Magnetohydrodynamic Augmented Propulsion Experiment: I. Performance Analysis and Design

The performance of conventional thermal propulsion systems is fundamentally constrained by the specific energy limitations associated with chemical fuels and the thermal limits of available materials. Electromagnetic thrust augmentation represents one intriguing possibility for improving the fuel composition of thermal propulsion systems, thereby increasing overall specific energy characteristics; however, realization of such a system requires an extremely high-energy-density electrical power source as well as an efficient plasma acceleration device. This Technical Publication describes the development of an experimental research facility for investigating the use of cross-field magnetohydrodynamic (MHD) accelerators as a possible thrust augmentation device for thermal propulsion systems. In this experiment,a 1.5-MW(sub e) Aerotherm arc heater is used to drive a 2-MW(sub e) MHD accelerator. The heatsink MHD accelerator is configured as an externally diagonalized, segmented channel, which is inserted into a large-bore, 2-T electromagnet. The performance analysis and engineering design of the flow path are described as well as the parameter measurements and flow diagnostics planned for the initial series of test runs.

Litchford, R. J.↗

Parametric Study of a Mixer/Ejector Nozzle with Mixing Enhancement Devices

A numerical study employing a simplified model of the High Speed Civil Transport mixer/ejector nozzle has been conducted to investigate the effect of tabs (vortex generators) on the mixing process. More complete mixing of the primary and secondary flows within the confined ejector lowers peak exit velocity resulting in reduced jet noise. Tabs were modeled as vortex pairs and inserted into the computational model. The location, size, and number of tabs were varied and its effect on the mixing process is presented here both quantitatively and qualitatively. A baseline case (no tabs) along with six other cases involving two different vortex strengths at three different orientations have been computed and analyzed. The case with the highest vorticity (six vortices representing large tabs) gives the best mixing. It is shown that the influence of the vorticity acts primarily in the forward or middle portions of the duct, significantly alters the flow structure, and promotes some mixing in the lateral direction. Unmixed pockets were found at the top and bottom of the lobe, and more clever placement of tabs improved mixing in the vertical direction. The technique of replacing tabs with vortices shows promise as an efficient tool for quickly optimizing tab placement in lobed mixers.

DalBello, T.↗

Apparatus and Method for Packaging and Integrating Microphotonic Devices

An apparatus is disclosed that includes a carrier structure and an optical coupling arrangement. The carrier structure is made of a silicon material and allows for the packaging and integrating of microphotonic devices onto a single chip. The optical coupling mechanism enables laser light to be coupled into and out of a microphotonic resonant disk integrated on the carrier. The carrier provides first, second and third cavities that are dimensioned so as to accommodate the insertion and snug fitting of the microphotonic resonant disk and first and second prisms that are implemented by the optical coupling arrangement to accommodate the laser coupling.

Nguyen, Hung↗

Scoring Dawg Core Breakoff and Retention Mechanism

This novel core break-off and retention mechanism consists of a scoring dawg controlled by a set of two tubes (a drill tube and an inner tube). The drill tube and the inner tube have longitudinal concentric holes. The solution can be implemented in an eccentric tube configuration as well where the tubes have eccentric longitudinal holes. The inner tube presents at the bottom two control surfaces for controlling the orientation of the scoring dawg. The drill tube presents a sunk-in profile on the inside of the wall for housing the scoring dawg. The inner tube rotation relative to the drill tube actively controls the orientation of the scoring dawg and hence its penetration and retrieval from the core. The scoring dawg presents a shaft, two axially spaced arms, and a tooth. The two arms slide on the control surfaces of the inner tube. The tooth, when rotated, can penetrate or be extracted from the core. During drilling, the two tubes move together maintaining the scoring dawg completely outside the core. After the desired drilling depth has been reached the inner tube is rotated relative to the drill tube such that the tooth of the scoring dawg moves toward the central axis. By rotating the drill tube, the scoring dawg can score the core and so reduce its cross sectional area. The scoring dawg can also act as a stress concentrator for breaking the core in torsion or tension. After breaking the core, the scoring dawg can act as a core retention mechanism. For scoring, it requires the core to be attached to the rock. If the core is broken, the dawg can be used as a retention mechanism. The scoring dawg requires a hard-tip insert like tungsten carbide for scoring hard rocks. The relative rotation of the two tubes can be controlled manually or by an additional actuator. In the implemented design solution the bit rotation for scoring was in the same direction as the drilling. The device was tested for limestone cores and basalt cores. The torque required for breaking the 10-mm diameter limestone cores was 5 to 5.8 lb-in. (0.56 to 0.66 N-m).

