Search NASA⌕ Search

SEARCH · Search NASA

Results for “impulse test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Direct Laser Impulse (DLI) System Alignment: Requirements Engineering Project

The National Ignition Facility (NIF) is the world’s largest and most energetic laser, and it is comprised of 192 laser beams that must align onto one target for the purpose of learning about Internal Confinement Fusion (ICF) and High Energy Density (HED) physics. A new NIF capability under development is the Direct Laser Impulse (DLI). The DLI capability will provide a test environment where high pulsed laser energy is delivered to a three-dimensional target. Achieving this delivery to target relies on a precision alignment and positioning of the two redirected NIF beams, as shown in Figure 1. When aligned, the two combined beams—with a frequency converted from infrared (IR) to green laser light, at a fluence (energy per unit area) of roughly 20 joules per square centimeter—will be capable of delivering up to 30 kilojoules of direct, unfocused energy to a one cubic foot target. The 40-cm x 40-cm aligned impulse area at the DLI target interaction plane (TIP) is achieved by using a beam path comprised of pickoff and transport mirrors, frequency conversion crystals, optics serving as environmental barriers, and debris shields. A separate aligned diagnostic beam path is also required for impulse to TIP characterization. Final in-situ alignment is required for the two populated diverted NIF beam paths onto the DLI target as well as the diagnostic optical beam path. Existing NIF alignment subsystems do not offer references that meet DLI’s unique demand. The new DLI Red Box, which has been designed to allow for alignment, has been shown to require deviation from the intended configuration and operational use case to obtain adequate functionality. A systems engineering evaluation has identified a solution that meets the stakeholder requirements while optimizing key performance parameters. The solution, referred to in this document as the Red Box “+” Rotated, was determined to be an improved version of the current DLI Red Box. This system offers improved system repeatability and alignment stability while maintaining similar interfaces and decreasing the demand for engineer/operator interaction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operating characteristics of the Russian D-55 thruster with anode layer

Performance measurements of a Russian engineering-model Thruster with Anode Layer (TAL) were obtained as part of a program to evaluate the operating characteristics of Russian Hall-thruster technology. The TAL model D-55 was designed to operate in the 1-2 kW power range on xenon. When received, the thruster had undergone only a few hours of acceptance testing by the manufacturer. Direct thrust measurements were obtained at a background pressure of 0.0003 Pa (2 x 10(exp -6) torr) at power levels ranging from 0.3 kW to 2.1 kW. At the nominal power level of 1.3 kW, a specific impulse level of 1600 s with a corresponding efficiency of 0.48 was attained. At all flow rates tested, the efficiency increased linearly with specific impulse until a maximum was reached, and then the efficiency leveled off. Increasing the anode flow rate shifted the efficiency upward, reaching 0.50 at 1850 s specific impulse. The thruster was equipped with inner and outer electromagnets which were isolated from the discharge and from each other. Variation of the magnetic field, obtained by changing the currents through the magnets, had little effect on performance, except at current levels below 70 percent of nominal. For a given operating condition, the performance was slightly affected by facility pressure. As the pressure was increased by a factor of thirty to 0.008 Pa (6 x 10(exp -5) torr), the current steadily increased by 4 percent, and the thrust increased by 2 percent. Performance comparisons were made with the Stationary Plasma Thruster, and the efficiency and specific impulse values were similar at power levels ranging from 0.9 kW to 1.5 kW. Endurance testing was not performed, and comparisons of lifetime were not made.

Sankovic, John M.↗

Effect of 670-nm Light-Emitting Diode Light On Neuronal Cultures

Light close to and within the near infrared range has documented benefits for promoting wound healing in human and animal studies. Our preliminary results using light-emitting diodes (LEDs) in this range have also demonstrated two-to five-fold increases in growth-phase-specific DNA synthesis in normal fibroblasts, muscle cells, osteoblasts, and mucosal epithelial cells in tissue cultures. However, the mechanisms of action of such light on cells are poorly understood. We hypothesized that the therapeutic effects of such light result from the stimulation of cellular events associated with increases in cytochrome oxidase activity. As a first step in testing our hypothesis, we subjected primary neuronal cultures to impulse blockade by tetrodotoxin (TTX), a voltage-dependent sodium channel blocker, and applied LED light at 670 nm to determine if it could partially or fully reverse the reduction of cytochrome oxidase activity by TTX. The wavelength and parameters were previously tested to be beneficial for wound healing.

