Search NASA⌕ Search

SEARCH · Search NASA

Results for “gas detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Nature of the carbon and sulfur phases and inorganic gases in the Kenna ureilite

Abundances of carbon and sulfur in the Kenna ureilite are 2.219 plus or minus 0.060 wt. % C and 0.179 plus or minus 0.008 wt. % S. Secondary carbonates resulting from terrestrial weathering account for 0.25 plus or minus 0.02 wt. % C. No hydrocarbons were detected during gas release measurements. Most of the carbon is in graphite, diamond, or lonsdaleite. The sample of Kenna contained 0.95 plus or minus 0.05 wt.% H2O. Total carbon and sulfur measurements were made on three additional ureilites: Havero, Dingo Pup Donga, and North Haig. Ureilite carbon abundances are similar to those of C-2 chondrites, whereas sulfur abundances are a factor of 10 less than C-2 chondrites and ordinary chondrites. The elemental abundances, ratios, and phases present in the ureilites rule out a direct genetic relationship between the ureilites and the carbonaceous chondrites.

Gibson, E. K., Jr.↗

Observations of long-period Cepheids between l = 294 and 331 deg

Photoelectric and spectroscopic observations of long-period Cepheids, as well as 21-cm profiles in the directions of these young stars, are presented for the Crux-Centaurus-Circinus-Norma section of the Milky Way. The UBV data have been used to revise periods and light-curve parameters and ultimately to calculate the distances of these stars. From the spectroscopic information velocity estimates have been made. Finally, the stellar velocities have been compared with H I gas motions detected along the same line of sight. These results are briefly discussed with a view to understanding the spiral structure of the region.

Grayzeck, E. J.↗

Apparatus for sensor failure detection and correction in a gas turbine engine control system

A gas turbine engine control system maintains a selected level of engine performance despite the failure or abnormal operation of one or more engine parameter sensors. The control system employs a continuously updated engine model which simulates engine performance and generates signals representing real time estimates of the engine parameter sensor signals. The estimate signals are transmitted to a control computational unit which utilizes them in lieu of the actual engine parameter sensor signals to control the operation of the engine. The estimate signals are also compared with the corresponding actual engine parameter sensor signals and the resulting difference signals are utilized to update the engine model. If a particular difference signal exceeds specific tolerance limits, the difference signal is inhibited from updating the model and a sensor failure indication is provided to the engine operator.

Spang, H. A., III↗

On the global distribution of Pluto's atmosphere

The present investigation is relevant to the study of Pluto's current global and diurnal radiation balance. Strong gravitational tides are suggested by Charon's close proximity to Pluto (approximately 20,000 km) and Charon's large relative mass (roughly 0.25 Pluto's mass). Thus, the Pluto-Charon system replaces the earth-moon system as the best known example of a double planet. Methane is the only gas positively detected in Pluto's atmosphere. The tendency of the whole atmosphere to bulge preferentially toward the subsolar point as a result of the solar heating of the suface is considered, taking into account the longitudinal and the latitudinal tide. It is concluded that near perihelion, Pluto's atmosphere is essentially uniform over Pluto's surface. Its heat capacity by virtue of the heat of condensation is large enough that eclipses and the diurnal variation of insolation cause negligible freezing out of atmospheric gases.

Trafton, L.↗

Thermal Infrared Observations of Lava Flows During the 1984 Mauna Loa Eruption

Thermal infrared videotape images of the flowing lava streams and the vent areas at 10.6 microns were made, as well as some broadband images in the 8 to 12 micron range (for gas plume detection). These data were calibrated with on-site hand-held radiometer measurements, in-flow thermocouple measurements, and with later laboratory kiln measurements. Infrared video data are useful in quantitatively assessing the pattern and mode of flow thermal losses, particularly with regard to radiative losses from established/incipient floating crust. The general cooling of the flows downstream was readily apparent. Upper reaches of the active flow exhibited nearly crust-free main channels, radiating at about 700 to 800 degrees C. Below about the 7500 foot level (about 8 km from the vent) the flows formed nearly continuous crust and tended to spread, become less well-defined and founder due to a reduction in slope. Nevertheless, in thermal IR observations, the surface trace of the active subsurface channel was visible, radiating at about 500 to 700 degrees C. At the active flow front, most solid crust radiated at temperatures less than 500 to 600 degrees C, however bright high temperature interiors (approximately 900 to 1000 degrees C) were clearly visible though evolving fissures.

