Image Analysis Method for Quantifying Snow Losses on PV Systems.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Monte Carlo simulation methods are widely used in medical physics research and are starting to be implemented in clinical applications such as radiation therapy planning systems. Monte Carlo simulations offer the capability to accurately estimate quantities of interest that are challenging to measure experimentally while taking into account the realistic anatomy of an individual patient. Traditionally, practical application of Monte Carlo simulation codes in diagnostic imaging was limited by the need for large computational resources or long execution times. However, recent advancements in high-performance computing hardware, combined with a new generation of Monte Carlo simulation algorithms and novel postprocessing methods, are allowing for the computation of relevant imaging parameters of interest such as patient organ doses and scatter-to-primaryratios in radiographic projections in just a few seconds using affordable computational resources. Programmable Graphics Processing Units (GPUs), for example, provide a convenient, affordable platform for parallelized Monte Carlo executions that yield simulation times on the order of 10{sup 7} xray/ s. Even with GPU acceleration, however, Monte Carlo simulation times can be prohibitive for routine clinical practice. To reduce simulation times further, variance reduction techniques can be used to alter the probabilistic models underlying the x-ray tracking process, resulting in lower variance in the results without biasing the estimates. Other complementary strategies for further reductions in computation time are denoising of the Monte Carlo estimates and estimating (scoring) the quantity of interest at a sparse set of sampling locations (e.g. at a small number of detector pixels in a scatter simulation) followed by interpolation. Beyond reduction of the computational resources required for performing Monte Carlo simulations in medical imaging, the use of accurate representations of patient anatomy is crucial to the virtual generation of medical images and accurate estimation of radiation dose and other imaging parameters. For this, detailed computational phantoms of the patient anatomy must be utilized and implemented within the radiation transport code. Computational phantoms presently come in one of three format types, and in one of four morphometric categories. Format types include stylized (mathematical equation-based), voxel (segmented CT/MR images), and hybrid (NURBS and polygon mesh surfaces). Morphometric categories include reference (small library of phantoms by age at 50th height/weight percentile), patient-dependent (larger library of phantoms at various combinations of height/weight percentiles), patient-sculpted (phantoms altered to match the patient's unique outer body contour), and finally, patient-specific (an exact representation of the patient with respect to both body contour and internal anatomy). The existence and availability of these phantoms represents a very important advance for the simulation of realistic medical imaging applications using Monte Carlo methods. New Monte Carlo simulation codes need to be thoroughly validated before they can be used to perform novel research. Ideally, the validation process would involve comparison of results with those of an experimental measurement, but accurate replication of experimental conditions can be very challenging. It is very common to validate new Monte Carlo simulations by replicating previously published simulation results of similar experiments. This process, however, is commonly problematic due to the lack of sufficient information in the published reports of previous work so as to be able to replicate the simulation in detail. To aid in this process, the AAPM Task Group 195 prepared a report in which six different imaging research experiments commonly performed using Monte Carlo simulations are described and their results provided. The simulation conditions of all six cases are provided in full detail, with all necessary data on material composition, source, geometry, scoring and other parameters provided. The results of these simulations when performed with the four most common publicly available Monte Carlo packages are also provided in tabular form. The Task Group 195 Report will be useful for researchers needing to validate their Monte Carlo work, and for trainees needing to learn Monte Carlo simulation methods. In this symposium we will review the recent advancements in highperformance computing hardware enabling the reduction in computational resources needed for Monte Carlo simulations in medical imaging. We will review variance reduction techniques commonly applied in Monte Carlo simulations of medical imaging systems and present implementation strategies for efficient combination of these techniques with GPU acceleration. Trade-offs involved in Monte Carlo acceleration by means of denoising and “sparse sampling” will be discussed. A method for rapid scatter correction in cone-beam CT (<5 min/scan) will be presented as an illustration of the simulation speeds achievable with optimized Monte Carlo simulations. We will also discuss the development, availability, and capability of the various combinations of computational phantoms for Monte Carlo simulation of medical imaging systems. Finally, we will review some examples of experimental validation of Monte Carlo simulations and will present the AAPM Task Group 195 Report. Learning Objectives: Describe the advances in hardware available for performing Monte Carlo simulations in high performance computing environments. Explain variance reduction, denoising and sparse sampling techniques available for reduction of computational time needed for Monte Carlo simulations of medical imaging. List and compare the computational anthropomorphic phantoms currently available for more accurate assessment of medical imaging parameters in Monte Carlo simulations. Describe experimental methods used for validation of Monte Carlo simulations in medical imaging. Describe the AAPM Task Group 195 Report and its use for validation and teaching of Monte Carlo simulations in medical imaging.
