Search NASA⌕ Search

SEARCH · Search NASA

Results for “interrupt”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Performance and Health Test Procedure for Grid Energy Storage Systems: Preprint

A test procedure to evaluate the performance and health of field installations of grid-connected battery energy storage systems (BESS) is described. Performance and health metrics captured in the procedures are: Round-trip efficiency, Standby losses, Response time/accuracy, and Useable Energy/ State of Charge at different discharge/charge rates over the system's lifetime. The procedures are divided into Reference Performance Tests, which require the system to be put in a test mode and are to be conducted in intervals, and Real-time Monitoring tests, which collect data during normal operation without interruption. The procedures can be applied on a wide array of BESS with little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.can be applied on a wide array of BESS with little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.

25 ENERGY STORAGE↗

Maintenance of Maywood Laboratory Operations Support During Contractor Transition and Replacement of the Project Databases - 16329

In December 2013, Cabrera Services (Cabrera) executed transition of the FUSRAP Maywood Superfund Site remediation project operations, including an on-site accredited environmental lab, from a large business that had established technology infrastructure in place for over a decade which required updating to support the expected remediation scope and client needs. As of November 2015, Cabrera has shipped over 116,000 yd{sup 3} of contaminated soil to disposal facilities. During the transition, the USACE FUSRAP Maywood Laboratory (UFML) continued to support project operations, providing the expected timely and reliable results and maintaining their New Jersey Department of Environmental Protection certification for all parameters of concern, while having to cope with new challenges and additional tasks having the potential to disrupt the laboratory's ability to support project operations. This case study examines the challenges with maintaining a certified radiochemistry laboratory and an aggressive remediation schedule during a period of prime contractor transition which included a complete IT infrastructure overhaul, and conversion of the existing Microsoft Access laboratory database and project Electronic Data Management System (EDMS) to a customized commercial solution. Challenges: I. Procurement of a new database subcontractor and working closely with them to achieve the following: a. Migration of all environmental (including radiological, chemical, and quality control), health and safety, and spatial data as well as reports, queries, and analytical instrument software processes from a MS Access data management system to a SQL server system; and b. Verification that the functionality and data integrity of the databases remained intact. II. The onsite laboratory was changed over to a new onsite network and the following tasks were completed with little or no interruption to site operations by January 10, 2014: i. Installation of new instrument personal computers (PCs) and making them fully operational; ii. Configuration of the lab domain and server to host the LIMS (replaced all servers/domain/workstations with Windows 7 and Server 2012 machines). iii. Networking of the laboratory building into the rest of the project site via fiber optic cabling across the site. iv. Upgrade of the wide area network (WAN) data connection to high-speed Fiber Optic service; v. Upgrade of the telephones into voice over internet protocol (VOIP) phones. vi. Splitting of the database into front ends and a centralized back-end hosted on the new server to allow simultaneous access for fixes and improvements. III. Phone service interruption; phone systems were operational by January 10, 2014. Additional Tasks: I. Revision of the USACE FUSRAP Maywood Laboratory (UFML) Quality Systems Manual Rev. 1 Submitted 01/16/14; II. Writing of the Uniform Federal Policy Quality Assurance Project Plan Rev. 1 (UFP-QAPP) submitted 1/21/14. This document replaced the prior project data quality plan, the Chemical Data Quality Management Plan. III. Support of USACE communications to the New Jersey Department of Environmental Protection (NJDEP) on lab management and personnel transition to Cabrera. This work was important since it ensured a smooth transition and shows how critical project records infrastructure such as databases, can be upgraded with minimal interruption of project support. Such work may provide benefit to other similar projects, especially long term projects where database infrastructure upgrades may be beneficial in terms of improved efficiencies in data recording and transfer, and improved security in data storage. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Stability and Lattice Strain Evolution of High-Nb-Containing TiAl Alloy under Low-Cycle-Fatigue Loading

