Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluorescent imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Imaging of Combustion Species in a Radially-Staged Gas Turbine Combustor

Plannar laser-induced fluorescence (PLIF) is used to characterize the complex flowfield of a unique fuel-lean, radially-staged high pressure gas turbine combustor. PLIF images of OH are presented for two fuel injector configurations. PLIF images of NO, the first acquired at these conditions, are presented and compared with gas sample extraction probe measurements. Flow field imaging of nascent C2 chemiluminescence is also investigated. An examination is made of the interaction between adjoining lean premixed prevaporized (LPP) injectors. Fluorescence interferences at conditions approaching 2000 K and 15 atm are observed and attributed to polycyclic aromatic hydrocarbon (PAH) emissions. All images are acquired at a position immediately downstream of the fuel injectors with combustor burning JP-5 fuel.

Locke, Randy J.↗

Multistep fluorescence gated proportional counters

A proportional counter is introduced in which the levels of energy and spatial resolutions and background rejection permit the application of the device to X-ray astronomy. A multistep approach is employed in which photons cause a signal that triggers the system and measures the energy of the incident photon. The multistep approach permits good energy resolution from parallel geometry and from the imaging stage due to coupling of the imaging and amplification stages. The design also employs fluorescence gating to reduce background, a method that is compatible with the multistep technique. Use of the proportional counter is reported for NASA's supernova campaign, and the pair background is below 0.0001 counts/sq cm sec keV at the xenon k-edge. Potential improvements and applications are listed including the CASES, POF, and EXOSS mission programs.

Ramsey, Brian D.↗

The first 300 sols of the SHERLOC investigation on the Mars 2020 rover

The Mars2020 mission is NASA’s latest flagship mission to Mars. The spacecraft launched in July 2020, and landed in Jezero crater on February 18, 2021 at the Octavia Butler Landing site. The rocks and sediments of Jezero crater have been argued to have preserved records of past, potentially habitable environments. The mission is characterizing the field site by analyzing chemistry, looking for organics and searching for potential biosignatures. The Scanning Habitable Environments with Ra-man and Luminescence for Organics and Chemicals (SHERLOC) is a robotic arm mounted instrument. SHERLOC combines imaging with UV resonance Raman and native deep UV fluorescence spectroscopy to identify potential biosignatures and understand the aqueous history of the Jezero Region. WATSON (Wide Angle Topographic Sensor for Operations and eNgineering), a refight of the Mars Hand Lens Imager (MAHLI) on the Curiosity rover is capable of color imaging over a wide range of resolutions (from infinity to 13.1 micron/pixel) and is used for both science and engineering. A second imager, the Autofocusing Con-textual Imager (ACI), produces gray scale images at 10.1 micron/pixel resolution at a 48 mm range.

A. E. Murphy↗

Qualitative and quantitative flow visualization technique using ozone

The paper describes a new flow-visualization technique based on the absorption of ultraviolet light by ozone. Ozone is an excellent tracer, because as a gas it has the same effective physical properties as air. Ozone strongly absorbs the principal line (253.7 nm) of a mercury lamp, so that when an ozone-traced flow passes between a mercury lamp and a fluorescent screen, a sharp, shadow-like image of the ozone tracer is cast on the screen. Quantitative photometry can be carried out by replacing the screen with ultraviolet detectors that yield the path-integrated column density of ozone in the flow. High-speed quantitative point monitoring (10 Hz at 10 ppb O3) is possible with capillary probes and chemiluminescent analysis.

Dickerson, R. R.↗

Development of a Premixed Combustion Capability for Scramjet Combustion Experiments

Hypersonic air-breathing engines rely on scramjet combustion processes, which involve high speed, compressible, and highly turbulent flows. The combustion environment and the turbulent flames at the heart of these engines are difficult to simulate and study in the laboratory under well controlled conditions. Typically, wind-tunnel testing is performed that more closely approximates engine testing rather than a careful investigation of the underlying physics that drives the combustion process. The experiments described in this paper, along with companion data sets being developed separately, aim to isolate the chemical kinetic effects from the fuel-air mixing process in a dual-mode scramjet combustion environment. A unique fuel injection approach is taken that produces a nearly uniform fuel-air mixture at the entrance to the combustor. This approach relies on the precombustion shock train upstream of the dual-mode scramjet combustor. A stable ethylene flame anchored on a cavity flameholder with a uniformly mixed combustor inflow has been achieved in these experiments allowing numerous companion studies involving coherent anti-Stokes Raman scattering (CARS), particle image velocimetry (PIV), and planar laser induced fluorescence (PLIF) to be performed.