Pieri, D. C.↗

Free radicals in the stratosphere - A new observational technique

A new approach to in situ observations of trace reactive species in the stratosphere is described. A balloon-borne system, floating 40 kilometers above the earth's surface, successfully lowered and then retracted a cluster of instruments a distance of 12 kilometers on a filament of Kevlar. This instrument cluster is capable of detecting gas-phase free radicals at the part-per-trillion level. The suspended instrument array has excellent stability and has been used to measured atomic oxygen concentrations in the stratosphere.

Anderson, J. G.↗

Solid-Sorbent Air Sampler

Portable unit takes eight 24-hour samples. Volatile organic compounds in air collected for analysis by portable, self-contained sampling apparatus. Sampled air drawn through sorbent material, commercial porous polymer of 2, 3-diphenyl-p-phenylene oxide. High-boiling-point organic compounds adsorbed onto polymer, while low-boiling-point organics pass through and returned to atmosphere. Sampler includes eight sample tubes filled with polymeric sorbent. Organic compounds in atmosphere absorbed when air pumped through sorbent. Designed for checking air in spacecraft, sampler adaptable to other applications as leak detection, gas-mixture analysis, and ambient-air monitoring.

Galen, T. J.↗

Observations of 1.3 millimeter continuum emission from the centers of galaxies

A search for 1.3 mm continuum emission from the centers of eight galaxies has been conducted, and three sources of emission, all apparently arising from cold dust, have been detected. The gas mass associated with this dust is calculated. A rough correlation found between the J = 1-0 CO emission and the millimeter continuum flux, as well as a fair agreement between the masses determined from the two types of observation, support the view that the cool dust is mixed with the molecular material in the program objects. Atomic hydrogen masses estimated for the same cources from 21 cm line observations show that there is little H I in the objects. Most of the objects form stars at about the same efficiency as does the Galaxy.

Thronson, Harley A., Jr.↗

PG 1411 + 442 - The nearest broad absorption line quasar

IUE observations reveal strong, moderately broad absorption troughs in the blue wings of the C IV and N V emission lines of the quasar PG 1411 + 442. No absorption from weakly ionized gas is detected. The emission-line strengths and overall shape of the ultraviolet/optical/near-infrared/far-infrared continuum of the new broad absorption line quasar are within the range normally measured in quasars. Its redshift is low enough to allow the morphology of the host galaxy to be studied in deep broad-band and intermediate-band CCD images. The galaxy appears to be a large spiral with a very long arm or tail. The inclination angle is 57 deg, which rules out the possibility that the line of sight to the nucleus intersects a large path length in a galactic disk.

Malkan, Matthew A.↗

A bound on X-ray emission from the intrasupercluster medium

The Bahcall-Soneira (1984) complete sample of superclusters was searched for X-ray emission in the HEAO 1 A-2 data base. No statistically significant emission from diffuse intrasupercluster gas was detected; a 3-sigma upper limit to the mean individual flux is 10 to the -11th ergs/sq cm per s. Implications of this bound to measurements of the Zeldovich-Sunyaev (1969) effect toward clusters within a supercluster and to the supercluster contribution to the cosmic X-ray background are discussed.

