Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Effects of Phasor Measurement Uncertainty on Power Line Outage Detection

Phasor measurement unit (PMU) technology provides an effective tool to enhance the wide-area monitoring systems (WAMSs) in power grids. Although extensive studies have been conducted to develop several PMU applications in power systems (e.g., state estimation, oscillation detection and control, voltage stability analysis, and line outage detection), the uncertainty aspects of PMUs have not been adequately investigated. This paper focuses on quantifying the impact of PMU uncertainty on power line outage detection and identification, in which a limited number of PMUs installed at a subset of buses are utilized to detect and identify the line outage events. Specifically, the line outage detection problem is formulated as a multi-hypothesis test, and a general Bayesian criterion is used for the detection procedure, in which the PMU uncertainty is analytically characterized. We further apply the minimum detection error criterion for the multi-hypothesis test and derive the expected detection error probability in terms of PMU uncertainty. The framework proposed provides fundamental guidance for quantifying the effects of PMU uncertainty on power line outage detection. Case studies are provided to validate our analysis and show how PMU uncertainty influences power line outage detection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of GPS Signal Loss and Its Mitigation in Power System Synchronized Measurement Devices

With the aid of global positioning system (GPS), synchronized measurement devices (SMDs) are increasingly deployed across power systems to monitor the status of electric grids by providing accurate measurement data along with unified time stamps. Unfortunately, GPS receivers tend to lose signal lock when certain uncontrollable and unpredictable factors arise. In order to investigate the presence of GPS signal loss (GSL) issues on measurement devices, analysis is performed on historical data from both phasor data concentrators and FNET/GridEye servers. Meanwhile, the impact of GSL on field measurement accuracy has not been previously explored in depth. Through analysis and experimental tests, this paper discovers angle drift caused by GSL, which consequently leads to the total vector error exceeding the IEEE standard C37.118.1-2011. Furthermore, a compensation method is proposed to rectify the angle drift and laboratory experiments demonstrate that the proposed method does effectively reduce angle drift and mitigate the impact of GSL in SMDs.

47 OTHER INSTRUMENTATION↗

Structure Learning and Statistical Estimation in Distribution Networks - Part II

Limited placement of real-time monitoring devices in the distribution grid, recent trends notwithstanding, has prevented the easy implementation of demand-response and other smart grid applications. Part I of this paper discusses the problem of learning the operational structure of the grid from nodal voltage measurements. In this work (Part II), the learning of the operational radial structure is coupled with the problem of estimating nodal consumption statistics and inferring the line parameters in the grid. Based on a Linear-Coupled(LC) approximation of AC power flows equations, polynomial time algorithms are designed to identify the structure and estimate nodal load characteristics and/or line parameters in the grid using the available nodal voltage measurements. Then the structure learning algorithm is extended to cases with missing data, where available observations are limited to a fraction of the grid nodes. The efficacy of the presented algorithms are demonstrated through simulations on several distribution test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Statistical Profiles of E1 EMP Coupling to Single Conductors

An electro-magnetic pulse (EMP) event can induce large currents and voltages on electrical conductors such as electrical power transmission lines which span many kilometers and the shorter lines typically tens of meters in length used to monitor equipment controlling the power grid. The exact current and voltage induced on a conductor depends on many factors, such as line height, diameter and length as well as ground conductivity and the location of the EMP event relative to the conductor. The current work focus on the line location and orientation relative to the EMP source. A statistical, Monte-Carlo approach is used in sampling the line configuration and then calculating the induced current and voltage. Thousands of EMP events are simulated on the region of the Earth where the EMP event can couple to a given above-ground conductor and the resulting current and voltage is then calculated on that conductor. Through the many simulations, one can assemble statistics on the insult including the peak value, rise time and pulse width.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Formal Verification of Safety Properties for Aerospace Systems Through Algorithms Based on Exhaustive State-Space Exploration

The Runway Safety Monitor (RSM) designed by Lockheed Martin is part of NASA's effort to reduce aviation accidents. We developed a Petri net model of the RSM protocol and used the model checking functions of our tool SMART to investigate a number of safety properties in RSM. To mitigate the impact of state-space explosion, we built a highly discretized model of the system, obtained by partitioning the monitored runway zone into a grid of smaller volumes and by considering scenarios involving only two aircraft. The model also assumes that there are no communication failures, such as bad input from radar or lack of incoming data, thus it relies on a consistent view of reality by all participants. In spite of these simplifications, we were able to expose potential problems in the RSM conceptual design. Our findings were forwarded to the design engineers, who undertook corrective action. Additionally, the results stress the efficiency attained by the new model checking algorithms implemented in SMART, and demonstrate their applicability to real-world systems. Attempts to verify RSM with NuSMV and SPIN have failed due to excessive memory consumption.

