Search NASA⌕ Search

SEARCH · Search NASA

Results for “image quality structure material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

IMRT for Image-Guided Single Vocal Cord Irradiation

Purpose: We have been developing an image-guided single vocal cord irradiation technique to treat patients with stage T1a glottic carcinoma. In the present study, we compared the dose coverage to the affected vocal cord and the dose delivered to the organs at risk using conventional, intensity-modulated radiotherapy (IMRT) coplanar, and IMRT non-coplanar techniques. Methods and Materials: For 10 patients, conventional treatment plans using two laterally opposed wedged 6-MV photon beams were calculated in XiO (Elekta-CMS treatment planning system). An in-house IMRT/beam angle optimization algorithm was used to obtain the coplanar and non-coplanar optimized beam angles. Using these angles, the IMRT plans were generated in Monaco (IMRT treatment planning system, Elekta-CMS) with the implemented Monte Carlo dose calculation algorithm. The organs at risk included the contralateral vocal cord, arytenoids, swallowing muscles, carotid arteries, and spinal cord. The prescription dose was 66 Gy in 33 fractions. Results: For the conventional plans and coplanar and non-coplanar IMRT plans, the population-averaged mean dose {+-} standard deviation to the planning target volume was 67 {+-} 1 Gy. The contralateral vocal cord dose was reduced from 66 {+-} 1 Gy in the conventional plans to 39 {+-} 8 Gy and 36 {+-} 6 Gy in the coplanar and non-coplanar IMRT plans, respectively. IMRT consistently reduced the doses to the other organs at risk. Conclusions: Single vocal cord irradiation with IMRT resulted in good target coverage and provided significant sparing of the critical structures. This has the potential to improve the quality-of-life outcomes after RT and maintain the same local control rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structural and electrical properties of high-quality 0.41 μm-thick InSb films grown on GaAs (1 0 0) substrate with In{sub x}Al{sub 1−x}Sb continuously graded buffer

High-quality InSb was grown on a GaAs (1 0 0) substrate with an InAlSb continuously graded buffer (CGB). The temperatures of In, Al K-cells and substrate were modified during the growth of InAlSb CGB. The cross-section TEM image reveals that the defects due to lattice-mismatch disappear near lateral structures in CGB. The measured electron mobility of 0.41 μm-thick InSb was 46,300 cm{sup 2}/Vs at 300 K. These data surpass the electron mobility of state-of-the-art InSb grown by other methods with similar thickness of InSb.

36 MATERIALS SCIENCE↗

On the detection of crevasses in glacial ice with synthetic-aperture radar.

The intent of this study is to provide an analysis of the scattering from a crevasse in Antarctic ice, utilizing a physics-based model for the scattering process. Of primary interest is a crevasse covered with a snow bridge, which makes the crevasse undetectable in visible-light images. It is demonstrated that a crevasse covered with a snow bridge can be visible in synthetic-aperture-radar (SAR) images. The model of the crevasse and snow bridge incorporates a complex dielectric permittivity model for dry snow and ice that takes into account the density profile of the glacier. The surface structure is based on a fractal model that can produce sastrugi-like features found on the surface of Antarctic glaciers. Simulated phase histories, computed with the Shooting and Bouncing Ray (SBR) method, are processed into SAR images. The viability of the SBR method for predicting scattering from a crevasse covered with a snow bridge is demonstrated. Some suggestions for improving the model are given.