Persic, Massimo↗

Micromachined electron tunneling infrared sensors

The development of an improved Golay cell is reported. This new sensor is constructed entirely from micromachined silicon components. A silicon oxynitride (SiO(x)N(y)) membrane is deflected by the thermal expansion of a small volume of trapped gas. To detect the motion of the membrane, an electron tunneling transducer is used. This sensor detects electrons which tunnel through the classically forbidden barrier between a tip and a surface; the electron current is exponentially dependent on the separation between the tip and the surface. The sensitivity of tunneling transducers constructed was typically better than 10(exp -3) A/square root of Hz. Through use of the electron tunneling transducer, the scaling laws which have prevented the miniaturization of the Golay cell are avoided. This detector potentially offers low cost fabrication, compatibility with silicon readout electronics, and operation without cooling. Most importantly, this detector may offer better sensitivity than any other uncooled infrared sensor, with the exception of the original Golay cell.

Kenny, T. W.↗

The use of ion mobility spectrometry and gas chromatography/mass spectrometry for the detection of illicit drugs on clandestine records

Illicit drug distribution has over the past decade grown tremendously from simple 'drug pushing' where drugs were distributed from poorly organized individuals to today's well organized and well financed drug cartels. This change to a more 'corporate-like' atmosphere has resulted in a greater use of record keeping to monitor the profits generated. The use of record keeping by drug distributors is not restricted to high level drug smugglers but is used at all levels within the distribution network. Dealers at all levels including street dealers are generally 'fronted', given on consignment quantities of drugs that they in turn sell to customers, thereby requiring the need for records to keep track of drug sales versus liabilities. These records because of their illicit nature are often encrypted to hide the fact that they are indeed records of drug transactions. The creation of a handwritten notation concerning a drug transaction is normally brought on because of a purchase or sale. In a sale, this is commonly accomplished through a consignment, or the designation of a quantity to a customer to whom that amount has been 'fronted'. Because this activity generates a debt, it follows that an accounting for payments made, as well as new transactions completed, is only logical. One of the most common means of representing these is through an 'accounting flow', in which payments are subtracted from a running balance while new sales are added to it. The examination of illicit drug records has been the key to the prosecution of numerous federal, state, and local drug cases for a number of years. The Document Section of the FBI Laboratory, through its Racketeering Records Analysis Unit (RRAU), has been involved in such analytical efforts since 1983. Detailed analytical research brought about an evolution in the systematic approach utilized in the RRAU since that time. The close proximity of the drugs to the records often results in trace drug evidence being transferred to the records. The detection of trace drug residue on surfaces by ion mobility spectrometry (IMS) is well documented in literature. The following procedure will deal primarily with the newer techniques of trace drug analysis and drug record analysis developed by the Chemistry/Toxicology Unit of the FBI Laboratory since the more traditional techniques of latent finger print analysis and document analysis are well known.

Donnelly, Brian↗

GHRS observations of mass-loaded flows in Abell 78

Spectroscopic observations of the central star of the planetary nebula Abell 78 were obtained with the Goddard High Resolution Spectrograph (GHRS) onboard the Hubble Space Telescope (HST) in the vicinity of the C IV lambda 1548.2, 1550.8 doublet. We find a series of narrow absorption features superposed on the broad, P Cygni stellar wind profile. These features are seen in both components of the doublet at heliocentric radial velocities of -18, -71, -131, and -192 km/s. At higher velocities, individual components are no longer distinct but, rather, merge into a continuous absorption extending to approximately -385 km/s. This is among the highest velocities ever detected for gas in a planetary nebula. The -18 km/s feature originates in an outer envelope of normal composition, while the -71 km/s feature is produced in the wind-swept shell encircling an irregular wind-blown bubble in the planetary nebula center. The hydrogen-poor ejecta of Abell 78, consisting of dense knots with wind-blown tails, are located in the bubble's interior, in the vicinity of the stellar wind termination shock. The high-velocity C IV lambda 154 absorption features can be explained as due to parcels of ejecta being accelerated to high velocities as they are swept up by the stellar wind during its interaction with dense condensations of H-poor ejecta. As the ablated material is accelerated, it will partially mix with the stellar wind, creating a mass-loaded flow. The abundance anomalies seen at the rim of the bubble attest to the transport of H-poor knot material by such a flow.