Wong-Riley, Margaret T. T.↗

Performance and lifetime assessment of MPD arc thruster technology

A summary of performance and lifetime characteristics of pulsed and steady-state magnetoplasmadynamic (MPD) thrusters is presented. The technical focus is on cargo vehicle propulsion for exploration-class missions to the Moon and Mars. Relatively high MPD thruster efficiencies of 0.43 and 0.69 have been reported at about 5000 s specific impulse using hydrogen and lithium, respectively. Efficiencies of 0.10 to 0.35 in the 1000 to 4500 s specific impulse range have been obtained with other propellants (e.g., Ar, NH3, N2). Thermal efficiency data in excess of 0.80 at MW power levels using pulsed thrusters indicate the potential of high MPD thruster performance. Extended tests of pulsed and steady-state MPD thrusters yield total impulses at least two to three orders of magnitude below that necessary for cargo vehicle propulsion. Performance tests and diagnostics for life-limiting mechanisms of megawatt-class thrusters will require high fidelity test stands which handle in excess of 10 kA and a vacuum facility whose operational pressure is less than 3 x 10 to the -4 torr.

Sovey, James S.↗

Performance and lifetime assessment of MPD arc thruster technology

A summary of performance and lifetime characteristics of pulsed and steady-state magnetoplasmadynamic (MPD) thrusters is presented. The technical focus is on cargo vehicle propulsion for exploration-class missions to the Moon and Mars. Relatively high MPD thruster efficiencies of 0.43 and 0.69 have been reported at about 5000 s specific impulse using hydrogen and lithium, respectively. Efficiencies of 0.10 to 0.35 in the 1000 to 4500 s specific impulse range have been obtained with other propellants (e.g., Ar, NH3, N2). Thermal efficiency data in excess of 0.80 at MW power levels using pulsed thrusters indicate the potential of high MPD thruster performance. Extended tests of pulsed and steady-state MPD thrusters yield total impulses at least two to three orders of magnitude below that necessary for cargo vehicle propulsion. Performance tests and diagnostics for life-limiting mechanisms of megawatt-class thrusters will require high fidelity test stands which handle in excess of 10 kA and a vacuum facility whose operational pressure is less than 3 x 10 to the -4 torr.

Sovey, James S.↗

Transient excitation and data processing techniques employing the fast fourier transform for aeroelastic testing

The development of testing techniques useful in airplane ground resonance testing, wind tunnel aeroelastic model testing, and airplane flight flutter testing is presented. Included is the consideration of impulsive excitation, steady-state sinusoidal excitation, and random and pseudorandom excitation. Reasons for the selection of fast sine sweeps for transient excitation are given. The use of the fast fourier transform dynamic analyzer (HP-5451B) is presented, together with a curve fitting data process in the Laplace domain to experimentally evaluate values of generalized mass, model frequencies, dampings, and mode shapes. The effects of poor signal to noise ratios due to turbulence creating data variance are discussed. Data manipulation techniques used to overcome variance problems are also included. The experience is described that was gained by using these techniques since the early stages of the SST program. Data measured during 747 flight flutter tests, and SST, YC-14, and 727 empennage flutter model tests are included.

Jennings, W. P.↗

Results of a 1462 hour ammonia arcjet endurance test

A total of 1462 hours of operaton were demonstrated in an endurance test of a 30 kWe-class ammonia arcjet operated at 10 kWe. The propellant flow rate was 0.170 g/s, and the measured performance increased from approximately 650 s specific impulse at 36 percent efficiency at the beginning of the test to 675 s at 39 percent near the end. The voltage increased and the current dropped slightly over the first 400 hours, and then remained approximately constant for the remainder of the test. The test, scheduled for 1500 hours, was terminated after an insulator in the rear of the engine failed. Post-test examination of the electrodes revealed only minimal damage. Although there was evidence of a number of mass transport processes occurring in the discharge chamber, the primary life-limiting wear mechanisms appear to be cathode tip erosion and constrictor melting.

Polk, J. E.↗

Flight Performance of a Spin-Stabilized 20-Inch-Diameter Solid-Propellant Spherical Rocket Motor

A successful flight test of a spin-stabilized 20-inch-diameter solid-propellant rocket motor having a propellant mass fraction of 0.92 has been made. The motor was fired at altitude after being boosted by a three-stage test vehicle. Analysis of the data indicates that a total impulse of 44,243 pound-second with a propellant specific impulse of approximately 185 was achieved over a total action time of about 12 seconds. These results are shown to be in excellent agreement with data from ground static firing tests of these motors. The spherical rocket motor with an 11-pound payload attained a velocity of 15,620 feet per second (m = 16.7) with an incremental velocity increase for the spherical motor stage of 12,120 feet per second.