The micromechanical behavior and the effect of temperature on the micromechanical mechanism of high-Nb-containing TiAl alloy during low-cycle fatigue still remain uncertain. Herein, in situ and ex situ synchrotron-based high-energy X-ray (HEXRD) experiment results reveal that the gamma and omega(o) phases suffer compressive lattice strains but the lattice strain in the alpha(2) phase evolves from tensile to compressive during low-cycle fatigue at 900 degrees C. In addition, the three phases suffer compressive lattice strains during cooling to room temperature, which could result in larger compressive lattice strains in gamma and omega(o) phases and the change of the lattice strain state in the alpha(2) phase. The peak-broadening results show gamma recrystallization is dominant in the interrupted low-cycle-fatigue samples, whereas inhomogeneous deformation occurs in the failed low-cycle-fatigue samples. The performed synchrotron diffraction experiments offer a deeper insight into the phase transformations and micromechanism of TiAl alloy during low-cycle fatigue.

cyclic stress-strain behavior↗

Hydride-Based Solid Oxide Fuel Cell–Battery Hybrid Electrochemical System

The deployment of renewable energy technologies, such as solar photovoltaics and wind turbines, poses challenges in terms of electricity grid stability due to the intermittent nature of such energy sources, which creates a need for innovative storage solutions. We demonstrate a metal hydride-based hybrid electrochemical system that enables a solid-oxide fuel cell to operate in both fuel cell mode and battery mode, allowing for un-interrupted electricity generation. In the fuel cell mode, the device acts as a conventional fuel cell and converts the chemical energy stored in fuels into electrical energy. In the battery mode, the metal hydride near the anode releases hydrogen and quickly responds to fuel supply interruption or power demand surges. The concept demonstrated here is a promising way to provide a robust and economical solution for balancing power supply and demand for the electrical grid of the future.

25 ENERGY STORAGE↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Targeted Endovascular Temporary Vessel Occlusion with a Reverse Thermosensitive Polymer for Near-Bloodless Partial Nephrectomy: Comparison to Standard Surgical Clamping Techniques

Purpose: To determine whether reversible blood flow interruption to a randomly chosen target region of the kidney may be achieved with the injection of a reverse thermoplastic polymer through an angiographic catheter, thereby facilitating partial nephrectomy without compromising blood flow to the remaining kidney or adding risks beyond those encountered by the use of hilar clamping. Methods: Fifteen pigs underwent partial nephrectomy after blood flow interruption by vascular cross-clamping or injection of polymer (Lumagel Trade-Mark-Sign ) into a segmental artery. Five animals were euthanized after surgery (three open and two laparoscopic resection, cross-clamping n = 2), and 10 (open resection, cross-clamping n = 4) were euthanized after 6 weeks' survival. Blood specimens were obtained periodically, and angiogram and necropsy were performed at 6 weeks. Results: Selective renal ischemia was achieved in all cases. Surgical resection time averaged 9 and 24.5 min in the open and laparoscopic groups, respectively. Estimated blood loss was negligible with the exception of one case where an accessory renal artery was originally overlooked. Reversal of the polymer to a liquid state was consistent angiographically and visually in all cases. Time to complete flow return averaged 7.4 and 2 min for polymer and clamping, respectively. Angiography at 6 weeks revealed no evidence of vascular injury. Laboratory data and necropsies revealed no differences between animals undergoing vascular clamping or polymer injection. Conclusion: Lumagel was as effective as vascular clamping in producing a near bloodless operative field for partial nephrectomy while maintaining flow to the uninvolved portion of the affected kidney.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quench and Partitioning Steels

Quench and Partitioning (Q&P) steels are produced by implementing a unique thermal history designed to produce microstructures that contain martensite, and potentially ferrite, along with significant amounts of retained austenite stabilized by high carbon contents. Carbon-stabilized austenite is obtained by carbon transfer from martensite into austenite after a controlled amount of martensite is introduced by judicious selection of a so-called quench temperature at which quenching below the martensite start temperature is interrupted. Following the quench interruption, during the partitioning step, the steel is either held at the quench temperature or brought to a higher temperature and held for a specific time, to stimulate carbon transfer from martensite to austenite, to decrease the carbon supersaturation in martensite and correspondingly stabilize the austenite by carbon enrichment. A final quench to room temperature may be associated with the transformation of a certain fraction of austenite into secondary or “fresh” martensite, which is usually undesirable. A review of the Q&P process is presented, including prediction of austenite retention, alloying effects on its stabilization, a mechanical properties survey, including tensile and local formability relevant to sheet steels for automotive applications, along with perspectives on reactions competing with carbon partitioning that may operate during partitioning.

