Development of a high-temperature Inconel 625 heat exchanger by model design and binder jetting additive manufacturing

A nickel-based Inconel 625 superalloy heat exchanger for high-temperature applications was developed via binder jetting additive manufacturing. The material properties were characterized first on printed and sintered parts. Two sintering temperatures were used to investigate the effects of the temperature on densification and microstructure. For channel geometry design, the heat transfer capabilities of the heat exchanger were optimized for the cross-section geometry of fluid flow channels in a counterflow configuration, and a stress analysis was conducted to investigate the effects of channel geometry. After headers were incorporated into the heat exchanger as a one-piece component, a prototype was printed. A complete depowdering was achieved via compressed air blowing, and sintering was performed with the developed profile. Ultimately, a one-piece heat exchanger with a nearly full density was obtained. Heat transfer tests were performed on this unit, and the results were compared with those from the simulations. In this study, systematic processes were developed for an additively manufactured Inconel-based heat exchanger for high-pressure, high-temperature heat transfer applications.

36 MATERIALS SCIENCE↗

Micro-Scale Regenerative Heat Exchanger

A micro-scale regenerative heat exchanger has been designed, optimized and fabricated for use in a micro-Stirling device. Novel design and fabrication techniques enabled the minimization of axial heat conduction losses and pressure drop, while maximizing thermal regenerative performance. The fabricated prototype is comprised of ten separate assembled layers of alternating metal-dielectric composite. Each layer is offset to minimize conduction losses and maximize heat transfer by boundary layer disruption. A grating pattern of 100 micron square non-contiguous flow passages were formed with a nominal 20 micron wall thickness, and an overall assembled ten-layer thickness of 900 microns. Application of the micro heat exchanger is envisioned in the areas of micro-refrigerators/coolers, micropower devices, and micro-fluidic devices.

Moran, Matthew E.↗

Inverted heat exchanger device

An inverted heat exchanger device includes an exterior conduit elongated and extending around a center axis between a first end and second end. The exterior conduit including a body having an exterior surface, an interior surface, a center core elongated along the center axis, and plural walls extending between the center core and the interior surface. A first conduit is disposed inside the exterior conduit that includes an inlet, plural core passages, an outlet, and internal manifolds. A first fluid is configured to flow along the first conduit. A second conduit is also disposed inside the exterior conduit. The second conduit includes an inlet, plural core passages, an outlet, and internal manifolds. A second fluid is configured to flow along the second conduit. The plural walls are configured to define the first conduit and the second conduit within the body of the exterior conduit.

de Bock, Hendrik Pieter Jacobus↗

Development and fabrication of a diffusion welded Columbium alloy heat exchanger

A Mini Brayton space power generation system required the development of a Columbium alloy heat exchanger to transfer heat from a radioisotope heat source to a He/Xe working fluid. A light-weight design featured the simultaneous diffusion welding of 148 longitudinal fins in an annular heat exchanger about 9-1/2 in. in diameter, 13-1/2 in. in length and 1/4 in. in radial thickness. To complete the heat exchanger, additional gas ducting elements and attachment supports were added by GTA welding in a vacuum-purged inert atmosphere welding chamber. The development required the modification of an existing large size hot isostatic press to achieve HIP capabilities of 2800 F and 10,000 psi for at least 3 hr. Excellent diffusion welds were achieved in a high-quality component which met all system requirements.

Zimmerman, W. F.↗

Experimental Investigation of a Novel Membrane-Based Condensing Heat Exchanger for High Efficiency Furnaces

Building space heating consumes approximately one-third of all global natural gas end use. Higher-efficiency (i.e., condensing) furnaces constitute only about 30% of the annual furnace shipments in the United States because the condensing heat exchangers must use highly expensive, corrosion-resistant materials to be protected from acidic components in the furnace flue gas stream. Increasing the market share of high-efficiency furnaces will reduce greenhouse gas emissions. This study developed and tested a benchtop prototype of a novel membrane-based heat exchanger (MHX) for high-efficiency furnaces to achieve nonacidic condensation via nanoporous membranes. Test results show that both sensible and latent heat were recovered by the MHX, and the fraction of latent heat recovery ranged from about 25% to 45% over the range of operating conditions evaluated. The amount of water condensed through the MHX increased with the increase of flue gas flow rate and decreased with increasing coolant temperature. The fraction of latent heat recovery decreased with the increase of flue gas flow rate and coolant temperature. The pH value of condensed water from the MHX was only mildly acidic, varying from 5.3 to 5.6 without any additional treatment, about 2.0 to 2.3 pH points higher (i.e., less acidic) than typical values for the condensate from conventional condensing furnaces. Therefore, feasibility of the MHX was experimentally verified, and the MHX could enable wider market penetration of highly energy-efficient condensing furnaces by reducing costs associated with managing the acid condensation compared with conventional condensing furnaces, possibly enabling the use of existing vent systems when replacing noncondensing furnaces (due to higher flue gas exit temperatures), and possibly reducing furnace first costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cross flow ceramic heat exchanger and method for manufacturing

A heat exchanger includes a first additively manufactured layer including axial fins extending in a first direction and transverse fins extending in a second direction transverse to the first direction, the first layer defining a flow path in the first direction. The heat exchanger also includes a second additively manufactured layer including axial fins extending in the second and transverse fins extending in the first direction, the second layer defining a second flow path in the second direction.