Rockwell, Robert D.↗

Nitric Oxide PLIF Measurements in the Hypersonic Materials Environmental Test System (HYMETS)

A nonintrusive laser-based measurement system has been applied for the first time in the HYMETS (Hypersonic Materials Environmental Test System) 400 kW arc-heated wind tunnel at NASA Langley Research Center. Planar laser-induced fluorescence of naturally occurring nitric oxide (NO) has been used to obtain instantaneous flow visualization images, and to make both radial and axial velocity measurements. Results are presented at selected facility run conditions, including some in simulated Earth atmosphere (75% nitrogen, 20% oxygen, 5% argon) and others in simulated Martian atmosphere (71% carbon dioxide, 24% nitrogen, 5% argon), for bulk enthalpies ranging from 6.5 MJ/kg to 18.4 MJ/kg. Flow visualization images reveal the presence of large scale unsteady flow structures, and indicate nitric oxide fluorescence signal over more than 70% of the core flow for bulk enthalpies below about 11 MJ/kg, but over less than 10% of the core flow for bulk enthalpies above about 16 MJ/kg. Axial velocimetry was performed using molecular tagging velocimetry (MTV). Axial velocities of about 3 km/s were measured along the centerline. Radial velocimetry was performed by scanning the wavelength of the narrowband laser and analyzing the resulting Doppler shift. Radial velocities of 0.5km/s were measured.

Inman, Jennifer A.↗

Imaging of lunar surface chemistry from orbital X-ray data

Color images of the lunar surface from 20 deg W to 120 deg E were prepared which map the variations in the distribution of Al, Mg, and Si as expressed by the ratios of the Al/Si and the Mg/Al fluorescent X-ray intensities. Through the use of image enhancement techniques developed for the La Jolla Consortium on remote sensing of the moon, detailed information previously unobserved has been made available. The frequency distribution of the Apollo 15 and 16 intensity ratios for individual 0.25 x 0.25 deg surface units is clearly bimodal, peaking at 0.81 for mare material and 1.12 for nearside highland material, which values correspond to concentration ratios of 0.39 and 0.54, respectively, for Al/Si.

Bielefeld, M. J.↗

Qualitative and quantitative imaging in microgravity combustion

An overview of the imaging techniques implemented by researchers in the microgravity combustion program shows that for almost any system, imaging of the flame may be accomplished in a variety of ways. Standard and intensified video, high speed, and infrared cameras and fluorescence, laser schlieren, rainbow schlieren, soot volume fraction, and soot temperature imaging have all been used in the laboratory and many in reduced gravity to make the necessary experimental measurements.

Weiland, Karen J.↗

Kinetics of antigen binding to arrays of antibodies in different sized spots

A fluorescence-based array biosensor has been developed which can measure the binding kinetics of an antigen to an immobilized antibody in real time. A patterned array of antibodies immobilized on the surface of a planar waveguide was used to capture a Cy5-labeled antigen present in a solution that was continuously flowed over the surface. The CCD image of the waveguide was monitored continuously for 25 min. The resulting exponential rise in fluorescence signal was determined by image analysis software and fitted to a reaction-limited kinetics model, giving a kf of 3.6 x 10(5) M(-1) s(-1). Different spot sizes were then patterned on the surface of the waveguide using either a PDMS flow cell or laser exposure, producing width sizes ranging from 80 to 1145 microm. It was demonstrated that under flow conditions, the reduction of spot size did not alter the association rate of the antigen with immobilized antibody; however, as the spot width decreased to < 200 nm, the signal intensity also decreased.

