Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Solar Flare Physics

We have continued our previous efforts in studies of fourier imaging methods applied to hard X-ray flares. We have performed physical and theoretical analysis of rotating collimator grids submitted to GSFC(Goddard Space Flight Center) for the High Energy Solar Spectroscopic Imager (HESSI). We have produced simulation algorithms which are currently being used to test imaging software and hardware for HESSI. We have developed Maximum-Entropy, Maximum-Likelihood, and "CLEAN" methods for reconstructing HESSI images from count-rate profiles. This work is expected to continue through the launch of HESSI in July, 2000. Section 1 shows a poster presentation "Image Reconstruction from HESSI Photon Lists" at the Solar Physics Division Meeting, June 1998; Section 2 shows the text and viewgraphs prepared for "Imaging Simulations" at HESSI's Preliminary Design Review on July 30, 1998.

Schmahl, Edward J.↗

Ultrafast method for scanning tunneling spectroscopy

A scanning tunneling microscope (STM) combines unique capabilities in imaging and spectroscopy with atomic precision, and it can obtain energy-resolved spectroscopic data with atomic resolution. In this paper, we utilize a recently proposed modification to the STM feedback control loop to acquire high quality d 2 I/dV 2 images. We have developed a constant differential conductance imaging method by closing the STM feedback loop with a high precision dI/dV measurement. In this mode, the tip’s vertical position is adjusted so as to keep the differential conductance constant during raster scanning of the surface. Based on this imaging mode, we propose a new technique to acquire fast and reliable scanning tunneling spectroscopy (STS) data simultaneously with the imaging.

47 OTHER INSTRUMENTATION↗

Elastic Stochastic Full Waveform Inversion (eSFWI)

This collaboration between Lawrence Livermore National Security, LLC (LLNS) as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Chevron USA Inc., acting through its Chevron Technical Center division, aimed at developing next-generation computational methods for the Elastic Stochastic Full Waveform Inversion (eSFWI). Seismic imaging is heavily used in the oil and gas industry for identifying and operating subsurface reservoirs. Improved seismic imaging methods can improve productivity, lower costs, and improve operational and environmental safety. This CRADA demonstrated that new high-performance computing (HPC) architectures being rolled out over the next five years can enable unprecedented seismic imaging resolution when using eSFWI techniques to process active seismic data. An open-source computational mini-application was developed, capable of demonstrating near-peak performance for eSFWI algorithms on CPU and GPU enabled HPC platforms. Performance was demonstrated on LLNL HPC systems such as Lassen, as well as on Chevron systems. This project benefited Chevron USA Inc. by demonstrating the potential computational efficiency of their full waveform inversion capabilities used to characterize oil/gas reservoirs, which in turn benefits the public through potential increases in capabilities to perform analysis of leasing sites.

04 OIL SHALES AND TAR SANDS↗

A model-based scatter artifacts correction for cone beam CT

Purpose: Due to the increased axial coverage of multislice computed tomography (CT) and the introduction of flat detectors, the size of x-ray illumination fields has grown dramatically, causing an increase in scatter radiation. For CT imaging, scatter is a significant issue that introduces shading artifact, streaks, as well as reduced contrast and Hounsfield Units (HU) accuracy. The purpose of this work is to provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. Methods: The method starts with an estimation of coarse scatter profiles for a set of CBCT data in either image domain or projection domain. A denoising algorithm designed specifically for Poisson signals is then applied to derive the final scatter distribution. Qualitative and quantitative evaluations using thorax and abdomen phantoms with Monte Carlo (MC) simulations, experimental Catphan phantom data, and in vivo human data acquired for a clinical image guided radiation therapy were performed. Scatter correction in both projection domain and image domain was conducted and the influences of segmentation method, mismatched attenuation coefficients, and spectrum model as well as parameter selection were also investigated. Results: Results show that the proposed algorithm can significantly reduce scatter artifacts and recover the correct HU in either projection domain or image domain. For the MC thorax phantom study, four-components segmentation yields the best results, while the results of three-components segmentation are still acceptable. The parameters (iteration number K and weight β) affect the accuracy of the scatter correction and the results get improved as K and β increase. It was found that variations in attenuation coefficient accuracies only slightly impact the performance of the proposed processing. For the Catphan phantom data, the mean value over all pixels in the residual image is reduced from −21.8 to −0.2 HU and 0.7 HU for projection domain and image domain, respectively. The contrast of the in vivo human images is greatly improved after correction. Conclusions: The software-based technique has a number of advantages, such as high computational efficiency and accuracy, and the capability of performing scatter correction without modifying the clinical workflow (i.e., no extra scan/measurement data are needed) or modifying the imaging hardware. When implemented practically, this should improve the accuracy of CBCT image quantitation and significantly impact CBCT-based interventional procedures and adaptive radiation therapy.

