Search NASA⌕ Search

SEARCH · Search NASA

Results for “grating array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Highly cascaded first-order sapphire optical fiber Bragg gratings fabricated by a femtosecond laser

This Letter reports an innovative technique for fabricating large-scale, highly cascaded first-order sapphire optical fiber Bragg gratings (FBGs) using a femtosecond laser-assisted point-by-point inscription method. For the first time, to the best of our knowledge, this study successfully demonstrates a distributed array of 10 FBGs within highly multimode sapphire crystal fiber, made possible by employing a high-power laser technique to generate larger reflectors with a Gaussian intensity profile. These first-order FBGs offer advantages such as enhanced reflectivity, shorter fabrication time, and simplified spectral characteristics, making them easier to interpret compared with high-order FBGs. The FBGs’ resilience and effectiveness are analyzed by subjecting them to temperature tests, proving their capacity for accurate temperature monitoring up to 1500°C—a testament to their suitability for harsh environments. This novel approach broadens the scope for sensing and communication applications in sapphire fibers, particularly under challenging conditions. The novelty of our work lies in successfully overcoming the limitations of previous designs by integrating a cascade of 10 FBGs in sapphire fibers, thereby enhancing multiplexing capabilities, minimizing overlapping of FBG peaks, and ensuring reliable temperature monitoring in industries and applications with thermal gradients.

47 OTHER INSTRUMENTATION↗

Plasmonic Antenna Coupling for QWIPs

In a proposed scheme for coupling light into a quantum-well infrared photodetector (QWIP), an antenna or an array of antennas made of a suitable metal would be fabricated on the face of what would otherwise be a standard QWIP. This or any such coupling scheme is required to effect polarization conversion: Light incident perpendicularly to the face is necessarily polarized in the plane of the face, whereas, as a matter of fundamental electrodynamics and related quantum selection rules, light must have a non-zero component of perpendicular polarization in order to be absorbed in the photodetection process. In a prior coupling scheme, gratings in the form of surface corrugations diffract normally gles, thereby imparting some perpendicular polarization. Unfortunately, the corrugation- fabrication process increases the overall nonuniformity of a large QWIP array. The proposed scheme is an alternative to the use of surface corrugations.

Hong, John↗

640 x 512 Pixels Long-Wavelength Infrared (LWIR) Quantum-Dot Infrared Photodetector (QDIP) Imaging Focal Plane Array

Epitaxially grown self-assembled. InAs-InGaAs-GaAs quantum dots (QDs) are exploited for the development of large-format long-wavelength infrared focal plane arrays (FPAs). The dot-in-a-well (DWELL) structures were experimentally shown to absorb both 45 degrees and normal incident light, therefore, a reflection grating structure was used to enhance the quantum efficiency. The devices exhibit peak responsivity out to 8.1 micrometers, with peak detectivity reaching approximately 1 X 10(exp 10) Jones at 77 K. The devices were fabricated into the first long-wavelength 640 x 512 pixel QD infrared photodetector imaging FPA, which has produced excellent infrared imagery with noise equivalent temperature difference of 40 mK at 60-K operating temperature.

quantum dots (QDs)↗

Designs for scalable construction of hybrid quantum photonic cavities

Nanophotonic resonators are central to numerous applications, from efficient spin–photon interfaces to laser oscillators and precision sensing. A leading approach consists of photonic crystal (PhC) cavities, which have been realized in a wide range of dielectric materials. However, translating proof-of-concept devices into a functional system entails a number of additional challenges, inspiring new approaches that combine resonators with wavelength-scale confinement and high quality factors; scalable integration with integrated circuits and photonic circuits; electrical or mechanical cavity tuning; and, in many cases, a need for heterogeneous integration with functional materials such as III–V semiconductors or diamond color centers for spin–photon interfaces. Here we introduce a concept that generates a finely tunable PhC cavity at a selected wavelength between two heterogeneous optical materials whose properties satisfy the above requirements. The cavity is formed by stamping a hard-to-process material with simple waveguide geometries on top of an easy-to-process material consisting of dielectric grating mirrors and active tuning capability. We simulate our concept for the particularly challenging design problem of multiplexed quantum repeaters based on arrays of cavity-coupled diamond color centers, achieving theoretically calculated unloaded quality factors of 106, mode volumes as small as 1.2(λ/neff)3, and maintaining >60% total on-chip collection efficiency of fluorescent photons. We further introduce a method of low-power piezoelectric tuning of these hybrid diamond cavities, simulating optical resonance shifts up to ∼760 GHz and color center fluorescence tuning of 5 GHz independent of cavity tuning. These results will motivate integrated photonic cavities toward larger scale systems-compatible designs.

