Search NASA⌕ Search

SEARCH · Search NASA

Results for “fringe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Interferometric rotation sensor

An interferometric rotation sensor and control system is provided which includes a compound prism interferometer and an associated direction control system. Light entering the interferometer is split into two paths with the light in the respective paths being reflected an unequal number of times, and then being recombined at an exit aperture in phase differing relationships. Incoming light is deviated from the optical axis of the device by an angle, alpha. The angle causes a similar displacement of the two component images at the exit aperture which results in a fringe pattern. Fringe numbers are directly related to angle alpha. Various control systems of the interferometer are given.

Walsh, T. M.↗

Meter-wavelength observations of pulsars using very long baseline interferometry

The results of an investigation of the angular structure imposed on pulsar radiation due to scattering in the interstellar medium are presented. The technique of very-long-baseline interferometry was used to obtain the necessary high angular resolution. The interferometers formed by the Arecibo, NRAO, and Sugar Grove telescopes were used at radio frequencies of 196, 111, and 74 MHz during seven separate observing sessions between November 1971 and February 1973. A crude visibility function for the Crab nebular pulsar was obtained along with the correlated pulse profile. The technique of differential fringe phase was used to show that the pulsar and the compact source in the Crab nebula are coincident to within 0.001 arcsec which corresponds to aproximately 2 a.u. at the distance to the nebula. The ratio of pulsing to total flux, and the fringe visibility of the time-averaged pulsing flux are also discussed, and apparent angular sizes of the pulsars were measured.

Vandenberg, N. R.↗

The structure of radio sources 3C 273B and 3C 84 deduced from the 'closure' phases and visibility amplitudes observed with three-element interferometers

The derived 'closure' phase relation for a three-element interferometer is used in a presented analysis of data obtained from observations at 7.8 GHz of the radio sources 3C 273B and 3C 84 by antennas in Massachusetts, California, Alaska, and Sweden (the first two antennas were used in combination with each of the last two separately to form two three-element interferometers). The brightness distribution is found for each source by expansion of both the fringe amplitude and the fringe phase in separate Fourier series.

Rogers, A. E. E.↗

10-micron heterodyne stellar interferometer

A spatial interferometer for 10-micron wavelength which uses two independent telescopes separated by 5.5 m, heterodyne detection of the infrared radiation, and path equalization by a variable-length RF cable, has given interference fringes from radiation of the planet Mercury. Continuous fringe observations during 4000 sec indicate remarkable stability in the optical-path difference through the atmosphere and the two telescopes, fluctuations between 20-sec averages being about 1/6 of the 10-micron wavelength.

Johnson, M. A.↗

Evaluation of a composite mobile holographic nondestructive test system

A simplified theoretical model for the interpretation of the double-exposure holographic interference fringe loci due to the general three-dimensional displacements was derived for the specific composite mobile holographic nondestructive test system. The model, representing a good approximation to a more tedious theoretical result, predicts that a combination of in-plane and out-of-plane displacements of the surface will produce concentric circular-shaped fringe patterns with locations of their center affected by the displacements. Appropriate experiments were designed and carried out for the test of the validity of the theory. These experiments include the taking of double-exposure holograms of in-plane translations and combined in-plane and out-of-plane translations. The simplified model agreed quite well with the experimental results. Experimentally observed effects due to the curvature of the test plate and the variations of the angles of incidence of the laser light suggest that in order for the simplified model to be able to predict the test results more accurately, incidence and reflection of the laser light should be chosen as nearly perpendicular to the surface of the tested object as possible.

Liu, H. K.↗

On the detection of a cometary mass distribution

The problem of detecting a possible cometary distribution on the fringes of the solar system is examined. The acceleration of a space probe due to a hypothetical cometary mass distribution with the surface density rising to a maximum and subsequently falling off with increasing distance from the sun is analyzed. The total minimum detectable cometary mass for the Pioneer and Mariner spacecraft is estimated on the basis of this model to be on the order of 1000 earth masses. Precision tracking of deep space probes is less sensitive by three orders of magnitude for the detection of an unseen cometary mass distribution at the fringes of the solar system than are the secular perturbations of long-period comets.

