Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid current controller”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Equivalent-Circuit Models of Grid-Forming IBRs for Electromagnetic-Transient Simulations: Preprint

We derive equivalent-circuit models of control- and physical-layer subsystems of grid-forming (GFM) inverter-based resources (IBRs) for electromagnetic-transient (EMT) simulations. Three different primary controllers are considered: droop, virtual synchronous machine (VSM), and dispatchable virtual oscillator control (dVOC). In addition, the models include cascaded voltage- and current-control loops, and LCL output filters. Simulations for a single-inverter setup and for a network of five inverters in a modified IEEE 14-bus topology are presented. The equivalent-circuit models simulated with analog electronic circuit-simulator software (in our case, LTspice) offer the same accuracy with up to 150x lower computational burden compared to block-diagram-based implementations in commercial off-the-shelf EMT software (in our case, MATLAB-Simulink).

circuit-equivalent model↗

Equivalent-Circuit Models of Grid-Forming IBRs for Electromagnetic-Transient Simulations

We derive equivalent-circuit models of control- and physical-layer subsystems of grid-forming (GFM) inverter-based resources (IBRs) for electromagnetic-transient (EMT) simulations. Three different primary controllers are considered: Droop, Virtual Synchronous Machine (VSM), and dispatchable Virtual Oscillator Control (dVOC). In addition, the models include cascaded voltage- and current-control loops, and LCL output filters. Simulations for a single-inverter setup and for a network of five inverters in a modified IEEE 14-bus topology are presented. The equivalent-circuit models simulated with analog electronic circuit-simulator software (in our case, LTspice) offer the same accuracy, and with no explicit tuning of the solver, lower computational burden compared to block-diagram-based implementations in commercial off-the-shelf EMT software (in our case, MATLAB-Simulink).

electromagnetic transient simulation↗

Caldera Infrastructure Charge Module (ICM)

Caldera ICM is part of Caldera software platform, a suite of collective, open-source tools that was developed to improve the state of the art in modeling the impacts of Electric Vehicle (EV) charging on the grid. The foundation of Caldera ICM is it’s first-of-its-kind library of high-fidelity charging models for a wide variety of vehicles, validated by test data under a range of operating conditions. The charging models are used to accurately model the EV charging on an electric vehicle supply equipment (EVSE) – also known as a charger. ICM uses as inputs, the EV characteristics such as battery size, battery chemistry (i.e. NMC, LTO), watt hour per mile, inverter efficiency and max charge rate; as well as EVSE characteristics such as max current and supply equipment type (i.e. L2 vs XFC). Using these inputs Caldera ICM creates an uncontrolled charging profile curve for each compatible EV-EVSE pair. These charge profiles can be used stand alone to estimate charge duration given start State Of Charge (SOC) and end SOC or charge energy size given start SOC and charge duration. In Caldera Grid, another tool in the Caldera software platform, these charge profiles are used to represent EV charging as a load on the grid using charge event data such as EV type, SE type, start SOC, final SOC, park start time and park end time. ICM currently supports energy shifting Smart Charge Management (SCM) strategies such as "Time Of Use (TOU) immediate”, “TOU random” and “random start” by delaying the charge to start at a preferable time with respect to the strategy and, one voltage support SCM strategy named autonomous voltage control strategy by providing reactive power back to the electric grid.

Sundarrajan, ManojKumar Cebol↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Review of Quantum Computing Technologies in Power System Optimization