We introduce a coded-mask-based multi-contrast imaging method for high-resolution phase-contrast and dark-field imaging. The method uses a binary phase mask designed to provide an ultra-high-contrast pattern and reference-free single-shot measurement and an algorithm based on maximum-likelihood optimization and automatic differentiation to perform simultaneous reconstruction of absorption, phase, and dark-field object images. Further, we demonstrate that the method has great potential for real-time quantitative phase imaging and wavefront sensing when combined with deep learning.
Given a grey-intensity image, our method detects the optimal threshold for a suitable binarization of MR brain images. In MR brain image processing, the grey levels of pixels belonging to the object are not substantially different from the grey levels belonging to the background. Threshold optimization is an effective tool to separate objects from the background and further, in classification applications. This paper gives a detailed investigation on the selection of thresholds. Our method does not use the well-known method for binarization. Instead, we perform a simple threshold optimization which, in turn, will allow the best classification of the analyzed images into healthy and multiple sclerosis disease. The dissimilarity (or the distance between classes) has been established using the clustering method based on dendrograms. We tested our method using two classes of images: the first consists of 20 T2-weighted and 20 proton density PD-weighted scans from two healthy subjects and from two patients with multiple sclerosis. For each image and for each threshold, the number of the white pixels (or the area of white objects in binary image) has been determined. These pixel numbers represent the objects in clustering operation. The following optimum threshold values are obtained, T = 80 for PD images and T = 30 for T2w images. Each mentioned threshold separate clearly the clusters that belonging of the studied groups, healthy patient and multiple sclerosis disease.
One of the attractive image segmentation methods is the Active Contour Model (ACM) which has been widely used in medical imaging as it always produces sub-regions with continuous boundaries. Intravascular ultrasound (IVUS) is a catheter based medical imaging technique which is used for quantitative assessment of atherosclerotic disease. Two methods of ACM realizations are presented in this paper. The gradient descent flow based on minimizing energy functional can be used for segmentation of IVUS images. However this local operation alone may not be adequate to work with the complex IVUS images. The first method presented consists of basically combining the local geodesic active contours and global region-based active contours. The advantage of combining the local and global operations is to allow curves deforming under the energy to find only significant local minima and delineate object borders despite noise, poor edge information and heterogeneous intensity profiles. Results for this algorithm are compared to standard techniques to demonstrate the method's robustness and accuracy. In the second method, the energy function is appropriately modified and minimized using a Hopfield neural network. Proper modifications in the definition of the bias of the neurons have been introduced to incorporate image characteristics. The method overcomes distortions in the expected image pattern, such as due to the presence of calcium, and employs a specialized structure of the neural network and boundary correction schemes which are based on a priori knowledge about the vessel geometry. The presented method is very fast and has been evaluated using sequences of IVUS frames.
