Incorporation of Thermal Hydraulic Models for Thermal Power Dispatch into a PWR Power Plant Simulator

This report describes the development, modeling, and results of a generic pressurized water reactor power plant simulator that incorporates coupled electrical and thermal power dispatch to an industrial process located approximately one kilometer from the nuclear power plant. The simulator is a commercial PWR simulator that has been modified to include thermal power dispatch as described in past milestone reports [ , ]. The commercial PWR simulator is a generic simulator available from GSE SYSTEMS® (Sykesville, MD, USA) that is built using RELAP5-HDTM Real-Time Solution and in-house software developed by GSE Systems. This generic PWR (GPWR) simulator performs real-time simulation of the complete power plant from the reactor neutronics to the electricity generation and distribution. All primary, secondary, and auxiliary systems are modeled including all control logic in order to provide the most accurate representation of actual nuclear power plant (NPP) operation, and the simulator results have been rigorously verified by an actual NPP operating at approximately 1 GWe. This report is a continuation of worked performed in previous years, and supplemental information from previous reports is included in the appendix for reference.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Surface Charge Distribution Mapping Using an Electrostatic Probe

Undesired accumulation of charge on dielectric materials causing electrostatic discharges can be an issue in pulsed power systems and electrical systems in general. As such, an understanding of surface charge distribution, charge accumulation, and decay is required. An in-house no-contact electrostatic probe designed with a 2 mm resolution was fabricated to measure and map surface charge distribution. Designed as a contactless instrument, the probe consisting of a metal rod and low leakage amplifier circuit probes the electric potential near the surface. A scan of the surface then provides the raw data, a potential distribution. The actual probe response - i.e., the surface charge to voltage transfer function, is accounted for in post-processing. This is accomplished via an Inverse Wien Filter - a technique often applied in image processing - to deconvolve the probe response from the measured data. A commercially available electrostatic probe, the Trek 341B meter with a 3455ET probe, capable of measuring +/- 20 kV was compared to the in- house probe that is designed to cover a wider range from +/- 35 kV. A resolution better than the simple probe resolution is achieved through the distribution’s scanning voltage method and deconvolution. Applying repeated scans, surface charge decay was tracked on various polymer materials to determine the material and environment dependence; materials included were PA6, PTFE, and others. As an example of material dependence, samples charged to 20 kV at 65% humidity experience full charge decay in approximately 45 seconds for PA5 (152 mm dia.), while it took about 100 times longer for PTFE (51 mm dia.) to observe the same decay/redistribution of charge.

36 MATERIALS SCIENCE↗

Experimental Investigation of Polymer Induced Fouling of Heater Tubes in the First-Ever Polymer Flood Pilot on Alaska North Slope

Mineral fouling in heat exchangers has been extensively investigated by researchers in recent times. The oil and gas industry has a long history of fouling issues in production systems as a result of produced fluids treatment. Due to decline in production rates in oilfields new technologies are being developed and field tested in pilots. Polymer flooding is one such technology that involves addition of polymers to injection fluids to enhance oil production. A polymer flood pilot has been set up in the Schrader Bluff viscous oil reservoir at Milne Point field on the Alaska North Slope (ANS). The results from the pilot are encouraging, however a major concern of the operator is the influence of polymer on the production system after breakthrough, especially the fouling in heat exchangers. This study investigates the propensity of polymer fouling on the heater tubes as a function of different variables, with the ultimate goal of determining safe and efficient operating conditions. This work applies a multi-experimental approach to study the severity of polymer-induced fouling in both dynamic and static states of produced fluids as well as studying the stability of polymer solutions at different temperatures. A unique experimental setup was designed and developed in-house to simulate the fouling process on the heating tube. The influence of heating tube skin temperature, tube material, and polymer concentration on fouling tendency was investigated. Each test was run five times with the same tube, and in each run, the freshly prepared synthetic brine and polymer solution was heated from 77°F to 122°F to mimic field-operating conditions. The heating time and fouling amount were recorded for each run. Dynamic Scale Loop (DSL) tests were conducted to study fouling due to polymer at different temperatures (165°F to 350°F) in a dynamic state of fluid flow where the fluids mimic the residence time of fluids in the heat exchanger on the field pilot. Cloud point measurement has also been conducted to find the critical temperature at which the polymer in solution becomes unstable and precipitates out. The morphology and composition of the deposit samples were analyzed by environmental scanning electron microscopy (ESEM) and X-ray diffraction (XRD), respectively. It was found that the presence of polymer in produced fluids would aggravate the fouling issues on both carbon steel and stainless-steel surfaces at all tested skin temperatures. Only higher skin temperatures of 250°F and 350°F could cause polymer-induced fouling issues on the copper tube surface, and the fouling tendency increased with polymer concentration. At the lower skin temperatures of 165°F, no polymer-induced fouling was identified on the copper tube. A critical temperature that is related to the cloud point of the polymer solution was believed to exist, below which polymer-induced fouling would not occur, and only mineral scale was deposited but above which the polymer would aggravate the fouling issue. The cloud point of the tested polymer solution was determined to be between 220°F and 230°F. In the DSL tests it was found that at higher skin temperatures of 250°F and 350°F tube blocking was observed in the DSL tests whereas the tests at 165°F and 200°F did not show any tube blocking in the same time period. These experiments also manifested the influence of cloud point of the solution as deposit rate increased significantly in both carbon steel and stainless-steel tubes when the skin temperature was higher than the solution cloud point. The results of this study have provided guidance to the operator for the field-operations.