As modern power grids increasingly integrate variable renewable generation, distributed energy resources, and energy storage systems, classical optimization techniques are facing unprecedented challenges. This review examines the emerging application of quantum computing to overcome these challenges in power system optimization, including optimal power flow (OPF), unit commitment (UC), economic dispatch (ED), and intelligent switching and topology optimization (IS-TO). Recent research has introduced various quantum methodologies—such as gate-based, annealing-based, variational algorithms, and quantum-inspired algorithms—to address the combinatorial complexity inherent in grid reconfiguration and energy management. The review summaries the quantum algorithms, quantum devices and the power system test cases, highlighting hybrid quantum–classical strategies that leverage the complementary strengths of both paradigms. Some quantum advantages have been observed, including theoretical speedup, accurate simulation results, scalable qubit usage, efficient QUBO mapping. In particular, the review emphasizes the importance of integrating quantum optimization techniques with classical control frameworks, these hybrid approaches demonstrate the potential to improve real-time grid management and operational reliability. A significant portion of the analysis is devoted to the practical limitations of current quantum devices. Present-day quantum hardware, operating in the noisy intermediate-scale quantum (NISQ) era, remains highly sensitive to noise and limited in qubit connectivity, which constrains the scale and accuracy of implemented algorithms. The review delves into specific challenges such as the need for qubit-efficient encoding techniques and error mitigation strategies that are critical for handling real-world grid optimization problems. In addition, the work draws attention to the performance discrepancies between theoretical quantum speedups and experimental validations, underscoring the importance of rigorous benchmark studies using representative power grid test cases. In summary, this review highlights both the promise and limitations of quantum computing for power system optimization. It provides a comprehensive overview of the state-of-the-art technologies, categorizes recent advancements in algorithm design, and discusses practical considerations for implementation, and serves as an informative resource on current research. Future research directions include developing robust hybrid frameworks, advancing qubit-efficient formulations, and scaling up experimental demonstrations to confirm the theoretical advantages of quantum methods in large-scale power system operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Environmental Flow Requirements from FERC Licenses Across the US

Environmental flow requirements included in Federal Energy Regulatory Commission (FERC) hydropower licenses are important for balancing natural properties and benefits of river ecosystems (e.g., healthy species, recreation, water supply, flood control) supporting hydropower production. In some cases, environmental flow requirements may limit operational flexibility given current operational schemes and make a hydropower plant less able to provide power to the electric grid on demand. Hydropower plants may gain some flexibility as hydropower scheduling time periods are made to be more responsive to the short-term needs of an energy grid increasingly reliant on intermittent renewables. However, many flow requirements focus on the daily, monthly, or seasonal flow fluctuations which matches the time scale of most paradigms linking flow alterations to the health of river ecosystems. This dataset seeks to provide a greater understanding of how flexibility in environmental requirements can be leveraged to create positive outcomes for both the power system and the environment. It contains information on environmental flow requirements from the Protection, Mitigation, and Enhancement section of 50 randomly selected FERC licenses: 25 issued from 1998-2013 that were also included in the ORNL Mitigation Database (Schramm et al. 2015) and 25 issued from 2014-present. The information on environmental flow requirements was extracted from the PM&E section of 50 randomly selected FERC licenses: 25 issued from 1998-2013 that were also included in the ORNL Mitigation Database (Schramm et al. 2015) and 25 issued from 2014-present. The flow requirements were then categorized into flow augmentation categories based on whether the license stated a specific water management purpose for the given requirement called augmentation categories (i.e., fisheries or habitat, recreation or boating, industry, and general or unspecified; Table B). Requirements were also grouped into flow type categories (e.g., minimum flow rate, maximum flow rate, ramping rate). Additional information related to flow requirements such as the augmentation time-period and whether the flow rate was continuous (i.e., condition must be present at all-times) or instantaneous (i.e., condition present at a point in time) was also extracted from the licenses. Some licenses had specific flow requirements based on whether the project was in a wet, dry, or normal water year. If that information was presented in the license, it was also included in the data set. The location within the project was noted, hereafter, zone, in the dataset for flow requirements relating to specific areas of hydropower projects (Dam, Powerhouse, Bypass Reach). Maximum discharge capacities of hydropower facilities were also extracted from both the Existing Hydropower Assets (EHA) data set and the National Inventory of Dams (NID) databases. Each facility was coded with project identification codes from the EHA dataset to facilitate cross-referencing between datasets.

13 HYDRO ENERGY↗

DOE LeRC photovoltaic systems test facility

The facility was designed and built and is being operated as a national facility to serve the needs of the entire DOE National Photovoltaic Program. The object of the facility is to provide a place where photovoltaic systems may be assembled and electrically configured, without specific physical configuration, for operation and testing to evaluate their performance and characteristics. The facility as a breadboard system allows investigation of operational characteristics and checkout of components, subsystems and systems before they are mounted in field experiments or demonstrations. The facility as currently configured consist of 10 kW of solar arrays built from modules, two inverter test stations, a battery storage system, interface with local load and the utility grid, and instrumentation and control necessary to make a flexible operating facility. Expansion to 30 kW is planned for 1978. Test results and operating experience are summaried to show the variety of work that can be done with this facility.