Purpose: Visualization of anatomical structures using radiological imaging methods is an important tool in medicine to differentiate normal from pathological tissue and can generate large amounts of data for a radiologist to read. Integrating these large data sets is difficult and time-consuming. A new approach uses both supervised and unsupervised advanced machine learning techniques to visualize and segment radiological data. This study describes the application of a novel hybrid scheme, based on combining wavelet transform and nonlinear dimensionality reduction (NLDR) methods, to breast magnetic resonance imaging (MRI) data using three well-established NLDR techniques, namely, ISOMAP, local linear embedding (LLE), and diffusion maps (DfM), to perform a comparative performance analysis. Methods: Twenty-five breast lesion subjects were scanned using a 3T scanner. MRI sequences used were T1-weighted, T2-weighted, diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE) imaging. The hybrid scheme consisted of two steps: preprocessing and postprocessing of the data. The preprocessing step was applied for B{sub 1} inhomogeneity correction, image registration, and wavelet-based image compression to match and denoise the data. In the postprocessing step, MRI parameters were considered data dimensions and the NLDR-based hybrid approach was applied to integrate the MRI parameters into a single image, termed the embedded image. This was achieved by mapping all pixel intensities from the higher dimension to a lower dimensional (embedded) space. For validation, the authors compared the hybrid NLDR with linear methods of principal component analysis (PCA) and multidimensional scaling (MDS) using synthetic data. For the clinical application, the authors used breast MRI data, comparison was performed using the postcontrast DCE MRI image and evaluating the congruence of the segmented lesions. Results: The NLDR-based hybrid approach was able to define and segment both synthetic and clinical data. In the synthetic data, the authors demonstrated the performance of the NLDR method compared with conventional linear DR methods. The NLDR approach enabled successful segmentation of the structures, whereas, in most cases, PCA and MDS failed. The NLDR approach was able to segment different breast tissue types with a high accuracy and the embedded image of the breast MRI data demonstrated fuzzy boundaries between the different types of breast tissue, i.e., fatty, glandular, and tissue with lesions (>86%). Conclusions: The proposed hybrid NLDR methods were able to segment clinical breast data with a high accuracy and construct an embedded image that visualized the contribution of different radiological parameters.
Purpose: To test two new techniques, the distance-of-closest approach (DCA) and Compton line (CL) filters, developed as a means of improving the spatial resolution of Compton camera (CC) imaging. Methods: Gammas emitted from {sup 22}Na, {sup 137}Cs, and {sup 60}Co point sources were measured with a prototype 3-stage CC. The energy deposited and position of each interaction in each stage were recorded and used to calculate a “cone-of-origin” for each gamma that scattered twice in the CC. A DCA filter was developed which finds the shortest distance from the gamma’s cone-of-origin surface to the location of the gamma source. The DCA filter was applied to the data to determine the initial energy of the gamma and to remove “bad” interactions that only contribute noise to the image. Additionally, a CL filter, which removes gamma events that do not follow the theoretical predictions of the Compton scatter equation, was used to further remove “bad” interactions from the measured data. Then images were reconstructed with raw, unfiltered data, DCA filtered data, and DCA+CL filtered data and the achievable image resolution of each dataset was compared. Results: Spatial resolutions of ∼2 mm, and better than 2 mm, were achievable with the DCA and DCA+CL filtered data, respectively, compared to > 5 mm for the raw, unfiltered data. Conclusion: In many special cases in medical imaging where information about the source position may be known, such as proton radiotherapy range verification, the application of the DCA and CL filters can result in considerable improvements in the achievable spatial resolutions of Compton imaging.
Here, the enigma of how a metaphase chromosome is constructed remains unclear with the higher order structure still under investigation. It is clear that this is a 3D structural problem requiring the development of new technologies necessary to answer this long standing mystery. This mini-review highlights new and recent, advanced 3D imaging methods that have been used to image mitotic human chromosomes. These 3D methods have advantages and limitations that are both discussed, Furthermore chromosome sample preparation and future imaging directions are also highlighted.