60 APPLIED LIFE SCIENCES↗

Utilizing Highly Scattered Light for Intelligence through Aerosols

This communication is the final report for the project Utilizing Highly Scattered Light for Intelligence through Aerosols funded by the Laboratory Directed Research and Development (LDRD) program at Sandia National Laboratories and lasting six months in 2019. Aerosols like fog reduce visibility and cause down-time that for critical systems or operations are unacceptable. Information is lost due to the random scattering and absorption of light by tiny particles. Computational diffuse optical imaging methods show promise for interpreting the light transmitted through fog, enabling sensing and imaging to improve situational awareness at depths 10 times greater than current methods. Developing this capability first requires verification and validation of diffusion models of light propagation in fog. For this reason, analytical models were developed and compared to experimental data captured at the Sandia National Laboratory Fog Chamber facility. A methodology was developed to incorporate the propagation of scattered light through the imaging optics to a pixel array. The diffusion approximation to the radiative transfer equation was found to predict light propagation in fog under the appropriate conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multidimensional Processing and Visual Rendering of Complex 3D Biomedical Images

The proposed technology uses advanced image analysis techniques to maximize the resolution and utility of medical imaging methods being used during spaceflight. We utilize COTS technology for medical imaging, but our applications require higher resolution assessment of the medical images than is routinely applied with nominal system software. By leveraging advanced data reduction and multidimensional imaging techniques utilized in analysis of Planetary Sciences and Cell Biology imaging, it is possible to significantly increase the information extracted from the onboard biomedical imaging systems. Year 1 focused on application of these techniques to the ocular images collected on ground test subjects and ISS crewmembers. Focus was on the choroidal vasculature and the structure of the optic disc. Methods allowed for increased resolution and quantitation of structural changes enabling detailed assessment of progression over time. These techniques enhance the monitoring and evaluation of crew vision issues during space flight.

Sams, Clarence F.↗

A new fluorescence/PET probe for targeting intracellular human telomerase reverse transcriptase (hTERT) using Tat peptide-conjugated IgM

Despite an increasing need for methods to visualize intracellular proteins in vivo, the majority of antibody-based imaging methods available can only detect membrane proteins. The human telomerase reverse transcriptase (hTERT) is an intracellular target of great interest because of its high expression in several types of cancer. In this study, we developed a new probe for hTERT using the Tat peptide. An hTERT antibody (IgG or IgM) was conjugated with the Tat peptide, a fluorescence dye and {sup 64}Cu. HT29 (hTERT+) and U2OS (hTERT−) were used to visualize the intracellular hTERT. The hTERT was detected by RT-PCR and western blot. Fluorescence signals for hTERT were obtained by confocal microscopy, live cell imaging, and analyzed by Tissue-FAXS. In nude mice, tumors were visualized using the fluorescence imaging devices Maestro™ and PETBOX. In RT-PCR and western blot, the expression of hTERT was detected in HT29 cells, but not in U2OS cells. Fluorescence signals were clearly observed in HT29 cells and in U2OS cells after 1 h of treatment, but signals were only detected in HT29 cells after 24 h. Confocal microscopy showed that 9.65% of U2OS and 78.54% of HT29 cells had positive hTERT signals. 3D animation images showed that the probe could target intranuclear hTERT in the nucleus. In mice models, fluorescence and PET imaging showed that hTERT in HT29 tumors could be efficiently visualized. In summary, we developed a new method to visualize intracellular and intranuclear proteins both in vitro and in vivo. - Highlights: • We developed new probes for imaging hTERT using Tat-conjugated IgM antibodies labeled with a fluorescent dye and radioisotope. • This probes could be used to overcome limitation of conventional antibody imaging system in live cell imaging. • This system could be applicable to monitor intracellular and intranuclear proteins in vitro and in vivo.