Badescu, Mircea↗

Anthropomorphic teleoperation: Controlling remote manipulators with the DataGlove

A two phase effort was conducted to assess the capabilities and limitations of the DataGlove, a lightweight glove input device that can output signals in real-time based on hand shape, orientation, and movement. The first phase was a period for system integration, checkout, and familiarization in a virtual environment. The second phase was a formal experiment using the DataGlove as input device to control the protoflight manipulator arm (PFMA) - a large telerobotic arm with an 8-ft reach. The first phase was used to explore and understand how the DataGlove functions in a virtual environment, build a virtual PFMA, and consider and select a reasonable teleoperation control methodology. Twelve volunteers (six males and six females) participated in a 2 x 3 (x 2) full-factorial formal experiment using the DataGlove to control the PFMA in a simple retraction, slewing, and insertion task. Two within-subjects variables, time delay (0, 1, and 2 seconds) and PFMA wrist flexibility (rigid/flexible), were manipulated. Gender served as a blocking variable. A main effect of time delay was found for slewing and total task times. Correlations among questionnaire responses, and between questionnaire responses and session mean scores and gender were computed. The experimental data were also compared with data collected in another study that used a six degree-of-freedom handcontroller to control the PFMA in the same task. It was concluded that the DataGlove is a legitimate teleoperations input device that provides a natural, intuitive user interface. From an operational point of view, it compares favorably with other 'standard' telerobotic input devices and should be considered in future trades in teleoperation systems' designs.

Hale, J. P., II↗

Development of InSb charge-coupled infrared imaging devices: Linear imager

The following results were accomplished in the development of charge coupled infrared imaging devices: (1) a four-phase overlapping gate with 9 transfers (2-bits) and 1.0-mil gate lengths was successfully operated, (2) the measured transfer efficiency of 0.975 for this device is in excellent agreement with predictions for the reduced gate length device, (3) mask revisions of the channel stop metal on the 8582 mask have been carried out with the result being a large increase in the dc yield of the tested devices, (4) partial optical sensitivity to chopped blackbody radiation was observed for an 8582 9-bit imager, (5) analytical consideration of the modulation transfer function degradation caused by transfer inefficiency in the CCD registers was presented, and (6) for larger array lengths or for the insertion of isolated bits between sensors, improvements in InSb fabrication technology with corresponding decrease in the interface state density are required.

Phillips, J. D.↗

The DECLIC Research Facility - a Fertile Platform for NASA/CNES Scientific Collaboration

The DECLIC (Device for the Study of Critical Liquids and Crystalization) Facility was launched to the International Space Station (ISS) on Shuttle flight 17-A (August 2009) and has been in service for a little over three years. Activity from the three originally planned investigations, the HTI (High Temperature Insert) investigation, the ALI (Alice Like Insert) investigation and the DSI (Directional Solidication Insert) investigation has led to fruitful collaborations among a team of scientists, sponsored by NASA and CNES, to extend the utility of the inserts and the breadth of science beyond its initial scope. These follow-on investigations plan to use inserts that have been returned to earth for refurbishment, two of which (i.e., HTI-R and DSI-R) simply entail changing the test sample and the third (i.e., ALI-R) entails a slight hardware modication to allow for precise changes in sample volume. The first investigation, the Supercritical Water Mixture (SCWM) experiment, uses the refurbished HTI-R, which will accommodate a dilute aqueous mixture of Na2SO4 -0.5% w. This investigation will extend earlier observations of pure water at near-critical conditions. The second experiment uses a modified insert, the DSI-R, with a different concentration of succinonitrile-camphor than the original flight sample. This will allow, among other objectives, a detailed study of dendritic sidebranch formation in extended three-dimensional arrays, with the goal of elucidating whether noise amplication and/or a deterministic limit cycle is the main cause of sidebranch formation. The final experiment, the ALI-R, uses a sample cell with variable density to allow for additional observations of thermo-physical properties on SF6 at near critical conditions. The presentation will provide a discussion of the DECLIC facility's hardware, its modied inserts, and an overview of the extended science that will be achieved through these collaborative activities.

Hicks, Michael C.↗

Digital Alloy Absorber for Photodetectors

In order to increase the spectral response range and improve the mobility of the photo-generated carriers (e.g. in an nBn photodetector), a digital alloy absorber may be employed by embedding one (or fraction thereof) to several monolayers of a semiconductor material (insert layers) periodically into a different host semiconductor material of the absorber layer. The semiconductor material of the insert layer and the host semiconductor materials may have lattice constants that are substantially mismatched. For example, this may performed by periodically embedding monolayers of InSb into an InAsSb host as the absorption region to extend the cutoff wavelength of InAsSb photodetectors, such as InAsSb based nBn devices. The described technique allows for simultaneous control of alloy composition and net strain, which are both key parameters for the photodetector operation.