Cull, R. C.↗

Adaptive Computing and Multi-Fidelity Strategies for Control, Design and Scale-Up of Renewable Energy Applications

We describe our ongoing research in adaptive computing and multi-fidelity modeling strategies. Our goal is to use a combination of low- and high-fidelity simulation models to enable computationally efficient optimization and uncertainty quantification. We develop optimization formulations that take into account the compute resources currently available, which act as a constraint with regards to the fidelity level simulation we can run while maximizing information gain. These strategies are being implemented into a software framework with a generalized API allowing its application to a broad range of applications, from power grid stability and buildings control to material synthesis and biofuels processing. We will discuss a few examples from these applications that can benefit from this approach, especially when considering challenges arising in scaling up experiments and simulations.

adaptive computing↗

Functional Assessment of Shell Recharge Solutions' SKY™ Platform OpenADR Capability

The project’s overall objective is to research, develop, and conduct a wide-scale demonstration of a utility smart charge management (SCM) system to develop optimal managed charging structures for grid value, evaluate the impact of EV charging on local distribution utility operations, and evaluate the utilities’ ability to control electronic vehicle (EV) charging load based on grid conditions. This report covers Argonne’s validation testing in the first period of the project, the objective of which was to determine the current managed charging functionality of the EVSE hardware, the network and the vehicle telematics software solution and understand gaps that need to be addressed prior to a large-scale demonstration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing Synchronous Condenser Operation of Hydrogenerators

Hydropower plants are sometimes dispatched below capacity or even shut down to meet water regulations. These can temporarily be repurposed to operate as synchronous condensers. To enable this capability, this paper proposes a design that allows hydrogenerators to safely operate as synchronous condensers, providing fast voltage and reactive power support under both normal and boost conditions. The proposed design integrates capability curves with hydrogenerators’ excitation systems through modifications using proposed MVA-field current curve, current controller, and limiter. The design is implemented locally at the machine for rapid response. Simulation results demonstrate the effectiveness of the proposed design and using hydrogenerators as synchronous condensers in power grids.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Cyber–physical vulnerability and resiliency analysis for DER integration: A review, challenges and research needs

High penetration of renewable and sustainable Distributed Energy Resources (DER) into the traditional distribution system requires a well-coordinated control strategy for the improvement of system-wide reliability and resiliency. Implementation of such a holistic control architecture requires a flexible, near real-time, and bi-directional communication framework for facilitating the participation of various agents in a multi-vendor heterogeneous smart grid. While the sustainability of energy generation is ensured, this exposes the smart grid to extrinsic cyber threats, and appropriate defense mechanism(s) must be deployed to guarantee continued reliability and resiliency of the power grid. Further, the comprehensive literature review presented in this paper discusses the latest trends in the DER control schemes with fast communication requirements and their accompanying cyber–physical vulnerabilities. These control schemes are compared and contrasted for various traits. A three-level DER system architecture has been depicted, facilitating the deployment of these control schemes. The current developments of standard communication protocols, key security mechanisms, and best practices along major standards and guidelines are explored. The impacts of different attack types with miscellaneous DER functions based on various control schemes and associated mitigation solutions are also provided. Finally, challenges and future research directions for limiting cyber-power susceptibility to enhance resiliency are summarized. The work presented here will help us enabling a cyber-resilient and sustainable smart electric grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hardware-In-the-Loop Benchmarking Setup for Phasor Based Control Validation

Phasor Based Control is a novel approach to controlling Distributed Energy Resources that aims at relieving various constraints that arise in the distribution grid. It is a two-layer control system with a supervisory control that coordinates distributed controllers to reach voltage phasor targets. The distributed controllers use local synchrophasor measurements and operate as feedback controllers. This control method is currently under development with several algorithms being under consideration for both the central and distributed components. In this report, we present the experimental setup that was prepared to prototype a hardware implementation and validate the control method in Hardware-In-the-Loop.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hardware-In-the-Loop Benchmarking Setup for Phasor Based Control Validation

Phasor Based Control is a novel approach to controlling Distributed Energy Resources that aims at relieving various constraints that arise in the distribution grid. It is a two-layer control system with a supervisory control that coordinates distributed controllers to reach voltage phasor targets. The distributed controllers use local synchrophasor measurements and operate as feedback controllers. This control method is currently under development with several algorithms being under consideration for both the central and ditributed components. In this paper, we present the experimental setup that was prepared to prototype a hardware implementation and validate the control method in Hardware-In-the-Loop.