Greenspon, Andrew S. (ORCID:0000000296317568)↗

Advanced Fiber-optic Monitoring System for Space-flight Applications

Researchers at Luna Innovations Inc. and the National Aeronautic and Space Administration s Marshall Space Flight Center (NASA MSFC) have developed an integrated fiber-optic sensor system for real-time monitoring of chemical contaminants and whole-cell bacterial pathogens in water. The system integrates interferometric and evanescent-wave optical fiber-based sensing methodologies with atomic force microscopy (AFM) and long-period grating (LPG) technology to provide versatile measurement capability for both micro- and nano-scale analytes. Sensors can be multiplexed in an array format and embedded in a totally self-contained laboratory card for use with an automated microfluidics platform.

Hull, M. S.↗

The Infrared Spectrograph on the Spitzer Space Telescope

The Infrared Spectrograph (IRS) instrument on the Spitzer Space Telescope covered the 5 to 38 micron wavelength range at low and medium spectral resolutions. The instrument was very popular during Spitzer’s 5.7 year-long cold mission. Every year it attracted the most proposals, and garnered more observing hours, of any of the science instruments. This success was the culmination of a very long development period, where the instrument design changed radically. When the instrument was first selected by NASA in 1984 it was very complicated. As part of the overall reduction of the size of the SIRTF Observatory following its recovery from the mission’s cancellation in 1991 the IRS became smaller and much, much simpler. The only aspect of the instrument that increased from the original design was the pixel count of the detectors. The new, lean, IRS based on eight axioms: (1) SIRTF is a cost-driven mission; (2) Only Boeing Si:As and Si:Sb 128x128 BIB arrays shall be used; (3) The IRS has all Aluminum housing and optics; (4) Simple optics consisting of surfaces of revolution, flat gratings, and “bolt-and-go” tolerances; (5) No moving parts; (6) Redundancy only for credible single-point failures; (7) Strive for an observing efficiency of 80%; (8) The IRS shall be capable of internal health assessment. This led to a simple, robust, but still extremely powerful final instrument composed of four distinct modules. Many of the features developed for the IRS were subsequently employed in other spacecraft and SOFIA science instrumentation. This presentation will cover the developmental history of the IRS instrument, its final design and performance, and will especially highlight the sage decisions that Jim Houck made along the way that led to its highly successful career on the Spitzer Space Telescope.

Roellig, Thomas L.↗

CARBO - The Carbon Observatory Instrument Suite - The Next Generation of Earth Observing Instruments for Global Monitoring of Carbon Gases

The Carbon Observatory Instrument Suite, or CARBO, consists of four carbon observing instruments sharing a common instrument bus, yet targeted for a particular wavelength band each with a unique science observation. They are: a) Instrument 1, wavelength centered at 756 nm for oxygen and solar-induced chlorophyll fluorescence (SIF) observations, b) Instrument 2, centered at 1629 nm, for carbon dioxide (CO2) and methane (CH4) observation, c) Instrument 3, centered at 2062 nm for carbon dioxide and d) Instrument 4, centered at 2328 for carbon monoxide (CO) and methane. From low-Earth orbit, these instruments have a field-of-view of 10 to 15 degrees, and a spatial resolution of 2 km square. These instruments have a spectral resolving power ranging from ten to twenty thousand, and can monitor columnaverage dry air mole fraction of carbon dioxide (XCO2) at 1.5 ppm, and methane (XCH4) at 7 ppb. These new instruments will advance the use of immersion grating technology in spectrometer instruments in order to reduce the size of the instrument, while improving performance. These compact, capable instruments are envisioned to be compatible with small satellites, yet modular to be configured to address the particular science questions at hand. Here we report on the current status of the instrument design and fabrication, focusing primarily on Instruments 1 and 2. We will describe the key science and engineering requirements and the instrument performance error budget. We will discuss the optical design with particular emphasis on the immersion grating, and the advantages this new technology affords compared to previous instruments. We will also discuss the status of the focal plane array and the detector electronics and housing. Finally, we report on a new approach – developed during this instrument design process - which enables simultaneous measurement of both orthogonal polarization states (S and P) over the field-of-view and optical bandpass. We believe this polarization sensing capability will enable science observations which were previously limited by instrumental and observational degeneracies. In particular: improved sensitivity to all species, better sensitivity to surface polarization effects, better constraints on aerosol scattering parameters, and superior discrimination of the vertical distribution of gases and aerosols.