Dhaliwal, Anshul↗

Temperature Dependence of Band Gap Renormalization in High-T Sensor Materials via First-Principles and Experimental Corroboration

Understanding the temperature dependence of functional properties of high-T gas sensing materials is vital for their applications in combustion environments. The electron-phonon coupling that derives the electronic structure change with temperatures is a key property of interest as it affects other sensing responses. Herein, we assess the temperature dependence of band gap renormalization in metal oxides and perovskites by employing Allen-Heine-Cardona theory with first-principles simulations and corroborate with experimental observation. The calculated temperature-dependent band gap changes of these materials studied are in good agreement with in-house experimental data, proving that the theory can adequately predict renormalization on the band gap in the system of interest. The predicted and measured band gap variations are characterized using an analytical model, which can provide useful insights on the simulated zero-temperature band gaps. Based on the available data, a set of 53 metal oxides and perovskites were identified as potential high-T gas sensors. A machine learning model has been developed to predict the band-gap change by capturing the overall trend of the empirical parameters with respect to a reduced feature obtained by transforming the set of available physical features.

Park, Jongwoo↗

Technology Enablers for Advanced Gasoline Compression Ignition Engines

To meet current emission regulations and increasingly demanding global fleet CO2 standards on fuel economy and future trends towards life cycle GHG emissions, advanced combustion engines remain significant in the passenger vehicle sector to achieve high efficiency and low emissions over the full operating range. Lean burn gasoline compression ignition (GCI) technology has shown to have the most potential in reaching these goals, although it faces challenges in the operating range. In this study, an advanced GCI engine is considered with the capability to operate under two combustion modes, namely low temperature combustion (LTC) and GCI. They are enabled with the use of two Hyundai in-house developed technologies; an advanced valve control mechanism known as continuously variable valve duration (CVVD) and a high-pressure gasoline injection system. At low load, the engine utilizes dual CVVD and dual CVVT (continuously variable valve timing) mechanisms for both intake and exhaust valvetrains to enable NVO (negative valve overlap) to trap hot residuals. The hot residuals enable low load auto-ignition, and the phasing control of that auto-ignition is achieved by varying the degrees of NVO, and in turn, the amount of hot residuals. This is done in real time with respect to the changes in engine loads or operating conditions, significantly improving cylinder-phasing control in LTC mode, and subsequently is able to realize a fuel economy gain and reduced emission benefits. Early direct injection during NVO or intake stroke is used to form homogenous or quasi-homogenous air-fuel mixture for LTC. At mid to high loads, late direct injection of gasoline or GCI mode is employed to take advantage of the high volatility and high resistance to auto-ignition of gasoline fuel, so that diesel-engine like high combustion efficiency can be achieved with lower soot emissions for the same NOx level as diesel combustion. In this paper, the key control and fueling technologies that enable this multiple mode combustion are introduced, and the resultant analysis on engine test and CFD simulation at LTC and GCI operating conditions are presented in detail.