Boss, A. P.↗

Limitations on the use of laser velocimeter signals for particle sizing

The paper discusses the complex relationship existing between the diameter of a particle, its index of refraction, and the output signal of a fringe-type laser velocimeter, and describes a special purpose laser velocimeter for aerosol sizing that determines aerosol size distributions on the basis of Farmer's (1973) relationship between visibility and particle size. In experiments with particles of known size, this relationship is in qualitative agreement with the experimentally observed results, the main differences being that (1) the visibility does not assume a minimum value of zero, as predicted, and (2) the visibility value above which there is no ambiguity in the corresponding fringe spacing is higher than that predicted.

Orloff, K. L.↗

Delay compensation - Its effect in reducing sampling errors in Fourier spectroscopy

An approximate formula is derived for the spectrum ghosts caused by periodic drive speed variations in a Michelson interferometer. The solution represents the case of fringe-controlled sampling and is applicable when the reference fringes are delayed to compensate for the delay introduced by the electrical filter in the signal channel. Numerical results are worked out for several common low-pass filters. It is shown that the maximum relative ghost amplitude over the range of frequencies corresponding to the lower half of the filter band is typically 20 times smaller than the relative zero-to-peak velocity error, when delayed sampling is used. In the lowest quarter of the filter band it is more than 100 times smaller than the relative velocity error. These values are ten and forty times smaller, respectively, than they would be without delay compensation if the filter is a 6-pole Butterworth.

Zachor, A. S.↗

The sensitivity of a very long baseline interferometer

The theoretical sensitivity of various methods of acquiring and processing interferometer data are compared. It is shown that for a fixed digital recording capacity one bit quantization of single sideband data filtered with a rectangular bandpass and sampled at the Nyquist rate yields the optimum signal to noise ratio. The losses which result from imperfect bandpass, poor image rejection, approximate methods of fringe rotation, fractional bit correction, and loss of quadrature are discussed. Also discussed is the use of the complex delay function as a maximum likelihood fringe estimator.

Rogers, A. E. E.↗

Thermal expansion of composites using Moire interferometry

An experimental technique for precise measurement of the thermal response of fiber-reinforced composite materials uses moire interferometry with fringe multiplication which yield a sensitivity of 833 nm (32.8 mu in.) per fringe. Results from the technique are compared with those obtained from electrical resistance strain gages, and also those predicted from classical lamination theory. Temperature dependent coefficients of thermal expansion for composite materials subjected to thermal cycling in the temperature range of 297 K (75 F) to 422 K (300 F) were determined for four laminate configurations (0, 90, 0/ + or - 45/90 sub s and 0/90/ + or - 45 sub s) of T300/5208 graphite epoxy, and ranged from -0.107 mu epsilon K/1 (-0.059 mu epsilon deg F/-) for the 0 laminate to 32.18 mu epsilon K/1 (17.88 mu epsilon F/1) for the 90 laminate. Moisture was found to greatly influence the thermal response of a quasi-isotropic laminate, resulting in hysteresis and residual compressive strain as the moisture content was reduced. Comparisons between moire and strain gage measurements were inconclusive with both techniques giving consistent but systematically different results. Differences of as much as 29% were observed.

Bowles, D. E.↗

Holographic flow visualization at NASA Langley

Holographic flow visualization systems at two NASA Langley facilities, a hypersonic blow-down tunnel using CF4 gas and an expansion tube with very short test time, are described. A pulsed ruby laser is used at a CF4 tunnel for single pulse holography, double pulse with several minutes between exposures, and dual plate holographic interferometry. Shadowgraph, schlieren, and interferograms are reconstructed from the holograms in a separate reconstruction lab. At the expansion tube the short run time of 200 microseconds requires precise triggering of its double pulsed ruby laser. With double pulse capability of 20 to 1200 microseconds pulse separation, one pulse can occur before and one later after flow is established to obtain fringe free background interferograms (perfect infinite fringe) or both pulses can occur during flow in order to study flow instabilities. Holograms are reconstructed at the expansion tube with an in-place setup which makes use of a high power CW Argon laser and common optics for both recording and reconstructing the holograms. The holographic systems at the CF4 tunnel and expansion tube are operated routinely for flow visualization by tunnel technicians. Typical flow visualization photographs from both facilities are presented.

