530.3 eV assigned to the surface oxide layer of Ti 6-4 adherend. The effect of grit blasting on carbon fiber composites is evident in the SEM analysis. A high surface fluorine concentration on the composite surface is reduced some ten fold by grit blasting.

Beck, B.↗

LANL Phase 3 Container Loading in Support of the Fire-Induced Pressure Response and Failure Characterization of PCV/SCV/3013 Containers

The PCV/SCV/3013 Thermal Test Program is intended to determine the pressure response of packaged 3013 containers when exposed to a facility fire in the K-Area Complex (KAC) at the Savannah River Site. The fire tests support the KAC safety basis and must be bounding of the maximum pressure that would result from any 3013 container exposed to a KAC facility fire. The testing program has the following objectives: “To increase understanding of the pressure and temperature conditions at which failure occurs; To determine the allowable moisture for which failure will not occur under specified fire conditions, and; To increase understanding regarding the effects of salts on the pressurization, corrosion, and potential failure of the container.”

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Swift BAT Loop Heat Pipe #0 Temperature Droop Problem and Solution After Its Primary Heater Controller Failure

The primary heater controller for Burst Alert Telescope (BAT) loop heat pipe (LHP) #0 failed on March 31, 2010. It has been disabled. The secondary heater circuit is operational. However the set point tolerance of the secondary heater controller is significantly out of specifications. A novel variable conductance heat pipe (VCHP) is used to pre-condition the LHP propylene liquid before it returns to the compensation chamber (CC). Due to the limit on the quantity of power switches, the LHP and VCHP temperatures are controlled by different channels of the same heater controller. For this reason, the VCHP heater controller channel is also out of specification. It caused larger tolerances in the temperature of the propylene liquid returning to the CC. As a result, there were intermittent temperature droops every 10-14 days at the coldest attitude during the eclipse. After the set point of the secondary heater controller was gradually increased from 8 C to 8.7 C, there was no temperature droop for over four months.

Choi, Michael K.↗

HDG-1 Experiment Irradiation Monitoring Data Qualification Final Report

SUMMARY The U.S. Department of Energy (DOE) Advanced Reactor Technologies (ART) Graphite Research and Development (GRD) Program is conducting a series of six experiments to quantify the effects of irradiation on nuclear-grade graphite. This report documents the qualification of irradiation monitoring data for the fifth experiment, High Dose Graphite-1 (HDG-1). Qualified monitoring data are required by the ART program to support the design and licensing of the first high-temperature reactor (HTR) nuclear plant. Data are classified as Qualified if they meet the usage requirements described in the experiment planning and quality assurance (QA) documents, Failed if they do not meet those requirements and provide no usable information, or Trend if they do not fully meet all requirements but still provide useful information subject to an assessment of how any deficiencies may affect a particular use of the data. HDG-1 irradiation began with Advanced Test Reactor (ATR) Cycle 168B on August 24, 2020, and concluded after Cycle 173C on January 27, 2025. The HDG-1 capsule was removed from the reactor core twice—during core internal change (CIC) Cycle 170A and powered axial locator mechanism (PALM) Cycle 172A—to prevent overheating of the graphite specimens during high-power PALM cycles. The capsule was therefore irradiated during a total of seven normal ATR cycles: 168B, 169A, 171A, 171B, 173A, 173B, and 173C. Irradiation monitoring data evaluated in this report include thermocouple (TC) temperature, gas flow rate, gas moisture, gas pressure, specimen load, and graphite stack displacement. Temperature. A total of 14,508,065 TC temperature records were captured. Of these, 13,901,785 (95.8%) are Qualified and 606,280 (4.2%) are Failed. The principal source of failed temperature data was the instrument failure of TC-9 (Zone 2) on June 24, 2024, and TC-10 (Zone 1) on July 5, 2024, near the end of Cycle 173A, which resulted in 595,554 Failed readings. An additional 379 missing values and 10,347 slightly negative values from TC-13 during ATR outages are also Failed. Neither TC-9 nor TC-10 was used as a temperature-control TC, and their failures did not compromise capsule condition monitoring. Correlation analysis of all 13 TCs found no evidence of virtual junction formation. Control chart analysis revealed clear downward drift of approximately 80°C for TC-6 (Zone 3) relative to other stable TCs, and possible downward drift of approximately 60°C for TC-13 relative to the Zone 5 control TC (TC-1), though TC-13 remained consistent with the Zone 2 control TC (TC-12). Gas flow. A total of 20,088,090 gas flow rate records were captured. Of these, 19,941,463 (99.3%) are Qualified and 146,627 (0.7%) are Failed due to missing values. All argon, helium, and total gas flow data were within expected ranges throughout the irradiation. Gas moisture. A total of 1,116,005 outlet gas moisture values were captured. Of these, 1,101,421 (98.7%) are Qualified and 14,584 (1.3%) are Failed, comprising 14,556 out-of-range values and 28 missing values. The out-of-range moisture values exceeded 22,000 ppmv for approximately 1 week at the beginning of Cycle 173A, when accumulated moisture evaporated after the capsule was retrieved from water storage during PALM Cycle 172A and reinserted into the east flux trap. Moisture levels returned to below 25 ppmv for the remaining three cycles, and the transient high-moisture event did not affect the integrity of specimen irradiation. Gas pressure. A total of 7,812,035 gas pressure values were captured. Of these, 6,642,048 (85.0%) are Qualified and 1,169,987 (15.0%) outlet pressure values are Failed, comprising 718,537 zero outlet pressure values due to sensor failure from Cycle 168B through Cycle 171B, 54,550 missing values, and 396,900 too-low outlet pressure values, ranging from 1.1 to 1.6 psia after sensor replacement during Cycle 173A. Load. A total of 6,696,030 load values were captured. Of these, 6,694,580 (99.98%) are Qualified and 1,450 (0.02%) are Failed due to missing values. Applied loads to the six specimen stacks were stable throughout the irradiation. Stack displacement. A total of 6,696,030 displacement values were captured. Of these, 5,713,297 (85.32%) are Qualified and 3,781 (0.06%) are Failed due to missing values. Stack displacement increased consistently throughout the irradiation, reaching approximately 3.08 in. for Channels 5 and 6 by the end of irradiation. 978,952 (14.62%) substantially elevated displacements observed for Channel 6 beginning in Cycle 171A and for Channel 5 beginning in Cycle 173A are assigned Trend status. Raising pressure. A total of 1,115,999 raising pressure values were captured. Of these, 1,115,430 (99.95%) are Qualified and 569 (0.05%) are Failed due to missing values. Ram pressure. A total of 6,696,030 ram pressure values were captured. Of these, 6,692,249 (99.95%) are Qualified and 3,484 (0.05%) are Failed due to missing values. Stack raising was perf

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal-hydraulics capabilities in predicting the post-CHF conditions

Developing research in a time-at-temperature limit for fuel failure requires assessing both the material modeling and the thermal-hydraulic modeling capabilities. Predictions of post-CHF conditions have areas for development leveraging experiments, code coupling, and general model improvement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