Gasoline compression ignition, low temperature com↗

Conceptual design of inverted core lead bismuth eutectic fast reactor for marine applications

The development of an inverted core fast reactor aims to generate 60 MWth for about 30 Effective Full Power Years without refueling. The reactor design is a transportable reactor using UO{sub 2} fuel and lead-bismuth-eutectic cooled designed for marine applications and is intended to improve the reactor performances compared to the normal core design: better condition for passive cooling system capability by lower core pressure drop, taking advantage of potential power uprate from the lower maximum fuel temperature. Systematic design processes are presented in this work: fuel pin geometry selection, fuel assembly (FA) design, and core design. A relationship between pressure drops, coolant velocity, maximum fuel temperature, coolant channel diameter, and fuel volume fraction was introduced in a single graph used as a tool to select fuel pin geometry. Fuel fabrication capability also took place in consideration of FA design which led to 7 holes per FA, and two-dimensional temperature distribution studies were also carried out. Core design processes including radial zoning, axial zoning, and core optimization were conducted using Monte Carlo code MCS, which is UNIST CORE laboratory in-house code. The current core design uses 3 fuel enrichment levels and 3 FA types to control the local power distribution and power shift during its lifetime. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Feasibility of lead-bismuth-cooled fast reactor with fuel shuffling strategy

This paper investigates the feasibility of fuel shuffling of the Advanced Nitride-fueled Simplified 100 MWe (ANTS-100e) Lead-bismuth-cooled Fast Reactor (LFR). The preliminary design has the active core of 235 cm in diameter and 100 cm high. The core is composed of 138 hexagonal fuel assemblies enclosed with a 15-15Ti steel duct. The core adopts the onion zoning with the two zones of low-enriched uranium for a better breeding capability to maximize the first cycle length to 10 effective full-power years (EFPYs). The fuel shuffling study is performed by using the UNIST in-house Monte Carlo code MCS. The neutronic parameters such as the multiplication factor and burnup are being investigated. The fuel shuffling strategy is evaluated through several loading patterns for flattening radial power distribution. It is also found that the core with fuel shuffling could lengthen the core lifetime by more than 5 EFPYs without introducing fresh fuel. Thus, it appears that the ANTS-100e can be principally designed to have the second cycle with another 10 EFPYs if introducing fresh fuel into the core. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Carbon Fiber and Polymer Composites

Tooling is an integral part of composites manufacturing. Composite tools, also called ‘soft’ tools, are more easily constructed than ‘hard’ metal tools and, because they are made from materials similar to the manufactured composite part, they can be made in-house and have a good co-efficient of thermal expansion match. However, as the ‘soft’ designation suggests, they are more vulnerable to wear and typically find application in relatively low-volume production. Additive manufacturing of thermoplastics has proven to be a lucrative option that can help improve the tooling functionalities, as it offers more design flexibility. Owing to the inherent nature of additive manufacturing, the possibility of printing sensors within the tool material and at proximity to otherwise inaccessible areas of the tool become a reality. Continuous carbon fiber (CCF)-reinforced three-dimensional (3D) printing of engineering thermoplastics has proven to be a viable option to strengthen a part well beyond the ideal moduli of unmodified thermoplastic. Furthermore, adding nanotubes or graphene to the thermoplastic matrix will also improve both the thermal conductivity and interlaminar shear strength within the tool. Carbon nanotubes (CNTs) and carbon fibers (CFs) are microwave susceptors; exploiting the physics of Joule heating to increase the energy efficiency of tool hardening and cure rates is a core goal of this project. Because of the rapid volumetric heating enabled by the absorption of microwave or radio frequency energy and electromagnetic (EM) annealing presents an attractive opportunity to significantly reduce manufacturing cycle times while improving part performance.

Craps, Matthew G.↗

Development of creep resistant ferritic-martensitic steels for operation at 650°C

Creep resistant ferritic-martensitic steels capable of operating at 650°C have long been under development for electricity generation. This presentation will showcase the design and development of alloys CPJ-7 and JMP with approximately 420,000 h of in-house creep testing, the equivalent of ~50 years of cumulative creep tests. Approximately fifty different alloy compositions were manufactured as part of an ICME approach. CPJ-7 present superior creep properties compared to COST alloys for steam turbine and P91/92 for boiler applications. The prolonged creep life was attributed to slowing down the destabilization of fine precipitates at 650°C. The JMP steels were designed with higher Co for solid solution strengthening and increased W for matrix strength and stability. The creep life compared to CPJ-7 increased between 118 and 150% at 650°C depending on the stress. On a Larson-Miller plot, the performance of the JMP steels surpasses that of MARBN steel. Composition-microstructure-properties relationships will be discussed.