36 MATERIALS SCIENCE↗

Life cycle assessment of novel heat exchanger for dry cooling of power plants based on encapsulated phase change materials

Cooling systems in power plants account for approximately 40% of total freshwater withdrawals in the U.S. Due to dwindling access to freshwater resources worldwide, continued operation of wet cooling systems poses a significant engineering challenge. To reduce water consumption, a novel air-cooled heat exchanger has been developed using encapsulated phase change material (EPCM) for dry cooling of power plants. Compared to traditional finned-tube air-cooled condensers, this novel EPCM heat exchanger improves the heat transfer coefficient and power plant efficiency while reducing the pressure drop and cooling system cost. Life cycle assessment (LCA) and techno-economic analysis (TEA) are used to evaluate the environmental and economic performance of EPCM heat exchangers from cradle-to-grave and to compare them to wet cooling and traditional air-cooled condensers. A thermodynamic model is developed to predict the EPCM heat exchanger performance for plant-scale operations. Equipment and construction costs for heat exchangers are estimated based on design parameters obtained from the thermodynamic model. Both process-LCA and economic-input–output LCA are used to simulate and test the sensitivity of EPCM alternatives with commercial wet and dry cooling technologies. We investigate options for EPCM end-of-life management upon retiring the heat exchanger and construct a process-based LCA model to estimate a greenhouse gas (GHG) emissions credit for recycling the EPCM. The life cycle GHG emission of the novel dry cooling technology is 1.16 kg CO 2 eq. /MWh compared with the 1.1–4.3 kg CO 2 eq. /MWh reported for commercial dry cooling technologies and consumes 9.5 L/MWh e of water for cradle-to-gate life cycle, which is significantly lower than that of wet cooling systems. The TEA shows many advantages of EPCM cooling technology over the state-of-art dry cooling solutions. Overall, the EPCM heat exchanger provides a better alternative compared to existing dry cooling and wet cooling technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical Analysis of Novel Plate Type Heat Exchanger with Oval-Twisted Channels

The novel heat exchanger (HX) designs implementing geometrical and surface modification combinations are expected to perform better than traditional HX technologies. Applied enhancement techniques seek to achieve (1) higher overall heat transfer performance, (2) increased compactness, and (3) simplified or comparable manufacturability. One innovative enhancement technique is to generate swirling flow vortices induced by channel or tube twisting. The turbulence generated by the twisted cross-section greatly enhances the heat transfer rate with minimal increases in pressure drop. Plate-type HXs and Printed Circuit Heat Exchangers (PCHXs) are compact designs that achieve high heat transfer rates per unit volume by utilizing several small channels, which maximizes the heat transfer surface area between the hot and cold fluids. Currently, advanced manufacturing technologies enable the design and fabrication of compact-type units with complicated channel geometries to achieve the highest performance and meet the compactness criteria of innovative HX technology. The proposed HX design concept combines the compactness of plate-type HXs and twisted channels, which provide additional turbulence and flow swirl enhancement. The plate-type oval-twisted HX (PTOTHX) is a crossflow configuration, with 16 short channels on one side (for hot fluid) and 8 long channels on the perpendicular side (for cold fluid). The inlet plenums have flow guide vanes to redirect flow and produce uniformity across the various flow paths. The compact size and purportedly improved heat transfer performance of the PTOTHX investigated herein prove its viability in various applications. Some notable potential nuclear applications of the PTOTHX include reactor core, spent fuel cooling, and residual heat dissipation. To establish a reference case, circular channels (PTCHX) are also considered in the present study for comparison with (PTOTHX). This paper aims to outline the numerical analysis procedures for determining the viability of the PTOTHX by comparing its heat transfer performance with the PTCHX units. The computational study used STAR-CCM+, a commercial computational fluid dynamics (CFD) code. Sensitivity analysis and model selection studies are conducted to determine the appropriate mesh density and turbulence model to provide the reported results. Numerical analyses comparing the Nusselt number (Nu) of the PTOTHX design with a comparable HX unit, including a circular cross-section and no twisting (PTCHX), show an overall heat transfer performance increase of 29-55% for balanced flow and 29-59% for imbalanced flow. Oval-cross-sectional twisted channels induce swirling flow vortices, enhancing the working fluid's convective heat transfer capabilities.