Purpose: To develop and validate an automated technique for evaluating the spatial resolution characteristics of clinical computed tomography (CT) images. Methods: Twenty one chest and abdominopelvic clinical CT datasets were examined in this study. An algorithm was developed to extract a CT resolution index (RI) analogous to the modulation transfer function from clinical CT images by measuring the edge-spread function (ESF) across the patient’s skin. A polygon mesh of the air-skin boundary was created. The faces of the mesh were then used to measure the ESF across the air-skin interface. The ESF was differentiated to obtain the line-spread function (LSF), and the LSF was Fourier transformed to obtain the RI. The algorithm’s ability to detect the radial dependence of the RI was investigated. RIs measured with the proposed method were compared with a conventional phantom-based method across two reconstruction algorithms (FBP and iterative) using the spatial frequency at 50% RI, f{sub 50}, as the metric for comparison. Three reconstruction kernels were investigated for each reconstruction algorithm. Finally, an observer study was conducted to determine if observers could visually perceive the differences in the measured blurriness of images reconstructed with a given reconstruction method. Results: RI measurements performed with the proposed technique exhibited the expected dependencies on the image reconstruction. The measured f{sub 50} values increased with harder kernels for both FBP and iterative reconstruction. Furthermore, the proposed algorithm was able to detect the radial dependence of the RI. Patient-specific measurements of the RI were comparable to the phantom-based technique, but the patient data exhibited a large spread in the measured f{sub 50}, indicating that some datasets were blurrier than others even when the projection data were reconstructed with the same reconstruction algorithm and kernel. Results from the observer study substantiated this finding. Conclusions: Clinically informed, patient-specific spatial resolution can be measured from clinical datasets. The method is sufficiently sensitive to reflect changes in spatial resolution due to different reconstruction parameters. The method can be applied to automatically assess the spatial resolution of patient images and quantify dependencies that may not be captured in phantom data.
Purpose: To validate a correlation coefficient template-matching algorithm applied to the supervised automated quantification of abdominal-pelvic organ motion captured on time-resolved magnetic resonance imaging. Methods and Materials: Magnetic resonance images of 21 patients across four anatomic sites were analyzed. Representative anatomic points of interest were chosen as surrogates for organ motion. The point of interest displacements across each image frame relative to baseline were quantified manually and through the use of a template-matching software tool, termed 'Motiontrack.' Automated and manually acquired displacement measures, as well as the standard deviation of intrafraction motion, were compared for each image frame and for each patient. Results: Discrepancies between the automated and manual displacements of {>=}2 mm were uncommon, ranging in frequency of 0-9.7% (liver and prostate, respectively). The standard deviations of intrafraction motion measured with each method correlated highly (r = 0.99). Considerable interpatient variability in organ motion was demonstrated by a wide range of standard deviations in the liver (1.4-7.5 mm), uterus (1.1-8.4 mm), and prostate gland (0.8-2.7 mm). The automated algorithm performed successfully in all patients but 1 and substantially improved efficiency compared with manual quantification techniques (5 min vs. 60-90 min). Conclusion: Supervised automated quantification of organ motion captured on magnetic resonance imaging using a correlation coefficient template-matching algorithm was efficient, accurate, and may play an important role in off-line adaptive approaches to intrafraction motion management.
Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [{sup 11}C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.