Harrington, J. Patrick↗

Preimpact characterization of Comet P/Shoemaker-Levy 9

At McDonald Observatory, we have undertaken a major program of observation of Comet P/Shoemaker-Levy 9 in order to charcterize the dynamics and physical make-up of the fragments prior to their disappearance in July 1994 when they collide with Jupiter. Obserations have included astrometry, photometry, and spectroscopy. Our astrometric observations have been important for deriving accurate orbits for the individual fragments. With the photometry, we have derived (B-V) and (V-R) colors for a number of fragemnts. We show that they are slightly redder than the Sun in (B-V) and similar to the Sun in (V-R); they may show differences in colors for the individual fragments. We detected no gas with our spectroscopic observations and have derived sensitive upper limits on the quantity of gas. Our observations are consistent with the parent being a comet, as classified, but cannot rule out certain types of asteroids as progenitors.

Cochran, Anita L.↗

Length of stain dosimeter

Payload customers for the Space Shuttle have recently expressed concerns about the possibility of their payloads at an adjacent pad being contaminated by plume effluents from a shuttle at an active pad as they await launch on an inactive pad. As part of a study to satisfy such concerns a ring of inexpensive dosimeters was deployed around the active pad at the inter-pad distance. However, following a launch, dosimeters cannot be read for several hours after the exposure. As a consequence factors such as different substrates, solvent systems, and possible volatilization of HCl from the badges were studied. This observation led to the length of stain (LOS) dosimeters of this invention. Commercial passive LOS dosimeters are sensitive only to the extent of being capable of sensing 2 ppm to 20 ppm if the exposure is 8 hours. To map and quantitate the HCl generated by Shuttle launches, and in the atmosphere within a radius of 1.5 miles from the active pad, a sensitivity of 2 ppm HCl in the atmospheric gases on an exposure of 5 minutes is required. A passive length of stain dosimeter has been developed having a sensitivity rendering it capable of detecting a gas in a concentration as low as 2 ppm on an exposure of five minutes.

Lueck, Dale E.↗

Selective Catalytic Combustion Sensors for Reactive Organic Analysis

Sensors involving a vanadia-alumina catalyst bed-thermocouple assembly satisfy requirements for simple, reproducible and rapid continuous analysis or reactive organics. Responses generally increase with temperature to 400 C and increase to a maximum with flow rate/catalyst volume. Selectivity decreases with temperature. Response time decreases with flow rate and increases with catalyst volume. At chosen optimum conditions calculated response which is additive and linear agrees better with photochemical reactivity than other methods for various automotive sources, and response to vehicle exhaust is insensitive to flow rate. Application to measurement of total reactive organics in vehicle exhaust as well as for gas chromatography detection illustrate utility. The approach appears generally applicable to high thermal effect reactions involving first order kinetics.

Innes, W. B.↗

A Study of H II Regions and M8

We present an overview of the objects in the interstellar medium known as H II regions. These clouds of dust and gas are detected in emission throughout the plane of the galaxy, and are the site of ongoing star formation. We present imagery of one of the more famous H II regions; M8, the Lagoon Nebula. The ionization structure of the nebula is examined and our ground-based imagery is compared to HST (Hubble Space Telescope) archival images of this object.

Battle, Tamara↗

Gas Analyzer

A miniature gas chromatograph, a system which separates a gaseous mixture into its components and measures the concentration of the individual gases, was designed for the Viking Lander. The technology was further developed under National Institute for Occupational Safety and Health (NIOSH) and funded by Ames Research Center/Stanford as a toxic gas leak detection device. Three researchers on the project later formed Microsensor Technology, Inc. to commercialize the product. It is a battery-powered system consisting of a sensing wand connected to a computerized analyzer. Marketed as the Michromonitor 500, it has a wide range of applications.

Source record↗