Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Probabilistic and Other Neural Nets in Multi-Hole Probe Calibration and Flow Angularity Pattern Recognition

The use of probabilistic (PNN) and multilayer feed forward (MLFNN) neural networks are investigated for calibration of multi-hole pressure probes and the prediction of associated flow angularity patterns in test flow fields. Both types of networks are studied in detail for their calibration and prediction characteristics. The current formalism can be applied to any multi-hole probe, however the test results for the most commonly used five-hole Cone and Prism probe types alone are reported in this article.

Baskaran, Subbiah↗

Hydraulic Response to Thermal Stimulation Efforts at Raft River Based on Stepped Rate Injection Testing

The injection well stimulation project at the Raft River geothermal field tests the effect of long-term cold water injection and high pressure injection on well injectivity, improvements to which could reduce operating costs. The primary data for analysis and interpretation of the injection test are step-rate flow tests run before each new phase of the injection. These tests were analyzed using a combination of standard pump-test analytical solution methods and methods developed expressly for the observed conditions. The stepped rate injection tests, combined with long-term flow and pressure response data suggest that the well is located within a fractured formation of low transmissivity but high storativity. These calculated parameters appeared to increase with pressure during the first injection test and the higher values were reproduced during the second stepped rate test. Calculated transmissivity and storativity are on the order of 4E-5 m cm 2 and 1E-4 m Pa -1 , respectively. The apparent pressure dependence of fitted hydraulic parameters may reflect near-well fracture compliance that increased the effective radius of the wellbore during the first test. While the type curve fit analysis also suggests that the reservoir behaves as a uniformly fractured reservoir with a radial flow regime, the hydraulic parameters indicate that condition may exist only a very limited distance (<10 m) from the well. Longer-term pressure response suggests that flow in the system effectively reaches steady state in a period of less than a day, which may reflect pressure stabilization resulting from pressure-dependent permeability or a region of much higher permeability located with a few meters of the well. The transmissivity estimates obtained from this analysis, converted to approximate fracture density and aperture, provide useful constraints on the distance to which the thermal front may migrate from the well during the cold water injection phase of the stimulation project. We estimate that the cooling front will migrate less than a tenth of a kilometer over an approximately one-year injection period. Here, the effects of that cooling, however, may be substantial, because increases in permeability have maximum effect nearest the well.

cold water injection↗

Flow properties in expansion tube with helium, argon, air, and CO2

Test flow velocities from 5 to 7 km/sec were generated in a 6-in. expansion tube using helium, argon, air, and CO2 test gases. Pitot pressure profiles across the flow at the test section are presented for the four test gases, and measured flow quantities are compared to computer predicted values. Comparison of predicted and measured flow quantities suggests the expansion to be near thermochemical equilibrium for all test gases and implies the existence of a totally reflected shock at the secondary diaphragm. Argon, air, and CO2 flows were observed to attenuate while traversing the acceleration section, whereas no attenuation was observed for helium.

Miller, C. G.↗

Flow Sensor Test Article (F-STAr) - Status Report for FY2021

This report will review updates on the status of F-STAr. First, the report will describe a general overview of the test article and how each component interacts. Then, each main component will be discussed in a deep dive section which will review the design and other relevant details. F-STAr components which are discussed in more detail include the 120 GPM-pump, the support structure and test sections, 5 kW-heater, the 2 kW-cooler and cooling system, and the submersible flowmeter. Finally, this report will conclude with a brief recap and a bulleted outline of the path moving forward.

42 ENGINEERING↗

Experimental study of flow distribution with circumferential manifolds

Water flow test results on fluid flow distribution and pressure loss in curved manifolds with tangential or radial entry are reported. Manifolds were studied both as inlet and outlet manifolds. Manifolds can be used for boilers and/or heat exchangers for advanced space electric power plants.

Dittrich, R. T.↗

Development of the technology for the fabrication of reliable laminar from control panels

Materials were assessed and fabrication techniques were developed for use in the manufacture of wing surface materials compatible with the application of both aluminum alloys and nonmetallic composites. The concepts investigated included perforations and slots in the metallic test panels and microporosity and perforations in the composite test panels. Perforations were produced in the metallic test panels by the electron beam process and slots were developed by controlled gaps between the metal sheets. Microporosity was produced in the composite test panels by the resin bleed process, and perforations were produced by the fugitive fiber technique. Each of these concepts was fabricated into test panels, and air flow tests were conducted on the panels.

Meade, L. E.↗

The NASA Lewis Research Center Internal Fluid Mechanics Facility

An experimental facility specifically designed to investigate internal fluid duct flows is described. It is built in a modular fashion so that a variety of internal flow test hardware can be installed in the facility with minimal facility reconfiguration. The facility and test hardware interfaces are discussed along with design constraints of future test hardware. The plenum flow conditioning approach is also detailed. Available instrumentation and data acquisition capabilities are discussed. The incoming flow quality was documented over the current facility operating range. The incoming flow produces well behaved turbulent boundary layers with a uniform core. For the calibration duct used, the boundary layers approached 10 percent of the duct radius. Freestream turbulence levels at the various operating conditions varied from 0.64 to 0.69 percent of the average freestream velocity.