Non-NASA Center↗

Nitric Oxide PLIF Measurements in the Hypersonic Materials Environmental Test System (HYMETS)

Planar laser-induced fluorescence (PLIF) of naturally occurring nitric oxide (NO) has been used to obtain instantaneous flow visualization images, and to make both radial and axial velocity measurements in the HYMETS (Hypersonic Materials Environmental Test System) 400 kW arc-heated wind tunnel at NASA Langley Research Center. This represents the first application of NO PLIF flow visualization in HYMETS. Results are presented at selected facility run conditions, including some in a simulated Earth atmosphere (75% nitrogen, 20% oxygen, 5% argon) and others in a simulated Martian atmosphere (71% carbon dioxide, 24% nitrogen, 5% argon), for specific bulk enthalpies ranging from 6.5 MJ/kg to 18.4 MJ/kg. Flow visualization images reveal the presence of large scale unsteady flow structures, and indicate nitric oxide fluorescence signal over more than 70% of the core flow for specific bulk enthalpies below about 11 MJ/kg, but over less than 10% of the core flow for specific bulk enthalpies above about 16 MJ/kg. Axial velocimetry was performed using molecular tagging velocimetry (MTV). Axial velocities of about 3 km/s were measured along the centerline. Radial velocimetry was performed by scanning the wavelength of the narrowband laser and analyzing the resulting Doppler shift. Radial velocities of +/- 0.5 km/s were measured.

Inman, Jennifer A.↗

Global Skin-Friction Measurements Using Particle Image Surface FLow Visualization and a Luminescent Oil-Film

A quantitative global skin-friction measurement technique is proposed. An oil-film is doped with a luminescent molecule and thereby made to fluoresce in order to resolve oil-film thickness, and Particle Image Surface Flow Visualization is used to resolve the velocity field of the surface of the oil-film. Skin-friction is then calculated at location x as (x )xh, where x is the displacement of the surface of the oil-film and is the dynamic viscosity of the oil. The data collection procedure and data analysis procedures are explained, and preliminary experimental skin-friction results for flow over the wing of the CRM are presented.

FISF↗

Near-infrared observations of the proto-planetary nebula AFGL 618

Near-IR images and spectroscopy of the bipolar protoplanetary nebula AFGL 618 are presented. Emission from molecular hydrogen is detected in the 0.90-1.34-micron spectrum. A visual extinction of 3.4 +4.0/-2.0 mag to the H2-emitting region is derived from molecular hydrogen line ratios. Models of collisionally excited and fluorescent H2 emission are compared with the data: the near-IR H2 spectrum is found to be dominated by emission from collisionally excited molecules at Tex of about 2000 K, but a component of fluorescent emission is also present. It is shown that this type of near-IR spectrum is an excellent tool for discriminating relatively low levels of fluorescent H2 emission from a strong collisionally excited component. Images in the H- and K-bandpasses are analyzed using models which assume single scattering of photons from the central objects. The models indicate that the bipolar axis is inclined to the plane of the sky by about 45 deg. The emission in the H- and K-bands is found to be consistent with single scattering of photons by dust with a distribution such that the dust density increases with increasing stellar latitude and is nearly zero at the poles.