Detrois, Martin↗

EVs@Scale Lab Consortium High-Power Charging Pillar Deep-Dive Technical Meeting

Managed under the the U.S. Department of Energy (DOE)-funded EVs@Scale Consortium, the High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project aims to create an experimental platform for integration and control approaches in a direct current (DC), distribution-based high-power charging (HPC) system. The eCHIP project addresses the crucial need to design and validate efficient, low-cost, reliable, and interoperable solutions for a DC-coupled charging hub ("DC hub" for short). This report explains the design, development, and implementation process of an experimental platform for the DC hub. DC distribution holds significant potential for enhancing the operation of an HPC station architecture. However, there are challenges in establishing a DC hub, including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and a lack of common system-level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products, as well as novel, in-house designed solutions, to evaluate different use cases at rated power and voltage levels. The developed proof-of-concept charging platform and open-source SEMS allow the development and testing of various controllers and chargers from different vendors. The DC hub platform integrated EVs, an ESS, a PV system, and building load to demonstrate the flexibility of the platform. The open-source SEMS controlled the devices within the hub using a rule-based implementation, realizing available standards.

ADVANCED PROPULSION SYSTEMS↗

A COUPLED DETERMINISTIC TRANSPORT CALCULATION IN COMSOL USING PROPER ORTHOGONAL DECOMPOSITION

A coupled physics problem consisting of radiation transport and heat transfer was modeled using COMSOL Multiphysics to simulate a criticality accident. Reduced order models (ROM) were created to accelerate the radiation transport calculation through Proper Orthogonal Decomposition (POD). Additionally, on-the-fly neutron cross sections were generated from a non-linear function through a feed forward neural network. The Livelink for MATLAB module allowed for data transfer between an otherwise independent solver and in-house modules. A data driven approach to POD was developed to act as a surrogate model to couple with heat transfer, with the POD module written in MATLAB coupled to an isolated heat transfer solve in COMSOL. A coupled transient solution resulted in a good approximation of the flux and temperature, with the maximum error being 3E-2 and 2.5E-3 respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

APPLICATION OF OBJECTIVES-DRIVEN ASSURANCE CASES TO SYSTEM DEVELOPMENT IN AN EVOLVING ACQUISITION MODEL

System properties such as “safety” and “dependability” cannot, in practice, be proven, and must be argued in an “assurance case” aimed at supporting risk-acceptance decisions that have to be made by system acquirers and/or regulatory authorities. The paper is concerned with applications of the “assurance case” idea early in design and development of new systems, when (apart from dedicated testing) the only available operating experience information derives from previous (non-identical) systems. Much of the discussion is based on an evolving acquisition model at the US National Aeronautics and Space Administration; previously, most major systems were developed in-house, but some major systems will now be developed by and acquired from commercial providers. Key points discussed include the following. (1) By promoting a particular kind of focused discussion between acquirers and providers, the use of assurance cases should be particularly valuable under the new acquisition model. (2) In principle, objectives-driven (sometimes called “performance-based”) approaches to assurance of performance have significant advantages in cases where they are applicable. (3) For truly novel systems, completeness of the safety analysis is a significant issue; it is important for the assurance case to include a commitment by the provider (or applicant) to seriously pursue analysis of operating experience, so that previously unrecognized hazards can be identified and addressed. (4) Inquiries into major accidents often point to deficiencies in management oversight in all parts of the life cycle; management processes need to be addressed in the formulation and the implementation of an assurance case. Under the new acquisition model, these considerations imply a serious reconsideration of the way in which the development process is managed by both providers and acquirers.