Porro, A. R.↗

Oscillating-flow regenerator test rig: Woven screen and metal felt results

We present correlating expressions, in terms of Reynolds or Peclet numbers, for friction factors, Nusselt numbers, enhanced axial conduction ratios, and overall heat flux ratios in four porous regenerator samples representative of stirling cycle regenerators: two woven screen samples and two random wire samples. Error estimates and comparison of data with others suggest our correlations are reliable, but we need to test more samples over a range of porosities before our results will become generally useful.

Gedeon, D.↗

A computational investigation of fuel mixing in a hypersonic scramjet

A parabolized, Navier-Stokes code, SHIP3D, is used to numerically investigate the mixing between air injection and hydrogen injection from a swept ramp injector configuration into either a mainstream low-enthalpy flow or a hypervelocity test flow. The mixing comparisons between air and hydrogen injection reveal the importance of matching injectant-to-mainstream mass flow ratios. In flows with the same injectant-to-mainstream dynamic pressure ratio, the mixing definition was altered for the air injection cases. Comparisons of the computed results indicate that the air injection cases overestimate the mixing performance associated with hydrogen injection simulation. A lifting length parameter, to account for the time a fluid particle transverses through the mixing region, is defined and used to establish a connection of injectant mixing in hypervelocity flows, based on nonreactive, low-enthalpy flows.

Fathauer, Brett W.↗

Oscillating-flow regenerator test rig

This report summarizes work performed in setting up and performing tests on a regenerator test rig. An earlier status report presented test results, together with heat transfer correlations, for four regenerator samples (two woven screen samples and two felt metal samples). Lessons learned from this testing led to improvements to the experimental setup, mainly instrumentation as well as to the test procedure. Given funding and time constraints for this project it was decided to complete as much testing as possible while the rig was set up and operational, and to forego final data reduction and analysis until later. Additional testing was performed on several of the previously tested samples as well an on five newly fabricated samples. The following report is a summary of the work performed at OU, with many of the final test results included in raw data form.

Wood, J. G.↗

Aeroacoustic Characteristics of Model Jet Test Facility Flow Conditioners

An experimental investigation of flow conditioning devices used to suppress internal rig noise in high speed, high temperature experimental jet facilities is discussed. The aerodynamic and acoustic characteristics of a number of devices including pressure loss and extraneous noise generation are measured. Both aerodynamic and acoustic characteristics are strongly dependent on the porosity of the flow conditioner and the closure ratio of the duct system. For unchoked flow conditioners, the pressure loss follows conventional incompressible flow models. However, for choked flow conditioners, a compressible flow model where the duct and flow conditioner system is modeled as a convergent-divergent nozzle can be used to estimate pressure loss. Choked flow conditioners generate significantly more noise than unchoked conditioners. In addition, flow conditioners with small hole diameters or sintered metal felt material generate less self-noise noise compared to flow conditioners with larger holes.

Kinzie, Kevin W.↗

Madidrop for Passive Silver Dosing

Madidrop is a rectangular ceramic tablet originally designed to dose a 10-20-liter volume of water with silver to act as a biocide for remote communities with unreliable water sources. Silver as a biocide is a proposed method to control bacteria on the International Space Station or future Artemis missions. This would replace iodine currently used due to issues with a dual biocide system in place between Russian and US segments and the extra cost of iodine removal required before consumption. NASA has been reviewing this Madidrop technology and its potential application with a water reclamation system on orbit to dose silver after purifying the water. While there are a couple alternative methods to dosing silver on station, this method is like the existing passive dosing method used currently to dose iodine. Tests conducted characterize the manufacturer’s original intent to leave the tablet in a tank for a specified amount of time before removing and testing alternative passive flow-through methods. Passive flow testing involved two options: keeping the tablet intact or crushing the tablet into smaller particle sizes to increase the surface area while varying particle sizes. The results of these tests revealed a large amount of silver output at first that quickly reduced to a constant lower output within a reasonable dosing concentration range. The initial high concentration peaks after a couple days of quiescence and could be useful for shocking the initial tank water contents. Madidrop used as a passive particle doser could act as a stand-in replacement for iodine in future spaceflight water reclamation systems.

Ryan Ogilvie↗

Madidrop for Passive Silver Dosing

Madidrop is a rectangular ceramic tablet originally designed to dose a 10-20-liter volume of water with silver to act as a biocide for remote communities with unreliable water sources. Silver as a biocide is a proposed method to control bacteria on the International Space Station or future Artemis missions. This would replace iodine currently used due to issues with a dual biocide system in place between Russian and US segments and the extra cost of iodine removal required before consumption. NASA has been reviewing this Madidrop technology and its potential application with a water reclamation system on orbit to dose silver after purifying the water. While there are a couple alternative methods to dosing silver on station, this method is like the existing passive dosing method used currently to dose iodine. Tests conducted characterize the manufacturer’s original intent to leave the tablet in a tank for a specified amount of time before removing and testing alternative passive flow-through methods. Passive flow testing involved two options: keeping the tablet intact or crushing the tablet into smaller particle sizes to increase the surface area while varying particle sizes. The results of these tests revealed a large amount of silver output at first that quickly reduced to a constant lower output within a reasonable dosing concentration range. The initial high concentration peaks after a couple days of quiescence and could be useful for shocking the initial tank water contents. Madidrop used as a passive particle doser could act as a stand-in replacement for iodine in future spaceflight water reclamation systems.

Ryan Ogilvie↗