Kang, Singon↗

Depleting the carboxy-terminus of human Wnt5a attenuates collagen-induced arthritis in DBA/1 mice

Highlights: • phWnt5a-NL recombinant results in decreased severity of CII-induced arthritis. • phWnt5a-NL recombinant suppresses synovitis and osteoclastogenesis. • phWnt5a-NL recombinant induces the production of Treg cells. • phWnt5a-NL recombinant interrupts the Wnt5a-Ror2 signalling pathway. Wnt5a signalling plays pathological roles in synovial inflammation and bone destruction. In the present study, we designed four human Wnt5a-based DNA recombinants and detected their effects on immunogenicity and anti-rheumatism in a collagen-induced arthritis (CIA) model. Histomorphometry and micro-CT scanning showed that the phWnt5a-NL was superior to other recombinants because it resulted in decreased severity of arthritis, histopathological scores of synovial inflammation and bone erosion in CIA mice. In addition, ELISA and TRAP staining showed that the phWnt5a-NL-immunized CIA mice had reductions in the serum concentrations of the rheumatoid-associated cytokines IL-1β and RANKL and in osteoclastogenesis. Furthermore, flow cytometry showed that the phWnt5a-NL treatment increased the percentage of Treg cells. Finally, western blotting analysis showed that the phWnt5a-NL-immunization interrupted β-catenin and JNK expression in osteoclast precursors derived from the CIA mice. The results suggest that depleting the carboxy-terminus in hWnt5a-based DNA recombinants may be beneficial for the treatment of chronic inflammatory disorders involving bone resorption.

60 APPLIED LIFE SCIENCES↗

Intra-Arterial Infusion Chemotherapy Using Cisplatin With Radiotherapy for Stage III Squamous Cell Carcinoma of the Cervix

Purpose: To examine the effectiveness of concomitant intra-arterial infusion chemotherapy (IAIC) using cisplatin (CDDP) with radiotherapy for Stage III squamous cell carcinoma of the cervix. Materials and Methods: We analyzed 29 cases of Stage III squamous cell carcinoma of the uterine cervix treated with radiotherapy and IAIC of CDDP from 1991 to 2006. External-beam therapy was given to the whole pelvis using four opposing parallel fields with an 18-MV linear accelerator unit. A central shield was used after 30-40 Gy with external whole-pelvic irradiation, and the total dose was 50 Gy. High-dose-rate brachytherapy was given with {sup 192}Ir microSelectron. The dose at Point A was 6 Gy per fraction, 2 fractions per week, and the total number of fractions was either 3 or 4. Two or three courses of IAIC were given concomitantly with CDDP 120 mg or carboplatin 300 mg. Results: We confirmed excellent medicine distribution directly by using computed tomographic angiography. The 5-year overall survival rate for Stage III patients was 62%, the cause-specific survival rate was 70%, and the local relapse-free survival rate was 89%. Local recurrence, distant metastasis, and occurrences of both were 7%, 38%, and 3%, respectively. The incidence of severe acute hematologic adverse reactions (Grade {>=}3) was 27% for all patients; however, all recovered without interruption of radiotherapy. Severe nonhematologic effects (Grade {>=}3) were 3%, including nausea and ileus. Only 1 patient's radiotherapy was interrupted for a period of 1 week because of ileus. Severe late complication rates (Grade {>=}3) for the bladder, rectum, and intestine were 3%, 3%, and 10%, respectively. Conclusion: A combination of IAIC and systemic chemotherapy should be considered to improve the prognosis of patients with Stage III squamous cell carcinoma of the cervix.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patterns of Care in Elderly Head-and-Neck Cancer Radiation Oncology Patients: A Single-Center Cohort Study

