Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Resonant frequencies of irregularly shaped microstrip antennas using method of moments

This paper describes an application of the method of moments to determine resonant frequencies of irregularly shaped microstrip patches embedded in a grounded dielectric slab. For analysis, the microstrip patch is assumed to be excited by a linearly polarized plane wave that is normal to the patch. The surface-current density that is induced on the patch because of the incident field is expressed in terms of subdomain functions by dividing the patch into identical rectangular subdomains. The amplitudes of the subdomain functions, as a function of frequency, are determined using the electric-field integral equation (EFIE) approach in conjunction with the method of moments. The resonant frequencies of the patch are then obtained by selecting the frequency at which the amplitude of the surface-current density is real. The resonant frequencies of the equilateral triangular and other nonrectangular patches are computed using the present technique, and these frequencies are compared with measurements and other independent calculations.

Deshpande, Manohar D.↗

Dielectric measurements of selected ceramics at microwave frequencies

Dielectric measurements of strontium titanate and lead titanate zirconate ceramics are conducted at microwave frequencies using a cylindrical resonant cavity in the TE(sub 011) mode. The perturbations of the electric field are recorded in terms of the frequency shift and Q-changes of the cavity signal. Slater's perturbation equations are used to calculate e' and e" of the dielectric constant as a function of temperature and frequency.

Dahiya, J. N.↗

Self-Nulling Lock-in Detection Electronics for Capacitance Probe Electrometer

A multi-channel electrometer voltmeter that employs self-nulling lock-in detection electronics in conjunction with a mechanical resonator with noncontact voltage sensing electrodes has been developed for space-based measurement of an Internal Electrostatic Discharge Monitor (IESDM). The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. Use of an AC-coupled lock-in amplifier with closed-loop sense-signal nulling via generation of an active guard-driving feedback voltage provides the resolution, accuracy, linearity and stability needed for long-term space-based measurement of the IESDM. This implementation relies on adjusting the feedback voltage to drive the sense current received from the resonator s variable-capacitance-probe voltage transducer to approximately zero, as limited by the signal-to-noise performance of the loop electronics. The magnitude of the sense current is proportional to the difference between the input voltage being measured and the feedback voltage, which matches the input voltage when the sense current is zero. High signal-to-noise-ratio (SNR) is achieved by synchronous detection of the sense signal using the correlated reference signal derived from the oscillator circuit that drives the mechanical resonator. The magnitude of the feedback voltage, while the loop is in a settled state with essentially zero sense current, is an accurate estimate of the input voltage being measured. This technique has many beneficial attributes including immunity to drift, high linearity, high SNR from synchronous detection of a single-frequency carrier selected to avoid potentially noisy 1/f low-frequency spectrum of the signal-chain electronics, and high accuracy provided through the benefits of a driven shield encasing the capacitance- probe transducer and guarded input triaxial lead-in. Measurements obtained from a 2- channel prototype electrometer have demonstrated good accuracy (|error| < 0.2 V) and high stability. Twenty-four-hour tests have been performed with virtually no drift. Additionally, 5,500 repeated one-second measurements of 100 V input were shown to be approximately normally distributed with a standard deviation of 140 mV.

Blaes, Brent R.↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

Gary A. Sneiderman↗

Dust aerosol retrieval results from MISR (multi-angle imaging spectro-radiometer)

Satellite measurements provide important tools for understanding the effect of mineral dust aerosols on past and present climate and climate predictions. Multi-angle instruments such as Multi-angle Imaging Spectro- Radiometer (MISR) provide independent constraints on aerosol properties based on their sensitivity to the shape of aerosol scattering phase functions. The current MISR operational retrieval algorithm (version 16 and higher) was modified by incorporating new non-spherical dust models that account for naturally occurring dust shapes and compositions. We present selected examples of MISR version 16 retrievals over AERONET sunphotometer land and ocean sites during the passage of dust fronts. Our analysis shows that during such events MISR retrieves Angstrom exponents characteristic of large particles, having little spectral variation in extinction over the MISR wavelength range (442, 550, 672 and 866 nm channels), as expected. The retrieved fraction of non-spherical particles is also very high. This quantity is not retrieved by satellite instruments having only nadir-viewing cameras. Our comparison of current (version 16) MISR-retrieved aerosol optical thickness (AOT) with AERONET instantaneous AOT shows better coverage and stronger correlations than when making identical comparisons with previous AOT retrievals (version 15). The MISR algorithm successful mixtures include a non-spherical dust component with high frequency in retrievals over dark water and slightly lower frequency over land. Selection frequencies of non-spherical dust models also decrease in dusty regions affected by pollution.