Latter, William B.↗

Stereo Imaging Velocimetry of Mixing Driven by Buoyancy Induced Flow Fields

Mixing of two fluids generated by steady and particularly g-jitter acceleration is fundamental towards the understanding of transport phenomena in a microgravity environment. We propose to carry out flight and ground-based experiments to quantify flow fields due to g-jitter type of accelerations using Stereo Imaging Velocimetry (SIV), and measure the concentration field using laser fluorescence. The understanding of the effects of g-jitter on transport phenomena is of great practical interest to the microgravity community and impacts the design of experiments for the Space Shuttle as well as the International Space Station. The aim of our proposed research is to provide quantitative data to the community on the effects of g-jitter on flow fields due to mixing induced by buoyancy forces. The fundamental phenomenon of mixing occurs in a broad range of materials processing encompassing the growth of opto-electronic materials and semiconductors, (by directional freezing and physical vapor transport), to solution and protein crystal growth. In materials processing of these systems, crystal homogeneity, which is affected by the solutal field distribution, is one of the major issues. The understanding of fluid mixing driven by buoyancy forces, besides its importance as a topic in fundamental science, can contribute towards the understanding of how solutal fields behave under various body forces. The body forces of interest are steady acceleration and g-jitter acceleration as in a Space Shuttle environment or the International Space Station. Since control of the body force is important, the flight experiment will be carried out on a tunable microgravity vibration isolation mount, which will permit us to precisely input the desired forcing function to simulate a range of body forces. To that end, we propose to design a flight experiment that can only be carried out under microgravity conditions to fully exploit the effects of various body forces on fluid mixing. Recent flight experiments, by the P.I. through collaboration with the Canadian Space Agency (STS-85, August 1997), aimed at determining the stability of the interface between two miscible liquids inside an enclosure show that a long liquid column (5 cm) under microgravity isolation conditions can be stable, i.e. the interface remains sharp and vertical over a short time scale; thus transport occurs by molecular mass diffusion. On the other hand, when the two liquids were excited from a controlled vibration source (Microgravity Vibration Isolation Mount) two to four mode large amplitude quasi-stationary waves were observed. The data was limited to CCD recording of the dynamics of the interface between the two fluids. We propose to carry out flight experiments to quantify the dynamics of the flow field using Stereo Imaging Velocimetry and measure the concentration field using laser fluorescence. The results will serve as a basis to understand effects of g-jitter on transport phenomena, in this case mass diffusion. As the measurement of the kinematics of the flow field will shed light on the instability mechanism. The research will allow measurement of the flow field in microgravity environment to prove two hypotheses: (1) Maxwell's hypothesis: finite convection always exists in diffusing systems, and (2) Quasi-stationary waves inside a bounded enclosure in a microgravity environment is generated by Kelvin-Helmholtz instability; resonance of the interface which produces incipient mixing is due to Rayleigh-Taylor instability. The first hypothesis can be used as a benchmark experiment to illustrate diffusive mixing. The second hypothesis will lead to the understanding of g-jitter effects on buoyancy driven flow fields which occur in many situations involving materials processing, and other basic fluid physics phenomena. In addition, the second hypothesis will also provide insight in how Rayleigh-Taylor and Kelvin-Helmholtz instabilities propagate concentration fronts during mixing. Measurement of the flow field using SIV is important because it is the flow field which causes instability at the interface between the two fluids. Mixing driven by buoyancy induced flow fields will be addressed both experimentally and computationally. The experimental effort will address the kinematics of mixing: stretching, transport and chaos. Quantification of the mechanisms of mixing will consists of measuring the flow field using the SIV system at Glenn and capturing the dynamics of the interface, to measure mass transport, using a CCD camera. These experiments will be carried out within the framework of Earth's gravity and g-jitter microgravity acceleration as in a Space Shuttle environment or the International Space Station. The g-jitter will be induced and controlled using a tunable vibration isolation platform to isolate against vibration as well as input periodic and random vibration to the system. The parametric range of the microgravity experiment will be extended from the experiments on STS-85 to investigate higher mode quasi-stationary waves (8 to 12), as well as resonance regions which leads to chaos and turbulence. Ground-based experiments will focus on effects of vibration on stably stratified fluid layers in order to scale for possible scenarios in a microgravity environment. These vibrations will be subjected perpendicular to the concentration field on the ground since the parallel case can only be carried out in a microgravity environment. The concept of dynamical similarity will be applied to tune the experiments as closely as possible to a Space Shuttle environment or the International Space Station. The computational effort will take advantage of the Computational Laboratory at Glenn to corroborate the experimental findings with predictions of the dynamics of the flow field using the codes FLUENT (finite difference based) and FIDAP (finite element based). We will investigate two important cases, single-fluid model to address dilute systems with negligible jump in viscosity and the more general two-fluid model which accounts for finite jump in viscosity. Apart from its microgravity relevance, this experiment is well suited to study dynamics in nonlinear systems.

Duval, W. M. B.↗

Contamination detection NDE for cleaning process inspection

In the joining of multilayer materials, and in welding, the cleanliness of the joining surface may play a large role in the quality of the resulting bond. No non-intrusive techniques are currently available for the rapid measurement of contamination on large or irregularly shaped structures prior to the joining process. An innovative technique for the measurement of contaminant levels in these structures using laser based imaging is presented. The approach uses an ultraviolet excimer laser to illuminate large and/or irregular surface areas. The UV light induces fluorescence and is scattered from the contaminants. The illuminated area is viewed by an image-intensified CCD (charge coupled device) camera interfaced to a PC-based computer. The camera measures the fluorescence and/or scattering from the contaminants for comparison with established standards. Single shot measurements of contamination levels are possible. Hence, the technique may be used for on-line NDE testing during manufacturing processes.