Purpose: To compare the patterns of care for elderly head-and-neck cancer patients with those of younger patients. Methods and Materials: A retrospective review was conducted of all new mucosal head-and-neck cancer referrals to radiation oncology between July 1, 2003 and December 31, 2007 at our institution. The clinical characteristics, treatment pattern, tolerance, and outcomes were compared between the elderly (aged {>=}75 years) and younger (aged <75 years) cohorts. Results: A total of 2,312 patients, including 452 (20%) elderly and 1,860 (80%) younger patients, were studied. The elderly patients were more likely to be women (36% vs. 27%, p <.01) and to have other malignancies (23% vs. 13%, p <.01), Stage I or II disease (38% vs. 32%, p <.01), and N0 status (56% vs. 42%, p <.01). Treatment was less often curative in intent (79% vs. 93%, p <.01). For the 1,487 patients who received definitive radiotherapy (RT), no differences were found between the elderly (n = 238) and younger (n = 1,249) patients in treatment interruption, completion, or treatment-related death. Within the subset of 760 patients who received intensified treatment (concurrent chemoradiotherapy or hyperfractionated accelerated RT), no difference was seen between the elderly (n = 46) and younger (n = 714) patients in treatment interruption, completion, or treatment-related death. After a median follow-up of 2.5 years, the 2-year cause-specific survival rate after definitive RT was 72% (range, 65-78%) for the elderly vs. 86% (range, 84-88%) for the younger patients (p <.01). Conclusion: Elderly head-and-neck cancer patients exhibited different clinical characteristics and experienced different patterns of care from younger patients. Although age itself was an adverse predictor of cause-specific survival, its effect was modest. Elderly patients selected for definitive RT or intensified RT showed no evidence of impaired treatment tolerance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Painted Intensity-Modulated Radiation Therapy for Anal Cancer: A Multi-Institutional Report of Acute Toxicity and Response to Therapy

Purpose: Chemoradiation for anal cancer yields effective tumor control, but is associated with significant acute toxicity. We report our multi-institutional experience using dose-painted IMRT (DP-IMRT). Patients and Methods: Between August 2005 and May 2009, 43 patients were treated with DP-IMRT and concurrent chemotherapy for biopsy-proven, squamous cell carcinoma of the anal canal at two academic medical centers. DP-IMRT was prescribed as follows: T2N0: 42 Gy, 1.5 Gy/fraction (fx) to elective nodal planning target volume (PTV) and 50.4 Gy, 1.8 Gy/fx to anal tumor PTV; T3-4N0-3: 45 Gy, 1.5 Gy/fx to elective nodal PTV, and 54 Gy, 1.8 Gy/fx to the anal tumor and metastatic nodal PTV >3 cm with 50.4 Gy, 1.68 Gy/fx to nodal PTVs {<=}3 cm in size. Acute and late toxicity was reported by the treating physician. Actuarial analysis was performed using the Kaplan-Meier method. Results: Median age was 58 years; 67% female; 16% Stage I, 37% II; 42% III; 5% IV. Fourteen patients were immunocompromised: 21% HIV-positive and 12% on chronic immunosuppression. Median follow-up was 24 months (range, 0.6-43.5 months). Sixty percent completed chemoradiation without treatment interruption; median duration of treatment interruption was 2 days (range, 2-24 days). Acute Grade 3+ toxicity included: hematologic 51%, dermatologic 10%, gastrointestinal 7%, and genitourinary 7%. Two-year local control, overall survival, colostomy-free survival, and metastasis-free survival were 95%, 94%, 90%, and 92%, respectively. Conclusions: Dose-painted IMRT appears effective and well-tolerated as part of a chemoradiation therapy regimen for the treatment of anal canal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Continuous 7-Days-A-Week External Beam Irradiation in Locally Advanced Cervical Cancer: Final Results of the Phase I/II Study