Bernas, Michael↗

15 cut-off 128x128 Quantum Well Infrared Photodetectors (QWIPS) Camera

We discuss the development and the performance of a very long wavelength (13.5 - 15 128x128 AlGaAs/GaAs multiquantum well infrared imaging system. Highly uniform, high-yield QWIP focal plane array was hybridized to a CMOS multiplexer operating in a direct injection mode. For efficient light coupling an integral random scattering reflector (Random Grating) was incorporated. Due to the high uniformity, excellent imagery, low noise as well as a noise equivalent temperature difference (NE T) of less than 30 mK were obtained when operating around 45 K. Therefore, high image contrast signal to noise ratio has been achieved.

128x128 Photodetectors↗

Imaging IR spectrometer, phase 2

The development is examined of a prototype multi-channel infrared imaging spectrometer. The design, construction and preliminary performance is described. This instrument is intended for use with JPL Table Mountain telescope as well as the 88 inch UH telescope on Mauna Kea. The instrument is capable of sampling simultaneously the spectral region of 0.9 to 2.6 um at an average spectral resolution of 1 percent using a cooled (77 K) optical bench, a concave holographic grating and a special order sorting filter to allow the acquisition of the full spectral range on a 128 x 128 HgCdTe infrared detector array. The field of view of the spectrometer is 0.5 arcsec/pixel in mapping mode and designed to be 5 arcsec/pixel in spot mode. The innovative optical design has resulted in a small, transportable spectrometer, capable of remote operation. Commercial applications of this spectrometer design include remote sensing from both space and aircraft platforms as well as groundbased astronomical observations.

Gradie, Jonathan↗

Design and implementation of a portable diagnostic system for Thomson scattering and optical emission spectroscopy measurements

A diagnostic system, which has a design goal of high-portability, has been designed at Oak Ridge National Laboratory (ORNL). This project aims at providing measurements of key plasma parameters (ne, Te, ni, Ti) for fusion-relevant devices, utilizing Thomson scattering (TS) and optical emission spectroscopy (OES). The innovative design employs mostly commercial off-the-shelf instrumentation and a traveling team of researchers to conduct measurements at various magnetic-confinement plasma devices. The TS diagnostic uses a Quantel Q-smart 1500 Nd:YAG laser with a 2ω harmonic generator to produce up to 850 mJ of 532 nm laser pulses at 10 Hz. Collection optics placed at the detection port consists of an 11 × 3 optical fiber bundle, where the TS diagnostic uses an 11 × 1 subset array of the fibers, the OES diagnostic uses another 11 fibers, and the remaining fibers are available to the host institution. The detection system is comprised of two separate IsoPlane-320 spectrometers with triple-grating turrets of various line spacing and two PI-MAX 4 intensified CCD detectors, used simultaneously to measure a broad range of ion, impurity, and electron parameters. The self-contained diagnostic package also includes a data processing and storage system. The design and initial implementation of the TS-OES diagnostic system are described. The experiments from the proof-of-principle operation of the portable package on a high density (∼2.5 × 1022 m−3) and low-temperature (∼5 eV) electrothermal arc source at ORNL are also discussed.

Kafle, N. (ORCID:000000028144787X)↗

Rotary encoding device using polygonal mirror with diffraction gratings on each facet

A device for position encoding of a rotating shaft in which a polygonal mirror having a number of facets is mounted to the shaft and a monochromatic light beam is directed towards the facets. The facets of the polygonal mirror each have a low line density diffraction grating to diffract the monochromatic light beam into a number of diffracted light beams such that a number of light spots are created on a linear array detector. An analog-to-digital converter is connected to the linear array detector for reading the position of the spots on the linear array detector means. A microprocessor with memory is connected to the analog-to-digital converter to hold and manipulate the data provided by the analog-to-digital converter on the position of the spots and to compute the position of the shaft based upon the data from the analog-to-digital converter.

Leviton, Douglas B.↗

High Angular Sensitivity, Absolute Rotary Encoding Device with Polygonal Mirror and Stand-Alone Diffraction Gratings

A device for position encoding of a rotating shaft in which a polygonal mirror having a number of facets is mounted to the shaft and a monochromatic light beam is directed towards the facets. The facets of the polygonal mirror direct the light beam to a stand-alone low line density diffraction grating to diffract the monochromatic light beam into a number of diffracted light beams such that a number of light spots are created on a linear array detector. An analog-to-digital converter is connected to the linear array detector for reading the position of the spots on the linear array detector means. A microprocessor with memory is connected to the analog-to-digital converter to hold and manipulate the data provided by the analog-to-digital converter on the position of the spots and to compute the position of the shaft based upon the data from the analog-lo-digital converter.