Hill, Cory J.↗

The Development of a PdCr Integral Weldable Strain Measurement System Based on NASA Lewis PdCr/Pt Strain Sensor for User-Friendly Elevated Temperature Strain Measurements

This report describes the development of a user friendly weldable strain gage employing the NASA Lewis PdCr/Pt wire strain sensor. The NASA sensors are pre-attached to Hastelloy X or Titanium alloy shims using name spray techniques developed under previous NASA programs. The weldable sensors are then pre-stabilized for 50 hours at 780 C in air. A weldable terminal and high temperature cable is then connected to the sensor and the assembly is pre-calibrated over the full test temperature range. Calibrated resistors are inserted into a bridge completion module at the cool end of the cable to condition the sensor in half or full bridge configuration. The sensor is attached to the structure using a common capacitive discharge spot welder. No additional high temperature stabilization or calibration is required. The resultant device is a pre-calibrated strain transducer which can be plugged into any common variety strain instrumentation.

Wnuk, S. P., Jr.↗

GSFC Cutting Edge Avionics Technologies for Spacecraft

With the launch of NASA's first fiber optic bus on SAMPEX in 1992, GSFC has ushered in an era of new technology development and insertion into flight programs. Predating such programs the Lewis and Clark missions and the New Millenium Program, GSFC has spearheaded the drive to use cutting edge technologies on spacecraft for three reasons: to enable next generation Space and Earth Science, to shorten spacecraft development schedules, and to reduce the cost of NASA missions. The technologies developed have addressed three focus areas: standard interface components, high performance processing, and high-density packaging techniques enabling lower cost systems. To realize the benefits of standard interface components GSFC has developed and utilized radiation hardened/tolerant devices such as PCI target ASICs, Parallel Fiber Optic Data Bus terminals, MIL-STD-1773 and AS1773 transceivers, and Essential Services Node. High performance processing has been the focus of the Mongoose I and Mongoose V rad-hard 32-bit processor programs as well as the SMEX-Lite Computation Hub. High-density packaging techniques have resulted in 3-D stack DRAM packages and Chip-On-Board processes. Lower cost systems have been demonstrated by judiciously using all of our technology developments to enable "plug and play" scalable architectures. The paper will present a survey of development and insertion experiences for the above technologies, as well as future plans to enable more "better, faster, cheaper" spacecraft. Details of ongoing GSFC programs such as Ultra-Low Power electronics, Rad-Hard FPGAs, PCI master ASICs, and Next Generation Mongoose processors.

Luers, Philip J.↗

A tethering system for direct measurement of cardiovascular function in the caged baboon

A device suitable for the continuous measurement of physiological activity in large, conscious monkeys has permitted the direct recording of systemic arterial blood pressure and heart rate in caged baboons. The device comprises a lightweight fiberglass backpack, retained in place on the baboon by a thoracic elastic band and shoulder straps, and a flexible stainless steel tether connecting the pack to an electrocannular slip-ring in the top center of the baboon's cage. A chronically indwelling arterial catheter inserted retrograde into the abdominal aorta via the internal iliac artery and connected to a small pressure transducer on the pack provides direct measurement of blood pressure and heart rate. Body fluids can be sampled or drugs administered via an indwelling catheter in the inferior vena cava. Electrical and fluid connections between the fiberglass pack and recording and infusion equipment located outside the cage pass through the flexible tether and remain protected from the subject. The reliability of the tethering system has been demonstrated in physiological, pharmacological, and behavioral experiments with baboons.

Byrd, L. D.↗

The Application of Ultrasonic Inspection to Crimped Electrical Connections

The development of a new ultrasonic measurement technique to quantitatively assess wire crimp terminations is discussed. The development of a prototype instrument, based on a modified, commercially available, crimp tool, is demonstrated for applying this technique when wire crimps are installed. The crimp tool has three separate crimping locations that accommodate the three different ferrule diameters. The crimp tool in this study is capable of crimping wire diameters ranging from 12 to 26 American Wire Gauge (AWG). A transducer design is presented that allows for interrogation of each of the three crimp locations on the crimp tool without reconfiguring the device. An analysis methodology, based on transmitted ultrasonic energy and timing of the first received pulse is shown to correlate to both crimp location in the tool and the AWG of the crimp/ferrule combination. The detectability of a number of the crimp failure pathologies, such as missing strands, partially inserted wires and incomplete crimp compression, is discussed. A wave propagation model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process.