Levine, Jack↗

Electro-impulse de-icing - A status report

The advantages and disadvantages of the Electro-Impulse De-Icing (EIDI) system are examined. The design and operation of the EIDI are described. The effect of repeated impulsive loads on the structure and skin of the aircraft surface is investigated. It is observed that the wing skin directly over the coil receives the greatest stresses. Data from the testing of metal leading edges reveal that after 11,500 impulses cracks appear in the sheet brackets attaching the ribs to the coil beams. The composite leading edge was evaluated for fatigue, and after 20,000 impulses no cracks were detected. The advantages of the band-aid coil mount are discussed.

Zumwalt, G. W.↗

Development of a radioisotope-fueled thruster for satellite propulsion.

Description of the design and testing of two distinct thrustor concepts which use ammonia propellant and have a specific impulse as high as 310 sec during pulsed operation. Considerations of thrustor design, material selection, and system testing are discussed in the light of performance, lifetime, and nuclear safety requirements. Results of a detailed study of the advantages and disadvantages of the use of such a thrustor are presented.

Rosen, S. G.↗

Proven, long-life hydrogen/oxygen thrust chambers for space station propulsion

The development of the manned space station has necessitated the development of technology related to an onboard auxiliary propulsion system (APS) required to provide for various space station attitude control, orbit positioning, and docking maneuvers. A key component of this onboard APS is the thrust chamber design. To develop the required thrust chamber technology to support the Space Station Program, the NASA Lewis Research Center has sponsored development programs under contracts with Aerojet TechSystems Company and with Bell Aerospace Textron Division of Textron, Inc. During the NASA Lewis sponsored program with Aerojet TechSystems, a 25 lb sub f hydrogen/oxygen thruster has been developed and proven as a viable candidate to meet the needs of the Space Station Program. Likewise, during the development program with Bell Aerospace, a 50 lb sub f hydrogen/oxygen Thrust Chamber has been developed and has demonstrated reliable, long-life expectancy at anticipated space station operating conditions. Both these thrust chambers were based on design criteria developed in previous thruster programs and successfully verified in experimental test programs. Extensive thermal analyses and models were used to design the thrusters to achieve total impulse goals of 2 x 10 to the 6th power lb sub f-sec. Test data for each thruster will be compared to the analytical predictions for the performance and heat transfer characteristics. Also, the results of thrust chamber life verification tests will be presented.

Richter, G. P.↗

Thermodynamic Vent System Performance Testing with Subcooled Liquid Methane and Gaseous Helium Pressurant

Due to its high specific impulse and favorable thermal properties for storage, liquid methane (LCH4) is being considered as a candidate propellant for exploration architectures. In order to gain an -understanding of any unique considerations involving micro-gravity pressure control with LCH4, testing was conducted at the Marshall Space Flight Center using the Multipurpose Hydrogen Test Bed (MHTB) to evaluate the performance of a spray-bar thermodynamic vent system (TVS) with subcooled LCH4 and gaseous helium (GHe) pressurant. Thirteen days of testing were performed in November 2006, with total tank heat leak conditions of about 715 W and 420 W at a fill level of approximately 90%. The TVS system was used to subcool the LCH4 to a liquid saturation pressure of approximately 55.2 kPa before the tank was pressurized with GHe to a total pressure of 165.5 kPa. A total of 23 TVS cycles were completed. The TVS successfully controlled the ullage pressure within a prescribed control band but did not maintain a stable liquid saturation pressure. This was likely. due to a TVS design not optimized for this particular propellant and test conditions, and possibly due to a large artificially induced heat input directly into the liquid. The capability to reduce liquid saturation pressure as well as maintain it within a prescribed control band, demonstrated that the TVS could be used to seek and maintain a desired liquid inlet temperature for an engine (at a cost of propellant lost through the TVS vent). One special test was conducted at the conclusion of the planned test activities. Reduction of the tank ullage pressure by opening the Joule-Thomson valve (JT) without operating the pump was attempted. The JT remained open for over 9300 seconds, resulting in an ullage pressure reduction of 30 kPa. The special test demonstrated the feasibility of using the JT valve for limited ullage pressure reduction in the event of a pump failure.