36 MATERIALS SCIENCE↗

Rapid Prototyping Integrated With Nondestructive Evaluation and Finite Element Analysis

Most reverse engineering approaches involve imaging or digitizing an object then creating a computerized reconstruction that can be integrated, in three dimensions, into a particular design environment. Rapid prototyping (RP) refers to the practical ability to build high-quality physical prototypes directly from computer aided design (CAD) files. Using rapid prototyping, full-scale models or patterns can be built using a variety of materials in a fraction of the time required by more traditional prototyping techniques (refs. 1 and 2). Many software packages have been developed and are being designed to tackle the reverse engineering and rapid prototyping issues just mentioned. For example, image processing and three-dimensional reconstruction visualization software such as Velocity2 (ref. 3) are being used to carry out the construction process of three-dimensional volume models and the subsequent generation of a stereolithography file that is suitable for CAD applications. Producing three-dimensional models of objects from computed tomography (CT) scans is becoming a valuable nondestructive evaluation methodology (ref. 4). Real components can be rendered and subjected to temperature and stress tests using structural engineering software codes. For this to be achieved, accurate high-resolution images have to be obtained via CT scans and then processed, converted into a traditional file format, and translated into finite element models. Prototyping a three-dimensional volume of a composite structure by reading in a series of two-dimensional images generated via CT and by using and integrating commercial software (e.g. Velocity2, MSC/PATRAN (ref. 5), and Hypermesh (ref. 6)) is being applied successfully at the NASA Glenn Research Center. The building process from structural modeling to the analysis level is outlined in reference 7. Subsequently, a stress analysis of a composite cooling panel under combined thermomechanical loading conditions was performed to validate this process.

Abdul-Aziz, Ali↗

Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials (Second Annual Progress Report)

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of nuclear reactor parts. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which can introduce internal material flaws, such as pores and anisotropy. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to exposure to high temperature, radiation and corrosive environment in a nuclear reactor. Thermal tomography (TT) provides a capability for non-destructive evaluation of sub-surface defects in arbitrary size structures. Thermal tomography is a computational method for heat diffusion-based imaging of solids, which provides 3D visualization of data from flash thermography measurements. We investigate thermal tomography imaging and nondestructive evaluation of stainless steel and nickel super alloy metallic structures produced with laser powder bed fusion (LPBF) additive manufacturing (AM) process. Metallic structures produced with LPBF contain defects, and there are limited capabilities to evaluate these structures non-destructively. Thermal tomography reconstruction of 3D apparent spatial effusivity provides information about AM structure geometry and internal material flaws. We study performance of thermal tomography in imaging of metallic structures through COMSOL computer simulations of transient heat transfer, and through reconstruction of data obtained from experimental measurements. Reconstruction of internal defects is investigated using a stainless steel 316L specimen with flat bottom hole (FBH) indentations, and Inconel 718 plate produced with laser powder bed fusion (LPBF) method, which contains imprinted hemispherical shape low density regions containing non-sintered metallic powder. The FBH’s have the same sizes as the imprinted defects in the LPBF specimens, but offer better imaging contrast. Thermal tomography reconstructions provide visualizations of internal defects, and allow for estimation of their sizes and locations. Detection sensitivity of TT is limited by noises. We investigate separation of signal from noise in thermography images using several machine learning (ML) methods, including new spatio-temporal blind source separation (STBSS) and spatio-temporal sparse dictionary learning (STSDL) methods. Performance of the ML methods is benchmarked using thermography data obtained from imaging stainless steel 316L and Inconel 718 specimens produced LPBF method with imprinted calibrated porosity defects. The ML methods are ranked by F-score and execution runtime. Finally, we investigate TT of AM stainless steel 316L specimen with imprinted internal porosity defects using relatively low-cost, small form factor infrared (IR) camera based on uncooled micro bolometer detector. Sparse coding related K-means singular value decomposition (SVD) machine learning, image processing algorithms are developed to improve quality of TT images through removal of Additive white Gaussian noise without blurring the images. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact TT can also be used for in-service nondestructive evaluation (NDE). With capability to perform in-service NDE of the AM component lifecycle, TT data can be used for development of a component digital twin.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Robust Spectral Anomaly Detection in EELS Spectral Images via 3D Convolutional Variational Autoencoders