Burner, A. W.↗

Intermode calibration of diode-laser spectra using tandem etalons

The paper deals with an approach which can improve the accuracy of etalon calibration of tunable diode-laser (TDL) spectra in the IR and extend absolute calibration among several isolated modes. Two etalons placed in the laser beam produce a combined fringe pattern that, with the aid of a monochromator mode selector, can be used to establish the number of fringes between any two spectral points separated by a large frequency interval. This technique has been applied to several similar cases for calibration of isolated modes or verification of the identity of lines of known frequency.

Jennings, D. E.↗

Measurement of the specific refractivities of CF4 and C2F6

In order to relate the measured fringe shift of an interferometer to the density of a medium, the relation between density and refractive index, which is expressed by the specific refractivity, must be known. In the present paper, the specific refractivities of the wind tunnel test gases CF4 and C2F6 are determined in order to verify estimations based on the atomic refractivities of carbon and fluorine. A Twyman-Green two-beam interferometer with a 633-nm He-Ne laser light source was used to measure the specific refractivity as a function of fringe shift as the density of the gas was changed. Values of 0.122 and 0.131 cu cm/g were obtained for CF4 and C2F6 respectively at a temperature of 300 K, which are within 1% of the values computed from the atomic refractivities.

Burner, A. W.↗

Interferometer Accurately Measures Rotation Angle

Interference fringes from superimposed beams move across a photodetector, creating electrical pulses. Frequency of pulses is direct measure of angular velocity of rotating body. If separation of the sources changes, it affects separation of all fringes equally and does not affect angular velocity measurement.

Minott, P. O.↗

VLBI observations of SS 433 at 3.6 and 13 centimeters

SS 433 was detected and partially resolved at 2290 MHz on baselines with fringe spacings of 1.4, 0.1, and 0.003 arcsec. It was also detected at 8420 MHz on a baseline with a fringe spacing of 0.009 arcsec. Simple models of the source, consistent with the limited data, have elongated structures greater than 0.1 arcsec in size with position angles in 1979 May that were within about 10 deg of the position angle of the apparent bulges of the supernova remnant W50. The data also imply that the source contains a core less than 0.002 arcsec in size with a brightness temperature greater than 10 to the 9th K. The bright core and aligned structures that seem to be present in SS 433 and W50 resemble the structures seen in powerful extragalactic radio sources which are many orders of magnitude larger.

Walker, R. C.↗

Very high resolution observations of SS433 at 10.65 GHz

Observations of SS433 made on June 12, 1979, from West Germany, Massachusetts, and West Virginia are discussed. It is noted that SS433 did not show fringes on any baseline although all the calibration sources were seen at their expected strengths. The measured total flux density of SS433 was found to be approximately 0.5 Jy, consistent with previous observations. The source was observed by on-offs at each telescope, which indicates that they were all pointed properly during the observations. The absence of fringes is not attributed to poor observing conditions or instrumental difficulties. It is concluded that if all the 10.65 GHz radiation emanates from a single component, then that component is at least 0.005 arcsec (approximately 10 to the 14th cm) in size. The measurements made on more sensitive intercontinental baselines indicate that there is no component of SS433 smaller than 0.001 arcsec emitting 10.65 GHz radiation above a level of 50 mJy.

Geldzahler, B. J.↗

Alignment of a two-beam interferometer

Two beam interferometers have been proposed for space applications such as sensing the shape of a large antenna. Since alignment and adjustment of interferometers have long been considered difficult laboratory tasks, the question of making their operation sufficiently automatic for space applications is a serious one. As a first step in addressing this question certain manual procedures, which may not be well known, have been collected from widely scattered sources. These techniques are illustrated by two examples: (1) the alignment of a Mach-Zehnder interferometer and the adjustment of fringe location. (2) The adjustment of a Michelson interferometer for zero path difference (white light fringes).

Tubbs, E. F.↗

Dynamic Moire Methods for Detection of Loosened Space Shuttle Tiles

Moire fringe methods for detecting loose space shuttle tiles were investigated with a test panel consisting of a loose tile surrounded by four securely bonded tiles. The test panel was excited from 20 to 150 Hz with in-plane sinusoidal acceleration of 2 g (peak). If the shuttle orbiter can be subjected to periodic excitation of 1 to 2 g (peak) and rigid-body periodic displacements do not mask the change in the Moire pattern due to tile looseness, then the use of projected Moire fringes to detect out-of-plane rockin appears to be the most viable indicator of tile looseness since no modifications to the tiles are required.

Snow, W. L.↗