Cramer, K. Elliott↗

Flexible Interior-Impression-Molding Tray

Device used inside combustion chamber of complicated shape for nondestructive evaluation of qualities of welds, including such features as offset, warping, misalignment of parts, and dropthrough. Includes flexible polypropylene tray trimmed to fit desired interior surface contour. Two neodymium boron magnets and inflatable bladder attached to tray. Tray and putty inserted in cavity to make mold of interior surface.

Anders, Jeffrey E.↗

Biomedical Wireless Ambulatory Crew Monitor

A compact, ambulatory biometric data acquisition system has been developed for space and commercial terrestrial use. BioWATCH (Bio medical Wireless and Ambulatory Telemetry for Crew Health) acquires signals from biomedical sensors using acquisition modules attached to a common data and power bus. Several slots allow the user to configure the unit by inserting sensor-specific modules. The data are then sent real-time from the unit over any commercially implemented wireless network including 802.11b/g, WCDMA, 3G. This system has a distributed computing hierarchy and has a common data controller on each sensor module. This allows for the modularity of the device along with the tailored ability to control the cards using a relatively small master processor. The distributed nature of this system affords the modularity, size, and power consumption that betters the current state of the art in medical ambulatory data acquisition. A new company was created to market this technology.

Chmiel, Alan↗

Electro-optical device for monitoring wire size

Device recognizes variations in wire size and is being used during computer memory-plane fabrication. Decrease in wire diameter, due to stretching, permits removal of wire from memory-plant mold. Monitoring provides means of detecting imperfect wire and permits fabrication of computer memory plane to be stopped prior to its insertion into mold.

Burcher, E. E.↗

New coplanar waveguide/stripline feed network for seven patch hexagonal CP subarray

A novel CPW-to-stripline post coupler is demonstrated. This device couples the output power from a coax-to-CPW inphase seven-way radial power divider to a balanced stripline line stretcher and together forms a multilayer probe-type feed network. The feed network excites a seven-patch hexagonal circularly polarized (CP) subarray. The measured return loss and insertion loss of the coupler are better than 17 dB and 0.25 dB at the design frequency of 2.875 GHz. The measured on-axis axial ratio for the left hand circular polarization (LHCP) is 1.5 dB and the 3 dB beam widths are 36 deg in the principal planes of the subarray. The gain of the subarray is 13 dB. The input return loss of the subarray is better than 10 dB.

Simons, R. N.↗

A Third Arm for the Surgeon

In laparoscopic surgery, tiny incisions are made in the patient's body and a laparoscope (an optical tube with a camera at the end) is inserted. The camera's image is projected onto two video screens, whose views guide the surgeon through the procedure. AESOP, a medical robot developed by Computer Motion, Inc. with NASA assistance, eliminates the need for a human assistant to operate the camera. The surgeon uses a foot pedal control to move the device, allowing him to use both hands during the surgery. Miscommunication is avoided; AESOP's movement is smooth and steady, and the memory vision is invaluable. Operations can be completed more quickly, and the patient spends less time under anesthesia. AESOP has been approved by the FDA.

Source record↗

Implementation of Adaptive Digital Controllers on Programmable Logic Devices

Much has been made of the capabilities of FPGA's (Field Programmable Gate Arrays) in the hardware implementation of fast digital signal processing. Such capability also makes an FPGA a suitable platform for the digital implementation of closed loop controllers. Other researchers have implemented a variety of closed-loop digital controllers on FPGA's. Some of these controllers include the widely used proportional-integral-derivative (PID) controller, state space controllers, neural network and fuzzy logic based controllers. There are myriad advantages to utilizing an FPGA for discrete-time control functions which include the capability for reconfiguration when SRAM-based FPGA's are employed, fast parallel implementation of multiple control loops and implementations that can meet space level radiation tolerance requirements in a compact form-factor. Generally, a software implementation on a DSP (Digital Signal Processor) or microcontroller is used to implement digital controllers. At Marshall Space Flight Center, the Control Electronics Group has been studying adaptive discrete-time control of motor driven actuator systems using digital signal processor (DSP) devices. While small form factor, commercial DSP devices are now available with event capture, data conversion, pulse width modulated (PWM) outputs and communication peripherals, these devices are not currently available in designs and packages which meet space level radiation requirements. In general, very few DSP devices are produced that are designed to meet any level of radiation tolerance or hardness. The goal of this effort is to create a fully digital, flight ready controller design that utilizes an FPGA for implementation of signal conditioning for control feedback signals, generation of commands to the controlled system, and hardware insertion of adaptive control algorithm approaches. An alternative is required for compact implementation of such functionality to withstand the harsh environment encountered on spacecraft. Radiation tolerant FPGA's are a feasible option for reaching this goal.