60 APPLIED LIFE SCIENCES↗

Multiresolution Localization with Temporal Scanning for Super-Resolution Diffuse Optical Imaging of Fluorescence

A super-resolution optical imaging method is introduced that relies on the distinct temporal information associated with each fluorescent optical reporter to determine its spatial position to high precision with measurements of heavily scattered light. This multiple-emitter localization approach uses a diffusion equation forward model in a cost function, and has the potential to achieve micron-scale spatial resolution through centimeters of tissue. Utilizing some degree of temporal separation for the reporter emissions, position and emission strength are determined using a computationally efficient time stripping multiresolution algorithm. The method circumvents the spatial resolution challenges faced by earlier optical imaging approaches using a diffusion equation forward model, and is promising for in vivo applications. For example, in principle, the approach could be used to localize individual neurons firing throughout a rodent brain, enabling direct imaging of neural network activity.

42 ENGINEERING↗

Genomes to Structure and Function Workshop Report 2022

The goal of the U.S. Department of Energy (DOE) Biological and Environmental Research (BER) Program is to achieve a predictive understanding of complex biological, earth, and environmental systems with the aim of advancing the nation’s energy and infrastructure security. (https://www.energy.gov/science/ ber/biological-and-environmental-research). To pursue this goal, collaborations among experts in diverse research areas that lead to multidisciplinary projects are indispensable. The roles of DOE’s User Facilities, which offer unique and powerful resources for such research projects, are evolving, and expectations for the facilities are increasing. To respond to Users’ needs, the Joint Genome Institute (JGI) and Environmental Molecular Sciences Laboratory (EMSL) initiated the Facilities Integrating Collaborations for User Science (FICUS) program in 2014. This collaboration has grown into a popular and successful program, advancing more than 100 multidisciplinary projects to date. Similarly, the new interFacility collaborations among the JGI, EMSL, and User resources for BER structural biology and imaging at the Basic Energy Science (BES) Program’s synchrotron and neutron facilities are becoming essential for cutting-edge transdisciplinary science. To further explore the need for the BER research community to combine genomic, functional, and structural approaches to advance their research, an organizing committee was formed to develop and jointly host a 3-part workshop. The committee’s members represented seven DOE National Laboratory User Facilities (Appendix 1 lists the members). The “Genomes to Structure and Function” virtual workshop (see Appendices 2–5) was composed of three sessions. The first session, titled “Molecular Structures” (October 27– 28, 2021), highlighted diverse integrative experimental and computational approaches correlating structural data with sequencing and functional information, as well as predicting protein structures to model complex biological systems. The second session, “Intracellular Organization, and Material Synthesis and Decomposition” (December 15–16, 2021), covered imaging methods for observing, quantifying, and manipulating biosystems. The third session, “Imaging the Rhizosphere and Cellular Organization” (January 26–27, 2022) emphasized advanced and non-invasive imaging techniques applied to plant root-microbe-soil interactions.

59 BASIC BIOLOGICAL SCIENCES↗

Sub-pixel spatial resolution wavefront phase imaging

A phase imaging method for an optical wavefront acquires a plurality of phase images of the optical wavefront using a phase imager. Each phase image is unique and is shifted with respect to another of the phase images by a known/controlled amount that is less than the size of the phase imager's pixels. The phase images are then combined to generate a single high-spatial resolution phase image of the optical wavefront.

Stahl, H. Philip↗

Evaluation of Functional Marrow Irradiation Based on Skeletal Marrow Composition Obtained Using Dual-Energy Computed Tomography

Purpose: To develop an imaging method to characterize and map marrow composition in the entire skeletal system, and to simulate differential targeted marrow irradiation based on marrow composition. Methods and Materials: Whole-body dual energy computed tomography (DECT) images of cadavers and leukemia patients were acquired, segmented to separate bone marrow components, namely, bone, red marrow (RM), and yellow marrow (YM). DECT-derived marrow fat fraction was validated using histology of lumbar vertebrae obtained from cadavers. The fractions of RM (RMF = RM/total marrow) and YMF were calculated in each skeletal region to assess the correlation of marrow composition with sites and ages. Treatment planning was simulated to target irradiation differentially at a higher dose (18 Gy) to either RM or YM and a lower dose (12 Gy) to the rest of the skeleton. Results: A significant correlation between fat fractions obtained from DECT and cadaver histology samples was observed (r=0.861, P<.0001, Pearson). The RMF decreased in the head, neck, and chest was significantly inversely correlated with age but did not show any significant age-related changes in the abdomen and pelvis regions. Conformity of radiation to targets (RM, YM) was significantly dependent on skeletal sites. The radiation exposure was significantly reduced (P<.05, t test) to organs at risk (OARs) in RM and YM irradiation compared with standard total marrow irradiation (TMI). Conclusions: Whole-body DECT offers a new imaging technique to visualize and measure skeletal-wide marrow composition. The DECT-based treatment planning offers volumetric and site-specific precise radiation dosimetry of RM and YM, which varies with aging. Our proposed method could be used as a functional compartment of TMI for further targeted radiation to specific bone marrow environment, dose escalation, reduction of doses to OARs, or a combination of these factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Method of manufacturing image sensor including nanostructure color filter