Abstract A 3D Convolutional Variational Autoencoder (3D‐CVAE) is introduced for automated anomaly detection in electron energy‐loss spectroscopy spectrum imaging (EELS‐SI) data. This approach leverages the full 3D structure of EELS‐SI data to detect subtle spectral anomalies while preserving both spatial and spectral correlations across the datacube. By employing cross‐entropy loss and training on bulk spectra, the model learns to reconstruct bulk features characteristic of the defect‐free material. In exploring methods for anomaly detection, both the 3D‐CVAE approach and principal component analysis (PCA) are evaluated, testing their performance using FeL‐edge ΔEpeak shifts designed to simulate material defects. These results show that 3D‐CVAE achieves superior anomaly detection and maintains consistent performance across various shift magnitudes. The method demonstrates clear bimodal separation between bulk and anomalous spectra, enabling reliable classification. Further analysis verifies that lower‐dimensional representations are robust to anomalies in the data. While performance advantages over PCA diminish with decreasing anomaly concentration, our method maintains high reconstruction quality even in challenging, noise‐dominated spectral regions. This approach provides a robust framework for unsupervised automated detection of spectral anomalies in EELS‐SI data, particularly valuable for analyzing complex material systems.

Chemistry↗

A Simple Preparation Method for Full-Range Electron Tomography of Nanoparticles and Fine Powders

Abstract Electron tomography has become a valuable and widely used tool for studying the three-dimensional nanostructure of materials and biological specimens. However, the incomplete tilt range provided by conventional sample holders limits the fidelity and quantitative interpretability of tomographic images by leaving a “missing wedge” of unknown information in Fourier space. Imaging over a complete range of angles eliminates missing wedge artifacts and dramatically improves tomogram quality. Full-range tomography is usually accomplished using needle-shaped samples milled from bulk material with focused ion beams, but versatile specimen preparation methods for nanoparticles and other fine powders are lacking. In this work, we present a new preparation technique in which powder specimens are supported on carbon nanofibers that extend beyond the end of a tungsten needle. Using this approach, we produced tomograms of platinum fuel cell catalysts and gold-decorated strontium titanate photocatalyst specimens. Without the missing wedge, these tomograms are free from elongation artifacts, supporting straightforward automatic segmentation and quantitative analysis of key materials properties such as void size and connectivity, and surface area and curvature. This approach may be generalized to other samples that can be dispersed in liquids, such as biological structures, creating new opportunities for high-quality electron tomography across disciplines.

Materials Science↗

Cone Beam Computed Tomography Image Guidance System for a Dedicated Intracranial Radiosurgery Treatment Unit

Purpose: Image guidance has improved the precision of fractionated radiation treatment delivery on linear accelerators. Precise radiation delivery is particularly critical when high doses are delivered to complex shapes with steep dose gradients near critical structures, as is the case for intracranial radiosurgery. To reduce potential geometric uncertainties, a cone beam computed tomography (CT) image guidance system was developed in-house to generate high-resolution images of the head at the time of treatment, using a dedicated radiosurgery unit. The performance and initial clinical use of this imaging system are described. Methods and Materials: A kilovoltage cone beam CT system was integrated with a Leksell Gamma Knife Perfexion radiosurgery unit. The X-ray tube and flat-panel detector are mounted on a translational arm, which is parked above the treatment unit when not in use. Upon descent, a rotational axis provides 210 Degree-Sign of rotation for cone beam CT scans. Mechanical integrity of the system was evaluated over a 6-month period. Subsequent clinical commissioning included end-to-end testing of targeting performance and subjective image quality performance in phantoms. The system has been used to image 2 patients, 1 of whom received single-fraction radiosurgery and 1 who received 3 fractions, using a relocatable head frame. Results: Images of phantoms demonstrated soft tissue contrast visibility and submillimeter spatial resolution. A contrast difference of 35 HU was easily detected at a calibration dose of 1.2 cGy (center of head phantom). The shape of the mechanical flex vs scan angle was highly reproducible and exhibited <0.2 mm peak-to-peak variation. With a 0.5-mm voxel pitch, the maximum targeting error was 0.4 mm. Images of 2 patients were analyzed offline and submillimeter agreement was confirmed with conventional frame. Conclusions: A cone beam CT image guidance system was successfully adapted to a radiosurgery unit. The system is capable of producing high-resolution images of bone and soft tissue. The system is in clinical use and provides excellent image guidance without invasive frames.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray and Neutron Radiography for Quantitative Material Reconstructions