Marinelli, W. J.↗

Imaging Dot Patterns for Measuring Gossamer Space Structures

A paper describes a photogrammetric method for measuring the changing shape of a gossamer (membrane) structure deployed in outer space. Such a structure is typified by a solar sail comprising a transparent polymeric membrane aluminized on its Sun-facing side and coated black on the opposite side. Unlike some prior photogrammetric methods, this method does not require an artificial light source or the attachment of retroreflectors to the gossamer structure. In a basic version of the method, the membrane contains a fluorescent dye, and the front and back coats are removed in matching patterns of dots. The dye in the dots absorbs some sunlight and fluoresces at a longer wavelength in all directions, thereby enabling acquisition of high-contrast images from almost any viewing angle. The fluorescent dots are observed by one or more electronic camera(s) on the Sun side, the shade side, or both sides. Filters that pass the fluorescent light and suppress most of the solar spectrum are placed in front of the camera(s) to increase the contrast of the dots against the background. The dot image(s) in the camera(s) are digitized, then processed by use of commercially available photogrammetric software.

Dorrington, A. A.↗

NASA Tech Briefs, April 2004

Topics covered include: Analysis of SSEM Sensor Data Using BEAM; Hairlike Percutaneous Photochemical Sensors; Video Guidance Sensors Using Remotely Activated Targets; Simulating Remote Sensing Systems; EHW Approach to Temperature Compensation of Electronics; Polymorphic Electronic Circuits; Micro-Tubular Fuel Cells; Whispering-Gallery-Mode Tunable Narrow-Band-Pass Filter; PVM Wrapper; Simulation of Hyperspectral Images; Algorithm for Controlling a Centrifugal Compressor; Hybrid Inflatable Pressure Vessel; Double-Acting, Locking Carabiners; Position Sensor Integral with a Linear Actuator; Improved Electromagnetic Brake; Flow Straightener for a Rotating-Drum Liquid Separator; Sensory-Feedback Exoskeletal Arm Controller; Active Suppression of Instabilities in Engine Combustors; Fabrication of Robust, Flat, Thinned, UV-Imaging CCDs; Chemical Thinning Process for Fabricating UV-Imaging CCDs; Pseudoslit Spectrometer; Waste-Heat-Driven Cooling Using Complex Compound Sorbents; Improved Refractometer for Measuring Temperatures of Drops; Semiconductor Lasers Containing Quantum Wells in Junctions; Phytoplankton-Fluorescence-Lifetime Vertical Profiler; Hexagonal Pixels and Indexing Scheme for Binary Images; Finding Minimum-Power Broadcast Trees for Wireless Networks; and Automation of Design Engineering Processes.

Source record↗

A perspective view of the plane mixing layer

A three-dimensional model of the plane mixing layer is constructed by applying digital image processing and computer graphic techniques to laser fluorescent motion pictures of its transversal sections. A system of streamwise vortex pairs is shown to exist on top of the classical spanwise eddies. Its influence on mixing is examined.

Jimenez, J.↗

X ray based displacement measurement for hostile environments

A new method on noncontacting, high temperature extensometry based on the focus and scanning of x rays is currently under development and shows great promise of overcoming limitations associated with available techniques. The chief advantage is the ability to make undisturbed measurements through stratified or flowing gases, smoke, and flame. The system is based on the ability to focus and scan low energy, hard x rays such as those emanating from copper or molybdenum sources. The x rays are focused into a narrow and intense line image which can be scanned onto targets that fluoresce secondary x ray radiation. The final goal of the system is the ability to conduct macroscopic strain measurements in hostile environments by utilizing two or more fluorescing targets. Current work is limited to displacement measurement of a single target with a resolution of 1.25 micro-m and a target temperature of 1200 C, directly through an open flame. The main advantage of the technique lies in the penetrating nature of x rays which are not affected by the presence of refracting gas layers, smoke, flame, or intense thermal radiation, all of which could render conventional extensometry methods inoperative or greatly compromise their performance.

Canistraro, Howard A.↗