A method of manufacturing an image sensor includes: preparing a sensor substrate including: a sensor layer including a photosensitive cell; and a signal line layer including lines to receive electric signals from the photosensitive cell; forming a first material layer having a first refractive index on the sensor substrate; and forming a nanopattern layer on the first material layer, the nanopattern layer including a material having a second refractive index different from the first refractive index.

36 MATERIALS SCIENCE↗

Deep Learning for Full Waveform Inversion of Elastic Active-Source Seismic Data to Estimate P-Wave Velocity Models

Seismic imaging methods are critical for Global Security and Energy & Homeland Security missions and activities that rely on subsurface characterization, but traditional methods remain computationally expensive and require significant labor hours and expertise to execute. Within the past few years, machine learning (ML), namely deep learning (DL), has been used to develop data-driven end-to-end full waveform inversion (FWI) methods to estimate 2D P-wave velocity (Vp) models in a fraction of the time as conventional FWI. These methods, however, are trained on simplistic acoustic wave seismic data and Vp models that are not realistic nor representative of real-world observations, leaving a large gap between the state-of-the-art and deployable, feasible, and practical DL FWI methods. Here, we generate a synthetic active-source, 3D, elastic wave seismic data set and a variety of Vp models with realistic geologic structure for training DL FWI methods. We evaluate six different methods that have performed well for acoustic DL FWI or medical imaging tasks using our more realistic dataset. We find that these six trained models do not match the performance of published acoustic end-to-end DL FWI methods, indicating more training data may be needed, physics may need to be incorporated to achieve good accuracy at the sacrifice of the end-to-end advantage, and/or novel methods need to be developed to enable end-to-end DL FWI methods to perform well for real-world seismic data.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Imaging extended single crystal lattice distortion fields with multi-peak Bragg ptychography

Recent advances in phase-retrieval-based x-ray imaging methods have demonstrated the ability to reconstruct 3D distortion vector fields within a nanocrystal by using coherent diffraction information from multiple crystal Bragg reflections. However, these works do not provide a solution to the challenges encountered in imaging lattice distortions in crystals with significant defect content that result in phase wrapping. Moreover, these methods only apply to isolated crystals smaller than the x-ray illumination, and therefore cannot be used for imaging of distortions in extended crystals. We introduce multi-peak Bragg ptychography which addresses both challenges via an optimization framework that combines stochastic gradient descent and phase unwrapping methods for robust image reconstruction of lattice distortions and defects in extended crystals. Our work uses modern automatic differentiation toolsets so that the method is easy to extend to other settings and easy to implement in high-performance computers. This work is particularly timely given the broad interest in using the increased coherent flux in fourth-generation synchrotrons for innovative material research.

36 MATERIALS SCIENCE↗

Quantitative analysis of breast echotexture patterns in automated breast ultrasound images

Purpose: Breast tissue composition is considered to be associated with breast cancer risk. This study aimed to develop a computer-aided classification (CAC) system to automatically classify echotexture patterns as heterogeneous or homogeneous using automated breast ultrasound (ABUS) images. Methods: A CAC system was proposed that can recognize breast echotexture patterns in ABUS images. For each case, the echotexture pattern was assessed by two expert radiologists and classified as heterogeneous or homogeneous. After neutrosophic image transformation and fuzzy c-mean clusterings, the lower and upper boundaries of the fibroglandular tissues were defined. Then, the number of hypoechoic regions and histogram features were extracted from the fibroglandular tissues, and the support vector machine model with the leave-one-out cross-validation method was utilized as the classifier. The authors’ database included a total of 208 ABUS images of the breasts of 104 females. Results: The accuracies of the proposed system for the classification of heterogeneous and homogeneous echotexture patterns were 93.48% (43/46) and 92.59% (150/162), respectively, with an overall Az (area under the receiver operating characteristic curve) of 0.9786. The agreement between the radiologists and the proposed system was almost perfect, with a kappa value of 0.814. Conclusions: The use of ABUS and the proposed method can provide quantitative information on the echotexture patterns of the breast and can be used to evaluate whether breast echotexture patterns are associated with breast cancer risk in the future.