Ciardo, Gianfranco↗

Formal Verification of the Runway Safety Monitor

The Runway Safety Monitor (RSM) designed by Lockheed Martin is part of NASA's effort to reduce runway accidents. We developed a Petri net model of the RSM protocol and used the model checking functions of our tool SMART to investigate a number of safety properties in RSM. To mitigate the impact of state-space explosion, we built a highly discretized model of the system, obtained by partitioning the monitored runway zone into a grid of smaller volumes and by considering scenarios involving only two aircraft. The model also assumes that there are no communication failures, such as bad input from radar or lack of incoming data, thus it relies on a consistent view of reality by all participants. In spite of these simplifications, we were able to expose potential problems in the RSM conceptual design. Our findings were forwarded to the design engineers, who undertook corrective action. Additionally, the results stress the efficiency attained by the new model checking algorithms implemented in SMART, and demonstrate their applicability to real-world systems.

Siminiceanu, Radu↗

Evidence Based Medicine in Space Flight: Evaluation of Inflight Vision Data for Operational Decision-Making

Due to recently identified vision changes associated with space flight, JSC Space and Clinical Operations (SCO) implemented broad mission‐related vision testing starting in 2009. Optical Coherence Tomography (OCT), 3 Tesla Brain and Orbit MRIs, Optical Biometry were implemented terrestrially for clinical monitoring. While no inflight vision testing was in place, already available onorbit technology was leveraged to facilitate in‐flight clinical monitoring, including visual acuity, Amsler grid, tonometry, and ultrasonography. In 2013, on‐orbit testing capabilities were expanded to include contrast sensitivity testing and OCT. As these additional testing capabilities have been added, resource prioritization, particularly crew time, is under evaluation.

Van Baalen, Mary↗

Accounting for the Effects of Surface BRDF on Satellite Cloud and Trace-Gas Retrievals: A New Approach Based on Geometry-Dependent Lambertian-Equivalent Reflectivity Applied to OMI Algorithms

Most satellite nadir ultraviolet and visible cloud, aerosol, and trace-gas algorithms make use of climatological surface reflectivity databases. For example, cloud and NO2 retrievals for the Ozone Monitoring Instrument (OMI) use monthly gridded surface reflectivity climatologies that do not depend upon the observation geometry. In reality, reflection of incoming direct and diffuse solar light from land or ocean surfaces is sensitive to the sun-sensor geometry. This dependence is described by the bidirectional reflectance distribution function (BRDF). To account for the BRDF, we propose to use a new concept of geometry-dependent Lambertian equivalent reflectivity (LER). Implementation within the existing OMI cloud and NO2 retrieval infrastructure requires changes only to the input surface reflectivity database. The geometry-dependent LER is calculated using a vector radiative transfer model with high spatial resolution BRDF information from the Moderate Resolution Imaging Spectroradiometer (MODIS) over land and the Cox-Munk slope distribution over ocean with a contribution from water-leaving radiance. We compare the geometry-dependent and climatological LERs for two wavelengths, 354 and 466 nm, that are used in OMI cloud algorithms to derive cloud fractions. A detailed comparison of the cloud fractions and pressures derived with climatological and geometry-dependent LERs is carried out. Geometry-dependent LER and corresponding retrieved cloud products are then used as inputs to our OMI NO2 algorithm. We find that replacing the climatological OMI-based LERs with geometry-dependent LERs can increase NO2 vertical columns by up to 50% in highly polluted areas; the differences include both BRDF effects and biases between the MODIS and OMI-based surface reflectance data sets. Only minor changes to NO2 columns (within 5 %) are found over unpolluted and overcast areas.

Lambert-equivalent reflectivity↗

A High-Fidelity Electromagnetic Transient Model of Inverter-based Resources Integrated to an IEEE-9 Bus System for Benchmarking Studies

An inverter-based resource (IBR) is a source of electricity that is asynchronously connected to the electrical grid via an electronic power converter. These power sources lack the intrinsic behaviors of the standard power plants, presenting specific challenges to system stability. These power sources lack the intrinsic behaviors of the standards power plants and their features are almost entirely defined by the control strategy used on them, presenting specific challenges to system stability as their penetration increases into the already fragile Bulk Power System (BPS). Utilizing renewable energy has a great upside but the electrical industry needs to understand the requirements like performing electromagnetic transient (EMT) simulation studies in planning and/or in interconnection studies. This paper presents the development of a high-fidelity EMT model based on commercial equipment and field parameters, which at the same time aims to study the increasing penetration of IBRs and their impact on the actual BPS. The open-source EMT model developed will be a benchmarking example that can be used to evaluate algorithms in the power grid (including evaluating grid-forming controls, power system monitoring and operation, etc.).