Leviton, Douglas B.↗

X-ray spectrograph design

An aberration theory is applied to spectrograph design. The initial system considered has a toroidal mirror in front of a concave grating spectrograph, giving spatial resolution perpendicular to the dispersion direction. The accuracy of the theory is shown by comparison of spot diagrams obtained from the aberrations with those produced by raytracing. The major aberrations affecting the vignetting at the intermediate slit and the spatial resolution are identified. A new system, using a holographic grating to give a flat focal plane, is then designed and optimized. It has increased spatial resolution over the wavelength range and is particularly suitable for microchannel array detectors.

Chrisp, M. P.↗

Solar energy converter using surface plasma waves

Sunlight is dispersed over a diffraction grating formed on the surface of a conducting film on a substrate. The angular dispersion controls the effective grating period so that a matching spectrum of surface plasmons is excited for parallel processing on the conducting film. The resulting surface plasmons carry energy to an array of inelastic tunnel diodes. This solar energy converter does not require different materials for each frequency band, and sunlight is directly converted to electricity in an efficient manner by extracting more energy from the more energetic photons.

Anderson, L. M.↗

A faint object spectrometer for the infrared

A cryogenic astronomical spectrometer for the NASA Infrared Telescope Facility is described. This spectrometer will employ an array of at least 20 detectors and provide a resolving power of 100 to 1500 at 1-5 microns. The resolving power will be adjustable by changing gratings.

Tokunaga, A. T.↗

Ultra-Sensitive Transition-Edge Sensors for the Background Limited Infrared/Sub-mm Spectrograph (BLISS)

We report progress in fabricating ultra-sensitive superconducting transition-edge sensors (TESs) for BLISS. BLISS is a suite of grating spectrometers covering 35-433 micron with R approx. 700 cooled to 50 mK that is proposed to fly on the Japanese space telescope SPICA. The detector arrays for BLISS are TES bolometers readout with a time domain SQUID multiplexer. The required noise equivalent power (NEP) for BLISS is NEP = 10(exp -19) W/Hz(exp 1/2) with an ultimate goal of NEP= 5 x 10(exp -20) W/Hz(exp 1/2) to achieve background limited noise performance. The required and goal response times are tau = 150 ms and tau = 50ms respectively to achieve the NEP at the required and goal optical chop frequency 1-5 Hz. We measured prototype BLISS arrays and have achieved NEP = 6 x 10(exp -18) W/Hz(exp 1/2) and tau = 1.4 ms with a Ti TES (T(sub C) = 565 mK) and NEP approx. 2.5 x 10(exp -19) W/Hz(exp 1/2) and tau approximates 4.5 ms with an Ir TES (T(sub C) = 130 mK). Dark power for these tests is estimated at 1-5 fW.

transition-edge sensors (TESs)↗

A 1-D Submm-wave Leaky-Wave Phased Array using MEMS Phase Shifters

Beam-scanning of submillimeter-wave spectrometers and radiometers have traditionally been implemented using mechanical scanning mechanisms due to the absence of lowloss electronic phase shifters. Recently developed waveguideintegrated MEMS phase shifters are paving the way to realize electronic beam-steering using submm-wave phased arrays. In this work, two phased array demonstrators are presented that operate from 500GHz to 600GHz. A 20 dB directivity 8 ? 1 leaky-wave antenna array will be demonstrated, using fixed waveguide feeding networks, to be capable of ?20? scanning with a scan loss less than 1:7 dB. Secondly, an equivalent but smaller 17 dB directivity 4 ? 1 array will be integrated with MEMS phase shifters to demonstrate a dynamic scanning capability over a ?9:5? range. The antenna array is based on closely sampled square waveguides, terminated with a double-iris, in close proximity of a low permittivity superstrate in order to reduce the grating lobes at larger scanning angles. Measurements are expected to be presented at the conference.

Chattopadhyay, Goutam↗

Ka-Band Phased Array System Characterization

Phased Array Antennas (PAAs) using patch-radiating elements are projected to transmit data at rates several orders of magnitude higher than currently offered with reflector-based systems. However, there are a number of potential sources of degradation in the Bit Error Rate (BER) performance of the communications link that are unique to PAA-based links. Short spacing of radiating elements can induce mutual coupling between radiating elements, long spacing can induce grating lobes, modulo 2 pi phase errors can add to Inter Symbol Interference (ISI), phase shifters and power divider network introduce losses into the system. This paper describes efforts underway to test and evaluate the effects of the performance degrading features of phased-array antennas when used in a high data rate modulation link. The tests and evaluations described here uncover the interaction between the electrical characteristics of a PAA and the BER performance of a communication link.

Acosta, R.↗