Radiography is a powerful tool to determine the interior structure of objects. X-ray radiography is widely used and provides high-resolution images, though X-rays have limited transmission through materials of high atomic number (Z) and density. In contrast, neutrons can penetrate many materials that are heavily attenuating to X-rays, such as metals, providing contrast in the inner layers of highly attenuating items. Past work has shown the value in using both X-ray and neutron radiography for estimating material thicknesses, though that work was limited to simulated data. Here, we demonstrate quantitative material reconstructions using experimental X-ray and neutron radiography data from lab-based systems, accurately modeling radiography system responses to within a few percent to enable quantitative measures of material thickness. We demonstrate the utility of neutron radiography and X-ray radiography for these quantitative reconstructions and introduce methods for using their complementarity to improve image quality and optimize experimental design.

Gilbert, Andrew J.↗

Rapid sensing of hidden objects and defects using a single-pixel diffractive terahertz sensor

Abstract Terahertz waves offer advantages for nondestructive detection of hidden objects/defects in materials, as they can penetrate most optically-opaque materials. However, existing terahertz inspection systems face throughput and accuracy restrictions due to their limited imaging speed and resolution. Furthermore, machine-vision-based systems using large-pixel-count imaging encounter bottlenecks due to their data storage, transmission and processing requirements. Here, we report a diffractive sensor that rapidly detects hidden defects/objects within a 3D sample using a single-pixel terahertz detector, eliminating sample scanning or image formation/processing. Leveraging deep-learning-optimized diffractive layers, this diffractive sensor can all-optically probe the 3D structural information of samples by outputting a spectrum, directly indicating the presence/absence of hidden structures or defects. We experimentally validated this framework using a single-pixel terahertz time-domain spectroscopy set-up and 3D-printed diffractive layers, successfully detecting unknown hidden defects inside silicon samples. This technique is valuable for applications including security screening, biomedical sensing and industrial quality control.

Li, Jingxi (ORCID:0000000165958680)↗

AGR-1 UCO Kernel Phase Analysis Imaging Archive

UCO kernels in tri-structural isotropic (TRISO) particles consist of a heterogeneous mixture of uranium oxide and uranium carbide. During the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program, mean kernel composition was specified based on bulk measurements of uranium, oxygen, and carbon content, as well as the resulting O/U, C/U, and O+C/U ratios. Further development of quality control characterization methods has resulted in a method for more direct measurement of phase fractions on a per-kernel basis using optical microscopy of polished kernel cross sections. This report provides benchmark values for this analysis method when applied to kernels from the AGR-1 campaign and to the raw images used.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Three Dimensional Molecular Imaging for Lignocellulosic Materials

The development of high efficiency, inexpensive processing protocols to render biomass components into fermentable substrates for the sequential processing of cell wall components into fuels and important feedstocks for the biorefinery of the future is a key goal of the national roadmap for renewable energy. Furthermore, the development of such protocols depends critically on detailed knowledge of the spatial and temporal infiltration of reagents designed to remove and separate the phenylpropenoid heteropolymer (lignin) from the processable sugar components sequestered in the rigid cell walls of plants. A detailed chemical and structural understanding of this pre-enzymatic processing in space and time was the focus of this program. We worked to develop new imaging strategies that produce real-time molecular speciation information in situ; extract sub-surface information about the effects of processing; and follow the spatial and temporal characteristics of the molecular species in the matrix and correlate this complex profile with saccharification. Spatially correlated SIMS and Raman imaging were used to provide high quality, high resolution subcellular images of Miscanthus cross sections. Furthermore, the combination of information from the mass spectrometry and Raman scattering allows specific chemical assignments of observed structures, difficult to assign from either imaging approach alone and lays the foundation for subsequent heterocorrelated imaging experiments targeted at more challenging biological systems, such as the interacting plant-microbe systems relevant to the rhizosphere.

