Pressure-Sensitive Paint Measurements on the NASA Common Research Model in the NASA 11-ft Transonic Wind Tunnel

The luminescence lifetime technique was used to make pressure-sensitive paint (PSP) measurements on a 2.7% Common Research Model in the NASA Ames 11ft Transonic Wind Tunnel. PSP data were obtained on the upper and lower surfaces of the wing and horizontal tail, as well as one side of the fuselage. Data were taken for several model attitudes of interest at Mach numbers between 0.70 and 0.87. Image data were mapped onto a three-dimensional surface grid suitable both for comparison with CFD and for integration of pressures to determine loads. Luminescence lifetime measurements were made using strobed LED (light-emitting diode) lamps to illuminate the PSP and fast-framing interline transfer cameras to acquire the PSP emission.

Bell, James H.↗

Algorithm for Rapid Searching Among Star-Catalog Entries

An algorithm searches a star catalog to identify guide stars within the field of view of a telescope or camera. The algorithm is fast: the number of computations needed to perform the search is approximately proportional to the logarithm of the number of stars in the catalog. The algorithm requires the prior organization of the star catalog into a hierarchy utilizing independent spherical coverings (see figure), such that each successively higher level contains fewer elements. In the lowest and most numerous level of the hierarchy, the elements are individual stars in the star catalog. The next higher level contains a spherical covering (a constellation of n points on a sphere that minimizes the maximum distance of any point on the sphere from the closest one of the n points), the next higher level contains a smaller spherical covering, and so forth, ending at the highest level, which contains one element representing the point of entry into the search structure. With necessary exceptions at the lowest and highest levels, each element at each level is labeled in terms of the element to which it is linked in the next higher level and the first element to which it is linked in the next lower level. Each element is also labeled in terms of (1) its coordinates on the celestial sphere and (2) the largest angular distance to any element in any lower level in the hierarchy. The elements at all levels of the hierarchy are numbered on a single list, such that the elements of each constellation at each level are numbered consecutively. The algorithm is recursive. The input required to start the algorithm comprises the coordinates of a point on the celestial sphere. Attention is then focused on individual elements of the hierarchy, starting from the topmost one, as follows: The angle between the input point and the element under consideration is calculated. If the calculated angle is larger than the sum of (1) the predetermined angle to the most distant element plus (2) the half field of view of the telescope, then no stars will be within the field of view and this recursive part of the algorithm is terminated.

Liebe, Carl Christian↗

Bremsstrahlung emission modelling and application to fast electron physics

Measurements of fast electron bremsstrahlung (FEB) using hard X-ray (HXR) cameras provide a unique diagnostic for the fast electron dynamics, with resolution in space, time and energy. A synthetic HXR diagnostic is developed to calculate the distribution function and FEB emission, such that experimental results can be directly compared with simulations. Using this comparison, the role of fast electron radial transport in radio-frequency current drive is investigated. For two cases studied in this paper, the HXR emission is consistent with negligible radial transport, although in one case this is in disagreement with the measured driven current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Double Image Polarimeter—Ultra Fast: Simultaneous Three-color (BVR) Polarimeter with Electron-multiplying Charge-coupled Devices

We describe a new instrument capable of high-precision (10{sup −5}) polarimetric observations simultaneously in three passbands (BVR). The instrument utilizes electron-multiplying charge-coupled device (EM CCD) cameras for high efficiency and fast image readout. The key features of the Double Image Polarimeter—Ultra Fast (DIPol-UF) are: (i) the optical design with high throughput and inherent stability; (ii) great versatility, which makes the instrument optimally suitable for observations of bright and faint targets; and (iii) a control system, which allows the use of the polarimeter remotely. Examples are given of the first results obtained from high signal-to-noise observations of bright nearby stars and of fainter sources such as X-ray binaries in their quiescent states.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accurate and Fast Anomaly Detection in Additive Composite-Based Manufacturing using Thermal Cameras

