Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Working Fluid Trade Study for a Two-Phase Mechanically Pumped Loop Thermal Control System

NASA Jet Propulsion Laboratory is investigating a two-phase mechanically pumped fluid loop (MPFL) technology for spacecraft thermal control for future planetary space science mission concepts. The two-phase technology combines the potential of single-phase MPFL and the passive two-phase heat pipe systems. Previous two-phase MPFL studies at JPL have identified an evaporator system with a separated flow architecture as providing a robust light mass thermal control system with very high spatial and temporal thermal stability required by the science instruments on these missions. These studies have further identified the thermophysical properties of the working fluid to be key to the performance of a two-phase fluid loop. This paper describes the methodology used in the selection of the working fluids for optimizing the performance of the two-phase MPFL. A high level model was developed that includes the constraints and boundaries driven by the system components. The performance of fluids from the REFPROP database are investigated and rated for this system. The working fluid attributes such as cost, hazardous properties, and heritage were taken into account in this selection. A typical spacecraft dissipating 1000 W and a fluid loop consisting of an evaporator, accumulator, radiator, and associated tubing components is used as an example in this study.

Daimaru, Takuro↗

Working Fluid Trade Study for a Two-Phase Mechanically Pumped Loop Thermal Control System

NASA Jet Propulsion Laboratory is investigating a two-phase mechanically pumped fluid loop (MPFL) technology for spacecraft thermal control for future planetary space science mission concepts. The two-phase technology combines the potential of single-phase MPFL and the passive two-phase heat pipe systems. Previous two-phase MPFL studies4,5 at JPL have identified an evaporator system with a separated flow architecture as providing a robust light mass thermal control system with very high spatial and temporal thermal stability required by the science instruments on these missions. These studies have further identified the thermophysical properties of the working fluid to be key to the performance of a two-phase fluid loop. This paper describes the methodology used in the selection of the working fluids for optimizing the performance of the two-phase MPFL. A high level model was developed that includes the constraints and boundaries driven by the system components. The performance of fluids from the REFPROP database were investigated and rated for this system. The working fluid attributes such as cost, hazardous properties, and heritage were taken into account in this selection. A typical spacecraft dissipating 1000 W and a fluid loop consisting of an evaporator, accumulator, radiator, and associated tubing components was used as an example in this study.

Daimaru, Takuro↗

Mitigating Headward Fluid Shifts With Veno-Constrictive Thigh Cuffs During Spaceflight

Astronauts experience a chronic headward fluid shift in weightlessness as evidenced by increased cardiac output, decreased leg volume, a redistribution of venous fluid, and venous congestion in the upper body. Alterations in cerebrospinal fluid hydrodynamics and changes in cerebral venous pressure secondary to the headward fluid shift may contribute to ocular changes associated with spaceflight-associated neuro-ocular syndrome (SANS). Veno-constrictive thigh cuffs (VTC; Braslets) provided to Soyuz crewmembers alleviate symptoms of the headward fluid shift during the first week of spaceflight and have been documented to reduce internal jugular vein (IJV) distension during weightlessness. Application of VTCs designed collaboratively by NASA Johnson Space Center Cardiovascular and Vision Laboratory (CVL) and Clemson Textile Laboratory at Clemson University to improve fit and comfort was documented to mitigate changes in choroid thickness, intraocular pressure, and IJV area during posture-induced headward fluid shifts. VTC are demonstrated to reduce headward fluid shifts in both ground-based and spaceflight studies, and thus, may be a countermeasure against development of SANS. In addition, VTC are a simple mechanical countermeasure currently at a high technical readiness level (TRL) and are compact and lightweight, making them compatible with the spaceflight operations environment

Connor R. Ferguson↗

Characterization Of Early Solar System Aqueous Fluids

The most direct and convincing evidence for the presence of water and organic molecules on protoplanetary bodies is provided by fluid inclusions trapped in secondary minerals. Our research has demonstrated that early solar system fluids have survived as fluid inclusions in a few astromaterials that escaped significant shock, terrestrial alteration, and invasive sample handling. Our long-term goal is to measure bulk molecular and isotopic composition of individual fluid inclusions in meteorites and samples collected directly from asteroids to provide ground truth regarding the nature and evolution of aqueous fluids in the early solar system. Our current protocol is to locate candidate fluid inclusions using X-Ray Computed Tomography, and then make compositional measurements of individual fluid inclusions by coordinated Raman spectrometry, Transmission Electron Microscopy and, most recently, Time of Flight – Secondary Ion Mass Spectrometry.