Multiangle Imaging Spectroradiometer (MISR)↗

An expert system to analyze high frequency dependent data for the space shuttle main engine turbopumps

The prototype expert system ADDAMX identifies selected sinusoid frequencies from spectral data graphs as speed frequencies and harmonics from each turbopump, frequency feed through from one turbopump to another, frequencies generated by turbopump bearings, pseudo 3N for the phase 2 high pressure fuel turbopump, and electrical noise. ADDAMX does the analysis in an interactive or batch mode and the results can be displayed on the screen or hardcopy.

Garcia, Raul C., Jr.↗

Circuit and Method for Communication Over DC Power Line

A circuit and method for transmitting and receiving on-off-keyed (OOK) signals with fractional signal-to-noise ratios uses available high-temperature silicon- on-insulator (SOI) components to move computational, sensing, and actuation abilities closer to high-temperature or high-ionizing radiation environments such as vehicle engine compartments, deep-hole drilling environments, industrial control and monitoring of processes like smelting, and operations near nuclear reactors and in space. This device allows for the networking of multiple, like nodes to each other and to a central processor. It can do this with nothing more than the already in-situ power wiring of the system. The device s microprocessor allows it to make intelligent decisions within the vehicle operational loop and to effect control outputs to its associated actuators. The figure illustrates how each node converts digital serial data to OOK 18-kHz in transmit mode and vice-versa in receive mode; though operations at lower frequencies or up to a megahertz are within reason using this method and these parts. This innovation s technique modulates a DC power bus with millivolt-level signals through a MOSFET (metal oxide semiconductor field effect transistor) and resistor by OOK. It receives and demodulates this signal from the DC power bus through capacitive coupling at high temperature and in high ionizing radiation environments. The demodulation of the OOK signal is accomplished by using an asynchronous quadrature detection technique realized by a quasi-discrete Fourier transform through use of the quadrature components (0 and 90 phases) of the carrier frequency as generated by the microcontroller and as a function of the selected crystal frequency driving its oscillator. The detected signal is rectified using an absolute-value circuit containing no diodes (diodes being non-operational at high temperatures), and only operational amplifiers. The absolute values of the two phases of the received signal are then summed and hard limited (digitized) by comparing them to a reference level and are then input into a microprocessor as a serial bit stream. The quasi-discrete Fourier transform is performed in high-temperature components (operational amplifiers, analog switches, resistors, and capacitors). The demodulated signal is a serial data stream that is input to the UART (universal asynchronous receiver transmitter) receiver pin of the microprocessor. The OOK of the carrier frequency uses the output of the UART pin as an enabling signal that drives the gate of the MOSFET. Logic low bits enable the carrier frequency (realized by using the 0 phase signal from the microcontroller, though either phase may be used) to be DC-coupled to the power supply bus through a current-limiting resistor mounted between the MOSFET drain and the supply rail. The presence of logic lows on the power supply rail is realized by carrier bursts while logic highs are realized by the absence of bursts.

Krasowski, Michael J.↗

Optimizing a remote sensing instrument to measure atmospheric surface pressure

Atmospheric surface pressure can be remotely sensed from a satellite by an active instrument which measures return echoes from the ocean at frequencies near the 60 GHz oxygen absorption band. The instrument is optimized by selecting its frequencies of operation, transmitter powers and antenna size through a new procedure baesd on numerical simulation which maximizes the retrieval accuracy. The predicted standard deviation error in the retrieved surface pressure is 1 mb. In addition the measurements can be used to retrieve water vapor, cloud liquid water and sea state, which is related to wind speed.

Peckham, G. E.↗

Gamma-ray burst size-frequency distributions - Spectral and temporal selection effects

The effects of spectral variation on the detection of gamma ray bursts were investigated. Selection biases resulting from these effects can account for the reported deviation of the observed size-frequency distribution in peak energy flux from that expected for a simple uniform distribution of sources. Thus these observations as yet provide no clear evidence for structure in the burst source distribution. Because of selection biases, the intrinsic average temperature of the bursts is much harder (kT approximately MeV) than the observed average (approximately 200 keV).

