Search NASASearch

SEARCH · Search NASA

Results for “ground source heat pumps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

856 records · Page 13

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS

Selecting an Encapsulant for an Aerospace Superconducting Machine

Achieving larger benefits from electrified propulsion in single aisle aircraft (the largest commercial aircraft market segment) necessitates that a significant fraction of their 20 MW or greater propulsion system be electrified. 5 to possibly 20 of the MW-scale electric machines investigated by NASA would be required to meet this need. Approximately 10-20 of NASA’s MW-scale electric machines would be required to reach the necessary power levels. Therefore, electric machines of 5 MW or greater are of interest. However, conventionally cooled high power density MW-scale electric machines still produce a significant amount of waste heat, which makes obtaining these power levels problematic. Highly efficient fully superconducting electric machines (or those with a cryogenically cooled, high purity copper or aluminum stator) are a possible solution but have multiple barriers to be overcome. One such barrier is the durability of superconducting windings. Superconductors are typically brittle, and encapsulants used to hold windings in place are a significant source of stress because of the mismatches in coefficient of thermal expansion at temperatures between room temperature and operational temperatures (20 to 77 K). These encapsulants also form a thermal barrier that can be detrimental to cooling the superconductors. This paper describes an initial study of commercially available encapsulants as it relates to superconducting machine applications along with initial modeling of thermal stress in superconducting windings for a superconducting or cryogenically cooled stator in a 5 MW electric machine.

encapsulant

Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Change Material Heat Capacitor

A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft’s propylene glycol-water mixture coolant system. Testing was performed with the phase change material contained under sealed conditions after a degassing procedure and exposed to atmosphere without prior degassing. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements and theoretical N-Pentadecane storage capacity.

Propylene Glycol Water

Enhancing NO Reduction by CO Over NiO/CeO 2 Catalyst by Optimizing the Metal Oxide–Support Interaction

Noble metal catalysts are widely used in three-way catalysts (TWCs) due to their high efficiency, but their scarcity and high cost drive the need for effective, low-cost alternatives. Here, in this work, a series of NiO/CeO 2 catalysts were engineered by modulating the OH content and crystallite size of the CeO 2 support. This approach yielded Ni species ranging from isolated single atoms to small clusters and larger aggregates, with varied NiO/CeO 2 interaction strengths. Evaluation of their performance in NO reduction by CO, CO oxidation, and the water–gas shift reaction revealed that the NiO/CeO 2 -300 catalyst, featuring small CeO 2 crystallites and highly dispersed NiO clusters, delivered superior activity for NO reduction and CO oxidation. It was demonstrated that small NiO clusters, due to their efficient CO adsorption and activation, were more active than Ni single atoms. Furthermore, the presence of water was found to influence the catalyst stability, with NiO clusters less stable than single atoms likely due to the hydroxylation effect leading to the formation of Ni(OH) 2 . Oxygen storage capacity measurements revealed that performance was governed by a combination of CeO 2 crystallite size and the abundance of NiO/CeO 2 interfaces. These findings demonstrated that the catalytic performance of Ni/CeO 2 systems could be maximized by optimizing the Ni nanostructure and its interaction with CeO 2 support, positioning them as a promising, multifunctional nonprecious alternative for three-way catalysis application.

36 MATERIALS SCIENCE

Upper ocean mixing, surface heat fluxes, and heat content variability in the upper 150 m during Hurricane Laura (2020)

Observations (from thermistor sensors and a hurricane glider) and model-based temperature were used to answer questions including the following: 1) What physical and environmental conditions explain the rapid intensification of Hurricane Laura? 2) How did the pre-existing warm mixed layer at Stone mooring (StM) influence the degree of cooling in the mixed layer? 3) How did vertical mixing, surface heat fluxes, and advective processes collectively shape the mixed layer heat evolution at StM? Observations measured by thermistor sensors showed that Hurricane Laura induced a cooling of -1.2oC in the mixed layer when Hurricane Laura’s wind speed increased to 47 m/s on 26 August. This contrasts with the -1.04oC mixed layer temperature change estimated from model-based temperature. At StM, the presence of a 31oC warm mixed layer and elevated heat content (60-80kJ/cm2) effectively preconditioned the upper ocean ahead of Hurricane Laura’s passage. After Hurricane Laura passed, turbulent mixing associated with the storm transported the heat anomalies downward into subsurface layers. In addition, this study shows that a surface heat flux of 5.04 kJ/cm2 supported the intensity of Hurricane Laura as it traversed over the StM. Using a mixed layer heat balance model, this study shows that entrainment flux and surface flux mostly contributed to the observed change in the mixed layer temperature.