Flachbart, R. H.↗

High-Speed Visualization of Spray Breakup and Velocity Estimation in a Rotating Detonation Combustor Using Laser Induced Fluorescence

The underlying physical processes that liquid fuel sprays undergo in rotating detonation engines, particularly breakup and combustion, are not well understood nor are the coupling effects between the detonation and the spray. In this work, a single liquid jet of liquid fuel is inserted into a hydrogen-air RDC in order to study repetitive-one way coupled detonation interactions. High speed laser induced fluorescence of Jet-A at 300 kHz is used to visualize the dynamic processes inside the RDC for up to 10 ms per test. The employed imaging schemes allowed for unique insight into the spreading of liquid fuel in the azimuthal-axial directions via volumetric laser illumination. The Jet-A velocity field was estimated using OpenOpticalFlow and the impulse events observed colloquially agree with prior work on this test platform.

Instrumentation↗

High-Speed Visualization of Spray Breakup and Velocity Estimation in a Rotating Detonation Combustor Using Laser Induced Fluorescence

The underlying physical processes that liquid fuel sprays undergo in rotating detonation engines, particularly breakup and combustion, are not well understood nor are the coupling effects between the detonation and the spray. In this work, a single liquid jet of liquid fuel is inserted into a hydrogen-air RDC in order to study repetitive-one way coupled detonation interactions. High speed laser induced fluorescence of Jet-A at 300 kHz is used to visualize the dynamic processes inside the RDC for up to 10 ms per test. The employed imaging schemes allowed for unique insight into the spreading of liquid fuel in the azimuthal-axial directions via volumetric laser illumination. The Jet-A velocity field was estimated using OpenOpticalFlow and the impulse events observed colloquially agree with prior work on this test platform.

Instrumentation↗

Some results of the testing of a full-scale Ogee tip helicopter rotor; acoustics, loads, and performance

Full-scale tests were utilized to investigate the effect of the Ogee tip on helicopter rotor acoustics, performance, and loads. Two facilities were used for this study: the Langley whirl tower and a UH-1H helicopter. The test matrix for hover on the whirl tower involved thrust values from 0 to 44,480 N (10,000 lbs) at several tip Mach numbers for both standard and Ogee rotors. The full-scale testing on the UH-1H encompassed the major portion of the flight envelope for that aircraft. Both near-field acoustic measurements as well as far-field flyover data were obtained for both the Ogee and standard rotors. Data analysis of the whirl-tower test shows that the Ogee tip does significantly diffuse the tip vortex while providing some improvement in hover performance. Flight testing of both rotors indicates that the strong impulsive noise signature of the standard rotor can be reduced with the Ogee rotor. Forward flight performance was significantly improved with the Ogee configuration for a large number of flight conditions. Further, rotor control loads and vibrations were reduced through use of this advanced tip rotor.

Mantay, W. R.↗

Evaluation of the annoyance due to helicopter rotor noise

A program was conducted in which 25 test subjects adjusted the levels of various helicopter rotor spectra until the combination of the harmonic noise and a broadband background noise was judged equally annoying as a higher level of the same broadband noise spectrum. The subjective measure of added harmonic noise was equated to the difference in the two levels of broadband noise. The test participants also made subjective evaluations of the rotor noise signatures which they created. The test stimuli consisted of three degrees of rotor impulsiveness, each presented at four blade passage rates. Each of these 12 harmonic sounds was combined with three broadband spectra and was adjusted to match the annoyance of three different sound pressure levels of broadband noise. Analysis of variance indicated that the important variables were level and impulsiveness. Regression analyses indicated that inclusion of crest factor improved correlation between the subjective measures and various objective or physical measures.

Sternfeld, H., Jr.↗

Full-scale testing of an Ogee tip rotor

Full scale tests were utilized to investigate the effect of the ogee tip on helicopter rotor acoustics, performance, and loads. Two facilities were used: the Langley whirl tower and a UH-1H helicopter. The text matrix for hover on the whirl tower involved thrust values from 0 to 44 480 N (10,000 lb) at several tip Mach numbers for both standard and Ogee rotors. The full scale testing on the UH-1H encompassed the major portion of the flight envelope for that aircraft. Both near field acoustic measurements and far field flyover data were obtained for both the ogee and standard rotors. Data analysis of the whirl tower test shows that the ogee tip does significantly diffuse the tip vortex while providing some improvement in hover performance at low and moderate thrust coefficients. Flight testing of both rotors indicates that the strong impulsive noise signature of the standard rotor can be reduced with the ogee rotor. Analysis of the spectra indicates a reduction in energy in the 250 Hz and 1000 Hz range for the ogee rotor. Forward flight performance was significantly improved with the ogee configuration for a large number of flight conditions. Further, rotor control loads were reduced through use of this advanced tip rotor.

Mantay, W. R.↗