25 ENERGY STORAGE↗

Case Study of Using Flocad to Model a Ground Test Station Ln2 Heat Exchanger

This paper presents a case study of using FLOCAD to model the heat transfer and boiling flow behavior of a Liquid Nitrogen (LN2) ground station equipment heat exchanger. The unique aspect of this work is that is one of very few studies documenting the use of FLOCAD in the spacecraft thermal control community. The results of the simulations described herein were used to guide and plan the execution of thermal vacuum testing spacecraft hardware using a ground test heat exchanger such as the one modeled herein. The paper will review the theory of two-phase boiling flow and correlations used by SINDA/FLUINT as well as the terminology and nomenclature used within Thermal Desktop / FLOCAD regarding two-phase boiling flow heat transfer modeling and simulation. Results for using the ground station heat exchanger as a heat sink in a thermal vacuum test set up are shown in order to demonstrate the set-up and execution of a typical FLOCAD model. Results indicate that properly modeling of the two-phase behavior is critical in order to ascertain the time constant associated with the heat exchanger, as well as understanding the temperature distribution across the test equipment and prediction of required LN2 flowrates to be used during testing. The paper is meant to augment the FLOCAD user’s manual and serve as a tutorial for thermal engineers and analysts wishing to learn and apply FLOCAD to industrial problems.

Anderson, Kevin R.↗

Thermal/Fluid Analysis of a Composite Heat Exchanger for Use on the RLV Rocket Engine

As part of efforts to design a regeneratively cooled composite nozzle ramp for use on the reusable vehicle (RLV) rocket engine, a C-SiC composite heat exchanger concept was proposed for thermal performance evaluation. To test the feasibility of the concept, sample heat exchanger panels were made to fit the Glenn Research Center's cell 22 for testing. Operation of the heat exchanger was demonstrated in a combustion environment with high heat fluxes similar to the RLV Aerospike Ramp. Test measurements were reviewed and found to be valuable for the on-going fluid and thermal analysis of the actual RLV composite ramp. Since the cooling fluid for the heat exchanger is water while the RLV Ramp cooling fluid is LH2, fluid and therma models were constructed to correlate to the specific test set-up. The knowledge gained from this work will be helpful for analyzing the thermal response of the actual RLV Composite Ramp. The coolant thermal properties for the models are taken from test data. The heat exchanger's cooling performance was analyzed using the Generalized Fluid System Simulation Program (GFSSP). Temperatures of the heat exchanger's structure were predicted in finite element models using Patran and Sinda. Results from the analytical models and the tests show that RSC's heat exchanger satisfied the combustion environments in a series of 16 tests.

Nguyen, Dalton↗

Thermal/Fluid Analysis of a Composite Heat Exchanger for Use on the RLV Rocket Engine

As part of efforts to design a regeneratively cooled composite nozzle ramp for use on the reusable vehicle (RLV) rocket engine, an C-SiC composites heat exchanger concept was proposed for thermal performance evaluation. To test the feasibility of the concept, sample heat exchanger panels were made to fit the Glenn Research Center's cell 22 for testing. Operation of the heat exchanger was demonstrated in a combustion environment with high heat fluxes similar to the RLV Aerospike Ramp. Test measurements were reviewed and found to be valuable for the on going fluid and thermal analysis of the actual RLV composite ramp. Since the cooling fluid for the heat exchanger is water while the RLV Ramp cooling fluid is LH2, fluid and thermal models were constructed to correlate to the specific test set-up. The knowledge gained from this work will be helpful for analyzing the thermal response of the actual RLV Composite Ramp. The coolant thermal properties for the models are taken from test data. The heat exchanger's cooling performance was analyzed using the Generalized Fluid System Simulation Program (GFSSP). Temperatures of the heat exchanger's structure were predicted in finite element models using Patran and Sinda. Results from the analytical models and the tests show that RSC's heat exchanger satisfied the combustion environments in a series of 16 tests.

Nguyen, Dalton↗

Laminar Flow Heat Transfer In Helical Oval-Twisted Tube for Heat Exchanger Applications

The heat transfer performance of a novel tube configuration that combines the swirling velocity induced by oval-twisting and secondary flow generated by a helical geometrical flow path is presented. The Nusselt number (Nu) and friction factor (f) are compared for the laminar flow regime (Re = 250- 2000) under isothermal wall conditions. Under the same flow and boundary conditions, the oval-twisted helical tube increased the Nu and slightly increased the f over the circular helical tube. The best performance with the highest Nuand lowest f occurs at the coil curvature ratio (d h /D) of 0.17. The quantified enhancement performance factor (h) shows a 46 - 56% increase for the oval-twisted helical tube over the circular helical tube with d h /D = 0.17. Correlations for the Nu and f are developed and agreed with the numerical results: ± 6% and ± 5% for the Nu and f, respectively.