Baudette, Maxime↗

The DE-AC accelerator system for high beam current density

A radically different ion accelerator system design has been developed to increase the extracted beam current density of ion thrusters. By independently controlling plasma ion extraction and acceleration, the Decoupled Extraction and Amplified Current (DE-AC) accelerator system gives higher beam currents at lower electric field stress levels. Results are presented for DE-AC grid system operation with the Test Bed Ion Engine. Using argon propellant, feasibility of a 60 mA/sq cm beam current density is shown. A discussion of power supply requirements, specific impulse operation and grid system geometrical design is presented also.

Aston, G.↗

Overview of TRMM Data Products and Services

November 27, 2007 marks the l0th anniversary of the launch of the Tropical Rainfall Measuring Mission (TRMM) satellite. In anticipation of this anniversary, this paper will present an overview of the various TRMM data products currently available including the standard products, near real-time products, special products, and prototype products. It also will present an easy way to obtain these data. TRMM standard products have been publicly available since a few months after launch in November 1997. TRMM is currently on version 6 of the data product. Version 3 was the "at launch" version. The approval for each of these versions came through the Joint TRMM Science Team. Standard products are divided into 3 categories: single TRMM instrument, Visible Infrared Scanner (VIRS), TRMM Microwave Imager (TMI), and Precipitation Radar (PR); combined TRMM products (PR and TMI); finally TRMM and other satellites (combined, TMI, SSMI, AMSRE, AMSU). The single TRMM instrument products are processed through 4 levels: Level lA, science data packets processed into orbital files; Level 1B and lC, geolocated data at the instrument field of view; Level 2, geolocated, geophysical parameters at the instrument field of view; Level 3, time aggregated, gridded geophysical parameters. These products are available with 24 hours of production through an anonymous ftp account on trmmopen.gsfc.nasa.gov. The TRMM data system started to produce near real-time products at the end of 1999. They are currently available only through a controlled user account. However, approval to get access to this account can be obtained by sending a note to Erich.F.Stoclter@nasa.gov providing the reason for access and contact information including a valid email. TRMM is not restricting access but needs the information to determine the usefulness of near-real time data to the general science community including applications agencies. TRMM near real-time products are swath products up to Level 2 of processing. The oldest data in the swath is generally no older than 120 minutes when it becomes available to the community. The real-time products including a VIRS level lB, a TMI parameter reduced 1B, a TMI level 2 parameter reduced rain product, a PR level 2 surface rain product, and a PR level 2 rain product with 25 vertical levels. Currently, TRMM also produces a gridded 3 hour global merged product from several radiometers including AMSU and from radiometercalibrated IR data. The paper also describes several simple-format gridded text products available fiom the trmmopen.gsfc.nasa.gov anonymous fip server denoted as 3668 products. These products were produced to provide rain estimates from the three TRMM instruments in a universal format (ASCII) that requires very little data format knowledge. The paper goes on to describe prototype L1 radiometer products that apply an early intercalibration approach that provides a starting point to be used for Global Precipitation Measurement mission radiometer products. The paper also provides a brief overview of a precipitation features data product being produced using TRMM products including the Lighting Imaging Sensor (LIS) using an algorithm developed at the University of Utah and distributed by that organization. The paper concludes with some possible changes to products that are planned for the next reprocessing cycle and special services such as geographical subsetting available to the science community.

Stocker, Erich Franz↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

Providing Ancillary Services with Photovoltaic Generation in Multi- Timescale Grid Operation

With penetration levels of photovoltaic (PV) generation substantially increasing, electric power systems need more flexible resources that can provide ancillary services to mitigate the variability and uncertainty of the PV. On one hand, the increase in PV generation necessitates more flexible resources; on the other hand, because of its low operation cost, PV generation has been replacing conventional generation, which is currently the main flexible resource. Consequently, there is a trend to require renewable generation, including PV, to provide flexible ancillary services. This paper proposes a multi-timescale grid operation model considering the various control strategies of PV providing different ancillary services. Numerical case studies demonstrate that with PV providing both regulation reserve and primary frequency reserve, the system operating costs and PV curtailment will be reduced significantly. Results show that not only the system reliability can be improved but also PV profitability with PV providing more ancillary services.

41 EE - Solar Energy Technologies Office (EE-4S)↗