99 GENERAL AND MISCELLANEOUS↗

Application of Objectives-Driven Assurance Cases to System Development in an Evolving Acquisition Model

System properties such as “safety” and “dependability” cannot, in practice, be proven, and must be argued in an “assurance case” aimed at supporting risk-acceptance decisions that have to be made by system acquirers and/or regulatory authorities. The paper is concerned with applications of the “assurance case” idea early in design and development of new systems, when (apart from dedicated testing) the only available operating experience information derives from previous (non-identical) systems. Much of the discussion is based on an evolving acquisition model at the US National Aeronautics and Space Administration; previously, most major systems were developed in-house, but some major systems will now be developed by and acquired from commercial providers. Key points discussed include the following. (1) By promoting a particular kind of focused discussion between acquirers and providers, the use of assurance cases should be particularly valuable under the new acquisition model. (2) In principle, objectives-driven (sometimes called “performance-based”) approaches to assurance of performance have significant advantages in cases where they are applicable. (3) For truly novel systems, completeness of the safety analysis is a significant issue; it is important for the assurance case to include a commitment by the provider (or applicant) to seriously pursue analysis of operating experience, so that previously unrecognized hazards can be identified and addressed. (4) Inquiries into major accidents often point to deficiencies in management oversight in all parts of the life cycle; management processes need to be addressed in the formulation and the implementation of an assurance case. Under the new acquisition model, these considerations imply a serious reconsideration of the way in which the development process is managed by both providers and acquirers.

99 GENERAL AND MISCELLANEOUS↗

Power Module Precursors and Prognostics

This project focuses on finding and utilizing electrical properties (precursors) of power electronic devices and modules whose changes have strong correlations with different modes and levels of degradations in order to realize online and lightweight state of health evaluation and fault diagnosis. Results from this project will contribute to higher safety, reliability, and power density of power electronic components. The approaches mainly include reviewing academic literature and industry practices for state of the art precursor identification and extraction, accelerated life cycles (ALC) of various power modules to create different degradations in-house, and developing techniques for gate-driver-integratable precursor detection circuit. In FY24, the results includes two sets of definitively detected aging precursors (on-state resistance and gate threshold voltage) for two sets of power modules respectively, controlled accelerated lifetime cycling of multiple silicon carbide (SiC) metal-oxide-semiconductor field-effect transistor (MOSFET) modules, and the development and validation of a gate voltage detection system.

ADVANCED PROPULSION SYSTEMS↗

Replacement of Legacy Analytical Codes at the Advanced Test Reactor

For each operating cycle of the Advanced Test Reactor (ATR) at Idaho National Laboratory, a Core Safety Assurance Package (CSAP) is necessary to demonstrate compliance with the safety basis approved by the United State Department of Energy (DOE). Certain computer codes are used in CSAP development, most of them developed in-house. This work describes replacement of a large set of these codes and updates previous work. Replacement of legacy codes is necessary due to computer hardware failure but also has generally improved user-friendliness.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimentation on Finned-Tube Microchannel Heat Exchanger Incorporating Phase Change Material and R-410A

Integrating latent heat thermal energy storage, particularly phase change materials (PCM), in building heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems, offers substantial benefits for peak load shifting and energy efficiency. While numerous studies explore PCM-embedded heat exchangers (PCM-HX) using single-phase heat transfer fluids, there needs to be more investigation regarding PCM-HX utilizing two-phase refrigerant flow. This gap is even more pronounced for microchannel heat exchanger (MCHX) configurations. In this study, an MCHX-based PCM-HX was built and tested to analyze and evaluate the performance of a PCM-HX operating with a two-phase refrigerant as the working fluid. A commercially available MCHX condenser unit was embedded with 2.6 kg of RT35 PCM and tested using R-410A as the working fluid, using an in-house test loop to control the refrigerant inlet conditions precisely. Thin and minimally invasive T-type thermocouples traced the temperature evolution along MCHX channels and tube banks. Additional larger T-type thermocouple probes at the refrigerant inlet and outlet measured the average power of the PCM-HX during condensing tests, ranging from 0.7 kW to 1.6 kW based on mass flow rates varying from 3.5 g/s to 8 g/s. This experimental study on MCHX-based PCM-HX with a two-phase refrigerant has the potential to offer practical design guidelines for the direct integration of PCM-TES in HVAC&R systems without the use of a secondary loop, while caution is advised to avoid a substantial increase in the refrigerant charge amount.

42 ENGINEERING↗

Replacement of Legacy Analytical Codes at the Advanced Test Reactor

For each operating cycle of the Advanced Test Reactor (ATR) at Idaho National Laboratory, a Core Safety Assurance Package (CSAP) is necessary to demonstrate compliance with the safety basis approved by the United State Department of Energy (DOE). Certain computer codes are used in CSAP development, most of them developed in-house. This work describes replacement of a large set of these codes and updates previous work. Replacement of legacy codes is necessary due to computer hardware failure but also has generally improved user-friendliness.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