Today, large-scale additive manufacturing with plastics and composite materials requires continuous monitoring by experienced staff to prevent, detect and correct anomalous events affecting the performance of the printed part. We address the complexity of this demanding task by designing a camera-based anomaly detection system utilizing probabilistic principal component analysis (PPCA). This is a machine learning technique is trained with thermal images collected during normal operation of the large-scale printer (Cincinnati BAAM). This technique is advantageous for practical applications as there is no need to artificially introduce anomalous conditions into model training. During deployment, we challenge this model by introducing deliberate variations of the extruder speed. We reduce extrusion speed to a lower level, between 70 and 95% of the nominal value to collected test images. Our results show that images are easily identified as anomalous for extruder speeds at or below 85% of the nominal speed, meaning that an anomalous reduction of the material deposition rate can be detected within seconds of its onset. We show that our results are robust to (a) camera-to-camera variability and (b) print-to-print variability.

Pike, John [ORNL]↗

Fast electron flux driven by lower hybrid wave in the scrape-off layer

The fast electron flux driven by Lower Hybrid Wave (LHW) in the scrape-off layer (SOL) in EAST is analyzed both theoretically and experimentally. The five bright belts flowing along the magnetic field lines in the SOL and hot spots at LHW guard limiters observed by charge coupled device and infrared cameras are attributed to the fast electron flux, which is directly measured by retarding field analyzers (RFA). The current carried by the fast electron flux, ranging from 400 to 6000 A/m{sup 2} and in the direction opposite to the plasma current, is scanned along the radial direction from the limiter surface to the position about 25 mm beyond the limiter. The measured fast electron flux is attributed to the high parallel wave refractive index n{sub ||} components of LHW. According to the antenna structure and the LHW power absorbed by plasma, a broad parallel electric field spectrum of incident wave from the antennas is estimated. The radial distribution of LHW-driven current density is analyzed in SOL based on Landau damping of the LHW. The analytical results support the RFA measurements, showing a certain level of consistency. In addition, the deposition profile of the LHW power density in SOL is also calculated utilizing this simple model. This study provides some fundamental insight into the heating and current drive effects induced by LHW in SOL, and should also help to interpret the observations and related numerical analyses of the behaviors of bright belts and hot spots induced by LHW.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D velocity map imaging of electrons with TPX3CAM

In this report we demonstrate three-dimensional velocity map imaging of low energy electrons using a TPX3CAM, where the three-dimensional momentum information [$p_x, p_y, p_z$] is encoded in position and timing [x, y, t] of hits on the camera sensor. We make use of the camera sensor for the [x, y] information and a constant fraction discriminator and fast time to digital converter in the camera for the time information. We illustrate the capabilities of our apparatus by presenting above threshold ionization measurements of xenon, which produces well defined structures in the momentum resolved photoelectron yield.

79 ASTRONOMY AND ASTROPHYSICS↗

Note: X-ray streak camera sweep speed calibration

X-ray streak cameras are extensively used to study transient x-ray processes in experiments carried out on various laser facilities at the Research Center of Laser Fusion. Precise calibration and clear description of the sweep speed of the x-ray streak camera are vital for obtaining precise temporal information to understand the fast physics phenomena. An x-ray streak camera named wide-slit x-ray streak camera has been calibrated using a small-scale laser facility with pulse duration of 8 ps. Sweep speeds on most part of the output screen (charge coupled device) are obtained. These calibration results can be used to correct the nonlinearity of sweep speed in measurement of temporal processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast-ion D{alpha} measurements of the fast-ion distribution (invited)