Purpose: To explore the pattern of metastasis to retropharyngeal lymph nodes (RLN) and its relationship with tumor range in nasopharyngeal carcinoma (NPC) patients by using magnetic resonance imaging. Methods and Materials: Magnetic resonance images of 618 NPC patients were reviewed. Nodes were classified as metastatic on the basis of size criteria, the presence of nodal necrosis, and extracapsular spread. Results: A total of 597 involved RLN were detected in 392 patients (63.4%). The sites of RLN metastasis included occipital bone, 37 (6.2%); first cervical vertebra (C1), 453 (75.9%); second cervical vertebra (C2), 104 (17.4%); and third cervical vertebra (C3), 3 (0.5%). The incidence of RLN involvement was less than that of Level IIb node involvement (72.2% vs. 86.5%) in 543 patients with lymphadenopathy. The incidence of RLN metastasis was significantly higher in cases of parapharyngeal space invasion or involvement of Level II, Level III, Level IV, and/or Level V nodes and significantly lower in N0 and Stage I disease. Conversely, the incidence of RLN metastasis did not differ significantly among T1, 2, 3, and 4 disease or among Stage II, III, and IV disease. Conclusions: Level IIb nodes, rather than RLN, seem to be the first-echelon nodes in NPC. The incidence of RLN metastasis decreases steadily from level C1 to level C3. Retropharyngeal lymph node metastasis correlates well with involvement of the parapharyngeal space and metastases to Level II, III, IV, and/or V nodes but not with T stage.
Purpose: To evaluate the reproducibility of tumor motion probability distribution function (PDF) in stereotactic body radiation therapy (SBRT) of lung cancer using cine megavoltage (MV) images. Methods and Materials: Cine MV images of 20 patients acquired during three-dimensional conformal (6-11 beams) SBRT treatments were retrospectively analyzed to extract tumor motion trajectories. For each patient, tumor motion PDFs were generated per fraction (PDF{sub n}) using three selected 'usable' beams. Patients without at least three usable beams were excluded from the study. Fractional PDF reproducibility (R{sub n}) was calculated as the Dice similarity coefficient between PDF{sub n} to a 'ground-truth' PDF (PDF{sub g}), which was generated using the selected beams of all fractions. The mean of R{sub n}, labeled as R{sub m}, was calculated for each patient and correlated to the patient's mean tumor motion rang (A{sub m}). Change of R{sub m} during the course of SBRT treatments was also evaluated. Intra- and intersubject coefficient of variation (CV) of R{sub m} and A{sub m} were determined. Results: Thirteen patients had at least three usable beams and were analyzed. The mean of R{sub m} was 0.87 (range, 0.84-0.95). The mean of A{sub m} was 3.18 mm (range, 0.46-7.80 mm). R{sub m} was found to decrease as A{sub m} increases following an equation of R{sub m} = 0.17e{sup -0.9Am} + 0.84. R{sub m} also decreased slightly throughout the course of treatments. Intersubject CV of R{sub m} (0.05) was comparable to intrasubject CV of R{sub m} (range, 0.02-0.09); intersubject CV of A{sub m} (0.73) was significantly greater than intrasubject CV of A{sub m} (range, 0.09-0.24). Conclusions: Tumor motion PDF can be determined using cine MV images acquired during the treatments. The reproducibility of lung tumor motion PDF decreased exponentially as the tumor motion range increased and decreased slightly throughout the course of the treatments.
Purpose: The purpose of this study was to prospectively investigate clinical correlations between dosimetric parameters associated with radiation pneumonitis (RP) and functional lung imaging. Methods and Materials: Functional lung imaging was performed using four-dimensional computed tomography (4D-CT) for ventilation imaging, single-photon emission computed tomography (SPECT) for perfusion imaging, or both (V/Q-matched region). Using 4D-CT, ventilation imaging was derived from a low attenuation area according to CT numbers below different thresholds (vent-860 and -910). Perfusion imaging at the 10th, 30th, 50th, and 70th percentile perfusion levels (F10-F70) were defined as the top 10%, 30%, 50%, and 70% hyperperfused normal lung, respectively. All imaging data were incorporated into a 3D planning system to evaluate correlations between RP dosimetric parameters (where fV20 is the percentage of functional lung volume irradiated with >20 Gy, or fMLD, the mean dose administered to functional lung) and the percentage of functional lung volume. Radiation pneumonitis was evaluated using Common Terminology Criteria for Adverse Events version 4.0. Statistical significance was defined as a P value of <.05. Results: Sixty patients who underwent curative radiation therapy were enrolled (48 patients for non-small cell lung cancer, and 12 patients for small cell lung cancer). Grades 1, 2, and ≥3 RP were observed in 16, 44, and 6 patients, respectively. Significant correlations were observed between the percentage of functional lung volume and fV20 (r=0.4475 in vent-860 and 0.3508 in F30) or fMLD (r=0.4701 in vent-860 and 0.3128 in F30) in patients with grade ≥2 RP. F30∩vent-860 results exhibited stronger correlations with fV20 and fMLD in patients with grade ≥2 (r=0.5509 in fV20 and 0.5320 in fMLD) and grade ≥3 RP (r=0.8770 in fV20 and 0.8518 in fMLD). Conclusions: RP dosimetric parameters correlated significantly with functional lung imaging.