Purpose: To evaluate the feasibility and efficacy of definitive continuous 7-days-a-week pelvic irradiation without breaks between external beam radiotherapy and brachytherapy in locally advanced cervical cancer. Methods and Materials: Between November 1998 and December 1999, 30 patients with International Federation of Obstetrics and Gynecology Stage IIB or IIIB cervical cancer were included in a prospective Phase I/II study of continuous 7-days-a-week pelvic irradiation, to the total Manchester point B dose of 40.0-57.6 Gy. The first 13 patients (Group A) were given a daily tumor dose of 1.6 Gy, and the remaining 17 patients (Group B) were given 1.8 Gy. One or two immediate brachytherapy applications (point A dose 10-20 Gy, each) were performed in 28 cases. Results: Two patients did not complete the irradiation because of apparent early progression of disease during the irradiation. Eleven of the 28 evaluable patients (39%; 45% and 35% in Groups A and B, respectively) completed their treatment within the prescribed overall treatment time. Acute toxicity (including severe European Organisation for Research and Treatment of Cancer/Radiation Therapy Oncology Group Grade 3 and 4 effects in 40%) was experienced by 83% of patients and resulted in unplanned treatment interruptions in 40% of all patients (31% and 47% of patients in Groups A and B, respectively). Severe intestinal side effects occurred in 31% and 41% of Patients in Groups A and B, respectively (p = 0.71). The 5-year overall survival probability was 33%. Cancer recurrence occurred in 63% of patients: 20% inside and 57% outside the pelvis. Cumulative incidence of late severe bowel and urinary bladder toxicity at 24 months was 15%. Conclusion: Continuous irradiation in locally advanced cervical cancer is associated with a high incidence of severe acute toxicity, resulting in unplanned treatment interruptions. Late severe effects and survival after continuous radiotherapy do not substantially differ from those obtained with conventionally fractionated radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Induction Gemcitabine and Stereotactic Body Radiotherapy for Locally Advanced Nonmetastatic Pancreas Cancer

Purpose: Stereotactic body radiotherapy (SBRT) has been used successfully to treat patients with locally advanced pancreas cancer. However, many patients develop metastatic disease soon after diagnosis and may receive little benefit from such therapy. We therefore retrospectively analyzed a planned strategy of initial chemotherapy with restaging and then treatment for those patients with no evidence of metastatic progression with SBRT. Methods and Materials: Forty-seven patients received gemcitabine (1,000 mg/m{sup 2} per week for 3 weeks then 1 week off) until tolerance, at least six cycles, or progression. Patients without metastases after two cycles were treated with SBRT (tolerance-based dose of 24-36 Gy in 3 fractions) between the third and fourth cycles without interrupting the chemotherapy cycles. Results: Eight of the 47 patients (17%) were found to have metastatic disease after two cycles of gemcitabine; the remaining 39 patients received SBRT. The median follow-up for survivors was 21 months (range, 6-36 months). The median overall survival for all patients who received SBRT was 20 months, and the median progression-free survival was 15 months. The local control rate was 85% (33 of 39 patients); and 54% of patients (21 of 39) developed metastases. Late Grade III toxicities such as GI bleeding and obstruction were observed in 9% (3/39) of patients. Conclusion: For patients with locally advanced pancreas cancer, this strategy uses local therapy for those who are most likely to benefit from it and spares those patients with early metastatic progression from treatment. SBRT delivers such local therapy safely with minimal interruption to systemic chemotherapy, thereby potentially improving the outcome in these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlation between grain boundary misorientation and M{sub 23}C{sub 6} precipitation behaviors in a wrought Ni-based superalloy

The correlation between the grain boundary misorientation and the precipitation behaviors of intergranular M{sub 23}C{sub 6} carbides in a wrought Ni–Cr–W superalloy was investigated by using the electron backscattered diffraction (EBSD) technique. It was observed that the grain boundaries with a misorientation angle less than 20°, as well as all coincidence site lattice (CSL) boundaries, are immune to precipitation of the M{sub 23}C{sub 6} carbides; in contrast, the random high-angle grain boundaries with a misorientation angle of 20°–40° provide preferential precipitation sites of the M{sub 23}C{sub 6} carbides at the random high-angle grain boundaries with a higher misorientation angle of 55°–60°/[2 2 3] turn to retard precipitation of M{sub 23}C{sub 6} carbides owing to their nature like the Σ3 grain boundaries and retard the precipitation of M{sub 23}C{sub 6} carbides. The low-angle and certain random grain boundary segments induced by twins were found to interrupt the precipitation of the M{sub 23}C{sub 6} carbides along the high-angle grain boundaries. - Highlights: ► The low angle grain boundaries and CSL boundaries are immune to precipitation. ► M23C6 precipitate preferentially at random grain boundaries within 20°–40°. ► Some certain random grain boundary segments interrupt M23C6 precipitation.