Martinez Montejano, Misael↗

Distribution Transformer Health Monitoring using Smart Meter Data

The distribution electric grid has become a highly complex and intelligent network with changing load and customer types. This has generated unprecedented challenges and opportunities for utility companies–opportunities especially in the area of asset health/performance management. Moreover, several utilities are increasingly moving from the traditional reactive and time-based asset monitoring approach to a more proactive condition based method. However, this needs to be done in a low-cost and efficient manner. Here, this paper explores how existing sensor infrastructure such as smart meters can be utilized to provide utility operators with more visibility into the health and operation of their assets. The paper focuses primarily on service transformers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Grid Gap Measurement for an NSTAR Ion Thruster

The change in gap between the screen and accelerator grids of an engineering model NSTAR ion optics assembly was measured during thruster operation with beam extraction. The molybdenum ion optics assembly was mounted onto an engineering model NSTAR ion thruster. The measurement technique consisted of measuring the difference in height of an alumina pin relative to the downstream accelerator grid surface. The alumina pin was mechanically attached to the center aperture of the screen grid and protruded through the center aperture of the accelerator grid. The change in pin height was monitored using a long distance microscope coupled to a digital imaging system. Transient and steady-state hot grid gaps were measured at three power levels: 0.5, 1.5 and 2.3 kW. Also, the change in grid gap was measured during the transition between power levels, and during the startup with high voltage applied just prior to discharge ignition. Performance measurements, such as perveance, electron backstreaming limit and screen grid ion transparency, were also made to confirm that this ion optics assembly performed similarly to past testing. Results are compared to a prior test of 30 cm titanium ion optics.

Diaz, Esther M.↗

A Framework for Counterfeit Smart Grid Device Detection

The core vision of the smart grid concept is the realization of reliable two-­way communications between smart devices (e.g., IEDs, PLCs, PMUs). The benefits of the smart grid also come with tremendous security risks and new challenges in protecting the smart grid systems from cyber threats. Particularly, the use of untrusted counterfeit smart grid devices represents a real problem. Consequences of propagating false or malicious data, as well as stealing valuable user or smart grid state information from counterfeit devices are costly. Hence, early detection of counterfeit devices is critical for protecting smart grid’s components and users. To address these concerns, in this poster, we introduce our initial design of a configurable framework that utilize system call tracing, library interposition, and statistical techniques for monitoring and detection of counterfeit smart grid devices. In our framework, we consider six different counterfeit device scenarios with different smart grid devices and adversarial seZings. Our initial results on a realistic testbed utilizing actual smart-­grid GOOSE messages with IEC-­61850 communication protocol are very promising. Our framework is showing excellent rates on detection of smart grid counterfeit devices from impostors.

97 MATHEMATICS AND COMPUTING↗

Towards Non-Intrusive Real-Time Monitoring of Behind the Meter Residential Distributed Energy Resources

The growing adoption of residential distributed energy resources (DERs) introduces more uncertain variability in power grid operation. More importantly, the residential DERs operate behind customers’ energy meters, and therefore, the utility cannot “directly” monitor them. Prior approaches to enable visibility into behind-the-meter (BTM) DERs either depend on estimations or require intrusive instrumentation on the customer side. To address the critical need for direct real-time monitoring of BTM DERs, in this paper, we propose a novel approach for utility-side direct real-time monitoring of residential BTM DERs. We utilize high-frequency (> 10kHz) conducted electromagnetic interference (EMI) from residential DERs’ grid-tied inverters to monitor their power generation. We discuss the working principle of our approach and present supporting results using three of-the-shelf grid-tied inverters.

14 SOLAR ENERGY↗

Behind-the-Meter Solar Generation Disaggregation using Consumer Mixture Models

To facilitate deep penetration of solar energy in smart grids, we need high observability of solar generation at the edges of the grid. Current advanced metering infrastructures (AMI) only monitor the aggregated measurements from net-metered households, but disaggregated consumption and solar generation components are required for grid optimizations. We propose an unsupervised disaggregation model for disaggregating solar generation from AMI measurements without the need of training data. The model requires only AMI measurements from consumers in a region and the solar irradiance as input, and models the consumption of consumers by neighboring households without rooftop photovoltaics (PV) to perform the disaggregation. We evaluate our results on a real life dataset from Austin, Texas. We show that our model is able to disaggregate consumption and solar generation measurements with 42.24% and 31.67% less mean squared error, respectively, in comparison to a baseline technique that uses supervised learning. This shows that our model is capable of disaggregating historical data even if the dataset has no training data and only contains minimal exogenous data.