Higdon, J. C.↗

Vibrations of twisted cantilevered plates - Experimental investigation

The experimental portion of a joint government/industry/university research study on the vibrational characteristics of twisted cantilevered plates is presented. The overall purpose of the research study was to assess the capabilities and limitations of existing analytical methods in predicting the vibratory characteristics of twisted plates. Thirty cantilevered plates were precision machined at the Air Force's Aero Propulsion Laboratory. These plates, having five different degrees of twist, two thicknesses, and three aspect ratios representative of turbine engine blade geometries, were tested for their vibration mode shapes and frequencies. The resulting nondimensional frequencies and selected mode shapes are presented as a function of plate tip twist. The trends of the natural frequencies as a function of the governing geometric parameters are discussed. The effect of support compliance on the plate natural frequency and its impact on numerically modeling twisted plates is also presented.

Macbain, J. C.↗

Mars Global Surveyor Ka-Band Frequency Data Analysis

The Mars Global Surveyor (MGS) spacecraft, launched on November 7, 1996, carries an experimental space-to-ground telecommunications link at Ka-band (32 GHz) along with the primary X-band (8.4 GHz) downlink. The signals are simultaneously transmitted from a 1.5-in diameter parabolic high gain antenna (HGA) on MGS and received by a beam-waveguide (BWG) R&D 34-meter antenna located in NASA's Goldstone Deep Space Network (DSN) complex near Barstow, California. The projected 5-dB link advantage of Ka-band relative to X-band was confirmed in previous reports using measurements of MGS signal strength data acquired during the first two years of the link experiment from December 1996 to December 1998. Analysis of X-band and Ka-band frequency data and difference frequency (f(sub x)-f(sub ka)/3.8) data will be presented here. On board the spacecraft, a low-power sample of the X-band downlink from the transponder is upconverted to 32 GHz, the Ka-band frequency, amplified to I-W using a Solid State Power Amplifier, and radiated from the dual X/Ka HGA. The X-band signal is amplified by one of two 25 W TWTAs. An upconverter first downconverts the 8.42 GHz X-band signal to 8 GHz and then multiplies using a X4 multiplier producing the 32 GHz Ka-band frequency. The frequency source selection is performed by an RF switch which can be commanded to select a VCO (Voltage Controlled Oscillator) or USO (Ultra-Stable Oscillator) reference. The Ka-band frequency can be either coherent with the X-band downlink reference or a hybrid combination of the USO and VCO derived frequencies. The data in this study were chosen such that the Ka-band signal is purely coherent with the X-band signal, that is the downconverter is driven by the same frequency source as the X-band downlink). The ground station used to acquire the data is DSS-13, a 34-meter BWG antenna which incorporates a series of mirrors inside beam waveguide tubes which guide the energy to a subterranean pedestal room, providing a stable environment for the feed and electronics equipment. A dichroic plate is used to reflect the X-band energy and pass the Ka-band energy to another mirror. The RF energy for each band is then focused onto a feed horn and low-noise amplifier package. After amplification and RF/IF downconversion, the IF signals are sent to the Experimental Tone Tracker (ETT), a digital phase-lock-loop receiver, which simultaneously tracks both X-band and Ka-band carrier signals. Once a signal is detected, the ETT outputs estimates of the SNR in a I -Hz bandwidth (Pc/No), baseband phase and frequency of the signals every I -sec. Between December 1996 and December 1998, the Ka-band and X-band signals from MGS were tracked on a regular basis using the ETT. The Ka-band downlink frequencies described here were referenced to the spacecraft's on-board USO which was also the X-band frequency reference (f(sub ka)= 3.8 f(sub x)). The ETT estimates of baseband phase at I -second sampled time tags were converted to sky frequency estimates. Frequency residuals were then generated for each band by removing a model frequency from each observable frequency at each time tag. The model included Doppler and other effects derived from spacecraft trajectory files obtained from the MGS Navigation Team. A simple troposphere correction was applied to the data. In addition to residuals, the USO frequencies emitted by the spacecraft were estimated. For several passes, the USO frequencies were determined from X-band data and from Ka-band data (referred to X-band by dividing by 3.8) and were found to be in good agreement. In addition, X-band USO frequency estimates from MGS Radio Science data acquired from operational DSN stations were available for comparison and were found to agree within the I Hz level. The remaining sub-Hertz differences were attributed to the different models and software algorithms used by MGS Radio Science and KaBLE-11. A summary of the results of a linear fit of the USO frequency versus time (day of year) is presented in Table I for an initial segment of passes.