Tsai, Senam

RADAI: A Large-Scale Realistic Dataset for Radiation Detection Algorithm Development

Open, realistic datasets are essential for developing and benchmarking radiation detection algorithms, yet they remain scarce. The Radiological Anomaly Detection and Identification (RADAI) project was develop to create datasets that meet the training and testing needs for sophisticated radiation detection algorithms. The RADAI dataset is a large-scale synthetic resource that integrates high-fidelity Monte Carlo simulations with realistic urban scenarios to capture both background variability and source signatures. RADAI models construction-material NORM, people and vehicles, urban clutter, and dynamic environmental effects such as cosmic-ray and rain-induced transients, and they provide list-mode detector data with motion and response modeling suitable for algorithm training and evaluation. The RADAI project resulted in three publicly-released complementary datasets together with an online scoring portal for standardized performance assessment and an open software toolkit that supports data access, augmentation, model development, and evaluation. These resources enable reproducible comparisons across methods and promote rigorous studies at the scale required by contemporary machine learning. By grounding algorithm development in realistic, well-documented conditions, RADAI supports progress toward more robust detection, identification, and localization in complex urban environments.

Ghawaly, James M. [Division of Computer Science an

Experimental Characterization of Additively Manufactured Nickel-Titanium Shape Memory Alloy Heat Pipes

Shape memory alloys (SMA) have been identified for use in spacecraft components as replacement for conventional deployment mechanisms. They may be used in thermal management components such as radiators to create self-deploying radiators. One SMA, NiTi, has also been developed for additive manufacturing processes. Heat pipes are a common way to create highly effective and lightweight spaceflight radiators, and heat pipes can also be made from NiTi and related alloys. The wick is the critical element of a functioning heat pipe, and recent progress over the past years has led to the development of additively manufactured heat pipe wicks in various materials. The combination of these efforts is the focus of this project: creating an additively manufactured, shape memory alloy self-deploying heat pipe radiator. This paper will focus on the experimental characterization of these additively manufactured NiTi heat pipes. The heat pipe coupons were additively manufactured by direct metal laser sintering (DMLS), with an integral liquid cooled condenser. Heat is input to the heat pipe via a thin film heater. Thermocouples were spot welded to the heat pipes to measure temperature at several axial locations. The heat pipes were tested with two working fluids: water and ethanol. Ethanol is not an ideal working fluid for heat pipes but is useful in characterizing them because it wets well to a wide variety of surfaces. Water is in general a superior working fluid for heat pipes, but its contact angle and therefore wicking performance strongly depends on the surface chemistry of the surface it is in contact with. A particular measurement of interest in this test is the evaporator to condenser thermal conductance, which will be compared in the full paper to recently published correlations for additively manufactured heat pipes. Experimental results for two straight geometry and one bellows geometry heat pipe will be presented. The bellows geometry is of interest for condenser of the self-deploying radiator design.

Additive manufacturing

Nuclear Safety [Vol. 36, No. 1, January-June 1995]

Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. THE CHORNOBYL ACCIDENT: 1 The Chornobyl Accident Revisited, Part II: The State of the Nuclear Fuel Located Within the Chornobyl Sarcophagus, A A. Borovoi and A. R. Sich; GENERAL SAFETY CONSIDERATIONS: 33 Nuclear Power Safety in Central and Eastern Europe, R. Wilson; 46 Safety of Nuclear Power Reactors in the Former Eastern European Countries, S. Chakraborty; 53 Technical Note: On the Definition of Common-Cause Failures, H. Paula; ACCIDENT ANALYSIS: 58 Modeling and Analysis of Core-Debris Recriticality During Hypothetical Severe Accidents in the Advanced Neutron Source Reactor, S.-H. Kim, V. Georgevich, D. B. Simpson, C. O. Slater, and R. P. Taleyarkhan; 68 Ignitability of Hydrogen/Oxygen/Diluent Mixtures in the Presence of Hot Surfaces, R. K. Kumar and G. W. Koroll; 94 Coupled RELAP5 and CONTAIN Accident Analysis Using PVM, K. A. Smith, A. J. Baratta, and G. E. Robinson; CONTROL AND INSTRUMENTATION: 109 Application of Fuzzy Logic in Nuclear Reactor Control Part I: An Assessment of State-of-the-Art, A. S. Heger, N. K. Alang-Rashid, and M. Jamshidi; DESIGN FEATURES: 122 Twenty-Third DOE/NRC Nuclear Air-Cleaning and Treatment Conference, R. R. Bellamy, J. J. Hayes, and M. W. First; ENVIRONMENTAL EFFECTS: 135 Atmospheric Dispersion and the Radiological Consequences of Normal Airborne Effluents from a Nuclear Power Plant, D. Fang, C. Z. Sun, and L. Yang; 142 Calculation of Distribution Coefficients for Radionuclides in Soils and Sediments, I. Puigdomenech and U. Bergstrom: OPERATING EXPERIENCES: 155 Reactor Shutdown Experience, Compiled by J. W. Cletcher; U.S. NUCLEAR REGULATORY COMMISSION INFORMATION AND ANALYSES: 158 Operating Experience Feedback Report—Reliability of Safety-Related Steam Turbine-Driven Standby Pumps Used in U.S. Commercial Nuclear Power Plants, J. R. Boardman; 166 Turbine Building Hazards, H. L Ornstein; RECENT DEVELOPMENTS: 169 Reports, Standards, and Safety Guides, D. S. Queener; 175 Proposed Rule Changes as of Dec. 31,1994; ANNOUNCEMENTS: 32 Harvard School of Public Health In-Place Filter Testing Workshop; 134 International Conference on Advances in the Operational Safety of Nuclear Power Plants; 193 30th Tennessee Industries Week; 193 DOE Technical Standards Program 1995 Workshop; 194 Multiphase Flow Experiments and Instrumentation; 180 The Authors; 185 Indexes to Nuclear Safety, Volumes 34 and 35.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Minimum Heating Re-Entry Trajectories for Advanced Hypersonic Launch Vehicles

Optimal re-entry trajectories are generated for reusable launch vehicles which minimize: (1) the heat absorbed at the vehicle surface, (2) the lower surface temperature, and (3) the heat absorbed by the internal structure. The approach uses the energy state approximation technique and a finite control volume heat transfer code coupled to a flight path integration code. These trajectories are compared to the optimal re-entry trajectory minimizing the integrated convective heat rate to determine which trajectory produces the minimum internal structural temperatures for a given thermal protection system. Three different thermal protection systems are considered: tile, blanket, and metallic.

Robert Windhorst

Salt to Metal to Salt Heat Transfer in Narrow Fuel Pins (Final CRADA Report)

This work focused on improving the understanding and modeling of conjugate heat transfer in the Stable Salt Reactor (SSR), particularly the transfer of heat from molten fuel salt inside narrow fuel pins, through the metal cladding and into the surrounding coolant salt.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS

NASA 50 amp hour nickel cadmium battery waste heat determination

A process for determining the waste heat generated in a 50-ampere-hour, nickel cadmium battery as a function of the discharge rate is described and results are discussed. The technique involved is essentially calibration of the battery as a heat transfer rate calorimeter. The tests are run at three different levels of battery activity, one at 40-watts of waste heat generated, one at 60, and one at 100. Battery inefficiency ranges from 14 to 18 percent at discharge rates of 284 to 588 watts, respectively and top-of-cell temperatures of 20 C.

Mueller, V. C.

Novel Method for Domestic Stable Isotope Production (CRADA #667) Final Report

This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species (35Cl- and 37Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.

07 ISOTOPE AND RADIATION SOURCES

Thermal Protection Facility: Taking the Heat

Video highlighting the products and manufacturing capabilities of the Thermal Protection Facility at Kennedy Space Center which is part of the JSC EA/ES division. This record includes an mp4 video with a run time of 9 min. 13 sec.; in color; with sound.

TPSF

Socio-Techno-Economic Feasibility of Deep Geothermal with EGS for Residential District Heating in the Northeastern United States

In this paper, we present socio-techno-economic simulation results for enhanced geothermal system (EGS) district heating systems in the northeastern United States. We applied the geospatial Distributed Geothermal Market Demand (dGeo) tool coupled with GEOPHIRES to evaluate the feasibility of geothermal deep direct-use, utilizing EGS reservoirs for providing residential heating with district heating systems. The results were combined with JEDI results to assess social impacts. Simulation results assuming doublet EGS reservoirs with target production temperature of 80 degrees C and newly constructed district heating systems indicate a wide range in system levelized cost of heat (LCOH) values ranging from ~$15/MMBtu to over $1,000/MMBtu, with most the attractive regions urban areas with high total thermal demand and high thermal demand density. We estimate about 60 GWth in potential installed capacity with LCOH values under $50/MMBtu and 100 GWth in potential capacity with LCOH values under $100/MMBtu, respectively.

15 GEOTHERMAL ENERGY