The fast-ion D{alpha} (FIDA) diagnostic is an application of charge-exchange recombination spectroscopy. Fast ions that neutralize in an injected neutral beam emit Balmer-{alpha} light with a large Doppler shift. The spectral shift is exploited to distinguish the FIDA emission from other bright sources of D{alpha} light. Background subtraction is the main technical challenge. A spectroscopic diagnostic typically achieves temporal, energy, and transverse spatial resolution of {approx}1 ms, {approx}10 keV, and {approx}2 cm, respectively. Installations that use narrow-band filters achieve high spatial and temporal resolution at the expense of spectral information. For high temporal resolution, the bandpass-filtered light goes directly to a photomultiplier, allowing detection of {approx}50 kHz oscillations in FIDA signal. For two-dimensional spatial profiles, the bandpass-filtered light goes to a charge-coupled device camera; detailed images of fast-ion redistribution at instabilities are obtained. Qualitative and quantitative models relate the measured FIDA signals to the fast-ion distribution function. The first quantitative comparisons between theory and experiment found excellent agreement in beam-heated magnetohydrodynamics (MHD)-quiescent plasmas. FIDA diagnostics are now in operation at magnetic-fusion facilities worldwide. They are used to study fast-ion acceleration by ion cyclotron heating, to detect fast-ion transport by MHD modes and microturbulence, and to study fast-ion driven instabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Far Ultraviolet Imaging from the Image Spacecraft: Wideband FUV Imaging - 2

The Far Ultraviolet Wideband Imaging Camera (WIC) complements the magnetospheric images taken by the IMAGE satellite instruments with simultaneous global maps of the terrestrial aurora. Thus, a primary requirement of WIC is to image the total intensity of the aurora in wavelength regions most representative of the aurora] source and least contaminated by dayglow, have sufficient field of view to cover the entire polar region from spacecraft apogee and have resolution that is Sufficient to resolve auroras on a scale of 1 to 2 latitude degrees, The instrument is sensitive in the spectral region from 140- 190 nm. The WIC is mounted on the rotating, IMAGE spacecraft viewing radially outward and has a field of view of 17 deg in the direction parallel to the spacecraft spin axis. Its field of view is 30 deg in the direction perpendicular to the spin axis, although only a 17 deg x 17 deg image of the Earth is recorded. The optics was an all-reflective, inverted Cassegrain Burch camera using concentric optics with a small convex primary and a large concave secondary mirror. The mirrors were coated by a special multi-layer coating, which has low reflectivity in the visible and near UV region, The detector consists of a MCP-Intensified CCD. The MCP is curved to accommodate the focal surface of the concentric optics. Tile phosphor of the image intensifier is deposited on a concave fiberoptic window, which is then Coupled to the CCD with a fiberoptic taper. The camera head operates in a fast frame transfer mode with the CCD being read approximately 30 full frames (512 by 256 pixel) per second with an exposure time of 0.033 s. The image motion (file to the satellite spin is minimal during such a short exposure. Each image is electronically distortion corrected using the look up table scheme. An offset is added to each memory address that is proportional to the image shift due to satellite rotation, and the charge signal is digitally summed in memory. On orbit, approximately 300 frames will be added to produce one WIC image in memory. The advantage of the electronic motion compensation and distortion correction is that it is extremely flexible, permitting several kinds of corrections including motions parallel and perpendicular to the predicted axis of rotation. File instrument was calibrated by applying ultraviolet light through a vacuum monochromator and measuring the absolute responsivity of the instrument. To obtain the data for the distortion look up table the camera was turned through various angles and the input angles corresponding to a pixel matrix were recorded. It was found that the spectral response peaked at 150 nm and fell off in either direction. The equivalent aperture of the camera, including mirror reflectivities and effective photocathode quantum efficiency, is about 0.04 sq cm. Thus, a 100 Rayleigh LBH aurora is expected to produce 23 equivalent counts per pixel per 10 s exposure at the peak of instrument response.

Mende, S. B.↗

Particle displacement tracking applied to air flows

Electronic Particle Image Velocimeter (PIV) techniques offer many advantages over conventional photographic PIV methods such as fast turn around times and simplified data reduction. A new all electronic PIV technique was developed which can measure high speed gas velocities. The Particle Displacement Tracking (PDT) technique employs a single cw laser, small seed particles (1 micron), and a single intensified, gated CCD array frame camera to provide a simple and fast method of obtaining two-dimensional velocity vector maps with unambiguous direction determination. Use of a single CCD camera eliminates registration difficulties encountered when multiple cameras are used to obtain velocity magnitude and direction information. An 80386 PC equipped with a large memory buffer frame-grabber board provides all of the data acquisition and data reduction operations. No array processors of other numerical processing hardware are required. Full video resolution (640x480 pixel) is maintained in the acquired images, providing high resolution video frames of the recorded particle images. The time between data acquisition to display of the velocity vector map is less than 40 sec. The new electronic PDT technique is demonstrated on an air nozzle flow with velocities less than 150 m/s.