Morabito, D.↗

S-band SBAW microwave source, phase 2

Results of aging experiments on 1.072 GHz SBAW oscillators are discussed as well as the design, fabrication and test of 2.143 GHz SBAW delay lines. Two design approaches were implemented. The third harmonic transducer on 36 deg rotated Y cut quartz proved to be the most useful design, whereas the fifth harmonic transducer on - 50 5 deg rotated Y cut quartz suffered from high insertion loss and poor sidelobe rejection. The construction and characterization of the 2 GHz SBAW oscillator are described. Phase noise, frequency dependence on temperature, and 6-month aging were measured. Some SAW and SBAW oscillators were compared as were both the 1 and 2 GHz oscillators. The 2 GHz SBAW oscillator showed significant improvement in phase noise and temperature stability over the 2 GHz SAW oscillator developed in previous NASA programs. A technique to produce SBAW delay lines of different frequencies from a single mask is examined. The delay lines were incorporated into oscillator circuits to demonstrate the ability to select the frequency output of the SBAW oscillator.

Source record↗

Input-output characterization of an ultrasonic testing system by digital signal analysis

Ultrasonic test system input-output characteristics were investigated by directly coupling the transmitting and receiving transducers face to face without a test specimen. Some of the fundamentals of digital signal processing were summarized. Input and output signals were digitized by using a digital oscilloscope, and the digitized data were processed in a microcomputer by using digital signal-processing techniques. The continuous-time test system was modeled as a discrete-time, linear, shift-invariant system. In estimating the unit-sample response and frequency response of the discrete-time system, it was necessary to use digital filtering to remove low-amplitude noise, which interfered with deconvolution calculations. A digital bandpass filter constructed with the assistance of a Blackman window and a rectangular time window were used. Approximations of the impulse response and the frequency response of the continuous-time test system were obtained by linearly interpolating the defining points of the unit-sample response and the frequency response of the discrete-time system. The test system behaved as a linear-phase bandpass filter in the frequency range 0.6 to 2.3 MHz. These frequencies were selected in accordance with the criterion that they were 6 dB below the maximum peak of the amplitude of the frequency response. The output of the system to various inputs was predicted and the results were compared with the corresponding measurements on the system.

Williams, J. H., Jr.↗

Elastic wave analyzer for icy sub-surfaces (EWAIS) in the solar system

The sub-surface structures of water-bearing icy worlds (e.g., Europa, Enceladus, and Titan) and the structures of icy regions on Mars contain critical information about their origin and evolution. These bodies have been identified as high-priority targets in the NRC Planetary Science Decadal Survey, which noted a lack of technology readiness as one impediment to related missions. An Elastic Wave Analyzer for Icy Sub-surfaces (EWAIS) instrument is being developed to acquire data that can provide answers to fundamental science questions related to these bodies. The EWAIS instrument generates and receives elastic waves using an array of piezoelectric transducers capable of operating at temperatures as low as 30K. A developed breadboard acquires reflected signals from discontinuities in the traveled materials’ impedance (the product of wave velocity and density) along the wave path. Analysis of the acquired data can be used to determine the elastic properties, presence of cracks, locations of cavities and other discontinuities, as well as the thicknesses of ice and liquid layers. The EWAIS instrument is being developed with a novel dual-frequency transmitter array that will enable reaching distances of kilometers through ice, as well as resolving smaller acoustic reflectors nearer the EWAIS instrument. The selected dual frequencies correspond to two depth ranges that can be analyzed, with resolutions of tens of centimeters in the region of tens to hundreds of meters and tens of meters on the kilometers scale, respectively. The EWAIS will be applicable for operation from any in-situ platform, including surface assets (e.g., lander and rover) and sub-surface assets (e.g., melting probes).

Bar-Cohen, Y.↗