09 BIOMASS FUELS↗

Synchrotron X-Ray Topography Study of Structural Defects and Strain in Epitaxial Structures of Yb- and Tm-Doped Potassium Rare-Earth Double Tungstates and Their Influence on Laser Performance.

Monoclinic potassium rare-earth double tungstates [KRE(WO{sub 4}){sub 2}, RE = Y, Lu, Yb; KREW] are well suited as hosts for active lanthanide ion (Ln{sup 3+}) dopants for diode-pumped solid-state lasers, with particular interest in thin-disk laser configurations when they are grown as thin films. Using synchrotron white-beam x-ray topography, we have imaged defects and strain in top-seeded solution-grown (TSSG) bulk substrates of different rare-earth tungstates as well as within Yb{sup 3+}- and Tm{sup 3+}-doped epitaxies for thin-disk laser applications grown on these substrates by liquid-phase epitaxy. Higher structural stress in Yb:KYW/KYW epitaxies compared with Yb:KLuW/KLuW epitaxies is found to lower efficiency in laser operation. The quality of Tm:KLuW/KLuW epitaxial films is sensitive to doping level, film thickness, and growth rate. Inhomogeneous stresses within the layers are dominated by lattice-mismatch effects rather than by crystallographic anisotropy.

36 MATERIALS SCIENCE↗

Visible-to-THz near-field nanoscopy

Optical microscopy has a key role in research, development and quality control across a wide range of scientific, technological and medical fields. However, diffraction limits the spatial resolution of conventional optical instruments to about half the illumination wavelength. A technique that surpasses the diffraction limit in the wide spectral range between visible and terahertz frequencies is scattering-type scanning near-field optical microscopy (s-SNOM). The basis of s-SNOM is an atomic force microscope in which the tip is illuminated with light from the visible to the terahertz spectral range. By recording the elastically tip-scattered light while scanning the sample below the tip, s-SNOM yields near-field optical images with a remarkable resolution of 10 nm, simultaneously with the standard atomic force microscopic topography image. This resolution is independent of the illumination wavelength, rendering s-SNOM a versatile nanoimaging and nanospectroscopy technique for fundamental and applied studies of materials, structures and phenomena. This Review presents an overview of the fundamental principles governing the measurement and interpretation of near-field contrasts and discusses key applications of s-SNOM. We also showcase emerging developments that enable s-SNOM to operate under various environmental conditions, including cryogenic temperatures, electric and magnetic fields, electrical currents, strain and liquid environments. Furthermore, all these recent developments broaden the applicability of s-SNOMs for exploring fundamental solid-state and quantum phenomena, biological matter, catalytic reactions and more.

Hillenbrand, Rainer [CIC nanoGUNE BRTA and Departm↗

Rhodium coated mirrors deposited by magnetron sputtering for fusion applications

Metallic mirrors will be essential components of all optical spectroscopy and imaging systems for ITER plasma diagnostics. Any change in the mirror performance, in particular, its reflectivity, due to erosion of the surface by charge exchange neutrals or deposition of impurities will influence the quality and reliability of the detected signals. Due to its high reflectivity in the visible wavelength range and its low sputtering yield, rhodium appears as an attractive material for first mirrors in ITER. However, the very high price of the raw material calls for using it in the form of a film deposited onto metallic substrates. The development of a reliable technique for the preparation of high reflectivity rhodium films is therefore of the highest importance. Rhodium layers with thicknesses of up to 2 {mu}m were produced on different substrates of interest (Mo, stainless steel, Cu) by magnetron sputtering. Produced films exhibit a low roughness and crystallite size of about 10 nm with a dense columnar structure. No impurities were detected on the surface after deposition. Scratch tests demonstrate that adhesion properties increase with substrate hardness. Detailed optical characterizations of Rh-coated mirrors as well as results of erosion tests performed both under laboratory conditions and in the TEXTOR tokamak are presented in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Comprehensive Methodology to Evaluate Losses and Process Variations in Silicon Solar Cell Manufacturing