Michael Zolensky↗

Fluid System Stability Analysis Techniques

Fluid systems, or networks, consist of multiple components that work together to achieve some desired thermofluid state. For any generic application, this fluid state can be a combination of the fluid pressure, flow rate, enthalpy, or species concentration. Fluid system components, such as pumps and valves, are often governed by nonlinear differential equations, resulting in complex component-to-component interactions. System-level fluid network stability occurs when the flow through the system can maintain a steady-state solution in the presence of small perturbations, which depends on these component interactions. System instability, however, can go undetected until issues arise during integrated system testing. This presentation explores a method for system designers to think of the fluid network as an assembly of components, each with their own thermofluid surfaces of partial stability, called nullclines. The intersections of all nullclines yields system-level solutions, called equilibrium points. When designers define operating points, they are tuning system parameters so that these equilibrium points move to the desired location in the thermofluid state plane. However, linearization theory shows us that the dynamic behavior around these points can be unstable. The local stability of these equilibrium points can be assessed analytically with eigen-analysis, or numerically by propagating state-plane samples to construct a phase portrait. Investigating a phase portrait can help designers gain a qualitative understanding of a system’s dynamic performance. This understanding can then help inform requirement definitions, component selection, and operational procedures. This presentation includes an example of the phase portrait technique on a system featuring a centrifugal pump and a back-pressure regulator (BPR). Numerical modeling of this system suggests that equilibrium points on the left-hand side of the pump curve are dynamically unstable.

Fluid System↗

Effect of fluid ingestion on orthostatic responses following acute exercise

Orthostatic tolerance is impaired following an acute bout of exercise. This study examined the effect of fluid ingestion following treadmill exercise in restoring the cardiovascular responses to an orthostatic stress. Five men (age, 29.6 +/- 3.4 yrs) were exposed to a graded lower body negative (LBNP) pressure protocol (0 to -50 mmHg) during euhydration without exercise (C), 20 minutes after exercise dehydration (D), 20 minutes after exercise and fluid ingestion (FI20), and 60 minutes after exercise and fluid ingestion (FI60). Fluid ingestion (mean +/- SE) consisted of water-ingestion equivalent to 50% of the body weight lost during exercise (520 +/- 15 ml). Exercise dehydration resulted in significantly higher heart rates (119 +/- 8 vs 82 +/- 7 bpm), lower systolic blood pressures (95 +/- 1.7 vs 108 +/- 2.3 mmHg), a smaller increase in leg circumference (3.7 +/- 4 vs 6.9 +/- 1.0 mm), and an attenuated increase in total peripheral resistance (2.58 +/- 1.2 vs 4.28 +/- 0.9 mmHg/L/min) at -50 mmHg LBNP compared to the C condition. Fluid ingestion (both 20 and 60), partially restored the heart rate, systolic blood pressure, and total peripheral resistance responses to LBNP, but did not influence the change in leg circumference during LBNP (4 +/- 0.3 for R20 and 2.8 +/- 0.4 mm for R60). These data illustrate the effectiveness of fluid ingestion on improving orthostatic responses following exercise, and suggest that dehydration is a contributing factor to orthostatic intolerance following exercise.

NASA Center JSC↗

NASA Fluid Lensing & MiDAR: Next-Generation Remote Sensing Technologies for Aquatic Remote Sensing

We present two recent instrument technology developments at NASA, Fluid Lensing and MiDAR, and their application to remote sensing of Earth's aquatic systems. Fluid Lensing is the first remote sensing technology capable of imaging through ocean waves in 3D at sub-cm resolutions. MiDAR is a next-generation active hyperspectral remote sensing and optical communications instrument capable of active fluid lensing. Fluid Lensing has been used to provide 3D multispectral imagery of shallow marine systems from unmanned aerial vehicles (UAVs, or drones), including coral reefs in American Samoa and stromatolite reefs in Hamelin Pool, Western Australia. MiDAR is being deployed on aircraft and underwater remotely operated vehicles (ROVs) to enable a new method for remote sensing of living and nonliving structures in extreme environments. MiDAR images targets with high-intensity narrowband structured optical radiation to measure an objectâ€"TM"s non-linear spectral reflectance, image through fluid interfaces such as ocean waves with active fluid lensing, and simultaneously transmit high-bandwidth data. As an active instrument, MiDAR is capable of remotely sensing reflectance at the centimeter (cm) spatial scale with a signal-to-noise ratio (SNR) multiple orders of magnitude higher than passive airborne and spaceborne remote sensing systems with significantly reduced integration time. This allows for rapid video-frame-rate hyperspectral sensing into the far ultraviolet and VNIR wavelengths. Previously, MiDAR was developed into a TRL 2 laboratory instrument capable of imaging in thirty-two narrowband channels across the VNIR spectrum (400-950nm). Recently, MiDAR UV was raised to TRL4 and expanded to include five ultraviolet bands from 280-400nm, permitting UV remote sensing capabilities in UV A, B, and C bands and enabling mineral identification and stimulated fluorescence measurements of organic proteins and compounds, such as green fluorescent proteins in terrestrial and aquatic organics.