14 SOLAR ENERGY↗

Measurement Adequacy for Monitoring Data Center Oscillations

Artificial intelligence (AI) training data centers with periodic load profiles can induce sustained grid oscillations across a wide frequency range, making accurate monitoring essential for reliable power system operation. This report evaluates the adequacy of existing measurement systems for monitoring such oscillations, focusing on phasor measurement units (PMUs) and point-on-wave (POW) measurement systems. The analysis shows that while PMUs are highly effective for monitoring low-frequency electromechanical oscillations, they have inherent limitations in accurately representing higher-frequency oscillations due to constraints imposed by reporting rates and the bandwidth of phasor estimation filters. Even when configured with higher reporting rates, the filtering inherent in the phasor estimation process can significantly attenuate oscillation magnitudes, potentially leading to underestimation of oscillatory behavior. This has important implications for compliance and performance monitoring of large loads. To address the limitations associated with PMU-based monitoring, the report examines the use of high-resolution POW measurements, which can capture oscillations across a broader frequency range. However, continuous POW monitoring introduces practical challenges related to large data volumes, communication bandwidth, and real-time data processing. For this reason, the report also discusses emerging approaches that use POW measurements as a complementary capability alongside PMUs to improve observability of oscillations from large data center loads.

47 OTHER INSTRUMENTATION↗

Seasonal to Decadal Variability in Focused Groundwater and Contaminant Discharge along a Channelized Stream

Abstract Focused groundwater discharge to streams is problematic at contaminated sites because high fluxes can limit natural attenuation in the hyporheic zone. However, information on location, spatial evolution, and temporal persistence of springs in unlithified sediments over multiyear time scales is limited. We examine discharge at point (~1‐m) to reach (~300‐m) scales along a stream that intercepts trichloroethene and technetium‐99 plumes from a Superfund site. During 2011 to 2012, we seasonally monitored stream and spring flow and contaminant concentrations, along with probing streambed temperatures on a grid in winter and summer, building on prior monitoring during 1999 to 2002. Baseflow measured by both gauging and dye dilution generally increased with distance downstream, and stream and spring discharge varied seasonally, from minima in October to January to maxima in February to June. Thermal anomalies identified by probing occupied approximately 3% to 6% of the reach and typically coincided with visible springs or seeps. Locations of anomalies were similar to those identified in summer 2002, although some orifices disappeared and others emerged. Vertical groundwater fluxes calculated from probing tended to be less than net fluxes calculated from stream discharge, perhaps in part because the assumption of one‐dimensional, steady‐state flow in calculating point fluxes was simplistic. Maximum contaminant concentrations and fluxes decreased between 1999 to 2001 and 2011 to 2012 as a result of partial capture by an upgradient pump‐and‐treat system. Our findings confirm that springs in unlithified sediments can remain stationary within a few meters over decadal time scales, and seasonal variability in discharge can be greater than decadal variability.

Tripathi, Ganesh N.↗

Cyber-Physical Smart Light Control System Integration with Smart Grid using Zigbee

This paper presents a hardware-in-the-loop cyber-physical system architecture design to monitor and control smart lights connected to the active distribution grid. The architecture uses Zigbee-based (IEEE 802.15.4) wireless sensor networks and publish-subscribe architecture to exchange monitoring and control signals between smart-light actuators (SLAs) and a smart-light central controller (SLCC). Each SLA integrated into a smart light consists of a Zigbee-based endpoint module to send and receive signals to and from the SLCC. The SLCC consists of a Zigbee-based coordinator module, which further exchanges the monitoring and control signals with the active distribution management system over the TCP/IP communication network. The monitoring signals from the SLAs include light status, brightness level, voltage, current, and power data, whereas, the control signals to the SLAs include light intensity, turn ON, turn OFF, standby, and default settings. We have used our existing hardware-in-the-loop (HIL) cyber-physical system (CPS) security SCADA testbed to process signals received from the SLCC and respond suitable control signals based on the smart light schedule requirements, system operation, and active distribution grid dynamic characteristics. We have integrated the proposed cyber-physical smart light control system (CPSLCS) testbed to our existing HIL CPS SCADA testbed. We use the integrated testbed to demonstrate the efficacy of the proposed algorithm by real-time performance and latency between the SLCC and SLAs. The experiments demonstrated significant results by 100% realtime performance and low latency while exchanging data between the SLCC and SLAs.

24 POWER TRANSMISSION AND DISTRIBUTION↗