Wernet, Mark P.↗

Particle displacement tracking applied to air flows

Electronic Particle Image Velocimetric (PIV) techniques offer many advantages over conventional photographic PIV methods such as fast turn around times and simplified data reduction. A new all electronic PIV technique was developed which can measure high speed gas velocities. The Particle Displacement Tracking (PDT) technique employs a single CW laser, small seed particles (1 micron), and a single intensified, gated CCD array frame camera to provide a simple and fast method of obtaining two-dimensional velocity vector maps with unambiguous direction determination. Use of a single CCD camera eliminates registration difficulties encountered when multiple cameras are used to obtain velocity magnitude and direction information. An 80386 PC equipped with a large memory buffer frame-grabber board provides all of the data acquisition and data reduction operations. No array processors of other numerical processing hardware are required. Full video resolution (640 x 480 pixel) is maintained in the acquired images, providing high resolution video frames of the recorded particle images. The time between data acquisition to display of the velocity vector map is less than 40 sec. The new electronic PDT technique is demonstrated on an air nozzle flow with velocities less than 150 m/s.

Wernet, Mark P.↗

Time-resolved x-ray and extreme ultraviolate spectrometer for use on the National Spherical Torus Experiment

We describe upgrades to a compact grazing-incidence spectrometer utilized on the National Spherical Torus Experiment for monitoring light and heavy impurities. A fast-readout charge couple device camera has been implemented that allows the recording of spectra with up to 25 ms time integration. This capability is used to study the time evolution of the K-shell emission of hydrogenlike and heliumlike boron, carbon, nitrogen, and oxygen between 10 and 65 A. Different camera positioning pieces have been employed to extend the possible spectral range to as high as 140. Several lines that cannot be ascribed to the usual elements found in the plasma have been observed in this spectral range, although often only in a few isolated discharges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Velocity map imaging in time of flight mass spectrometry

A new variation on time of flight mass spectrometry is presented, which uses a fast framing charge coupled device camera to velocity map image multiple product masses in a single acquisition. The technique is demonstrated on two photofragmentation processes, those of CS{sub 2} and CH{sub 3}S{sub 2}CH{sub 3} (dimethyldisulfide) at a photolysis wavelength of 193 nm. In both cases, several mass fragments are imaged simultaneously, and speed distributions and anisotropy parameters are extracted that are comparable to those obtained by imaging each fragment separately in conventional velocity map imaging studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The single-line-of-sight, time-resolved x-ray imager diagnostic on OMEGA

We present that the single-line-of-sight, time-resolved x-ray imager (SLOS-TRXI) on OMEGA is one of a new generation of fast-gated x-ray cameras comprising an electron pulse-dilation imager and a nanosecond-gated, burst-mode, hybrid complementary metal-oxide semiconductor sensor. SLOS-TRXI images the core of imploded cryogenic deuterium–tritium shells in inertial confinement fusion experiments in the ~4- to 9-keV photon energy range with a pinhole imager onto a photocathode. The diagnostic is mounted on a fixed port almost perpendicular to a 16 channel, framing-camera–based, time-resolved Kirkpatrick–Baez microscope, providing a second time-gated line of sight for hot-spot imaging on OMEGA. SLOS-TRXI achieves ~40-ps temporal resolution and better than 10 μm spatial resolution. Finally, shots with neutron yields of up to 1 × 10 14 were taken without observed neutron-induced background signal. The implosion images from SLOS-TRXI show the evolution of the stagnating core.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