Optimized faster R-CNN for oil wells detection from high-resolution remote sensing images
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Abstract We present a new algorithm to track the amplitude and phase of rotating magnetohydrodynamic (MHD) modes in tokamak plasmas using high speed imaging cameras and deep learning. This algorithm uses a convolutional neural network (CNN) to predict the amplitudes of the n = 1 sine and cosine mode components using solely optical measurements from one or more cameras. The model was trained and tested on an experimental dataset consisting of camera frame images and magnetic-based mode measurements from the High Beta Tokamak - Extended Pulse (HBT-EP) device, and it outperformed other, more conventional, algorithms using identical image inputs. The effect of different input data streams on the accuracy of the model’s predictions is also explored, including using a temporal frame stack or images from two cameras viewing different toroidal regions.
Abstract not provided.
Explore the source record for details and available documents.
Abstract not provided.
This project aims to advance neutron technologies that support subcritical experiments (SCEs) and other dynamic material applications. In previous years, there were three main thrusts for this project. The first and main effort focused on imaging the source of neutrons on a dense plasma focus (DPF). The second portion focused on improving the neutron yield from a DPF. The source developed on the Nevada National Security Site (NNSS) Gemini DPF yielded ~8 × 10 11 deuterium-deuterium (DD) neutrons/pulse in relatively short pulse widths of approximately 100 ns FWHM.
Abstract not provided.
The Los Alamos Ignition Threshold team is planning direct-drive cylinder implosion experiments (CylDRT24B) at the OMEGA laser, scheduled for Thursday 23 May 2024, to investigate the effect of granular microstructure in high density carbon (HDC) shells. Granular microstructure is believed to play a crucial role in seeding perturbations, reducing compression, and enhancing mix in the implosion of HDC shells at the National Ignition Facility (NIF). But the ICF community lacks a detailed understanding of how grains induce these effects, owing partly to the practical difficulty of numerically simulating the behavior of tiny nanometer-scale granular structures in laboratory-scale experiments. Our planned experiments are aimed at acquiring data to help constrain simulations and calibrate reduced models.
The objective of this work is to assess the accuracy of measurements made by the Electron Beam Profile Scanner (EBPS), which captures the trajectory of an electron beam with and without a proton beam present. The proton beam induces deflection in the electron beam, which is influenced by proton charges. For high-resolution images, the probe beam needs to be of high intensity, small diameter, and small divergence, evaluated using a phosphor screen and an optical transition radiation (OTR) screen. The capabilities of the Kimball Physics electron gun (eGun) will be considered for accuracy. Additionally, the Zemax software will be utilized to characterize the optical elements.
We propose a deterministic sampling framework using Score-Based Transport Modeling for sampling an unnormalized target density π given only its score ∇ log π. Our method approximates the Wasserstein gradient flow on KL($f_t$∥π) by learning the time-varying score ∇ log $f_t$ on the fly using score matching. While having the same marginal distribution as Langevin dynamics, our method produces smooth deterministic trajectories, resulting in monotone noise-free convergence. We prove that our method dissipates relative entropy at the same rate as the exact gradient flow, provided sufficient training. Numerical experiments validate our theoretical findings: our method converges at the optimal rate, has smooth trajectories, and is often more sample efficient than its stochastic counterpart. Experiments on high-dimensional image data show that our method produces high-quality generations in as few as 15 steps and exhibits natural exploratory behavior. The memory and runtime scale linearly in the sample size.
Explore the source record for details and available documents.
Abstract not provided.
Presentation to be presented during the Site-Directed Research and Development (SDRD) program FY 2021 review meeting (Webex), September 22–23, 2021.
A radio frequency (RF) based waveguide health monitoring system is disclosed. The system employs an RF transmitter for launching a probe RF waveform into a waveguide. Reflections, etc., from the interior of the waveguide of the probe RF waveform create a signature RF waveform, with a health RF receiver receiving this resultant signature RF waveform. A health processing system analyzes the signature RF waveform, and when it detects a change indicative of a deformation of the waveguide, generates a warning signal. This change may be due to bends, flexes, vibrations (or changes in vibrations), or separations of the waveguide. The system may have low frequency, high frequency, or high frequency imaging modes. The system may employ a high-power probe RF waveform, thereby enabling a wireless charging system with power RF receivers located along the length of the waveguide providing additional functionality.
Abstract not provided.
Transient terahertz time-domain spectroscopy (THz-TDS) imaging has emerged as a novel non-ionizing and noninvasive biomedical imaging modality, designed for the detection and characterization of a variety of tissue malignancies due to their high signal-to-noise ratio and submillimeter resolution. We report our design of a pair of aspheric focusing lenses using a commercially available lens-design software that resulted in about 200 × 200-μm2 focal spot size corresponding to the 1-THz frequency. The lenses are made of high-density polyethylene (HDPE) obtained using a lathe fabrication and are integrated into a THz-TDS system that includes low-temperature GaAs photoconductive antennae as both a THz emitter and detector. The system is used to generate high-resolution, two-dimensional (2D) images of formalin-fixed, paraffin-embedded murine pancreas tissue blocks. The performance of these focusing lenses is compared to the older system based on a pair of short-focal-length, hemispherical polytetrafluoroethylene (TeflonTM) lenses and is characterized using THz-domain measurements, resulting in 2D maps of the tissue refractive index and absorption coefficient as imaging markers. For a quantitative evaluation of the lens effect on the image resolution, we formulated a lateral resolution parameter, R2080, defined as the distance required for a 20–80% transition of the imaging marker from the bare paraffin region to the tissue region in the same image frame. The R2080 parameter clearly demonstrates the advantage of the HDPE lenses over TeflonTM lenses. The lens-design approach presented here can be successfully implemented in other THz-TDS setups with known THz emitter and detector specifications.
Among current deep learning approaches for synthetic image generation, diffusion-based models stand out in terms of algorithmic stability and ability to retain high-fidelity image features with detailed resolution. Here, in this work, we employ Dreambooth, a method for fine-tuning Stable Diffusion, on X-ray CT images of microstructure of the polymer-bonded form (PBX) of a commonly used high explosive, Pentaerythritol tetranitrate (PETN), which yields generative models for creating synthetic PBX images. The models developed here represent five classes (or ‘lots’) of microstructures and demonstrate successful generation of images of each class with high fidelity, as verified by computed classification accuracy of ∼ 94% or higher. Data augmentation afforded by such image synthesis can be used to more reliably decipher underlying statistics, build processing-structure correlations, recognize off-normal structural anomalies, and identify age-related changes. Ideas related to converting image data into appropriate density mapping and performing mesoscale simulation or surrogate modeling of detonation are also discussed.