60 APPLIED LIFE SCIENCES↗

Multilevel segmentation of intracranial aneurysms in CT angiography images

Purpose: Segmentation of aneurysms plays an important role in interventional planning. Yet, the segmentation of both the lumen and the thrombus of an intracranial aneurysm in computed tomography angiography (CTA) remains a challenge. This paper proposes a multilevel segmentation methodology for efficiently segmenting intracranial aneurysms in CTA images. Methods: The proposed methodology first uses the lattice Boltzmann method (LBM) to extract the lumen part directly from the original image. Then, the LBM is applied again on an intermediate image whose lumen part is filled by the mean gray-level value outside the lumen, to yield an image region containing part of the aneurysm boundary. After that, an expanding disk is introduced to estimate the complete contour of the aneurysm. Finally, the contour detected is used as the initial contour of the level set with ellipse to refine the aneurysm. Results: The results obtained on 11 patients from different hospitals showed that the proposed segmentation was comparable with manual segmentation, and that quantitatively, the average segmentation matching factor (SMF) reached 86.99%, demonstrating good segmentation accuracy. Chan–Vese method, Sen’s model, and Luca’s model were used to compare the proposed method and their average SMF values were 39.98%, 40.76%, and 77.11%, respectively. Conclusions: The authors have presented a multilevel segmentation method based on the LBM and level set with ellipse for accurate segmentation of intracranial aneurysms. Compared to three existing methods, for all eleven patients, the proposed method can successfully segment the lumen with the highest SMF values for nine patients and second highest SMF values for the two. It also segments the entire aneurysm with the highest SMF values for ten patients and second highest SMF value for the one. This makes it potential for clinical assessment of the volume and aspect ratio of the intracranial aneurysms.

60 APPLIED LIFE SCIENCES↗

Multimodal photon and neutron imaging devices with fast event-by-event multisampling readout and optimized particle type discrimination

A particle imaging method for distinguishing between types of incident particles, such as neutrons, photons, and alphas, and improving the position resolution of particle imaging devices with matrix readout. The method includes high frequency multisampling readout electronics that provides the sequences of multiple measurements for each detected event, resulting in recorded detailed waveform information describing the signals. Such detailed information is used to approximate each signal waveform with a parameterized function in which the extracted parameter sets determine the type of the incident particle in an optimized fashion. The detailed event-by-event multisampling information for each signal readout channel in the matrix readout of the radiation imaging devices improves and optimizes the position resolution for variable shapes of the signals. Such devices can be used in mixed radiation fields, creating a new class of multimodal photon and neutron imagers.

Degtiarenko, Pavel V.↗

SU-F-T-469: A Clinically Observed Discrepancy Between Image-Based and Log- Based MLC Position

Purpose: To present a clinical case which challenges the base assumption of log-file based QA, by showing that the actual position of a MLC leaf can suddenly deviate from its programmed and logged position by >1 mm as observed with real-time imaging. Methods: An EPID-based exit-fluence dosimetry system designed to prevent gross delivery errors was used in cine mode to capture portal images during treatment. Visual monitoring identified an anomalous MLC leaf pair gap not otherwise detected by the automatic position verification. The position of the erred leaf was measured on EPID images and log files were analyzed for the treatment in question, the prior day’s treatment, and for daily MLC test patterns acquired on those treatment days. Additional standard test patterns were used to quantify the leaf position. Results: Whereas the log file reported no difference between planned and recorded positions, image-based measurements showed the leaf to be 1.3±0.1 mm medial from the planned position. This offset was confirmed with the test pattern irradiations. Conclusion: It has been clinically observed that log-file derived leaf positions can differ from their actual positions by >1 mm, and therefore cannot be considered to be the actual leaf positions. This cautions the use of log-based methods for MLC or patient quality assurance without independent confirmation of log integrity. Frequent verification of MLC positions through independent means is a necessary precondition to trusting log file records. Intra-treatment EPID imaging provides a method to capture departures from MLC planned positions. Work was supported in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