42 ENGINEERING↗

Dynamic Behavior of Oval-Twisted Helical Tube Heat Exchanger: Numerical Study with RELAP5-3D

Convective heat transfer characteristics and theoretical thermal stress behaviors are numerically calculated using RELAP5-3D for the helical-coiled once-through steam generator (H-OTSG) and the novel heat exchanger design known as the oval-twisted helically coiled heat exchanger (OTHCHX) under (1) fluctuating wall temperature conditions, (2) square-wave pulsating flow conditions, and (3) the combined effects of fluctuating wall temperature and square-wave pulsating flow conditions. Heat transfer coefficient models for the H-OTSG and OTHCHX were developed based on existing data and implemented into RELAP5-3D, successfully capturing the N⁢uavg behavior within 8% to 10% of the reported data. Under fluctuating wall temperature conditions, the OTHCHX displayed higher N⁢u avg behavior than the H-OTSG. As 𝑓 increased, the $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ decreased. The $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ was higher for the OTHCHX than for the H-OTSG under fluctuating wall temperature conditions. Under pulsating flow conditions, the H-OTSG and OTHCHX displayed much higher 𝑁⁢𝑢 𝑎𝑣𝑔 than under constant flow conditions. The H-OTSG displayed a higher $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ over the OTHCHX. Under combined fluctuating wall temperature and pulsating flow conditions, the augmented heat transfer behavior from the pulsating flow was counteracted by the wall temperature fluctuations, producing slightly higher 𝑁⁢𝑢 𝑎𝑣𝑔 over constant wall temperature, constant flow conditions, but much lower than only constant pulsating flow under constant wall temperature conditions. The effects of simultaneous wall temperature fluctuations and square-wave pulsating flow caused higher $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ than that of only wall temperature fluctuations or pulsating flow. As the Reynolds number (Re) increased, $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ increased. However, when 𝑓=𝑓$_{\dot{m}}$, the $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ showed decreasing values as Re increased. In conclusion, the results indicate that thermal-fluid resonance can help mitigate thermal stresses.

Thermal stress↗

Modeling of Additively Manufactured Ceramic Heat Exchangers with Semi-Elliptical Cross-Section Flow Channels

An approximate and easily applied analytical model was developed for heat transfer calculations of heat exchangers consisting of multiple rows and columns of heat transfer fluid flow channels with semi-elliptical cross sections. Heat exchangers of this type are being developed by using ceramic material and additive manufacturing for high temperature and pressure-concentrating solar electric power plants. Calculations using the model require only the geometrical dimensions and flow conditions of the heat exchanger. Comparisons of modeling predictions, with both simulation results and experimental data, were conducted to verify the viability of the model. The results showed good agreement where almost all the modeling predictions were within 20% of the simulation results or the experimental data. Finally, the proposed modeling approach is more generally applicable to heat transfer analysis of heat exchangers with similar flow channel configurations to those considered in this study.

Ceramic↗

Fouling modeling and prediction approach for heat exchangers using deep learning

In this article, we develop a generalized and scalable statistical model for accurate prediction of fouling resistance using commonly measured parameters of industrial heat exchangers. This prediction model is based on deep learning where a scalable algorithmic architecture learns non-linear functional relationships between a set of target and predictor variables from large number of training samples. Here, the efficacy of this modeling approach is demonstrated for predicting fouling in an analytically modeled cross-flow heat exchanger, designed for waste heat recovery from flue-gas using room temperature water. The performance results of the trained models demonstrate that the mean absolute prediction errors are under 10 –4 KW –1 for flue-gas side, water side and overall fouling resistances. The coefficients of determination (R 2 ), which characterize the goodness of fit between the predictions and observed data, are over 99%. Even under varying levels of measurement noise in the inputs, we demonstrate that predictions over an ensemble of multiple neural networks achieves better accuracy and robustness to noise. We find that the proposed deep-learning fouling prediction framework learns to follow heat exchanger flow and heat transfer physics, which we confirm using locally interpretable model agnostic explanations around randomly selected operating points. Overall, we provide a robust algorithmic framework for fouling prediction that can be generalized and scaled to various types of industrial heat exchangers.

42 ENGINEERING↗

Dual Expander Cycle Rocket Engine with an Intermediate, Closed-cycle Heat Exchanger

A dual expander cycle (DEC) rocket engine with an intermediate closed-cycle heat exchanger is provided. A conventional DEC rocket engine has a closed-cycle heat exchanger thermally coupled thereto. The heat exchanger utilizes heat extracted from the engine's fuel circuit to drive the engine's oxidizer turbomachinery.