SUMMARY As the high-frequency analogue to field-scale earthquakes, acoustic emissions (AEs) provide a valuable complement to study rock deformation mechanisms. During the load-stepping creep experiments with CO2-saturated water injection into a basaltic sample from Carbfix site in Iceland, 8791 AE events are detected by at least one of the seven piezoelectric sensors. Here, we apply a cross-correlation-based source imaging method, called geometric-mean reverse-time migration (GmRTM) to locate those AE events. Besides the attractive picking-free feature shared with other waveform-based methods (e.g. time-reversal imaging), GmRTM is advantageous in generating high-resolution source images with reduced imaging artefacts, especially for experiments with relatively sparse receivers. In general, the imaged AE locations are found to be scattered across the sample, suggesting a complicated fracture network rather than a well-defined major shear fracture plane, in agreement with X-ray computed tomography imaging results after retrieval of samples from the deformation apparatus. Clustering the events in space and time using the nearest-neighbour approach revealed a group of ‘repeaters’, which are spatially co-located over an elongated period of time and likely indicate crack, or shear band growth. Furthermore, we select 2196 AE events with high signal-to-noise-ratio (SNR) and conduct moment tensor estimation using the adjoint (backpropagated) strain tensor fields at the locations of AE sources. The resulting AE locations and focal mechanisms support our previously assertion that creep of basalt at the experimental conditions is accommodated dominantly by distributed microcracking.
Purpose: To develop and apply an observer model to objectively evaluate and compare the performance of different angiographic imaging equipment and acquisition variables. Methods: Image Acquisition— Iodine-based phantoms were created with target diameters: 0.5, 1, 2, and 4 mm. The phantoms were imaged using both planes of a bi-plane angiography system with detector pixel dimensions 0.1542 mm{sup 2} and 0.1842 mm{sup 2}, respectively. All four phantoms were imaged with magnification factors 1.5, 1.25 and 1 and with the large and small focal spots. Phantom position and the dose per frame (0.12– 0.24 μ Gy/frame) were varied for a single phantom size, magnification and focal spot. Observer Model— For each experimental condition, 1200 signal-present and signal-absent images were acquired and a detectability index (d') was calculated with a Gabor-channelized Hotelling observer (CHO) model. Detectability indices were evaluated as a function of dose, phantom size, and magnification. The model was then applied to compare d' of the two imaging planes and focal spots. Uncertainty in d' was estimated by bootstrapping the data and by examining the shift-variance of systems. Results: Detectability indices varied linearly with magnification and the square root of dose. For the 2 and 4 mm phantoms, d' varied linearly with diameter. For the 0.5 and 1 mm phantoms, d' expectedly deviated from this linear relationship due to substantial detector and focal spot blurring of the phantoms. The small focal spot yielded up to 50% greater d' values than the large focal spot. For the two detectors, differences in d' did not exceed the estimated ∼7% error. Conclusions: The detectability indices predictably scaled with dose, diameter, magnification, and focal spot size and serve to validate the model. Results demonstrate statistically similar target detectability for both investigated detectors, despite differences in pixel dimensions. This CHO model provides a framework to evaluate angiographic system performance.