36 MATERIALS SCIENCE↗

Low-cost, constrained-motion dynamometer for milling force measurement

This paper describes the design and testing of a low-cost dynamometer for milling force measurement. The monolithic design is based on constrained-motion/flexure-based kinematics, where force is inferred from displacement measured using a low-cost optical interrupter (i.e., a knife edge that partially interrupts the beam in an emitter-detector pair). The time-dependent displacement of the dynamometer’s moving platform caused by the milling force is converted to the frequency domain, multiplied by the inverse of the single degree of freedom frequency response, and converted back to the time domain to obtain the time dependent cutting force. Lastly, comparisons with commercially available, piezoelectric-based force measurement are provided.

47 OTHER INSTRUMENTATION↗

Use of non-contact voltmeter to quantify potential induced degradation in CdTe modules

Potential induced degradation (PID) is a significant reliability issue for photovoltaic modules in the field. Conventionally, to detect the PID-affected modules, all the modules in a string are individually disconnected and measured using I-V (current–voltage) tracers. It is extremely time-consuming, expensive and unsafe (if the module connectors are field aged) approach. In our approach, we aim detecting the PID-affected modules quickly, inexpensively and safely without disconnecting individual modules in the string. In this study, contactless electrostatic voltmeter’s (ESV) strength was explored to detect the PID-affected cadmium telluride (CdTe) modules in a string. These contactless measurements on high-voltage PV strings could make this technique unique and preferable to detect PID-affected modules in a string compared to the I-V curve method. In this work, a CdTe module was stressed for PID using the Aluminum (Al) foil method in a walk-in environmental chamber, which resulted in a reduction of module's peak current (I max ), peak voltage (Vmax), and fill factor (FF), and hence power (Pmax). Outdoor light I-V, EL, and ESV measurements were performed pre- and post-PID to determine the effectiveness of the non-contact ESV technique. Further, the ESV technique successfully detected the change in V max , and hence Pmax, compared to the pre-and post-PID conditions. A difference of less than 2% was observed in the results of the non-contact and non-interruptive method compared to the conventionally used interruptive voltmeter or I-V tracer method. This technique and the test results demonstrate a significant promise to identify poor-performing modules in PV string without disconnection of individual modules in the string.

14 SOLAR ENERGY↗

Heliostat optical error inspection with polarimetric imaging drone

On a Concentrated Solar Power (CSP) field, optical errors have significant impacts on the collection efficiency of heliostats. Fast, cost-effective, labor-efficient, and non-intrusive autonomous field inspection remains a challenge. Approaches using imaging drone, i.e., Unmanned Aerial Vehicle (UAV) system integrated with high resolution visible imaging sensors, have been developed to address these challenges; however, these approaches are often limited by insufficient imaging contrast. Here, in this study, we report a polarimetry-based method with a polarization imaging system integrated on UAV to enhance imaging contrast for in-situ detection of heliostat mirrors without interrupting field operation. We developed an optical model for skylight polarization pattern to simulate the polarization images of heliostat mirrors and obtained optimized waypoints for polarimetric imaging drone flight path to capture images with enhanced contrast. The polarimetric imaging-based method improved the success rate of edge detections in scenarios which were challenging for mirror edge detection with conventional imaging sensors. We have performed field tests to achieve significantly enhanced heliostat edge detection success rate and investigate the feasibility of integrating polarimetric imaging method with existing imaging-based heliostat inspection methods, i.e., Polarimetric Imaging Heliostat Inspection Method (PIHIM). Our preliminary field test results suggest that the PIHIM hold the promise to enable sufficient imaging contrast for real-time autonomous imaging and detection of heliostat field, thus suitable for non-interruptive fast CSP field inspection during its operation.

CSP Field↗