Novel, high-throughput metrology methods are used in this paper for detailed performance loss analysis of approximately 400 industrial crystalline silicon solar cells, all coming from the same production line. The characterization sequence combines traditional global cell measurements (e.g., current-voltage, Suns-VOC) with camera-based cell imaging of voltage distribution and power dissipation from photoluminescence and lock-in thermography, respectively. Spatial variations in current collection are visualized using a high-speed external quantum efficiency and reflectance measurement technique. A nondestructive transfer length method (TLM) measurement technique is also implemented, featuring circular TLM structures hidden within the busbars of the cells. The variance of individual loss parameters and their impact on cell performance are quantified for this large group of cells. Based on correlations performed across parameters, recombination losses in the bulk and rear surface of the cell are shown to be the primary limiting factor for the cell efficiency. The nature of these distributions and correlations provide important insights about loss mechanisms in industrial solar cells, helping to prioritize efforts for optimizing the performance of the production line. Additionally, many of the parameters extracted from these techniques can be tied back to incoming material quality issues (e.g., poor bulk carrier lifetime, nonuniform wafer doping) and to individual unit processes (e.g., texturing, phosphorus diffusion, silicon nitride deposition, metallization), allowing the data to be used directly for process control in manufacturing. All of the datasets are made available for download.

14 SOLAR ENERGY↗

Fluorescent Applications to Crystallization

By covalently modifying a subpopulation, less than or equal to 1%, of a macromolecule with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification, and tests with model proteins have shown that labeling u to 5 percent of the protein molecules does not affect the X-ray data quality obtained . The presence of the trace fluorescent label gives a number of advantages. Since the label is covalently attached to the protein molecules, it "tracks" the protein s response to the crystallization conditions. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination crystals show up as bright objects against a darker background. Non-protein structures, such as salt crystals, do not show up under fluorescent illumination. Crystals have the highest protein concentration and are readily observed against less bright precipitated phases, which under white light illumination may obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries as the protein or protein structures is all that shows up. Fluorescence intensity is a faster search parameter, whether visually or by automated methods, than looking for crystalline features. Preliminary tests, using model proteins, indicates that we can use high fluorescence intensity regions, in the absence of clear crystalline features or "hits", as a means for determining potential lead conditions. A working hypothesis is that more rapid amorphous precipitation kinetics may overwhelm and trap more slowly formed ordered assemblies, which subsequently show up as regions of brighter fluorescence intensity. Experiments are now being carried out to test this approach using a wider range, of proteins. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons.

Pusey, Marc L.↗

Microscopy modality transfer of steel microstructures: Inferring scanning electron micrographs from optical microscopy using generative AI

Scanning electron microscopy (SEM) is resource intensive, which limits its throughput in some applications. As an alternative, we propose applying computer vision and machine learning to generate high-quality synthetic SEM micrographs from micrographs obtained using light optical microscopy (LOM). Working with a correlated LOM/SEM dataset of dual-phase steel images, we test generative models of various architectures, including encoder-decoder networks, generative adversarial networks (GANs), and diffusion-based models. We find that the diffusion models significantly outperform other methods on both qualitative and quantitative assessments, while preserving key metallurgical meaning. This work establishes diffusion as the state-of-the-art for microscopy modality transfer and demonstrates the potential of AI-powered microscopy to enhance LOM with micron scale structural recreation.

Computer vision↗