fluid lensing↗

Fluid System Stability Analysis Techniques

Fluid systems, or networks, consist of multiple components that work together to achieve some desired thermofluid state. For any generic application, this fluid state can be a combination of the fluid pressure, flow rate, enthalpy, or species concentration. Fluid system components, such as pumps and valves, are often governed by nonlinear differential equations, resulting in complex component-to-component interactions. System-level fluid network stability occurs when the flow through the system can maintain a steady-state solution in the presence of small perturbations, which depends on these component interactions. System instability, however, can go undetected until issues arise during integrated system testing. This presentation explores a method for system designers to think of the fluid network as an assembly of components, each with their own thermofluid surfaces of partial stability, called nullclines. The intersections of all nullclines yields system-level solutions, called equilibrium points. When designers define operating points, they are tuning system parameters so that these equilibrium points move to the desired location in the thermofluid state plane. However, linearization theory shows us that the dynamic behavior around these points can be unstable. The local stability of these equilibrium points can be assessed analytically with eigen-analysis, or numerically by propagating state-plane samples to construct a phase portrait. Investigating a phase portrait can help designers gain a qualitative understanding of a system’s dynamic performance. This understanding can then help inform requirement definitions, component selection, and operational procedures. This presentation includes an example of the phase portrait technique on a system featuring a centrifugal pump and a back-pressure regulator (BPR). Numerical modeling of this system suggests that equilibrium points on the left-hand side of the pump curve are dynamically unstable.

Fluid System↗

Mineral and fluid transformation of hydraulically fractured shale: case study of Caney Shale in Southern Oklahoma

This study explores the geochemical reactions that can cause permeability loss in hydraulically fractured reservoirs. The experiments involved the reaction of powdered-rock samples with produced brines in batch reactor system at temperature of 95 °C and atmospheric pressure for 7-days and 30-days respectively. Results show changes in mineralogy and chemistry of rock and fluid samples respectively, therefore confirming chemical reactions between the two during the experiments. The mineralogical changes of the rock included decreases of pyrite and feldspar content, whilst carbonate and illite content showed an initial stability and increase respectively before decreasing. Results from analyses of post-reaction fluids generally corroborate the results obtained from mineralogical analyses. Integrating the results obtained from both rocks and fluids reveal a complex trend of reactions between rock and fluid samples which is summarized as follows. Dissolution of pyrite by oxygenated fluid causes transient and localized acidity which triggers the dissolution of feldspar, carbonates, and other minerals susceptible to dissolution under acidic conditions. The dissolution of minerals releases high concentrations of ions, some of which subsequently precipitate secondary minerals. On the field scale, the formation of secondary minerals in the pores and flow paths of hydrocarbons can cause significant reduction in the permeability of the reservoir, which will culminate in rapid productivity decline. This study provides an understanding of the geochemical rock–fluid reactions that impact long term permeability of shale reservoirs.

58 GEOSCIENCES↗

Pump for delivering heated fluids

A thermomechanical pump particularly suited for use in pumping a warming fluid obtained from an RTG (Radioisotope Thermal Generator) through science and flight instrumentation aboard operative spacecraft is described. The invention is characterized by a pair of operatively related cylinders, each including a reciprocating piston head dividing the cylinder into a pressure chamber confining therein a vaporizable fluid, and a pumping chamber for propelling the warming fluid, and a fluid delivery circuit for alternately delivering the warming fluid from the RTG through the pressure chamber of one cylinder to the pumping chamber of the other cylinder, whereby the vaporizable fluid within the pair of pressure chambers alternately is vaporized and condensed for driving the associated pistons in pumping and intake strokes.

Sabelman, E. E.↗

Heater-mixer for stored fluids

A fluid storage vessel for containing cryogenic fluids is described. The storage vessel contains an auxiliary chamber which is connected to the main container by a jet nozzle. The wall of the auxiliary vessel is heat cycled to produce a corresponding expansion and contraction of the fluid within the auxiliary chamber. This action causes heating and mixing of the stored fluid by means of jetting the expanded fluid to and from relative to the stored fluid contents of the vessel.

Canning, T. N.↗

Synthesis and evaluation of C-ether formulations for use as high temperature lubricants and hydraulic fluids

The formulation and evaluation of C-ether fluids for use in the hydraulic and lubrication systems of the space shuttle and advanced air breathing engines were studied to lower the pour point of a reference C-ether from -29 C to -40 C without changing its evaporation loss. Use of disiloxanes mixed with C-ethers gave a -40 C pour point fluid with little change in the desired evaporation loss or in oxidative stability. A second -40 C pour point fluid containing only C-ethers was also developed. A screening program tested lubrication additives for C-ethers and the new fluids. Six additive packages were chosen for evaluation in 316 C bearing tests, two for evaluation in 260 C pump tests. The goal of the bearing test was a 100 hour run. The rig was a specially designed 80-mm axially loaded ball bearing. The C-ether base fluid ran only one hour at 316 C before cage wear failure occurred. The best additive blends ran 47, 94 and 100 hours. The 96 hour test gave excessive deposits. The 100 hour test had no wear failures; an unexplained loss of cage silver occurred from areas of direct fluid impingement on the cage.

Clark, F. S.↗

Fluid mass sensor for a zero gravity environment

A sensor for measuring the mass of fluids, is described which includes a housing having an inlet and outlet for receiving and dumping the fluid, a rotary impeller within the housing for imparting centrifugal motion to the fluid and a pressure sensitive transducer attached to the housing to sense the rotating fluid pressure. The fluid may be drawn into the housing by entrainment within a gas stream. The resulting mixture is then separated into two phases: gas and liquid. The gas is removed from the housing and the pressure of the liquid, under centrifugal motion, is sensed and correlated with the mass of the fluid.

Fogal, G. L.↗

A finite element-analytical method for modeling a structure in an infinite fluid

A method is described from which the interaction of an elastic structure with an infinite acoustic fluid is determined. The displacements of the structure and the pressure field of the immediate surrounding fluid are modeled by finite elements, and the remaining pressure field of the infinite fluid region is given by an analytical expression. This method yields a frequency dependent boundary condition for the outer fluid boundary when applied to the frequency response of an elastic beam in contact with an acoustic fluid. The frequency response of the beam is determined using NASTRAN, and compares favorably to the exact solution which is also presented. The effect of the fluid on the response of the structure at low and high frequencies is due to added mass and damping characteristics, respectively.

Zarda, P. R.↗

Fluid sampling device

An inlet leak is described for sampling gases, more specifically, for selectively sampling multiple fluids. This fluid sampling device includes a support frame. A plurality of fluid inlet devices extend through the support frame and each of the fluid inlet devices include a longitudinal aperture. An opening device that is responsive to a control signal selectively opens the aperture to allow fluid passage. A closing device that is responsive to another control signal selectively closes the aperture for terminating further fluid flow.

Studenick, D. K.↗

Fluid valve assembly

A valve assembly is reported for controlling the flow of fluids between the inlet and outlet of a fluid valve. The valve assembly contains a barrier element which is porous for providing fluid communication between the valve inlet and outlet. The valve assembly also includes a sealing element that is movable relative to the barrier element between a first position, in which fluid flow through the porous portion of the barrier element is blocked preventing fluid communication between the valve inlet and outlet, and a second position, in which the porous portion is unblocked, permitting fluid communication between the valve inlet and outlet.

Huber, W. C.↗

Bed-rest studies: Fluid and electrolyte responses

Confinement in the horizontal position for 2 to 3 weeks results in a chronic decrease in plasma volume, increased interstitial fluid volume, and unchanged or slightly increased extracellular fluid volume. Concentrations of blood electrolytes, glucose, and nitrogenous constituents remain within normal limits of variability when maintenance levels of isometric or isotonic exercise are performed for 1 hr/day. Hematocrit and plasma osmolality can be elevated significantly throughout bed rest (BR). Significant diuresis occurs on the first day, and increases in urine Na and Ca continue throughout BR, although voluntary fluid intake is unchanged. Urine Na and K are evaluated during the second week of BR in spite of stabilization of PV and extracellular volume. The initial diuresis probably arises from the extracellular fluid while subsequent urine loss above control levels must come from the intracellular fluid. Preservation of the extracellular volume takes precedance over maintenance of the intracellular fluid volume. The functioning of a natriuretic factor (hormone) to account for the continued increased loss of Na in the urine is suggested.

Greenleaf, J. E.↗

Physiological and behavioral effects of tilt-induced body fluid shifts

This paper addresses the 'fluid shift theory' of space motion sickness. The primary purpose of the research was the development of procedures to assess individual differences in response to rostral body fluid shifts on earth. Experiment I examined inner ear fluid pressure changes during head-down tilt in intact human beings. Tilt produced reliable changes. Differences among subjects and between ears within the same subject were observed. Experiment II examined auditory threshold changes during tilt. Tilt elicited increased auditory thresholds, suggesting that sensory depression may result from increased inner ear fluid pressure. Additional observations on rotation magnitude estimation during head-down tilt, which indicate that rostral fluid shifts may depress semicircular canal activity, are briefly described. The results of this research suggest that the inner ear pressure and auditory threshold shift procedures could be used to assess individual differences among astronauts prior to space flight. Results from the terrestrial observations could be related to reported incidence/severity of motion sickness in space and used to evaluate the fluid shift theory of space motion sickness.

Parker, D. E.↗